• Title/Summary/Keyword: Heat Management Unit

Search Result 48, Processing Time 0.058 seconds

Development of a Bi-Directional Security Light Control System based on Low-Bandwidth Wireless Sensor Network (저대역 센서 네트워크 기반의 양방향 보안등 관제 시스템 개발)

  • Lee, Ho-Gun;Lee, Sang-Ho;Lee, Suk-Gyu;Choi, Jeong-Won
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.10
    • /
    • pp.58-66
    • /
    • 2010
  • This paper shows an implementation and management result of wireless networks based security light control system, which performs a great role in protection of pedestrians and prevention of crime. Conventional security light units have severe limits in confirmation and inspection of security light unit failure, like wilful damage by someone or failure by influence of other equipment or failure by spontaneous heat-increase, and so on. In addition, local government offices are responsible for maintenance of security light units and as a matter of fact, most of civil complaints are about security light units. It is an obvious that the existing security light maintenance system reaches the limit and the security light maintenance problem is a difficulty of local government. Therefore, efficient security light control system is needed, which enables central control and intelligent maintenance. Moreover, the system has to be easy to control and has to be stable. In this study, wireless sensor network based security light control system is implemented, which is independent of programming language and platform, and which is simple to control and extend the system. The proven protocols, HTTP and SOAP, are utilized in order to improve the system reliability. This paper shows the excellence of our proposed system by implementing and operating it in real environment.

Optimum Mix Proportion of the High Strength and Self Compacting Concrete Used Above-Ground LNG Storage Tank (지상식 LNG 저장탱크용 고강도 자기충전 콘크리트의 최적배합에 관한 연구)

  • Kwon, Yeong-Ho
    • Journal of the Korea Concrete Institute
    • /
    • v.23 no.1
    • /
    • pp.99-107
    • /
    • 2011
  • This study is to performed to find the optimum mix proportion of the high strength and self compacting concrete for the above-ground LNG storage tank construction and field application. If LNG storage tank wall thicknesscan be reduced, the construction cost and quality can be improved by using self-compacting high strength concrete with compressive strength 60~80 MPa. For this purpose, low heat cement (Type IV) and class F fly ash are used in concrete mix to control hydration heat, flowability, and viscosity. Mix design variables of unit water, fly ash replacement ratio, water-binder ratio, and fine aggregate ratio are selected and tested for material properties and manufacturing cost of the concrete. Also, fly ash replacement ratio is considered using confined water ratio test. The test results showed that the optimum mix proportion of the self-compacting high strength concrete characteristics are as follows. 1) In case of the concrete with specified compressive strength of 60 MPa, the optimum mix proportion is fly ash replacement ratio of 20% and water- binder ratio of 27~30%. 2) In case of the concrete with the strength of 80 MPa, the optimum mix proportion is fly ash replacement ratio of 10% and water-binder ratio 25%. But unit water and fine aggregate ratio are 165 $kg/m^3$ and $51{\pm}2%$, respectively, regardless of the traget concrete compressive strength range. Also, test results showed that concrete manufacturing cost of 60 MPa and 80 MPa concrete require additional costs of 14~22% and 33%, respectively, compared to the manufacturing cost of 40 MPa concrete. Therefore, application of the self-compacting high strength concrete has proven to be economical in the perspective of the material cost, quality control, and site management.

Estimation of Energy Recovery Rate of Municipal Waste Incineration Facilities through Measuring Instruments (계측기기 측정을 통한 생활폐기물 소각시설의 에너지 회수효율 산정 연구)

  • Kwon, Young-Hyun;Kang, Jun-Gu;Ko, Young-Jae;Yoo, Ha-Nyoung;Kwon, Jun-Hwa;Park, Ho-Yeun;Jeon, Tae-Wan;Lee, Young-Ki
    • Journal of Korea Society of Waste Management
    • /
    • v.35 no.8
    • /
    • pp.770-776
    • /
    • 2018
  • This study measured the energy recovery rate of each municipal waste incineration facility according to the revised energy recovery rate estimation method, which targeted four municipal waste incineration facilities (Unit No. 7). The results calculated by the measuring instruments were used for each factor to estimate the recovery rate, and the available potential of available energy was examined by analyzing the energy production and valid consumption. As a result of the low heating value, 2,540 kcal/kg was calculated on average when the LHVw formula was applied, which is approximately 116 kcal/kg higher than the average design standard of 2,424 kcal/kg. The energy recovery rate was calculated as 96.9% on average based on production and 67.5% based on effective consumption, and the analysis shows that approximately 29.4% energy can be used.

Comparison of Environmental Evaluation for Paper and Plastic Based Mask Packaging (종이 기반과 플라스틱 기반 보건마스크 패키징의 환경영향 비교)

  • Dongho Kang;Youjin Go;Sanghoon Oh;Gohyun Choo;Jisoo Jang;Junhyuk Lee;Jinkie Shim
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.30 no.1
    • /
    • pp.73-83
    • /
    • 2024
  • In this study, environmental evaluation of high barrier coated paper (coating layer/paper) packaging is conducted in comparison with conventional aluminum laminated (PET/VMPET/LLDPE) plastic packaging. The target product for this packaging is a KF94 mask, which requires a high barrier of water and oxygen to maintain the filtration ability of the mask filter. The functional unit of this study is 10,000 mask packaging materials based on a material capable of blocking oxygen (<1 g/m2day) and moisture (<3 g/m2day) for the preservation of KF94 masks. In order to understand the results easily, paper-based mask packaging system divided into 6 stages (pulp, pulping & paper making, calendaring & coating, printing, packing and waste management), while plastic-based mask packaging consists of 5 stages (material production, processing, printing, packing, waste management) In case of paper-based mask packaging, most contributing stage is calendaring & coating, resulting from heat and electricity production. On the other hand, plastic-based mask packaging is contributed more than 30% by material production, specifically due to linear low density polyethylene and purified terephthalic acid production. The comparison results show that global warming potential of paper-based mask packaging has 32% lower than that of plastic-based mask packaging. Most of other impact indicators revealed in similar trend.

Simulation of Spatio-Temporal Distributions of Winter Soil Temperature Taking Account of Snow-melting and Soil Freezing-Thawing Processes (융설과 토양의 동결-융해 과정을 고려한 겨울철 토양온도의 시공간 분포 모의)

  • Kwon, Yonghwan;Koo, Bhon K.
    • Journal of Korea Water Resources Association
    • /
    • v.47 no.10
    • /
    • pp.945-958
    • /
    • 2014
  • Soil temperature is one of the most important environmental factors that govern hydrological and biogeochemical processes related to diffuse pollution. In this study, considering the snowmelting and the soil freezing-thawing processes, a set of computer codes to estimate winter soil temperature has been developed for CAMEL (Chemicals, Agricultural Management and Erosion Losses), a distributed watershed model. The model was calibrated and validated against the field measurements for three months at 4 sites across the study catchment in a rural area of Yeoju, Korea. The degree of agreement between the simulated and the observed soil temperature is good for the soil surface ($R^2$ 0.71~0.95, RMSE $0.89{\sim}1.49^{\circ}C$). As for the subsurface soils, however, the simulation results are not as good as for the soil surface ($R^2$ 0.51~0.97, RMSE $0.51{\sim}5.08^{\circ}C$) which is considered resulting from vertically-homogeneous soil textures assumed in the model. The model well simulates the blanket effect of snowpack and the latent heat flux in the soil freezing-thawing processes. Although there is some discrepancy between the simulated and the observed soil temperature due to limitations of the model structure and the lack of data, the model reasonably well simulates the temporal and spatial distributions of the soil temperature and the snow water equivalent in accordance with the land uses and the topography of the study catchment.

Optimization of Fuel Processing Unit of Fuel Cell System using Six-Sigma Technique (Six-sigma 기법을 이용한 연료전지시스템 연료저리장치 최적화)

  • Chung, Kyung-Yong;Kim, Sun-Hoe
    • Journal of Digital Convergence
    • /
    • v.10 no.2
    • /
    • pp.225-229
    • /
    • 2012
  • A reformer for a small fuel cell system is an apparatus which converts hydrocarbon fuel into hydrogen-rich gas. Among many indices of a reformer, the most crucial index of a reformer is CO concentration in the off-gas out of reformer which must be controled under 5ppm for the efficiency and performance of a system. This paper suggests the criteria of a reformer operation for the stability of a reformer in a fuel cell system by deducing crucial indices and improving processes. The six-sigma technique was applied to verify the optimum control and operation of a reformer of a fuel cell combined heat and power system. The result of temperature control of each parts of a reformer system is the concentration of CO which is the most important factor for the operation of a fuel cell system. The temperature of the parts of a reformer, MTS, LTS and Prox, were controled so that the concentration of CO.

Anti-Heat Shock Protein-27 Antibody Levels in Women with Breast Cancer: Association with Disease Complications and Two-Year Disease-Free Survival

  • Homaei-Shandiz, Fatemeh;Mehrad-Majd, Hassan;Tasbandi, Mojtaba;Aledavood, Amir;Afshari, Jalil Tavakol;Ghavami, Vahid;Ghayour-Mobarhan, Majid
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.10
    • /
    • pp.4655-4659
    • /
    • 2016
  • Background and Aim: Breast cancer is a major healthcare problem in women. There are many reports about up-regulation of Hsp27 in cancer tissues but less is known about the potential relationship between Hsp27 antibody levels and breast cancer complications. We here investigated concentrations of serum Hsp27 antigen and antibodies in subjects with and without breast cancer and assessed potential associations with two-year disease-free survival, histological grade and number of lymph nodes. Materials and Methods: Specifically, serum Hsp27 antigen and antibody levels from 97 patients with breast cancer, and 65 healthy controls were determined by enzyme-linkedimmunosorbent assays (ELISAs). Results: Serum Hsp27 and antibody levels were significantly (p<0.001) higher in patients with breast cancer compared to the control group, but no relationship were found with two-year disease free survival, histological grade or number of lymph nodes (p> 0.6, 0.2 and 0.9 respectively). Conclusions: Elevated levels of Hsp27 antibody occur with women with breast cancer but do not appear to be associated with the presence of disease clinical complications.

Deicing Performance of Environment-friendly Deicing Agents (친환경 제설제인 CMO의 성능평가 분석)

  • Lee, Seung-Woo;Woo, Chang-Wan;Kim, Jong-Oh;Park, Hee-Mun
    • International Journal of Highway Engineering
    • /
    • v.7 no.3 s.25
    • /
    • pp.53-62
    • /
    • 2005
  • Efficient snow-removing work is one of important processes of winter road management. Calcium chloride has been used as a typical deicing agent in Korea. It presents superial performance as snow deicing agents, however it has been known to give serious environmental problem and to deteriorate durability of concrete structure in road by corrosion. The environment-friendly road deicing agents made from the waste material which is liquid phase organic matter that is Ca Mg and reactant of organic acid (nitric acid and propionic acid) have been introduced by number of researchers. They indicated the calcium magnesium salt of organic acids have advantage over the calcium choride in terms of lower production unit cost by resources recycling and can solve environmental problem and durability deterioration of structures. In this study, the deicing performance of calcium magnesium salt of organic acids(CMO) is investigated based on the series of experiments including the test for heat of dissolution, freezing point, ice melting test and ice penetration test.

  • PDF

Effect of Gas Diffusion Layer Property on PEMFC Performance (기체확산층 물성이 고분자전해질 연료전지 성능에 미치는 영향)

  • Kim, Junseob;Kim, Junbom
    • Applied Chemistry for Engineering
    • /
    • v.31 no.5
    • /
    • pp.568-574
    • /
    • 2020
  • Gas diffusion layer (GDL) is one of the main components of PEMFC as a pathway of reactants from a flow field to an electrode, water transport in reverse direction, heat management and structural support of MEA. In this study, the effect of GDL on fuel cell performance was investigated for commercial products such as 39BC and JNT30-A3. Polarization curve measurements were performed at different flow rates and relative humidity conditions using 25 ㎠ unit cell. The parameters on operating conditions were calculated using an empirical equation. The electrical resistance increased as the GDL PTFE content increased. The crack of microporous layer had influence on the concentration loss as water pathway. In addition, the ohmic resistance increased as the relative humidity decreased, but decreased as the current density increased due to water formation. Curve fitting analysis using the empirical equation model was applied to identify the tendency of performance parameters on operating conditions for the gas diffusion layer.

Computational Fluid Dynamics Study on Uniform Cooling of Polymer Electrolyte Membrane Fuel Cells by Parallel Multi-pass Serpentine Flow Fields (병렬 사형유로를 채택한 냉각판을 통한 고분자 전해질 연료전지의 균일 냉각에 대한 전산유체역학 해석 연구)

  • Yu, Seung-Ho;Baek, Seung-Man;Nam, Jin-Hyun;Kim, Charn-Jung
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.10
    • /
    • pp.885-891
    • /
    • 2010
  • Thermal management is important for enhancing the performance and durability of polymer electrolyte membrane fuel cells (PEMFCs) and is taken into account in the design of PEMFCs. In general, cooling pates with circulating liquid coolant (water) are inserted between several unit cells to exhaust the reaction heat from PEMFCs. In this study, computational fluid dynamics (CFD) simulations were performed to characterize the uniform cooling performance of parallel multipass serpentine flow fields (MPSFFs) that were used as coolant flow channels in PEMFCs. The cooling performances of conventional serpentine and parallel flow fields were also evaluated for the purpose of comparison. The CFD results showed that the use of parallel MPSFFs can help reduce the temperature nonuniformity, and thus, can favorably enhance the performance and durability of PEMFCs.