• 제목/요약/키워드: Heat Regenerator

검색결과 79건 처리시간 0.025초

슬래브축열 공조시스템의 축열성능에 관한 실험적 연구 (An Experimental Study on Thermal Storage Performance of an Air Conditioning System with Slab Thermal Storage)

  • 정재훈;신영기
    • 설비공학논문집
    • /
    • 제17권5호
    • /
    • pp.427-435
    • /
    • 2005
  • This paper investigates the thermal storage performance of the office building which has adopted an air conditioning system with its slab structure as a regenerator. Four cases of the thermal storage performance experiment were conducted. Room air temperatures, floor slab temperatures, temperatures around the air conditioning unit were logged and analyzed. The load handling capacity of the air conditioning unit and the amount of heat stored in the slab were decided from those experiments. Several efficiencies were investigated to evaluate the performance of the thermal storage. The results concluded that the slab as a regenerator is very effective in cutting down peak loads of the office building.

공업로용 무화염식 축열버너의 국산화 개발 (The Development of Flameless Regenerative Burner for the Industrial Furnaces)

  • 김원배;양제복
    • 한국연소학회지
    • /
    • 제15권2호
    • /
    • pp.27-33
    • /
    • 2010
  • Recently, much attention has been paid to utilizing highly preheated air up to $1,000^{\circ}C$ through waste gas in industrial furnaces. The regenerative burner technology has shown to provide significant reduction in energy consumption (up to 60%), downsizing of the equipment (about 30%) and lower emissions (about 30%) while maintaining high thermal performance of the system since 2000. The object of this study is to develop the flameless regenerative burner for industrial furnaces based on the FLOX(Flameless Oxidation) principle and it has been designed and manufactured as pilot scale. Performance tests are experimentally done and their results are discussed. They showed 1) a very good uniformity in temperature distribution, 2) about 100 ppm in NOx at the temperature $1,300^{\circ}C$, 3) about 95% in temperature efficiency. Besides, the regenerative burner has advantage in easy maintenance and high usage rate of regenerator due to the separate and portable type of heat exchanger.

VM 열펌프의 3차해석 (A Third-order analysis of VM heat pumps)

  • 강영구;정은수
    • 설비공학논문집
    • /
    • 제9권2호
    • /
    • pp.229-238
    • /
    • 1997
  • A third-order simulation model of VM heat pumps has been developed. This model allows consideration of the major losses such as heat conduction losses through regenerators and displacers, pumping losses and wall-to-gas heat transfer losses in working volumes, in addition to the heat exchanger and regenerator losses. The working volume was divided into 12 control volumes and conservation equations of mass and energy were applied to each control volume. Pressure drop was considered in regenerators only. Thermodynamic behavior of working fluid in a VM heat pump was investigated and effects of major losses on the performance of a VM heat pump were shown.

  • PDF

A Third-order Simulation Model of a Vuilleumier Cycle Heat Pump

  • Kang, Young-Goo;Jeong, Eun-Soo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제6권
    • /
    • pp.80-92
    • /
    • 1998
  • A third-order simulation model of a Vuilleumier{VM) heat pump has been developed. This model takes into account the major losses such as the heat conduction losses through regenerators and displacers, the pumping losses and the wall-to-gas heat transfer losses in active volumes, in addition to the heat exchanger and regenerator losses. The working volume was divided into 12 control volumes and the conservation equations of mass and energy were applied to each control volume. Pressure drops were considered in regenerators only. Thermodynamic behavior of the working gas in a VM heat pump was investigated and effects of the major losses and operating conditions on the performance of a VM heat pump were shown.

  • PDF

재생기효율을 고려한 스터링기관의 예비설계 (The Preliminary Design of Stirling Engines Considering the Regenerator Effectiveness)

  • 유호선;노승탁
    • 대한기계학회논문집
    • /
    • 제14권5호
    • /
    • pp.1356-1364
    • /
    • 1990
  • 본 연구에서는 단열해석에 재생기효율을 고려함으로써 보다 합리적인 예비설 계조건을 도출하고자 함이다. 스터링기관용 재생기의 특성검토를 통하여 예비설계에 적합한 재생기효율을 정립하며, 기 발표된 단열모델에 대한 해석적 근사해에 적용하는 방법으로 접근한다. 재생기효율이 고려될 경우 기관의 기본형태와 연관된 위상각, 행정체적비, 불용체적비, 압축비등 설계인자의 최적조건에 관하여 취급하며 온도비, 비열비등 부여조건의 변화에 따른 영향을 검토한다.

스터링 사이클 기기 열교환기의 열전달 해석 (Heat transfer analysis on the heat exchanger of a stirling cycle machine)

  • 이대영;조관식;노승탁;강병하
    • 대한기계학회논문집B
    • /
    • 제20권4호
    • /
    • pp.1385-1394
    • /
    • 1996
  • A theoretical analysis was performed on the heat transfer by laminar oscillating flow in a simplified heat exchanger of a Stirling cycle machine and the results were compared with the experiment of Hwang. In the analysis the general solution to the temperature field obtained by Lee et. al was applied and extended to a more realistic situation. The results show that the heat transfer is influenced by the ratio of the swept distance of the fluid to the length of the heat exchanger as well as the oscillation frequency. This is well consistent with the result of Hwang's experiment. It is also revealed that there exist three distinct regimes having different heat transfer mechanisms. Through the scale analysis the main parameters governing the heat transfer in each regime are reduced and the dependency of the heat transfer on the parameters are examined.

액체 제습식 냉방 시스템의 최적 설계 (Optimization Design of Liquid Desiccant Cooling System)

  • 전동순;이상재;김선창;김영률;이창준
    • 설비공학논문집
    • /
    • 제22권7호
    • /
    • pp.419-428
    • /
    • 2010
  • This paper presents the optimization process of liquid desiccant cooling system using LiCl aqueous solution as a working fluid. Operating conditions(mass flow rate, conditioner outlet concentration, difference concentration) and design factors for heat exchangers(difference temperature of the district heating water, leaving temperature difference of the conditioner, leaving temperature difference of the regenerator, air temperature difference of the conditioner, air temperature difference of the regenerator) were optimized by response surface method. As a result, we obtained the 7.297 kW of cooling capacity and 0.788 of COP at optimized condition. Effect of difference temperature of hot water on system performances was also examined. As difference temperature of the district heating water increases, the cooling capacity increases and COP decreases.

Study on the Equilibrium Point of Heat and Mass Transfer between Liquid Desiccant and Humid Air with in the Solar Air Conditioning System

  • Sukmaji, I.C.;Rahmanto, H.;Agung, B.;Choi, K.H.;Kim, J.R.
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 추계학술발표대회 논문집
    • /
    • pp.161-167
    • /
    • 2009
  • The liquid solar air conditioning system is introduced as an alternative solution to control air condition and to save electrical energy consumption. The heat and mass transfer performances of dehumidifier/regenerator in liquid solar air conditioning system are influenced by air and desiccant condition. The application of this system, the thermal energy from the sun and inlet air are unable to control, but operation parameter of other components such as pump, fan and sensible cooling unit are able to control. The equilibrium point of heat and mass transfer are the liquid desiccant and inlet air conditions, where, the heat and mass are not transferred between the liquid desiccant and vapor air. By knowing equilibrium point of heat and mass transfer, the suitable optimal desiccant conditions for certain air condition are funded. This present experiment study is investigated the equilibrium point heat and mass transfer in various air and desiccant temperature. The benefit of equilibrium point heat and mass transfer will be helpful in choose and design proper component to optimize electrical energy consumption.

  • PDF

왕복유동조건에서 다공성 물질의 비정상 열전달 (Transient Heat Transfer in Porous Media under Oscillating Flow Condition)

  • 변수영;이대영;노승탁
    • 대한기계학회논문집B
    • /
    • 제25권3호
    • /
    • pp.422-432
    • /
    • 2001
  • An analytical characterization is presented on the transient heat transfer by an oscillating flow through a porous slab. Based on a two-equation model, analytic solutions are obtained for both the fluid and solid temperature variations. Two parameters are identified as the Stanton number for the internal heat exchange and the ratio of the thermal capacities between the solid and fluid phases. The heat transfer characteristics are shown to be classified into four regimes according to the two parameters and physical interpretation is presented on the particular heat transfer processes within each regime. In addition, the condition for the local thermal equilibrium between the phases is examined and the relevant criterion is suggested.

Experimental Study on Mass Transfer Rate at the Packed Column of Solar Cooling Liquid Desiccant System Using Counter Flow Configuration

  • Hengki R, R.;Choi, K.H.;Yohana, Eflita;Sukmaji, I.C.;Kim, J.R.
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 춘계학술발표대회 논문집
    • /
    • pp.155-161
    • /
    • 2009
  • Desiccant systems have been proposed as energy saving alternatives to vapor compression air conditioning for handling the latent load. Use of liquid desiccants offers several design and performance advantages over solid desiccants, especially when solar energy is used for regeneration. The liquid desiccants contact the gas inside the packed column and the heat transfer and mass transfer will occur. This proposal is try study the mass transfer and heat transfer inside the packed column of dehumidifier and regenerator systems. And later on, the rates of dehumidification and regeneration that were affected by desiccant flow rates, air temperature and humidity, and desiccant temperature and all that variation will influence the performance of the systems.

  • PDF