• Title/Summary/Keyword: Heat Transfer Coefficients

Search Result 827, Processing Time 0.027 seconds

Estimation of Heat Insulation and Light Transmission Performance According to Covering Methods of Plastic Greenhouses (플라스틱온실의 피복방식에 따른 보온 및 광투과 성능 평가)

  • Lee, Hyun-Woo;Kim, Young-Shik;Sim, Sang-Youn;Lee, Jong-Won;Diop, Souleymane
    • Journal of Bio-Environment Control
    • /
    • v.22 no.3
    • /
    • pp.270-278
    • /
    • 2013
  • The objective of the present study is to provide data needed to decide covering method to be able to increase the thermal insulation and light transmittance efficiency of commercial greenhouse. The thermal insulation effect, PPF transmittance and quantity of condensation water were estimated in experimental tomato greenhouses covered with three types of coverings of single layer, air inflated and conventional double layers covering. The overall heat flow of air inflated double layers greenhouse was similar to that of conventional double layers greenhouse, but the temperature between covering material and thermal screen in air inflated double layers greenhouse was lower than that in conventional double layers greenhouse at the same outside temperature condition due to air leakage through the gap of roof vent. The overall heat transfer coefficients acquired by experiment that was performed in single layer and conventional double layers greenhouses were close to those obtained from model experiment. Even though the PPF transmittance of air inflated double layers greenhouse was lower than that of single layer greenhouse, which was greater than that of conventional double layers greenhouse. The quantity of condensation water on covering surface of single layer greenhouse was greater than that of air inflated double layers greenhouse due to lower covering surface temperature.

Temperature Distribution and It's Contribution to Self-equilibrium Thermal Stress in Bridge (교량 단면 내 온도분포에 따른 자체평형 열응력 해석)

  • Kwak, Hyo-Gyoung;Kwon, Se-Hyung;Ha, Sang-Hee
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.24 no.5
    • /
    • pp.531-542
    • /
    • 2011
  • The time-dependent temperature distribution across the section in bridges is determined on the basis of the three-dimensional finite element analyses and numerical time integration in this study. The material properties which change with time and thermal stress of concrete are taken into account to effectively trace the early-age structural responses. Since the temperature distribution is nonlinear and depends upon many material constants such as the thermal conductivity, specific heat, hydration heat of concrete, heat transfer coefficients and solar radiation, three representative influencing factors of the construction season, wind velocity and bridge pavement are considered at the parametric studies. The validity of the introduced numerical model is established by comparing the analytical predictions with results from previous analytical studies. On the basis of parametric studies for four different bridge sections, it is found that the creep deformation in concrete bridges must be considered to reach more reasonable design results and the temperature distribution proposed in the Korean bridge design specification need to be improved.

Effect of Laser Processing Patterns on the Bonding Interface Quality during Laser Sintering of Magnesium Alloys with Zirconia (마그네슘 합금 표면의 지르코니아 분말 레이저 소결과정에서 조사 패턴이 접합 계면 품질에 미치는 영향)

  • Yoon, Sangwoo;Kim, Joohan
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.20 no.2
    • /
    • pp.51-57
    • /
    • 2021
  • The quality of the ceramic sintered coating on a metal surface through laser surface treatment is affected by the laser irradiation pattern. Depending on the laser irradiation pattern, the amount of residual stress and heat applied or accumulated on the surface increases or decreases, affecting the thickness attained in the ceramic sintering area. When the heat energy accumulated in the sintering area is high, the ceramic and the metal alloy melt and sufficiently mix to form a homogeneous and thick bonding interface. In this study, the thermal energy accumulation in the region sintered with zirconia was controlled using four types of laser processing patterns. The thickness of the diffusion region is analyzed by laser-induced breakdown spectroscopy of Mg-ZrO2 generated by laser sintering zirconia powder on the magnesium alloy surface. On the basis of the analysis of the Mg and Zr present in the sintered region through LIBS, the effect of the irradiation pattern on the sintering quality is confirmed by comparing and analyzing the heat and mass transfer tendency of the diffusion layer and the degree of diffusion according to the irradiation pattern. The derived diffusion coefficients differed by up to 9.8 times for each laser scanning pattern.

Analysis on the Ventilation Performance of Single-span Tomato Greenhouse with Roof Windows (천창을 설치한 토마토 재배 단동 온실의 환기성능 분석)

  • Nam, Sang-Woon;Kim, Young-Shik;Both, Arend-Jan
    • Journal of Bio-Environment Control
    • /
    • v.20 no.2
    • /
    • pp.78-82
    • /
    • 2011
  • Ventilation rates, inside and outside weather data were measured in a arch-shape single-span plastic greenhouse growing tomatoes. On the roof of the experimental greenhouse, round windows which have a diameter of 0.6 m were installed at intervals of 8m. It showed that the number of air changes in this greenhouse were average 0.17 volumes per minute and in the range of 0.02 to 0.32 volumes per minute. These air changes are insufficient to meet the recommended ventilation rate for commercial greenhouses, and it is estimated that interval of 6 m is appropriate for spring or fall season. For summer season, it is necessary to narrow the space or to enlarge the open area of roof windows. Using the heat balance model, the evapotranspiration coefficients of greenhouse tomatoes were estimated from experimental ventilation data, overall heat transfer and solar radiation. It showed that the evapotranspiration coefficients were average 0.62 and in the 0.39 to 0.85 range. We suggest applying 0.6 as the evapotranspiration coefficient in design of ventilation for the single-span tomato greenhouses.

Effects of the Concentration and the Temperature on the Thermophysical Properties of Purely-Viscous Non-Newtonian Fluid (순수점성 비뉴톤유체의 물성치들에 대한 농도 및 온도의 영향)

  • 조금남
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.3
    • /
    • pp.670-680
    • /
    • 1994
  • The thermophysical properties of Non-Newtonian fluid as the function of the temperature and the concentration are needed in many rheological heat transfer and fluid mechanics problems. The present work investigated the effects of the concentration and the temperature on the thermophysical properties of purely-viscous Non-Newtonian fluids such as the isobaric thermal expansion coefficient, density, zero-shear-rate viscosity, and zero-shear-rate dynamic viscosity within the experimental temperature range from $25^{\circ}C$ to $55^{\circ}C$. The densities of the test fluids were determined as the function of the temperature by utilizing a reference density and the least square equation for the measured isobaric thermal expansion coefficient. As the concentration of purely-viscous Non-Newtonian fluid was increased up to 10,000 wppm, the densities were proportionally increased up to 0.4%. The zero-shear-rate viscosities of test fluids were measured before and after the measurements of the first thermal expansion coefficients and the densities of Non-Newtonian fluid. Even though they were changed up to approximately 22% due to thermal aging and cycling, they had no effects on the thermal expansion coefficients and the densities of Non-Newtonian fluid. The zero-shear-rate dynamic viscosities for purely-viscous Non-Newtonian fluids were compared with the values for distilled water. They showed the similar trend with the zero-shear-rate viscosities due to small differences in the densities for both distilled water and purely-viscous Non-Newtonian fluid.

Calculation of the Absorption Coefficient and Weighting Factor Expressing the Total Emissivity of Flame (화염의 총괄폭사 계수를 나타내는 급수계수 및 가중치의 계산)

  • 하만영;허병기
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.10 no.1
    • /
    • pp.121-130
    • /
    • 1986
  • Using the sbsorption coefficients and the weighting factors of the gray gas, the total emissivities of C $O_{2}$- $H_{2}$O and C $O_{2}$- $H_{2}$O- transient species-soot gas mixtures can be expressed by the following equation, [a numerical formula] Where, $a_{i}$ and $K_{i}$ represent the weighting factor and the absorption coeffient of i-gray gas respectively; L is the pathlength of the gas. This equation is widely used for the analyses of the radiation heat transfer in the combustors of internal combustion engines and in the furnace of external combustion engines. In this work, a simple calculation model of the weighting factor and the absorption coeffient of the above equation was developed. The weighting factors and the absorption coefficients of combustion products were calculated by applying the model to various kinds of fossil fuels such as coal and heavy oil. Then, the computed total emissivities for each fuel and pathlength were compared with measured and calculated values which have been already published in the literatures. The followings were the results obtained through the comparisons between the calculated emissivites and the published values; the developed model for the calculations of the weighting factor and the absorption coefficient of C $O_{2}$- $H_{2}$O and C $O_{2}$- $H_{2}$O- transient species-soot gas mixtures could be applied over the wide ranges of the temperature and the pathlength; the errors between the total emissivities calculted and the values published were maximum 10%, and average 1%, respectively.

The Drying Characteristics of Apples at Various Drying Conditions (사과의 건조조건(乾燥條件)에 따른 건조특성(乾燥特性))

  • Jung, Shin-Kyo;Choi, Yong-Hee;Shon, Tae-Hwa;Choi, Jong-Uck
    • Korean Journal of Food Science and Technology
    • /
    • v.18 no.1
    • /
    • pp.61-65
    • /
    • 1986
  • This study was performed to examine the drying characteristics of apples at various drying conditions. Air velocity has no effect on the drying rate except the constant rate period. In this experiment the diffusion coefficients of moisture in the apple tissue were in the range of $1.1470-2.2148{\times}10cm^2/sec$. As a result of balance of heat and mass transfer during the falling rate period. an empirical equation based on Fick's law was obtained as follows; $log{\Delta}t\;=\;log\;t_o\;-\;D{\frac{{\pi}^2{\theta}}{4d.}}$ This equation can be used to calculate the temperature of apples during the falling rate period, provided the diffusion coefficients of apple are known. The experimental values of the internal moisture distribution during apple dehydration were nearly in accord with the theoretical values.

  • PDF

Tropical Night (Nocturnal Thermal High) in the Mountainous Coastal City

  • Choi, Hyo
    • Journal of Environmental Science International
    • /
    • v.13 no.11
    • /
    • pp.965-985
    • /
    • 2004
  • The investigation of driving mechanism for the formation of tropical night in the coastal region, defined as persistent high air temperature over than 25$^{\circ}C$ at night was carried out from August 14 through 15, 1995. Convective boundary layer (CBL) of a 1 km depth with big turbulent vertical diffusion coefficients is developed over the ground surface of the inland basin in the west of the mountain and near the top of the mountain, while a depth of thermal internal boundary layer (TIBL) like CBL shrunken by relatively cool sea breeze starting at 100 km off the eastern sea is less than 150 m from the coast along the eastern slope of the mountain. The TIBL extends up to the height of 1500 m parallel to upslope wind combined with valley wind and easterly sea breeze from the sea. As sensible heat flux convergences between the surface and lower atmosphere both at the top of mountain and the inland coast are much greater than on the coastal sea, sensible heat flux should be accumulated inside both the TIBL and the CBL near the mountain top and then, accumulated sensible heat flux under the influence of sea breeze circulation combined with easterly sea breeze from sea to inland and uplifted valley wind from inland to the mountain top returning down toward the eastern coastal sea surface should be transported into the coast, resulting in high air temperatures near the coastal inland. Under nighttime cooling of ground surface after sunset, mountain wind causes the daytime existed westerly wind to be an intensified westerly downslope wind and land breeze further induces it to be strong offshore wind. No sensible heat flux divergence or very small flux divergence occurs in the coast, but the flux divergences are much greater on the top of the mountain and along its eastern slope than on the coastal inland and sea surfaces. Thus, less cooling down of the coastal surface than the mountain surface and sensible heat transfer from warm pool over the coast into the coastal surface produce nocturnal high air temperature on the coastal inland surfaces, which is not much changed from daytime ones, resulting in the persistence of tropical night (nocturnal thermal high) until the early in the morning.

Measurement and Comparison of Overall Heat Transfer Coefficients for Greenhouse Covering Materials with Thermal Screens (온실용 피복재 및 보온재의 관류열전달계수 측정 및 비교)

  • Diop, Souleymane;Lee, Jong Won;Lee, Hyun Woo
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.56 no.4
    • /
    • pp.41-51
    • /
    • 2014
  • 천공복사를 구현할 수 있는 관류열전달계수 측정용 실내실험장치를 제작하고 국내에서 사용되고 있는 온실 피복재 및 보온재의 관류열전달계수를 측정하여 실외실험에서 측정된 결과와 비교하여 타당성을 평가하였다. 외부피복은 0.1 mm 두께의 폴리에틸렌 필름을 사용하여 일중 및 이중피복으로 처리하였다. 이중외부피복조건의 경우 4가지 종류의 보온재를 처리하여 총 6가지 피복처리에 대하여 실험을 실시하였다. 모든 피복처리조건에 대하여 야간복사 유무에 따른 관류열전달계수 측정실험이 수행되었다. 천공복사의 유무에 따라 온실피복재의 관류열전달계수의 변화 경향이 크게 차이가 있었기 때문에 실내실험을 통해 관류열전달계수를 측정하기 위해서는 반드시 실제의 천공복사를 구현할 수 있는 실험장치가 필요할 것으로 판단된다. 실내 실험결과와 실외 실험결과가 비교적 잘 일치하였으며 실내실험장치를 이용하여 관류열전달계수를 측정하는 것이 타당성이 있음을 확인할 수 있었다. 천공복사 유무에 따른 관류열전달계수의 차이는 핫박스 내외부의 온도차이가 증가함에 따라 감소하는 것으로 나타났다.

A Numerical Study on the Impinging Jet Flow Characteristics in the Presence of Applied Magnetic Fields (자기장이 인가된 충돌제트의 유동 특성에 관한 수치적 연구)

  • Lee Hyun Goo;Yoon Hyun Sik;Hong Seung Do;Ha Man Yeong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.5 s.236
    • /
    • pp.537-544
    • /
    • 2005
  • The present study numerically investigates two-dimensional fluid flow in the confined jet flow in the presence of applied magnetic field. Numerical simulations to calculate the fluid flow and heat transfer in the confined jet are performed for different Reynolds numbers in the absence and presence of magnetic fields in the range of $0{\le}N{\le}0.05$, where N is the Stuart number (interaction parameter) which is the ratio of electromagnetic force to inertia force. The present study reports the detailed information of flow in the channel at different Stuart numbers. As the intensity of applied magnetic fields increases, the vortex shedding formed in the channel becomes weaker and the oscillating amplitude of impinging jet decreases. The flow fields become the steady state if the Stuart number is greater than a critical value. Thus the pressure coefficients at the stagnation point also vary as a function of Stuart number.