• 제목/요약/키워드: Heat Generation

검색결과 1,811건 처리시간 0.03초

디젤발전 자켓냉각시스템 열성능 향상 연구 (Performance Research of a Jacket Cooling Water System in a Diesel Electric Generation)

  • 이재근;문전수;윤석원;박필양
    • 한국수소및신에너지학회논문집
    • /
    • 제20권6호
    • /
    • pp.534-539
    • /
    • 2009
  • One of the most efficient techniques improving the heat transfer performance of a diesel electric generation is a corrosion control in jacket cooling water system. The environmental parameters most affecting corrosion are dissolved salt concentration, temperature, and pH of cooling water. No corrosion occurs in carbon steel probe at pH 11 in normal operating condition of diesel electric generation cooling water. pH control agent in this study is trisodium phosphate. pH control appears to be the most convenient way to enhance the thermal performance of a diesel electric generation.

빌딩 마이크로그리드가 포함된 새로운 빌딩에너지 시스템 구축방향에 관한 연구 (The Novel Configuration for Building Energy System Including Build ins Microgrid)

  • 홍원표
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2008년도 추계학술대회 논문집
    • /
    • pp.235-240
    • /
    • 2008
  • The recent development of efficient thermal prime movers for distributed generation id changing the focus of the production of electricity from large centralized power plants to local generation units scattered over the territory. The scientific communality is addressing the analysis and planning of the distributed energy resources(der) with wide spread approaches, taking into account technical, environmental, economical and social issues. The coupling of cogeneration system to absorption/electric chillers or heat pumps as well as the interactions with renewable sources, allow for setting up multi-generation systems for building cooling heating and power(BCHP) systems of different energy vectors such as electricity, heat(at different enthalpy levels), cooling power, hydrogen, various chemical substances and so forth. Adoption of the composite multi-generation systems may lead to significant benefits in term of higher efficiency, reduced $CO_2$ emissions and enhanced economy. This paper outlines the main aspects of the BCHP system framework, illistrating its characteristics and summarizing the relevant distributed multi-generation structures.

  • PDF

직교류 열교환기의 모듈수에 따른 열전달 및 압력강하 특성 (Heat Transfer and Pressure Drop of Cross-flow Heat Exchanger on Modules Variation)

  • 김종민;김진수;유병훈;금성민;이창언;이승로
    • 에너지공학
    • /
    • 제22권2호
    • /
    • pp.120-127
    • /
    • 2013
  • 본 연구는 예혼합 연소시스템에 적용할 직교류 엇갈림 배열 열교환기의 열전달 및 압력강하 특성 검토를 목적으로 한다. 따라서 비예혼합화염보다 화염길이가 짧고 당량비 조절을 통해 NOx 및 CO 배출을 제어할 수 있는 예혼합방식의 버너 앞에 모듈로 구성된 열교환기를 설치한 후 당량비를 변화시킬 때 NOx와 CO의 배출특성을 검토하였다. 또한 열교환기의 모듈 변화에 대한 유용도, 엔트로피 생성량 및 압력강하를 계산하였고 엑서지 로스를 검토하여 열교환기의 성능을 분석하였다.

유동형 미세 열유속 센서의 설계 (Design of The Micro Fluidic Heat Flux Sensor)

  • 김정균;조성천;이선규
    • 한국정밀공학회지
    • /
    • 제26권11호
    • /
    • pp.138-145
    • /
    • 2009
  • A suspended membrane micro fluidic heat flux sensor that is able to measure the heat flow rate was designed and fabricated by a complementary-metal-oxide-semiconductor-compatible process. The combination of a thirty-junction gold and nickel thermoelectric sensor with an ultralow noise preamplifier, low pass filter, and lock-in amp has enabled the resolution of 50 nW power and provides the sensitivity of $11.4\;mV/{\mu}W$. The heater modulation method was used to eliminate low frequency noises from sensor output. It is measured with various heat flux fluid of DI-water to test as micro fluidic application. In order to estimate the heat generation of samples from the output measurement of a micro fluidic heat-flux sensor, a methodology for modeling and simulating electro-thermal behavior in the micro fluidic heat-flux sensor with integrated electronic circuit is presented and validated. The electro-thermal model was constructed by using system dynamics, particularly the bond graph. The electro-thermal system model in which the thermal and the electrical domain are coupled expresses the heat generation of samples converts thermal input to electrical output. The proposed electro-thermal system model shows good agreement with measured output voltage response in transient state and steady-state.

지열발전을 위한 HFC 유기랭킨 사이클의 시뮬레이션 (Simulation of HFC organic Rankine cycles for geothermal power generation)

  • 백영진;김민성;장기창;윤형기;이영수;나호상
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2009년도 춘계학술대회 논문집
    • /
    • pp.569-572
    • /
    • 2009
  • In this study, HFC ORCs (Organic Rankine Cycles) are investigated for a low-temperature geothermal power generation by a simulation method. A steady-state simulation model is developed to analyze and optimize cycle's performance. The model contains a turbine, a pump, an expansion valve and heat exchangers. The turbine and pump are modelled by an isentropic efficiency. Simulations were carried out for the given heat source and sink inlet temperatures, and given flow rate that is based on the typical power plant thermal-capacitance-rate ratio. 3 HFC fluids are considered as a candidate for a working fluid of low-temperature ORCs. In this study, all optimized HFC ORCs are shown to yield almost the same performance in terms of power for a low-temperature heat source of about $100^{\circ}C$.

  • PDF

열전발전량에 영향을 미치는 요인과 최적의 열전발전시스템에 관한연구 (A Study for Thermoelectric Generator System And Caused Low Thermoelectric Power)

  • 문채주;정의헌;임정민;박상진;김태곤;김용구
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2008년도 춘계학술발표대회 논문집
    • /
    • pp.68-74
    • /
    • 2008
  • This paper describes the causes and effects that have influence on thermoelectric generation. If heat transfer is unequal to thermoelectric modules, we could not get the maximum thermoelectric power. So, by experiment, we analysed the differences of power generation according to the state of the contact between thermoelectric module and heat source. And with the variation of heat transfer area, the generated power was analysed also. Using the experimental results we proposed a thermoelectric generation system.

  • PDF

마이크로 가스터빈 열병합 발전시스템 성능평가 (Performance Test of MGT Combined Heat & Power System)

  • 허광범;박정극;임상규
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2006년 제4회 한국유체공학학술대회 논문집
    • /
    • pp.313-316
    • /
    • 2006
  • As Decentralized Generation(DG) becomes more reliable and economically feasible, it is expected that a higher application of DG units would be interconnected to the existing grids. This new market penetration of DG technologies is linked to a large number of factors like technologies costs and performances, interconnection issues, safety, market regulations, environmental issues or grid connection constrains. Korea Electric Power Corporation (KEPCO) has researched performance characteristics of the 60k W class 1) basic start-up & shutdown operation analysis 2) interconnection test 3) MGT -absorption chiller-heater system in the local condition. Variations of heat recovery from exhaust gas has measured according to micro gas turbine output of 15, 30, 45, 60kW. From those results, the performance of the MGT-absorption chiller/heater system has been evaluated. The suggested strategy and experience for the evaluation of the distributed generation will be used for the introduction of other distributed generation technologies into the grid in the future.

  • PDF

초고속 스핀들의 윤활조건 선정을 위한 기초 연구 (A Foundation Study on the Selection of Bearing Lubrication Conditions in High-speed Spindle)

  • 안성환;이춘만
    • 한국기계가공학회지
    • /
    • 제8권1호
    • /
    • pp.3-9
    • /
    • 2009
  • Recently, a high speed cutting is essential requirement to satisfy latest demand of high precision product and machining of hard materials. However heat generation by high speed rotation causes many problems. The machining error and shortening spindle lifetime by thermal stress is typical example. Generation of heat is mostly caused by sliding at the rotor and bearing. For minimization of heat generation at bearing, decision of the condition of proper lubrication is necessary. The thermal study about 40,000rpm spindle by changing the condition of oil-air lubrication method is carried out in this paper. The results of this paper can be used effectively in the decision of oil-air lubrication condition of other types of spindle for machine tools.

  • PDF

Evaporation of Water in an Aqueous Lithium Bromide Solution flowing over a Horizontal Tube

  • Kim, Dong-Kwan;Kim, Moo-Hwan
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제9권3호
    • /
    • pp.57-62
    • /
    • 2001
  • Falling film heat transfer analyses with aqueous lithium bromide solution were performed to investigate the transfer characteristics of the copper tubes. Finned (knurled) tube and a smooth tube were selected as test specimens. Averaged generation fluxes of water and the heat flux were obtained. As the film flow rate of the solution increased, the generation fluxes of water decreased for both tubes due to the fact that the heat transfer resistance increased with the film thickness. The effect of the enlarged surface area at the knurled tube was supposed to be dominant at a small flow rate. The generation fluxes of water increased with the increasing degree of tube wall superheat. Nucleate boiling is supposed to occur at a wall superheat of 20K for a smooth tube, and at 10K for a knurled tube. The increased performance of the knurled tube was supposed to mainly come from the effect of the increased heating surface area.

  • PDF

고속 스핀들용 공기 베어링의 열 특성에 관한 연구 (A Study on Thermal Characteristics of Air Bearing System for High-Speed Spindle)

  • 이득우;이종렬;김보언;안지훈
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2000년도 춘계학술대회 논문집
    • /
    • pp.1021-1026
    • /
    • 2000
  • The thermal characteristics of high-speed air spindle system with built-in motor are studied. Experiment and finite element method analysis obtain temperature rise and temperature distribution of housing. For the analysis three-dimensional model is built and temperature rise and distribution in thermal steady state are computed for each rotational frequency. Generally. It is said that the heat generation of air bearing is negligible. But it is certain that the heat generation of air bearing can not be negligible especially in high-speed conditions Frequency response test for air spindle system is executed. In case that the heat generation of air spindle system is high, natural frequency of the system becomes lower when it reaches thermal steady-state and it means that the stiffness of air hearing becomes smaller due to the change of bearing clearance. It is shown that the temperature rise of all spindle system causes thermal expansion md induces the variation of hearing clearance. In consequence the st illness of air bearing becomes smaller.

  • PDF