• 제목/요약/키워드: Heat Load

검색결과 1,728건 처리시간 0.029초

Hydraulic Behaviors of KSTAR PF Coils in Operation

  • Park, S.H.;Chu, Y.;Kim, Y.O.;Yonekawa, H.;Chang, Y.B.;Woo, I.S.;Lee, H.J.;Park, K.R.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제14권2호
    • /
    • pp.24-27
    • /
    • 2012
  • The superconducting coil system is one of the most important components in Korea Superconducting Tokamak Advanced Research (KSTAR), which has been operated since 2008. $Nb_3Sn$ and NbTi superconductors are being used for cable-in-conduit conductors (CICCs) of the KSTAR toroidal field (TF) and poloidal field (PF) coils. The CICCs are cooled by forced-flow supercritical helium about 4.5 K. The temperature, pressure and mass flow rate of the supercritical helium in the CICCs are interacting with each other during the operation of the coils. The complicate behaviors of the supercritical helium have an effect on the operation and the efficiency of the helium refrigeration system (HRS) by means of, for instance, pressure drop. The hydraulic characteristics of the supercritical helium have been monitored while the TF coils have stably achieved the full current of 35 kA. In other hands, the PF coils have been operated with various pulsed or bipolar mode, so the drastic changes happen in view of hydraulics. The heat load including AC loss on the coils has been analyzed according to the measurement. These activities are important to estimate the temperature margin in various PF operation conditions. In this paper, the latest hydraulic behaviors of PF coils during KSTAR operation are presented.

Commissioning result of the KSTAR in-vessel cryo-pump

  • Chang, Y.B.;Lee, H.J.;Park, Y.M.;Lee, Y.J.;Kwag, S.W.;Song, N.H.;Park, D.S.;Joo, J.J.;Moon, K.M.;Kim, N.W.;Yang, H.L.;Oh, Y.K.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제15권4호
    • /
    • pp.53-58
    • /
    • 2013
  • KSTAR in-vessel cryo-pump has been installed in the vacuum vessel top and bottom side with up-down symmetry for the better plasma density control in the D-shape H-mode. The cryogenic helium lines of the in-vessel cryo-pump are located at the vertical positions from the vacuum vessel torus center 2,000 mm. The inductive electrical potential has been optimized to reduce risk of electrical breakdown during plasma disruption. In-vessel cryo-pump consists of three parts of coaxial circular shape components; cryo-panel, thermal shield and particle shield. The cryo-panel is cooled down to below 4.5 K. The cryo-panel and thermal shields were made by Inconel 625 tube for higher mechanical strength. The thermal shields and their cooling tubes were annealed in air environment to improve the thermal radiation emissivity on the surface. Surface of cryo-panel was electro-polished to minimize the thermal radiation heat load. The in-vessel cryo-pump was pre-assembled on a test bed in 180 degree segment base. The leak test was carried out after the thermal shock between room temperature to $LN_2$ one before installing them into vacuum vessel. Two segments were welded together in the vacuum vessel and final leak test was performed after the thermal shock. Commissioning of the in-vessel cryo-pump was carried out using a temporary liquid helium supply system.

농작업화에 관한 연구 - 신발종류에 따른 열적 부담 비교연구 - (A study of Agricultural fatigue shoes - A comparative study of heat load by shoe type -)

  • 이경숙;최정화
    • 한국농촌생활과학회지
    • /
    • 제7권2호
    • /
    • pp.99-108
    • /
    • 1996
  • This study has intended to suggest fundamental data to develope and choose appropriate shoes for upland farming in order to prevent health deterioration of women workers and improve work effectiveness and reduce fatigue by wearing appropriate shoes. During 1995. 4. 28 - 5. 10, Fifty women workers in hot pepper farming were observed and major shoe types, which were rubber shoes, walking shoes, slippers, and rubber boots, were selected for the study. During 1995. 10. 9 - 31, two subjects were tested by wearing those shoes in the laboratory where the temperature was 24$\pm$1$^{\circ}C$ and relative humidity 50$\pm$5%RH. And the temperature & humidity on sole and in the shoes, the rectal temperature, skin temperature, blood pressure, pulse, lactate concentration of blood, Flickers' value and subjective sensation were measured. The results were as follows : 1. 84% of women workers mentioned that they need shoes improvement and the order of most frequent shoe types to be worn was rubber shoes, walking shoes, slippers, rubber boots. 2. The rate of women who were unsatisfied with shoes for upland farming is 38 percentages. The reason of unsatisfaction was that feet were in a sweat and alien substances were let into shoes. 3. The temperature & humidity on sole were the lowest in rubber boots during experiment(p<0.01). 4. The relative humidity in the shoes was the highest in rubber boots by 90% and the lowest in walking shoes by 72% during rest And the humidity in slippers and walking shoes were significantly low in experiment(p<0.001). 5. Rubber boots showed the highest rise in rectal temperature by 0.2$^{\circ}C$ showing increase of core temperature (p<0.05). 6. The mean skin temperature during experiment was highest in rubber boots by 33.8$^{\circ}C$(p<0.001).

  • PDF

미소시험편을 이용한 고온 크리프 특성 평가법 개발 (Development of High Temperature Creep Properties Evaluation Method using Miniature Specimen)

  • 유효선;백승세;이송인;하정수
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집A
    • /
    • pp.43-48
    • /
    • 2000
  • In this study, a small punch creep(SP-Creep) test using miniaturized specimen$(10{\times}10{\times}0.5mm)$ has been described for the development of the newly semi-destructive creep test method for high temperature structural components such as headers and tubes of boiler turbine casino and rotor and reactor vessel. The SP-Creep testing technique has been applied to 2.25Cr-1Mo(STBA24) steel used widely as boiler tube material and the creep test temperature are varied at $550^{\circ}C{\sim}600^{\circ}C$. The overall deformations of SP-Creep curves are definitely depended with applied load and creep test temperature and show the creep behaviors of three steps like conventional uniaxial creep curves. The steady state creep rate${\delta}_{ss}$ of SP-Creep curve for miniaturized specimen increases with increasing creep temperature, but the exponential value with creep loading is decreased. The activation energy$(Q_{spc})$ during SP-Creep deformation with various test temperatures shows 605.7kJ/mol that is g.eater than 467.4kJ/mol reported in uniaxial creep test. This may be caused by the difference of stress states during creep deformation In two creep test. But from the experimental results, e.g. SP-Creep curve behaviors, the steady state creep rate${\delta}_{ss}$ with creep temperature, and the exponential value(n) with creep loading, it can be summarized that the SP-Creep test may be a useful test method to evaluate the creep properties of the heat resisting material.

  • PDF

선박용 디젤 엔진 크랭크 스로 부품용 S34MnV강의 피로한도에 대한 신뢰도 예측 (Prediction of Reliability of Fatigue Limit of S34MnV Steel for Marine Diesel Engine Crank Throw Components)

  • 김선진;공유식
    • 대한기계학회논문집A
    • /
    • 제40권8호
    • /
    • pp.751-757
    • /
    • 2016
  • 본 논문은 스테어케이스법을 사용하여 크랭크 스로 부품용 S34MnV강의 피로한도의 신뢰도를 평가하는 것이다. 크랭크 스로 부품의 소재는 S34MnV이며, 뜨임 및 풀림 열처리된 단조강이다. 본 연구에서는 설계피로강도의 신뢰도를 예측하기 위해 축 하중 일정진폭 피로시험을 수행하였다. 시험편은 평균응력 0 MPa의 동일한 응력부하를 적용하였고, 즉 응력비는 -1로 하였다. 피로시험 결과는 Dixon-Mood 접근법으로 평가하였다. 스테어케이스법에 의해 예측된 피로강도의 평균과 표준편차는 각각 296.3 MPa 및 10.6 MPa로 나타났다. 마지막으로 어떤 임의의 파손 확률에 대한 피로강도의 신뢰도를 예측하였다. 본 연구에서 제안한 예측법은 단조강의 설계 최적화를 위한 피로강도 값을 결정할 수 있다.

발전소용 유압기기의 마모특성 연구 (Study of Wear Characteristics of Hydraulic Equipment Used in Power Plants)

  • 이용범;이기천;장무성
    • 대한기계학회논문집A
    • /
    • 제37권9호
    • /
    • pp.1183-1188
    • /
    • 2013
  • 발전소에서 발생하는 고장은 인명 및 재정적 손실에 대한 파급효과는 매우 크므로 발전소에 사용되는 유압기기의 신뢰성은 특히 중요하다. 본 연구에서는 발전소용 유압밸브의 스풀과 슬리브 재질을 사용하여 시편을 제작, 열처리한 후 인산에스테르계열 유압작동유 침전상태에서 다양한 조건에서 실험한다. 시편의 마모량에 영향을 주는 인자들의 유의성을 평가하기 위해 $2^3$ 완전 요인 실험계획법을 적용하였으며, 고려된 인자들은 하중, 속도, 온도이다. 실험결과로부터 마모량에 대한 주효과 및 2 인자 교호작용에 대한 유의성 평가를 실시한 후 마모량과 인자들간의 수학적 모형을 도출하고자 한다.

Current and voltage loading tests off resistive SFCL

  • 최효상;현옥배;김혜림;황시돌;박권배
    • Progress in Superconductivity
    • /
    • 제3권2호
    • /
    • pp.241-246
    • /
    • 2002
  • We have performed the current and voltage loading tests of resistive superconducting fault current limiters (SFCLS) based on $YBa_2$$Cu_3$$O_{7}$(YBCO) films with the diameter of 2 inch. The SFCL consists of meander-type YBCO stripes covered with 200 nm Au layer grown in situ for current shunt and heat dispersion at hot spots. The minimum quench current of an SFCL unit was about 25 Apeak. Seven SFCL units were connected in parallel fur the current load ing tests at power source of 100 $V_{rms}$ $/2,000A_{rms}$. This SFCL units had maximum limiting current of 170 Apeak during the fault instant and then successfully controlled the fault current below 100 Apeak within 1~2 msec after short circuit. Increased short current also reduced the quench completion time with little change of current limiting characterization. We connected six SFCL units in series fur the voltage loading tests at power source of $1,200 V_{rms}$/170 $A_{rms}$ at this time. The shunt resistors were inserted into each SFCL unit to eliminate power imbalance originated from serial connection of SFCL units. Each SFCL unit was quenched simultaneously during the fault condition. The current increased up to 40 $A_{peak}$ and decreased to 14 $A_{peak}$ after 3 cycles. Quench was completed within 1 msec after the fault. We confirmed operating characteristics of 140 kVA($120 A_{rms}$ $\times$ 1,200 $V_{rms}$) SFCL and presented the manufacturing possibility of 3.3 kV SFCL using 4 inch YBCO films.BCO films.lms.

  • PDF

적외선 열화상 카메라를 이용한 탄소강관 용접부 결함검출 (Defect Detection of Carbon Steel Pipe Weld Area using Infrared Thermography Camera)

  • 권대주;정나라;김재열
    • Tribology and Lubricants
    • /
    • 제30권2호
    • /
    • pp.124-129
    • /
    • 2014
  • The piping system accounts for a large portion of the machinery structure of a plant, and is considered as a very important mechanical structure for plant safety. Accordingly, it is used in most energy plants in the nuclear, gas, and heavy chemical industries. In particular, the piping system for a nuclear plant is generally complicated and uses the reactor and its cooling system. The piping equipment is exposed to diverse loads such as weight, temperature, pressure, and seismic load from pipes and fluids, and is used to transfer steam, oil, and gas. In ultrasound infrared thermography, which is an active thermography technology, a 15-100 kHz ultrasound wave is applied to the subject, and the resulting heat from the defective parts is measured using a thermography camera. Because this technique can inspect a large area simultaneously and detect defects such as cracks and delamination in real time, it is used to detect defects in the new and renewable energy, car, and aerospace industries, and recently, in piping defect detection. In this study, ultrasound infrared thermography is used to detect information for the diagnosis of nuclear equipment and structures. Test specimens are prepared with piping materials for nuclear plants, and the optimally designed ultrasound horn and ultrasound vibration system is used to determine damages on nuclear plant piping and detect defects. Additionally, the detected images are used to improve the reliability of the surface and internal defect detection for nuclear piping materials, and their field applicability and reliability is verified.

국내 랙크식 창고의 방화관련 규정 개선에 관한 연구 (An Improvement of Fire Safety Code for Rack-Type Warehouse in Korea)

  • 김운형;이영재
    • 한국화재소방학회논문지
    • /
    • 제28권6호
    • /
    • pp.69-75
    • /
    • 2014
  • 최근 발생한 아모레퍼시픽 창고화재는 국내 랙크식 창고의 자동식소화설비 및 감지기 설치기준의 보완 및 개선의 필요성을 제시하고 있다. 물류창고는 보관물품에 따라 화재 확산율 및 열 방출비율이 다르며 저장높이, 랙크 배치, 통로폭, 물품의 양 등에 따라서 화재위험성이 결정된다. 고천정화에 따른 화재하중의 증가로 인하여 자동식 스프링클러설비가 작동하여도 가연물에 직접적인 침투효과에 한계가 있으며 화재감지기의 작동시간이 지연되어 초기소화에 실패할 확률이 높아진다. 이를 위하여 본 연구에서는 화재사례 및 국내외 관련규정비교 그리고 현장조사 등을 수행하여 랙크식 창고의 초기소화 및 제어성능을 확보하기 위한 수용물품의 위험도 분류 및 스프링클러 설치기준 개선방향과 화재피해를 최소화하기 위한 제도적 도입을 제안한다.

일반구조용 강재(SS 400)기둥부재의 경계조건과 부재 길이변화에 따른 고온 내력의 해석적 연구 (An Analytic Study on Structural Stability according to Boundary Conditions and H-section Column Lengths Made of An Ordinary Grade Structural Steels (SS 400) at High Temperatures)

  • 권인규
    • 한국화재소방학회논문지
    • /
    • 제28권1호
    • /
    • pp.20-25
    • /
    • 2014
  • 강구조 건축물의 기둥부재 내화성능은 접합부의 경계조건과 기둥부재의 길이에 따라 변화되지만, 내화성능 평가는 실험장비의 제약과 기술적 요인으로 인하여 힌지단과 3500 mm 길이 조건으로 이루어지고 있다. 그러나 실제 강구조물에 적용되는 기둥부재는 부지조건과 설계조건에 따라 다양한 경계조건과 길이의 변화를 가져올 수 있으며, 이에 대한 내화성능의 평가는 대상으로 고온 시의 재료특성과 해석적 이론을 바탕으로 고온 시 구조적 성능을 평가하여, 경계조건과 길이 변화에 따른 내화성능의 기본 자료를 도출하였다.