• 제목/요약/키워드: Heat Balance

검색결과 657건 처리시간 0.027초

대규모 주택단지내의 인공구조물에 의한 승온화효과에 관한 연구 (On the Warming Effects due to Artificial Constructions in a Large Housing Complex)

  • 김해동;이송옥;구현숙
    • 한국환경과학회지
    • /
    • 제12권7호
    • /
    • pp.705-713
    • /
    • 2003
  • In mid-August 2002, under clear summer pressure patterns, we carried out an intensive meteorological observation to examine the warming effects due to artificial constructions in a large housing complex. We set an automatic weather system(AWS) at two places in a bare soil surface within a limited development district and an asphalt surface within a large apartment residence area, respectively. As a result of observation, it became clear that the difference of the surface air(ground) temperature between the bare soil surface and its peripheral asphalt area reached about 4$^{\circ}C$(13$^{\circ}C$) at the maximum from diurnal variation of surface temperatures on AWS data. Through the heat balance analysis using measurement data, it became clear that the thermal conditions at two places are dependent on the properties of surface material. The latent heat flux over the bare soil surface reached to about 300 W/㎡, which is more than a half of net radiation during the daytime. On the other hand, it was nearly zero over the asphalt surface. Hence, the sensible heat flux over the asphalt surface was far more than that of the bare soil surface. The sensible heat flux over the asphalt surface showed about 20∼30 W/㎡ during the night. It was released from asphalt surface which have far more heat capacity than that of bare soil surface.

가공송전선로용 나전선의 허용전류 산정에 대한 검토 (Calculation of Ampacity for Bare Overhead Conductors)

  • 손홍관;이형권;이은웅
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 추계학술대회 논문집 학회본부 B
    • /
    • pp.303-305
    • /
    • 2000
  • Many standards have published for calculating the ampacity of bare overhead conductors. Although these standards use the same basic heat balance concept, they use different approaches to calculate ampacity ratings. This paper looks at the different approaches used to calculate individual heat balance terms, at the overall impact of these terms on the ampacity rating. And this paper is proposed to the selection of proper standard and atmospheric conditions for calculating the ampacity of bare overhead conductors.

  • PDF

네오디뮴 금속의 전해 채취 중의 열수지 (Heat Balance during the Electrowinning of Neodymium Metal in Molten Salt)

  • 조성욱;유정현;최호길
    • 자원리싸이클링
    • /
    • 제31권3호
    • /
    • pp.81-87
    • /
    • 2022
  • 용융염 전해 채취 공정에서 가장 중요한 경제 지표 중 하나는 에너지 원단위(kwh/kg of metal)이다. 이는 외부로 손실되는 에너지와 전류 효율에 관련된다. 전류 효율은 전해온도에 의해 크게 좌우된다. 한편 염욕의 온도는 전해 초기에 염욕의 열수지 차이로 인해 급격히 상승하여 처음에 목표했던 전해온도와 상이해질 수 있다. 염욕의 의도치 않은 온도 변화는 전류 효율에 악 영향을 미친다. 따라서 전해 초기를 대상으로 열수지 검토를 통해 염욕의 온도 변화에 대한 계산치와 실측치를 비교해 보고 외부로 손실되는 에너지를 평가하는 것은 에너지 원단위를 줄이는 데 도움이 될 것이다. 본 논문에서는 저자들의 실험 데이터를 이용하여 용융염 전해 채취 중의 열수지에 대해 검토하였으며 이를 통해 외부로의 열 손실과 염욕의 온도 상승을 정량적으로 평가할 수 있었다. 이와 같은 방법을 통하면 열 손실을 줄일 수 있는 방안을 도출하고 전해온도를 제어하여 전류 효율을 제고시킴으로써 에너지 원단위를 줄일 수 있다.

낙동강 구미 보의 수면 열수지 계절 변화 (Seasonal Variation of the Surface Heat Budget in the Gumi Reservoir of Nakdong River)

  • 김학윤;서광수;조창범;김해동
    • 한국환경과학회지
    • /
    • 제25권8호
    • /
    • pp.1057-1063
    • /
    • 2016
  • The heat budget is investigated in the Gumi Reservoir of the Nakdong river. In warm climate season, solar radiation effects play a important role in the change of water temperature. The features of the surface heat balance are almost derived by the latent heat flux and the solar radiation flux. On the other hand, in cold climate season, change of heat stored in the water is mainly dominated by latent and sensible heat transfer between water and air, since flux of solar radiation and loss of outgoing long wave radiation balance approximately. For the annual averages, net flux of radiation, evaporation(latent heat) loss are dominant in the Gumi reservoir. The evaporation losses are dominant from spring to early winter. This means that the Gumi reservoir rolls like a lake of thermal medium or deep depth.

여수화력 순환유동상 보일러의 설계특성 고찰 (A Study on Design Characteristics of Yeosu Circulating Fluidized Bed Boiler)

  • 김재성;이종민;김동원;김태현;최상민
    • 한국연소학회지
    • /
    • 제16권1호
    • /
    • pp.1-7
    • /
    • 2011
  • 340 MWe circulating fluidized bed (CFB) boiler in Yeosu power station is under construction. The circulating fluidized bed boiler in the Yeosu power plant has a number of differences from other domestic boilers in terms of scale and design. Evaluation of design parameters of the Yeosu CFB boiler should be required because the direct application of existing technology is limited. In this study, design characteristics of the Yeosu CFB boiler was summarized. And thermogravimetric analysis was conducted with comparing other rank coals. Watersteam side heat absorption, flue gas temperature and heat transfer coefficient were calculated by heat and mass balance. Design parameters for the Yeosu CFB boiler were discussed along with typical value in the CFB design range.

우유의 열처리 정도가 흰쥐가 성장, 단백질 및 칼슘 대사에 미치는 영향 (Effects of Milks by various Heat Treatment on Growth and Protein and Calcium Metabolism of Rats)

  • 이정아
    • Journal of Nutrition and Health
    • /
    • 제28권2호
    • /
    • pp.144-151
    • /
    • 1995
  • This study investigates the supplementing effects of milks by various heat treatment on growth performance and protein and calcium metabolism of rats. For 4 weeks, raw, LTLT-HTST-and UHT-processed milks were given to rats which fed on a calcium free, semi-synthetic diet containing 5%casein. There were no significant differences among the experimental groups in weight gain, feed efficiency ratio and the serum level of total protein and calcium. Also, no significant differences were showed in protein efficiency, nitrogen balance, apparent protein digestibiltiy and the contents of weight and calcium of the left femur as well as 2 incisors. However, the biological value of protein in the UHT-milk group was significantly higher than that of the raw-milk group. The apparent calcium digestibility and calcium balance in the UHT-milk group were higher than those in the raw-, LTLT- and HTST-milk groups. The weight of left femur in all the groups supplemented with various heat-treated milks was significantly impair the nutritive value of protein and calcium in milk. Futhermore, UHT-processing may improve the bioavailability of protein and calcium in milk.

  • PDF

터보과급 가솔린의 열전달에 관한 실험적 연구 (An experimental study on the heat transfer of the turbocharged gasoline engine)

  • 최영돈;홍진관
    • 대한기계학회논문집
    • /
    • 제14권3호
    • /
    • pp.664-675
    • /
    • 1990
  • 본 연구에서는 기관의 내벽면 열전달계수 측정에 직접 사용되는 열전달량을 측정하기 위해서 풍동실험, 냉각수 전열량 및 비등율 측정실험, 오일팬으로의 전열량 측정심험등의 열전달량 측정실험과 과급기에서 압축기와 터빈의 입출구 엔탈피 변화를 측정하고 이를 종합하여 기관에 소요된 단위 연료 발열량에 대한 에너지 소비내역과 과급기의 시스템 효율등을 산정하고 이들을 기관 운전조건의 변화에 따라 고찰하였다.

Characteristics of Reduced Metal from Spent Oxide Fuel by Lithium

  • Kim Ik-Soo;Seo Chung-Seok;Shin Hee-Sung;Hwang Yong-Soo;Park Seong-Won
    • Nuclear Engineering and Technology
    • /
    • 제35권4호
    • /
    • pp.309-317
    • /
    • 2003
  • The mass balance of the unit processes of the Advanced spent fuel Conditioning Process was calculated to obtain basic information. Based on this mass balance, the changes in decay heat and radioactivity of the spent fuel due to the metallization in the high temperature molten salt system were estimated. The decay heat and the radioactivity were calculated by using the ORIGEN2 computer code, and the result showed that the decay heat and the radioactivity of the metallized spent fuel ingot were $24.27\%\;and\;24.24\%$, respectively, compared to those of oxide spent fuel.

열평형적분법에 의한 사다리꼴단면의 직선휜에서의 열전달해석 (Heat Transfer Analysis in a Straight Fin of Trapezoidal Profile by the Heat Balance Integral Method)

  • 조종철;조진호
    • 대한설비공학회지:설비저널
    • /
    • 제11권3호
    • /
    • pp.1-8
    • /
    • 1982
  • When exact analytical solutions to certain type of heat conduction problems are quite cumbersome or not obtainable, it is important to introduce approximate analytical methods which are simple and useful compared with numerical methods. In this study, therefore, the Heat Balance Integral Method is applied to analysis of steady-state conduction in a straight fin of trapezoidal profile, and the two-dimensional temperature distribution in the fin and the approximate fin efficiency are obtained. Results are compared with those by the one- dimensional analysis and two-dimensional numerical analysis for a wide range of Biot numbers. It is shown that the two-dimensional temperature distribution obtained by the integral method is in good agreement with that by the finite element method at Biot numbers for which the result by the one-dimensional analysis is unreliable.

  • PDF

ANALYSIS OF THE OCEAN' AND ATMOSPHERE ROLES IN THEIR HEAT INTERACTION WITH USE OF SATELLITE AND VESSEL

  • Grankov, Alexander Georgievich;Mil'shin, Alexander Alexeevich;Krapivin, Vladimir Fedorovich;Golovachev, Sergey Petrovich
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2006년도 Proceedings of ISRS 2006 PORSEC Volume II
    • /
    • pp.1001-1002
    • /
    • 2006
  • Special problem emphasized by specialists in the field of analyzing the heat interchanges in the system ocean-atmosphere (SOA) is a necessity of determination of the near-surface atmospheric temperature, which can be only indirectly connected with characteristics of the SOA natural microwave radiation measured from satellites. That is why, the following dilemma is not obvious, but interesting and promised: what is better - to use the satellite methods for retrieving the partial parameters of the SOA or for analysis its state as a whole. To our opinion, this task is similar to the idea recognized by specialists engaged in the heat infrared region (8-12 mcm) of electromagnetic spectrum and its applications, where an intensity of natural infrared radiation (effective radiation) is used as the inherent property (the attribute) of the SOA heat balance. Here we studied important aspects of this problem: a) what medium initiates a heat transfer in the SOA and disturbs its heat balance - the ocean or the atmosphere b) what SOA parameters directly influence on its natural microwave radiation intensity (brightness temperature) measured from satellites? We relate these processes mainly to the synoptic range of time scales enriched by various events in the SOA interface such as the mid-latitude and tropical cyclones.

  • PDF