• Title/Summary/Keyword: Heat Transfer Limitation

Search Result 54, Processing Time 0.028 seconds

Theoretical Analysis of Factors Affecting to Heat Transfer Limitation in Screen Mesh Wick Heat Pipe (스크린 메쉬윅 히트파이프의 열전달한계에 영향을 미치는 인자의 이론적 해석)

  • 이기우;노승용;박기호
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.11
    • /
    • pp.880-889
    • /
    • 2002
  • The purpose of the present study is to examine the factors affecting the heat transfer limitations of screen mesh heat pipe for electronic cooling by theoretical analysis. Diameter of pipe was 6 mm, and mesh numbers are 50, 100, 150, 200 and 250 and water was selected as a working fluid. According to the change of mesh number, wick layer, inclination and saturation temperature, capillary pressure, pumping pressure, liquid friction coefficient in wick, vapor friction coefficient, capillary limitation, entrainment limitation, sonic limitation and boiling limitation we analyzed by theoretical design method of a heat pipe. As some results, the capillary limitation in small diameter of heat pipe is largely affected by mesh number and wick layer.

A Study on the Operational Characteristics of a U-shape Heat Pipe (U형 히트파이프의 작동 특성에 관한 연구)

  • Gang, Hwan-Guk;Kim, Cheol-Ju;Lee, Yong-Su
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.12
    • /
    • pp.1711-1720
    • /
    • 2001
  • In this study, the heat transfer characteristics of a U-shape heat pipes were investigated. Heat is supplied to the U heat pipe through its middle zone(evaporator), and is released to the environment through its both arms(condensers). Both heat transfer coefficients and heat transport limitations were measured and compared with correlations previously developed for straight type heat pipes. Special concerns were focused to the cases, when each of condensers were submitted to a different cooling conditions, relatively. As a result. the heat transfer limitation of a U-shape heat pipe was found out to be 10∼15% less than the value for a straight heat pipe with an equivalent size.

An Analytic Study on Flooding Heat Transport Limitation for a PFC Two-phase Closed Thermosyphon (PFC 열사이폰의 플러딩 한계에 대한 해석적 연구)

  • Lee, Jin-Sung;Kim, Chul-Ju
    • Proceedings of the KSME Conference
    • /
    • 2000.11b
    • /
    • pp.285-290
    • /
    • 2000
  • The present study was conducted to determine flooding heat transfer limitation of a two-phase closed thermosyphon using PFC as working fluid. The variables such as pipe inner diameter, working fluid property, operating temperature were examined by way of analytic method. Comparison of experimental data on flooding heat transfer limitation shows a fairly good agreement with the analytic results. An expression fur flooding maximum heat transfer rate was formulated as a function of Bond number and saturation pressure and written as follows ; $Q_{max} =0.989{\cdot}P_s^{0.286}{\cdot}Bo^{1.74}$.

  • PDF

Fundamental study on performance characteristics of a micro heat pipe with triangular cross section (삼각단면 극소히트파이프의 작동특성에 관한 기초 연구)

  • 문석환;김종오;김철주
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.2
    • /
    • pp.176-184
    • /
    • 1999
  • Numerical and experimental studies were performed to examine the characteristics of heat and mass transfer processes for a Micro Heat Pipe(MHP) with a triangular cross-section. Solutions on mass flow rate, pressure variation, and radius of meniscus were obtained using the mathematical model developed by Faghri and Khrustalev. To obtain an increase in capillary limitation, a triangular tube with curved walls was designed and fabricated. The measurement by microscope showed that the radius at corners of the tube was ranging between 0.03-0.05mm. Performance test for MHPs using the triangular tube with curved walls proved a substantial increasement in heat transport limitation, with 4.5W and 2.0W in case of using water and ethanol as a working fluid, respectively. In the previous study by Faghri a limitation of 0.5W was reported for a water MHP with a regular triangular tube.

  • PDF

The Effect of the Fill Charge Ratio on the Heat Transfer Characteristics of a Two-Phase Closed Thermosyphon (충전율의 변화가 밀폐형 2-상 열사이폰의 열전달 특성에 미치는 영향에 관한 연구)

  • Park, Yong-Joo;Hong, Sung-Eun;Kim, Chul-Ju
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.12
    • /
    • pp.1646-1654
    • /
    • 2002
  • A two-phase closed thermosyphon was one of the most effective devices in the removing heat because of its simple structure, thermal diode characteristics, wide operating temperature range and so on. In this study, a two-phase closed thermosyphon(working fluid PFC(C6F14), container copper(inner grooved surface)) was fabricated with a reservoir which can change the fill charge ratio. The experiments were performed in the range of 50~600W heat flow rate and 10~70% fill charge ratio. The results were compared with some correlations that were presented by Rohsenow and Immura et al. in the evaporator, by Nusselt, Gross and Uehara et al. in the condenser and by Cohen and Bayley, Wallis, Kutateladze and Faghri et al. in heat transfer limitation etc.. The heat transfer coefficient at the evaporator increased with the input power. However the effect of the fill charge ratio was nearly negligible. At the condenser, it showed an opposite trend to the evaporator and with increase of the fill charge ratio, showed some enhancement of heat transfer. The heat transport limitation was occurred by the dry-out limitation for small fill charge ratio(10%) and presented about 100W. For the case of large fill charge ratio(Ψ$\geq$40%), it was occurred by the flooding limitation at about 500W.

A study on heat transport limitation for a perfluorocarbon heat pipe (PFC 히트파이프의 열전달 한계에 관한 연구)

  • 강환국;김재진;김철주
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.3
    • /
    • pp.313-320
    • /
    • 1999
  • A PFC(Perfluorocarbon) heat pipe has been used recently for cooling of GTO(gate turn off) thyristors or diodes in electric commuter trains. The present study was conducted to determine heat transport limitation of a PFC heat pipe which is one of the important parameters in heat pipes design. The variables such as tube diameter, fill charge ratio, internal surface structure and operating temperature were examined by way of experiment. Experimental data showed that the heat transport limitation of PFC heat pipe was considerably low and mostly dependent on tube diameter, with the value of 440~500W for d$o$/=22.23mm and 150~200W for d$o$=15.88mm. The other parameters had negligible effects, except for the case of small charge ratio less than 30%. Some correlations proposed by previous studies were in agreement with data from this study within 10~30%.

  • PDF

A Study on the Capillary Limitation in Copper-Water Heat Pipes with Screen Wicks (스크린 윅을 삽입한 동-물 히트파이프에서 모세관 한계에 관한 연구)

  • 박기호;이기우;노승용;이석호;유성연
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.12
    • /
    • pp.1023-1030
    • /
    • 2002
  • This paper is to research the heat transfer characteristic performance of the copper-water heat pipe with the screen wicks. Recently, the semiconductor capacity of an electronic unit has been larger, on the contrary, its size has been much smaller. As a result, a high-performance cooling system is needed. Experimental variables are inclination angles, temperatures of cooling water and the mesh number of screen wicks. The distilled water was used for the working fluid. At the inclination angle $6^{\circ}$ in top heat mode, the two layers of the 100-mesh screen wick showed the best heat transfer performance. The thermal resistance of the two layers with the 100-mesh screen was 0.7~$0.8^{\circ}C$/W.

A Study on Application of a Heat Pipe to an Evacuated Glass Tube Solar Collector (진공 유리관 태양열 집열기에 열파이프의 적용을 위한 기초 연구)

  • Kim, Chul-Joo
    • Solar Energy
    • /
    • v.12 no.2
    • /
    • pp.9-17
    • /
    • 1992
  • This is an experimental work concerning about an application of a heat pipe to an evacuated-glass-tube solar collector system. A methanol heat pipe with length of 0.7 m and diameter of 8 mm was manufactured and tested to compare its performance with that of freon thermosyphon which was originally used in a solar collector system fabricated at Thermomax Co.. Then this methanol heat pipe was utilized to be one component, i.e. heat transfer element, of the present experimental model of a solar collector. This model was performed the operation test as its absorber plate was irradiated by infrared lamps. The following results were obtained. (1) The methanol heat pipe was showed a stable operation when the variation of axial heat transport was $0{\sim}40$ watts and that of inclination angle was $30{\sim}90^{\circ}$. (2) The heat transport capability of the heat pipe was proved to be higher than that of the thermosyphon, because the heat transport limitation of the latter was occured at about 30 watt. (3) The heat pipe in a solar collector was also showed good performance as it transmitted absorbed energy.

  • PDF

Study on the Capillary Limitation in Copper-Water Heat Pipes with Screen Wicks

  • Park, Ki-Ho;Lee, Ki-Woo;Noh, Seung-Yong;Rhi, Seok-Ho;Yoo, Seong-Yeon
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.12 no.1
    • /
    • pp.21-29
    • /
    • 2004
  • This paper is to study the heat transfer performance of the copper-water heat pipe with screen wicks. Recently, the semiconductor capacity of an electronic unit becomes larger, but its size becomes much smaller. As a result, a high- performance cooling system is needed. Experimental variables are inclination angles, temperatures of cooling waters and the mesh number of screen wicks. The distilled water was used as a working fluid. Based on the experimental results, when the copper-water heat pipe of 6mm diameter is used at the top heat mode, the heat transfer performance of 100 mesh 2 layers heat pipe is better than that of 150 and 200 mesh. The thermal resistance of the two layers with the 100-mesh screen was 0.7-$0.8^{\circ}C$/W.

Numerical Study on the Performance and the Heat Flux of a Coaxial Cylindrical Steam Reformer for Hydrogen Production (수소 생산을 위한 동축원통형 수증기 개질기의 성능 및 열유속에 대한 수치해석 연구)

  • Park, Joon-Guen;Lee, Shin-Ku;Bae, Joong-Myeon;Kim, Myoung-Jun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.33 no.9
    • /
    • pp.709-717
    • /
    • 2009
  • Heat transfer rate is a very important factor for the performance of a steam reformer because a steam reforming reaction is an endothermic reaction. Coaxial cylindrical reactor is the reactor design which can improve the heat transfer rate. Temperature, fuel conversion and heat flux in the coaxial cylindrical steam reformer are studied in this paper using numerical method under various operating conditions. Langmuir-Hinshelwood model and pseudo-homogeneous model are incorporated for the catalytic surface reaction. Dominant chemical reactions are assumed as a Steam Reforming (SR) reaction, a Water-Gas Shift (WGS) reaction, and a Direct Steam Reforming (DSR) reaction. Although coaxial cylindrical steam reformer uses 33% less amount of catalyst than cylindrical steam reformer, its fuel conversion is increased 10 % more and its temperature is also high as about 30 degree. There is no heat transfer limitation near the inlet area at coaxial-type reactor. However, pressure drop of the coaxial cylindrical reactor is 10 times higher than that of cylindrical reactor. Operating parameters of coaxial cylindrical steam reformer are the wall temperature, the inlet temperature, and the Gas Hourly Space Velocity (GHSV). When the wall temperature is high, the temperature and the fuel conversion are increased due to the high heat transfer rate. The fuel conversion rate is increased with the high inlet temperature. However, temperature drop clearly occurs near the inlet area since an endothermic reaction is active due to the high inlet temperature. When GHSV is increased, the fuel conversion is decreased because of the heat transfer limitation and short residence time.