• Title/Summary/Keyword: Heat Plate

Search Result 1,877, Processing Time 0.027 seconds

Effect of Fin Pitch on Air Side Heat Transfer in Louvered-Fin Heat Exchanger (루우버핀 열교환기의 핀피치가 공기측 열전달에 미치는 영향)

  • Jang, B.J.;Kim, S.J.
    • Solar Energy
    • /
    • v.20 no.3
    • /
    • pp.31-38
    • /
    • 2000
  • In order to study on influence of fin pitch and shape of heat exchanger on the elevation of heat transfer efficiency, we make models of louvered fin type heat exchanger which was given a transformation of fin pitch in louvered fin type heat exchanger which are of en used now. And the influence of fin pitch on pressure drop and characteristics of heat transfer was experimented and analysed when air velocity and fin pitch was a variable. The results of experiment shows below. Pressure drop shows larger in louvered fin type heat exchanger than in plate fin type heat exchanger, size of pressure drop shows like this order that fin space is 4mm, 5mm, 6mm. Mean heat transfer coefficient shows higher in louvered fin type heat exchanger than in plate fin type heat exchanger, size of mean heat transfer coefficient by fin space shows same in both case in louvered fin type heat exchanger and plate fin type like this order that fin space is 4mm, 5mm, 6mm.

  • PDF

An Experimental Study on the Heat Transfer Characteristics for a Flat Plate Solar Collector with a Heat Pipe (열파이프가 부착된 평판형 태양열 집열기의 열전달 특성에 대한 실험적 고찰)

  • 김철주;임광빈
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.17 no.5
    • /
    • pp.1237-1245
    • /
    • 1993
  • In this study, a model of a flat plate solar collector using a heat pipe was manufactured and tested to investigate such operational characteristics of the present system of solar collector as start-up process, temperature distribution on the absorber plate and operation of the heat pipe. Moreover, collector efficiency was measured for 20-30 minutes of operation at various conditions of weather and the result was compared with that tested by Hill et. a. for a flat plate solar collector using direct circulation of coolant. Some results obtained in this study could be summarized as follows. (1) The required time for the initial start-up process was about 5-6 minutes, but the heat pipe began to operate as soon as the absorber plate was exposed to solar radiation. (2) On the absorber plate, the temperature distributions in axial direction maintained nearly constant, while temperature distributions in transversal direction showed smooth decrease with $3-5^{\cird}C$ along with solar radiation. (3) Thermal inertia of the collector system had a favorable effect to damp the turbulent variation of solar radiation. (4) The collector efficiency of the present system showed nearly the same tendency but a decrease of about 10% compared with that using direct circulation of coolant.

Effects of the secondary flow on the turbulent heat transfer of a flat plate wake (2차유동이 평판후류의 난류열전달에 미치는 영향)

  • Kim, Hyeong-Su;Lee, Jun-Sik;Gang, Sin-Hyeong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.22 no.4
    • /
    • pp.417-427
    • /
    • 1998
  • The effect of secondary flow on the heat transfer of a turbulent wake generated by a flat plate was experimentally investigated. The secondary flow was induced in a curved duct in which the flat plate wake generator was installed. All three components of turbulent heat flux were measured in the plane containing the mean radius of curvature of the curved duct. The results showed that mean temperature profiles deviate from the similarity of the straight wake because of the cold fluid transported from the free-stream. The half-width of the mean temperature profile increased rapidly by upwash motion of the secondary flow. The changes to turbulence structure caused by the secondary flow show more pronounced effect on heat transport than on momentum transport. This is because the response to the variation of flow conditions is delayed in temperature field. Negative production of the turbulent heat flux is observed in the inner wake region. From the conditional averaging, it has been found that the negative production of the turbulent heat flux is generated due to a mixing process between the hot and low momentum eddies occupied in the inner wake region and the cold and high momentum eddies in the potential region.

Modifications and Assessment of RELAP5/MOD3.2 for HANARO Thermal-Hydraulic Safety Analyses

  • Gee Yang Han;Kwi Seok Ha
    • Nuclear Engineering and Technology
    • /
    • v.34 no.5
    • /
    • pp.455-467
    • /
    • 2002
  • RELAP5/MOD3.2 was modified to perform the thermal-hydraulic safety analysis for HANARO transients. Several aspects of RELAP5/MOD3.2 were modified or replaced by new features to properly simulate the unique HANARO characteristics such as the finned fuel element, the cooling mechanisms by both plate type heat exchanger and the natural circulation. Especially, the heat transfer packages were modified to be more appropriate for the safety analysis and the heat transfer models were developed for the plate type heat exchanger as well as natural circulation through the pool water. This modified version of RELAP5/MOD3.2 is renamed as RELAP5/HANARO. The thermal-hydraulic simulations of the single fuel pin test and plate type heat exchanger were peformed to assess the realistic predicting capabilities of RELAP5/HANARO and compared with experimental results and manufacturer's data in this paper. In addition, the natural circulation experiment using the scaled bundle was simulated to validate the capability of RELAP5/HANARO. The simulation results show almost similar trend with experimental data. Therefore, it is proved that RELAP5/HANARO has a confidence to use for the safety analyses of HANARO.

A Numerical Analysis of Convective Heat Transfer in Air Flow Channels of a Plate Fin-tube Matrix for Heat Pipe Heat Sinks (히트파이프 히트싱크에서 평판 휜-관으로 구성된 공기유동 냉각채널의 대류 열전달 특성에 관한 수치해석)

  • Kim Sung-Hoon;Shin Hyun-Myung;Kim Chul-Ju
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.29 no.8
    • /
    • pp.862-869
    • /
    • 2005
  • A study on convective cooling characteristics has been done in the channels with heat pipes and associated Plane fins Analysis with FLUENT V5.0 lies its Purpose on the possible enhancement of heat transfer capability between an existing three in-line arrayed heatpipes and an extending four in-line arrayed heatpipes with increasing channel width. Numerical analysis is limited to the laminar flow in an isolated flow channel by employing cyclic boundary conditions for calculation purposes. Friction factors for three and four in-line arrayed heatpipes are compared with experimental results. In addition, temperature behavior at the plate fin for the three in-line arrayed heatpipes is compared with experiment. Friction factors and overall channel heat transfer coefficients (and/or Nusselt numbers) are presented as a function of Reynolds number. An increase of number of heatpipes and channel width reults in a decrease of the friction factor and doesn't not result in an increase of heat transfer performance. However. considering the 25$\%$ increase of heat load accompanies with maximum 8$^{\circ}C$ rise of average temperature of heat pipes, the four in-line array with the increase of channel width of heat pipe heat sink can be considered appropriate.

Air-Side Performance of Fin-and-Tube Heat Exchanger with Copper Plate or Copper Spiral Fins (구리 재질의 평판 핀과 나선형 핀이 사용된 핀-관 열교환기의 공기측 성능)

  • Lee, Jin-Wook;Park, Ji-Hoon;Lee, Jung-Pyo;Kim, Nae-Hyun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.3
    • /
    • pp.269-278
    • /
    • 2011
  • We investigate the heat-transfer and pressure-drop characteristics of fin-and-tube heat exchangers with a copper plate or copper spiral fins. Twenty-four samples with different fin pitches and tube rows were tested. For both configurations, the effect of the fin pitch on the j factor is negligible, and the f factor increases with the fin pitch. The effect of the tube row depends on the configuration. For plate fin-and-tube heat exchangers, the j factor decreases as the row number increases; the reverse is true for spiral exchangers. We explain this by considering the flow pattern. The j factor for plate fin-and-tube heat exchangers is larger than that for spiral exchangers, and the difference decreases as the row number increases. The f factor of the plate fin-and-tube heat exchanger is also larger. We compare our results with existing predictions of correlations.

Structural Design and Manufacturing of Corrugated Plate for Plate-Type Heat Exchanger (연속 주름구조를 가진 전열판의 기계적 건전성 확보를 위한 형상 설계 및 제작)

  • Yu, Jae Hyun;Bae, Won Byong;Park, Sang Hu;Cho, Jong Rae;Jeong, Ho Seung
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.33 no.3
    • /
    • pp.199-205
    • /
    • 2016
  • A thin sheet of metal with corrugated structures has been utilized in various devices: heat exchangers, separators in fuel cells, and many others. However, it is not easy to fabricate thin corrugated structures using a single-step stamping process due to their geometrical complexity. To solve this problem, firstly, a plate type heat exchanger was redesigned to attain the optimal value of aspect ratio and the optimal shape of corrugated structures for the actual loading conditions. A forming analysis of the corrugated plate was then carried out to determine the process parameters. From this work, the optimal value of aspect ratio was found to be 4.6. In addition, the process parameters of heat exchanger forming were optimized using the optimal value of aspect ratio, and the analytical results were evaluated through experiments. The results obtained indicated good agreements between them.

The Measurements of Ball Recovery Rate for the Cleaning Apparatus in Plate Heat Exchanger Using Ceramic Ball (세라믹 볼을 이용한 판형열교환기 세정장치의 볼 회수율 측정)

  • Chae, Hee-Man;Kwon, Jeong-Tae;Cha, Dong-An;Kwon, Oh-Kyung
    • Journal of Power System Engineering
    • /
    • v.18 no.1
    • /
    • pp.38-44
    • /
    • 2014
  • The objectives of this study are to measure the ball recovery rate of cleaning apparatus for plate heat exchanger. Ceramic ball is used for plate heat exchanger cleaning. The main components of cleaning apparatus are comprised of ball collector, ball trap, ejector, pump and plate heat exchanger. The ball recovery rate are obtained with change in recovery time and velocity of water. The results show that the ball recovery rate is slightly increased with increase in the recovery time and the velocity of water over 0.4 m/s in the straight flow. In the case of reverse flow, the ball recovery rate more increased than straight flow. The maximum ball recovery rate of the straight flow and reverse flow reach 83.97% and 86.61%, respectively, when the velocity and cleaning time are 0.5 m/s and 15min.

Experimental study on the performance improvement of a screw-compressor-type chiller (스크류 압축식 냉동기의 성능향상에 관한 실험적 연구)

  • Lee, D.-Y.;Jung, S.-H.;Kang, B.H.;Hong, H.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.1
    • /
    • pp.48-60
    • /
    • 1999
  • An experimental study on the performance enhancement of a screw-compressor-type chiller with 100kW of nominal cooling capacity has been carried out. Performance test facility was developed to investigate the effects of a partial modification from the existing chiller on the performance. By replacing the existing shell-and -tube heat exchangers with plate heat exchangers, the cooling capacity is increased by 15~18% and the COP is also increased by 19~21% depending on the operation temperature range. Charging mixed refrigerant R22/R142b(80 : 20) instead of R22 into the chiller with plate heat exchangers improves the cooling capacity by 4% and the COP very largely by 30%. Each contribution of the plate evaporator, plate condenser, and mixed refrigerant to the performance enhancement is examined by analyzing the refrigeration cycle and the heat transfer processes. It is also shown that the chiller performance can be improved by adapting 2-stage-compression cycle using an economizer.

  • PDF

Comparison of Performance Characteristics in the Chevron Type Plate Heat Exchanger with Performance Correlation (성능 예측 상관식에 따른 쉐브론 형태 판형 열교환기 성능 특성 비교)

  • Bae, Kyung-Jin;An, Sung-Kuk;Cho, Hyun-Uk;Nam, Sang-Chul;Cho, Hong-Hyun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.8
    • /
    • pp.535-542
    • /
    • 2011
  • The performance of a plate heat exchanger for using liquid solution in the absorption chiller-heater was analyzed. The model was developed by using the various performance prediction correlations. The performance characteristics of the plate heat exchanger with the mass flow rate ratio was verified by using experimental data. To investigate performance of plate heat exchanger with geometry variables, the chevron angle, corrugated wave length, and corrugation depth were changed. As a result, the capacity of Kim and Martin correlation models was similar with the experimental data, and the capacity difference was less than 2%. Besides, the pressure drop of Marin correlation model showed a similar variation with experimental data, and the difference of pressure drop was less than 1.5 kPa.