• 제목/요약/키워드: Heat Flow

검색결과 5,829건 처리시간 0.039초

데시칸트 제습기용 열교환기 설계에 관한 수치해석적 연구 (A Numerical Study on the Design of Exchanger for Desiccant Dehumidifier)

  • 김치완;안영철;김길태
    • 동력기계공학회지
    • /
    • 제17권6호
    • /
    • pp.54-62
    • /
    • 2013
  • A numerical analysis is performed to evaluate mass flow balance in the heat exchanger for the dehumidifier. To improve the mass flow balance for maximum heat transfer performance, inlet, outlet and baffle are changed. Mass flow balance is evaluated by non-uniformity of flow which is the same concept with the standard deviation. Usually, there will occur many paths between the inlet and the outlet, however, it will follow shortest and low resistance ways. The uniform distribution of flow is numerically analyzed for several types of heat exchangers. Making the shortest way between the inlet and the outlet is most important factor. Two types of heat exchangers are installed in the dehumidifier and 4 cases of Type A heat exchangers and 3 cases of Type B heat exchangers are evaluated and optimized. The result of this research is applied to design heat exchanger for commercial dehumidifiers.

채널내 공기유동이 있는 유하액막의 열전달특성에 관한 실험적 연구 (An Experimental study on heat transfer of a falling liquid film in air channel flow)

  • 오동은;강병하;김석현
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.2291-2296
    • /
    • 2007
  • Thermal transport from vertical heated surface to falling liquid film in a channel has been investigated experimentally. Air-flow is introduced into channel to make a counter flow against falling liquid film. This problem is of particular interest in the design of direct contact heat exchange system, such as cooling tower, evaporative cooling system, absorption cooling system, and distillation system. The effects of channel width and air flow rate on the heat transfer to falling liquid film are studied in detail. The results obtained indicate that heat transfer rate is gradually decreased with an increase in the channel width without air flow as well as with air flow in a channel. It is also found that heat transfer rate of air-flow is increased while heat transfer rate of falling liquid film is decreased with an increase in the air flow rate at a given channel width. However, total heat transfer rate form the heated surface is increased as the air flow rate is increased.

  • PDF

판형열교환기 핀 홀의 위치 및 유속에 따른 누수율 및 내부 유동 특성에 관한 실험적 연구 (Experimental Study on Leak Flow Rate and Inner Flow Characteristics of Plate Heat Exchangers with Pin-hole Location and Mass Flux)

  • 송강섭;백창현;김성우;김용찬
    • 설비공학논문집
    • /
    • 제28권5호
    • /
    • pp.171-177
    • /
    • 2016
  • Plate heat exchangers have been widely used in various fields because of their high heat transfer coefficients, small area of installation, and ease of maintenance compared to other heat exchangers. However, when plate heat exchanger is used for a long time, leak can occur due to inner crack. Therefore, it is important to understand the inner flow characteristics in plate heat exchangers. In this study, the inner flow characteristics and flow rate of plate heat exchanger were evaluated using various flow directions, pin-hole sizes, and Reynolds numbers. In downflow, initially most water flowed to the opposite of the inlet due to distribution region. Then it gradually had a uniform distribution due to chevron configuration. In upflow, it had a uniform flow consistently due to the dominant gravity effect. As the Reynolds number increased, the leak rate was decreased due to the inertia effect regardless of the flow direction.

유하액막식 암모니아 흡수기에서 증기 유동방향에 따른 열 및 물질전달 특성 (Heat and Mass Transfer Characteristics of a Falling Film Ammonia Absorber with Respect to the Vapor Flow Direction)

  • 권경민;정시영;김병주;정은수
    • 설비공학논문집
    • /
    • 제16권1호
    • /
    • pp.16-25
    • /
    • 2004
  • The flow and heat/mass transfer in the falling-film of a heat exchanger can be influenced by the motion of the surrounding refrigerant vapor. In this study, the effect of the vapor flow direction on the absorption heat transfer has been investigated for a falling-film helical coil which is frequently used as the absorber of ammonia/water absorption refrigerators. The experiments were carried out for different solution concentration. The heat and mass transfer performance was measured for both parallel and counter-current flow. The effect of vapor flow on the heat and mass transfer is found to be increased with decreasing solution concentration. In the experiments with low solution concentration, whose vapor specific volume is great, the counter-current flow of vapor resulted in uneven distribution of falling-film and reduced the heat transfer performance of the absorber. The direction of the vapor flow hardly affected the thermal performance as the solution concentration became stronger since the specific volume of the ammonia/water vapor was much smaller than that of the water vapor.

채널내 공기유동이 있는 유하액막의 열전달특성에 관한 실험적 연구 (An Experimental Study on Heat Transfer of a Falling Liquid Film in Air Channel Flow)

  • 오동은;강병하;김석현;이대영
    • 대한기계학회논문집B
    • /
    • 제32권5호
    • /
    • pp.335-341
    • /
    • 2008
  • Thermal transport from vertical heated surface to falling liquid film in a channel has been investigated experimentally. Air-flow is introduced into channel to make a counter flow against falling liquid film. This problem is of particular interest in the design of direct contact heat exchange system, such as cooling tower, evaporative cooling system, absorption cooling system, and distillation system. The effects of channel width and air flow rate on the heat transfer to falling liquid film are studied in detail. The results obtained indicate that heat transfer rate is gradually decreased with an increase in the channel width without air flow as well as with air flow in a channel. It is also found that heat transfer rate of air-flow is increased while heat transfer rate of falling liquid film is decreased with an increase in the air flow rate at a given channel width. However, total heat transfer rate from the heated surface is increased as the air flow rate is increased.

희박 분무영역에서의 분무냉각 막비등 열전달에 관한 연구 (Study on Film Boiling Heat Transfer of Spray Cooling in Dilute Spray Region)

  • 김영찬
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.1481-1486
    • /
    • 2004
  • This report presents experimental results on the heat transfer coefficients in the boiling region of spray cooling for actual metallurgical process. In this study, the heat flux distribution of a two dimensional dilute spray impinging on hot plate was experimentally investigated. Based on the experimental results, they classified the heat transfer area into the stagnation region and wall-flow region. In the stagnation region, the local heat transfer coefficient relates mainly to the droplet-flow-rate supplied from spray nozzle directly, so the local heat transfer coefficients is good agreement with the predicted values from correlation for spray cooling proposed by former report However, the local heat transfer coefficient in wall-flow region is larger than predicted values, and it is found that the rebounding droplets-flow-rate must be accurately evaluated to predict the local heat transfer coefficient in this region.

  • PDF

판형 열교환기의 맥동유동에 의한 열전달 향상에 관한 수치해석연구 (A NUMERICAL STUDY ON HEAT TRANSFER ENHANCEMENT BY PULSATILE FLOW IN A PLATE HEAT EXCHANGER)

  • 이명성;허남건;강병하
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2006년도 추계 학술대회논문집
    • /
    • pp.93-96
    • /
    • 2006
  • The heat transfer enhancement by pulsatile flow in the plate heat exchanger has been investigated numerically in the present study. The numerical study was performed in the range of the mass flux from 0.04 to 0.12 kg/s. The results showed that the pulsatile flow produces resonating vortex shedding at the groove sharp edges and a strong transient vortex rotation within the grooved channels. As a result, the mixing between the trapped volume in the grooved cavity and the main stream was enhanced. Good agreements between the predictions and measured data are obtained in steady flow. And the heat transfer of pulsatile flow is about 2.4 times than steady flow when frequency is 10 Hz and the mass flux of cold side is 0.04 kg/s.

  • PDF

다공성 모델링을 이용한 평행류 열교환기의 열.유동 해석 (Heat and Flow Analysis of a Parallel Flow Heat Exchanger Using Porous Modeling)

  • 정길완;이관수
    • 대한기계학회논문집B
    • /
    • 제25권12호
    • /
    • pp.1784-1792
    • /
    • 2001
  • Numerical analysis on a parallel flow heat exchanger(PFHE) is performed using 2 dimensional turbulent porous modeling. This modeling can consider three-dimensional configuration of passage (flat tube with micro-channels), and the stability and accuracy of numerical results are improved. The geometrical parameters(e.g., the position of separators, inlet/outlet, and porosity of passages of a PFHE) are varied in order to examine the flow and thermal characteristics and flow distribution of the single phase multiple passages system. The flow non-uniformities along the paths of the PFHE are observed to evaluate the thermal performance of the heat exchanger. The location of inlet affects the heat transfer, and the location of outlet affects the pressure drop. The porosity with the optimum thermal performance is around 0.53.

단상유동 조건에서 용접형 판형 열교환기의 열전달 및 압력강하 특성연구 (Heat Transfer and Pressure Drop Characteristics of Brazed Plate Heat Exchangers with Single-Phase Flow)

  • 김만배;박창용
    • 설비공학논문집
    • /
    • 제26권11호
    • /
    • pp.522-528
    • /
    • 2014
  • This experimental study measured and analyzed the heat transfer and pressure drop performance of brazed plate heat exchangers. Heat exchangers with different plate numbers of 10, 20, 30, and 40 were used for measurement, and their plate pattern was identical. The experiment was performed with distilled water, by changing the hot-side flow rate, with the cold-side flow rate fixed. The experimental results were compared with the calculated values by correlations based on gasketed plate heat exchangers, and showed that the heat transfer performance and pressure drop of brazed plated heat exchangers were higher than those of gasketed plate heat exchangers. From the variation of the friction factor, it could be inferred that in the flow channels of brazed plate heat exchangers, turbulent flow occurred at Reynolds numbers higher than 500. A new correlation to predict the Nusselt number was developed, and its absolute average deviation was 2.62%, compared with the values from the experimental data.

Plate and Shell 열교환기의 단상유동 열전달 및 압력강하 특성에 관한 실험적 연구 (Experimental Study on Heat Transfer and Pressure Drop Characteristics for Single-Phase Flow in Plate and Shell Heat Exchangers.)

  • 서무교;김영수
    • 설비공학논문집
    • /
    • 제12권4호
    • /
    • pp.422-429
    • /
    • 2000
  • Plate and shell heat exchanger(P&SHE) is widely applied as evaporators or condensers in the refrigeration and air conditioning systems for their high efficiency and compactness. In order to set up the database for the design of the P&SHE, heat transfer and pressure drop characteristics for single phase flow of water in a plate & shell heat exchanger are experimentally investigated in this study. Single phase heat transfer coefficients were measured for turbulent water flow in a plate and shell heat exchangers by Wilson plot method. The shell side heat transfer resistance was varied and the overall heat transfer coefficients were measured. The single-phase heat transfer coefficients in a plate side were obtained by Wilson plot method. Single-phase heat transfer correlations based on projected heat transfer area and friction factor correlations have been proposed for single phase flow in a plate and shell heat exchanger.

  • PDF