• 제목/요약/키워드: Heat Balance Equation

검색결과 102건 처리시간 0.027초

소형 4행정사이클 무과급 디이젤 기관의 성능 시뮤레이션 전산프로그램의 개발에 관한 연구 (A study on the development of simulation program for the small naturally aspirated four-stroke diesel engine)

  • 백태주;전효중
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제8권1호
    • /
    • pp.17-36
    • /
    • 1984
  • Since 1973, the competition on the development of fuel saving type internal combustion engines has become severe by the two times oil shock, and new type engines are reported every several months. Whenever these new type engines are developed, new designs are required and they will be offered in the market after performing the endurance test for a long time. But the engine market is faced with a heavy burden of finance, as the developing of a new engine requires tremendous expenses. For this reason, the computer simulation method has been lately developed to cope with it. The computer simulation method can be available to perform the reasonable research works by the theoretical analysis before carrying out practical experiments. With these processes, the developing expenses are cut down and the period of development is curtailed. The object of this study is the development of simulation computer program for the small naturally aspirated four-stroke diesel engine which is intended to product by the original design of our country. The process of simulation is firstly investigated for the ideal engine cycle, and secondly for the real engine cycle. In the ideal engine cycle, each step of the cycle is simulated by the energy balance according to the first law of thermodynamics, and then the engine performance is calculated. In the real cycle imulation program, the injection rate, the preparation rate and the combustion rate of fuel and the heat transfer through the wall of combustion chamber are considered. In this case, the injection rate is supposed as constant through the crank angle interval of injection and the combustion rate is calculated by the Whitehouse-Way equation and the heat transfer is calculated by the Annand's equation. The simulated values are compared with measured values of the YANMAR NS90(C) engine and Mitsubishi 4D30 engine, and the following conclusions are drawn. 1. The heat loss by the exhaust gas is well agree with each other in the lower load, but the measured value is greater than the calculated value in the higher load. The maximum error rate is about 15% in the full load. 2. The calculated quantity of heat transfer to the cooling water is greater than the measured value. The maximum error rate is about 11.8%. 3. The mean effective pressure, the fuel consumption, the power and the torque are well agree with each other. The maximum error is occurred in the fuel consumption, and its error rate is about 7%. From the above remarks, it may be concluded that the prediction of the engine performance is possibly by using the developed program, although the program needs to reform by adding the simulation of intake and exhaust process and assumping more reliable mechanical efficiency, volumetric efficiency, preparation rate and combustion rate.

  • PDF

다중관형 CO2 급탕열교환기의 열적성능에 대한 해석연구 (An analytical study on the thermal performance of multi-tube CO2 water heater)

  • 장근선;최연성;김영재
    • 한국산학기술학회논문지
    • /
    • 제17권8호
    • /
    • pp.23-30
    • /
    • 2016
  • 본 연구에서는 길이 4.5 m와 7.5 m의 다중관 $CO_2$ 급탕 열교환기의 열전달 및 압력강하 특성을 ${\epsilon}-NTU$ 방법을 사용하여 해석하고 결과를 기존의 실험 데이터와 비교하였다. 급탕 열교환기는 쉘측에 물이 흐르고 8개로 구성된 내부 튜브에 $CO_2$를 흐르게 하였으며 열전달 효율을 최대화하기 위하여 대향류로 설계하였다. 각 노드에 대한 물과 $CO_2$ 냉매의 유동에 대한 에너지 평형 방정식은 단면분할법을 이용하여 해석하였다. 열전달율 계산값은 실험값과 ${\pm}5%$ 범위 내에서 잘 일치하였다. 반면에 물의 출구온도는 물 유량이 증가함에 따라 거의 선형적으로 감소하며 계산값과 실험값은 ${\pm}3%$ 내에서 일치하였다. 결과에서 열전달율은 4.5 m와 7.5 m 급탕 열교환기 모두 물 유량 또는 $CO_2$ 입구온도가 증가함에 따라 거의 선형적으로 증가하였으며, 반면에 물 유량이 증가함에 따라 물의 출구온도는 선형적으로 감소하였다. $CO_2$ 압력강하 계산값과 실험값은 $CO_2$가 고유량일 때 5 % 내에서 잘 일치한 반면에 $CO_2$가 저유량일 때 실험값이 약 20 % 높게 나타났다.

해양온도차 발전을 위한 심층수 파이프 직경에 따른 에너지 손실량 검토 (Feasibility Study on Cold Water Pipe Diameter by Friction Loss and Energy Conversion on OTEC)

  • 정훈;허균영
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 추계학술대회 초록집
    • /
    • pp.170-170
    • /
    • 2010
  • The energy conversion from the temperature difference between hot and cold source like ocean thermal energy conversion (OTEC), requires a long and large-diameter pipe (about 1000 to 10,000 meters long) to reach the deep water. The pipe diameter ranges from 2.8 meter for proposed early test systems, to 5 meter for large, commercial power generation systems. The pipe must be designed to resist collapsing pressures produced by water temperature and density differences, and the reduced pressure required to induce flow up the pipe. Other design considerations include the external-drag effect on the pipe due to ocean currents, and the wave-induced motions of the platform to which the pipe is attached. Various approaches to the pipe construction have been proposed, including aluminum, steel, concrete, and fiberglass. More recently, a flexible pipe construction involving the use of fiberglass reinforced plastic has been proposed. This report presents the results of a scaled fixed cold water pipe (CWP) model test program performed by EES(Engineering Equation Solver) to demonstrate the feasibility of this pipe approach.

  • PDF

반사판을 이용한 고정식 집속형 복합 Panel에 대한 연구 (A Study on the Fixed-Concentrating Hybrid Panel using Reflector)

  • 김규조;김완태;이태호;유형철;허창수
    • 한국태양에너지학회 논문집
    • /
    • 제21권2호
    • /
    • pp.1-8
    • /
    • 2001
  • The most effective methods for utilizing solar energy are to use the sunlight and solar thermal energy such as hybrid panel simultaneously and to use concentrator. From such a view point systems using various kinds of photovoltaic panels are constructed in the world. However, there has not been a hybrid panel with a concentrator. If the sunlight is concentrated on solar cell, cell conversion efficiency increases and the temperature of the solar cell s increases. As the temperature of the solar cells increases, the cell conversion efficiency gradually decreases. For maintaining the cell conversion efficiency constant, it is necessary to keep solar cell at low temperature. In this paper, after designing a concentration rate for concentrating, we propose a model for cooling the cell and for using wasted heat. And, we compare it with conventional panels after calculating the electrical and thermal efficiency, using the energy balance equation.

  • PDF

The formation mechanism of grown-in defects in CZ silicon crystals based on thermal gradients measured by thermocouples near growth interfaces

  • Abe, Takao
    • 한국결정성장학회지
    • /
    • 제9권4호
    • /
    • pp.402-416
    • /
    • 1999
  • The thermal distributions near the growth interface of 150nm CZ crystals were measured by three thermocouples installed at the center, middle (half radius) and edge (10nm from surface) of the crystals. The results show that larger growth rates produced smaller thermal gradients. This contradicts the widely used heat flux balance equation. Using this fact, it is confirmed in CZ crystals that the type of point defects created is determined by the value of the thermal gradient(G) near the interface during growth, as already reported for FZ crystals. Although depending on the growth systems the effective length of the thermal gradient for defect generation are varied, we defined the effective length as 10n,\m from th interface in this experiment. If the G is roughly smaller than 20C/cm, vacancy rich CZ crystals are produced. If G is larger than 25C/cm, the species of point defects changes dramatically from vacancies to interstitials. The experimental results after detaching FZ and CZ crystals from the melt show that growth interfaces are filled with vacancies. We propose that large G produces shrunk lattice spacing and in order to relax such lattice excess interstitials are necessary. Such interstitials recombine with vacancies which were generated at the growth interface, nest occupy interstitial sites and residuals aggregate themselves to make stacking faults and dislocation loops during cooling. The shape of the growth interface is also determined by te distributions of G across the interface. That is, the small G and the large G in the center induce concave and convex interfaces to the melts, respectively.

  • PDF

반사판을 이용한 고정식 집속형 복합 Panel에 대한 연구 (A study on the fixed-concentrating hybrid panel using reflector)

  • 김규조;김승환;유형철;김완태;허창수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.463-466
    • /
    • 2001
  • The most effective methods of utilizing solar energy are to use the sunlight and solar thermal energy such as hybrid panel simultaneously and to use concentrator. From such a view point, systems using various kinds of photovoltaic panels were constructed in the world. However there have not been a type of panel using concentrator and hybrid simultaneously. If the sunlight are concentrated on the solar cell, cell conversion efficiency increase and the temperature of the solar cells increases. As the temperature of the solar cells increases, so cell conversion efficiency decreases. Therefore, for maintaining cell conversion efficiency at these conditions, it is necessary to keep the cell at low temperature. In this paper, after designing a concentrate rate for concentrating, we proposed model for cooling cell and using waste heat, and we compared with conventional panels after calculating the electrical and thermal efficiency using energy balance equation.

  • PDF

가변 풍량 유닛에 의한 실내 공간의 온도제어를 위한 공간의 분할 모델과 상태궤환 제어기의 개발에 관한 연구

  • 박세화;신승철
    • 설비공학논문집
    • /
    • 제13권10호
    • /
    • pp.947-959
    • /
    • 2001
  • We propose a control scheme to control the indoor zone temperature via variable air volume (VAV) unit. To control the room temperature, state space model of the conditioned zone which is partitioned into nine artificial sectional regions is derived. The nonlinearity of the damper motion and actuator are considered for the practical use in the state space system description. The temperature control of the room temperature is performed by manipulating the degree of openness of the damper in relation to the local room temperature and the supplied air flow rate. In general, since a local temperature in the conditioned zone is measured, it is required to estimate the temperature values in each regions for the precise temperature control. We thus design a state observer to estimate the regional temperature, and use these values in the controller. The overall control system consists of the state observer based state feedback with the integral control. We compared the control results of the proposed scheme with those of cascade proportional and integral (PI) control, and showed that the scheme achieved precise control of the conditioned system.

  • PDF

GTL 공정에서 아민 수용액을 이용한 이산화탄소 제거공정의 전산모사에 대한 연구 (A Simulation Study on the Carbon Dioxide Removal Process Using Aqueous Amine Solution in the GTL Process)

  • 조정호;이지환
    • 한국산학기술학회논문지
    • /
    • 제12권7호
    • /
    • pp.3334-3340
    • /
    • 2011
  • 본 연구에서는 GTL (Gas To Liquids) 파일럿 공정의 설계를 위한 아민 수용액을 이용한 이산화탄소 제거공정에 대한 전산모사를 수행하였다. 이산화탄소 제거를 위한 용매로써 30wt% DEA(diethanol amine) 수용액을 사용하였으며, 공정 배열은 흡수탑과 탈거탑의 2기의 column을 사용하였다. 전산모사를 위해서 Invensys사의 PRO/II with PROVISION 9.0을 사용하였으며 열역학 모델식으로는 amine special package내의 Kent-Eisneberg 모델식을 사용하였다. 전산모사를 통해서 이산화탄소 제거공정에 대한 열 및 물질수지를 도출하였으며, 흡수탑과 탈거탑에 대한 충진탑의 직경과 높이를 산출하였다.

Experimental and numerical assessment of helium bubble lift during natural circulation for passive molten salt fast reactor

  • Won Jun Choi;Jae Hyung Park;Juhyeong Lee;Jihun Im;Yunsik Cho;Yonghee Kim;Sung Joong Kim
    • Nuclear Engineering and Technology
    • /
    • 제56권3호
    • /
    • pp.1002-1012
    • /
    • 2024
  • To remove insoluble fission products, which could possibly cause reactor instability and significantly reduce heat transfer efficiency from primary system of molten salt reactor, a helium bubbling method is employed into a passive molten salt fast reactor. In this regard, two-phase flow behavior of molten salt and helium bubbles was investigated experimentally because the helium bubbles highly affect the circulation performance of working fluid owing to an additional drag force. As the helium flow rate is controlled, the change of key thermal-hydraulic parameters was analyzed through a two-phase experiment. Simultaneously, to assess the applicability of numerical model for the analysis of two-phase flow behavior, the numerical calculation was performed using the OpenFOAM 9.0 code. The accuracy of the numerical analysis code was evaluated by comparing it with the experimental data. Generally, numerical results showed a good agreement with the experiment. However, at the high helium injection rates, the prediction capability for void fraction of helium bubbles was relatively low. This study suggests that the multiphaseEulerFoam solver in OpenFOAM code is effective for predicting the helium bubbling but there exists a room for further improvement by incorporating the appropriate drag flux model and the population balance equation.

사과의 건조조건(乾燥條件)에 따른 건조특성(乾燥特性) (The Drying Characteristics of Apples at Various Drying Conditions)

  • 정신교;최용희;손태화;최종욱
    • 한국식품과학회지
    • /
    • 제18권1호
    • /
    • pp.61-65
    • /
    • 1986
  • 홍옥(紅玉)을 시료(試料)로 하여 건조조건(乾燥條件)을 다르게하여 건조특성(乾燥特性), 수분이동현상(水分移動現像), 건조중(乾燥中) 시료온도(試料溫度) 및 내부수분(內部水分)의 분포(分布)를 조사하였다. 사과의 수분확산계수(水分擴散係數)는 $1.1470{\sim}2.2148{\times}10^{-5}cm^2/sec$, 확산활성화(擴散活性化)에너지는 6.6 kcal/g mole 이었으며 Fick's law에서 아래의 식을 유도할 수 있었다. $${\In}\;{\Delta}t=In\;{\Delta}to-{\frac{D{\pi}^2{\theta}}{4d^2}}$$ 건조중(乾燥中) 내부수분분포(內部水分分布)의 이론치(理論値)와 실측치(實測値)는 거의 일치하였다.

  • PDF