• Title/Summary/Keyword: HeartBeat

Search Result 173, Processing Time 0.031 seconds

Usefulness of Pulsatile Flow Aortic Aneurysm Phantoms for Stent-graft Placement (스텐트그라프트 장치술을 위한 대동맥류 혈류 팬텀의 유용성)

  • Kim, Tae-Hyung;Ko, Gi-Young;Song, Ho-Young;Park, In-Kook;Shin, Ji-Hoon;Lim, Jin-Oh;Kim, Jin-Hyoung;Choi, Eu-Gene K.
    • Journal of radiological science and technology
    • /
    • v.30 no.3
    • /
    • pp.205-212
    • /
    • 2007
  • To evaluate the feasibility and efficacy of a pulsatile aortic aneurysm phantoms for in-vitro study. The phantoms consisted of a pulsating motor part(heart part) and an aortic aneurysm part, which mimicked true physiologic conditions. The heart part was created from a high-pressured water pump and a pulsatile flow solenoid valve for the simulation of aortic flow. The aortic aneurysm part was manufactured from paper clay, which was placed inside a acrylic plastic square box, where liquid silicone was poured. After the silicone was formed, the clay was removed, and a silicone tube was used to connect the heart and aneurysm part. We measured the change in pressure as related to the opening time(pulse rate, Kruskal-Wallis method) and pressure before and after the stent-graft implantation(n = 5, Wilcoxon's signed ranks test). The changes in blood pressures according to pulse rate were all statistically significant(p<0.05). The systolic/diastolic pressures at the proximal aorta, the aortic aneurysm, and the distal aorta of the model were $157.80{\pm}1.92/130.20{\pm}1.92$, $159.40{\pm}1.14/134.00{\pm}2.92$, and $147.20{\pm}1.480/129.60{\pm}2.70\;mmHg$, respectively, when the pulse rate was 0.5 beat/second. The pressures changed to $161.40{\pm}1.34/90.20{\pm}1.64$, $175.00{\pm}1.58/93.00{\pm}1.58$, and $176.80{\pm}1.48/90.80{\pm}1.92\;mmHg$, respectively, when the pulse rate was 1.0 beat/second, and $159.40{\pm}1.82/127.20{\pm}1.48$, $166.60{\pm}1.67/138.00{\pm}1.87$, and $161.00{\pm}1.22/135.40{\pm}1.67\;mmHg$, respectively, when it was 1.5 beat/second. When pulse rate was set at 1.0 beat/second, the pressures were $143.60{\pm}1.67/90.20{\pm}1.64$, $147.20{\pm}1.92/84.60{\pm}1.82$, and $137.40{\pm}1.52/88.80{\pm}1.64\;mmHg$ after stent-graft implantation. The changes of pressure before and after stent-graft implantation were statistically significant(p<0.05) except the diastolic pressures at the proximal(p =1.00) and distal aorta(p=0.157). The aortic aneurysm phantoms seems to be useful for the evaluation of the efficacy of stent-graft before animal or clinical studies because of its easy reproducibility and ability to display a wide range of pressures.

  • PDF

Modulation of the Time Course of Cardiac Chronotropic Responses during Exposure to Affective Pictures

  • Estate M. Sokhadze;Lee, kyung-Hwa;Lee, Jong-Mee;Oh, Jong-In;Sohn, Jin-Hun
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 2000.04a
    • /
    • pp.290-300
    • /
    • 2000
  • One of the most important topics in attentional and emotional modulation of cardiac responses is time course of cardiac chronotropic response. The reason lies in dual innervation of heart, which leads to occurrence of several phases of cardiac response during exposure to affective stimuli, determined by the balance of sympathetic and parasympathetic influences. Cardiac chronotropic reactivity thus represents quite effective measure capable to trace the moment when attending and orienting processes (i.e., sensory intake of stimulus) prime relevant behavioral response (ile., emotion with approach or avoidance tendencies). The aim of this study was to find the time course of heart rate (HR) responses typical for negative (disgust, surprise, fear, anger) and positive (happiness, pleasant erotic) affective pictures and to identify cardiac response dissociation for emotions with different action tendencies such as "approach" (surprise, anger, happiness) and "avoidance" (fear, sadness, disgust). Forty college students participated in this study where cardiac responses to slides from IAPS intended to evoke basic emotions (surprise, fear, anger, sadness, disgust, happiness, pleasant-erotic). Inter-beat intervals of HR were analyzed on every 10 sec basis during 60 sec long exposure to affective visual stimuli. Obtained results demonstrated that differentiation was observed at the very first 10s of exposure (anger-fear, surprise-sad, surprise-erotic, surprise-happiness paris), reaching the peak of dissociation at 30s (same pairs plus surprise-disgust and surprise-fear) and was still effective for some pairs (surprise-erotic, surprise-sad) even at 50s and 60s. discussed are potential cardiac autonomic mechanisms underlying attention and emotion processes evoked by affective stimulation and theoretical considerations implicated to understand the role of differential cardiac reactivity in the behavioral context (e.g., approach-avoidance tendencies, orienting-defense responses).

  • PDF

EMD based Cardiac Arrhythmia Classification using Multi-class SVM (다중 클래스 SVM을 이용한 EMD 기반의 부정맥 신호 분류)

  • Lee, Geum-Boon;Cho, Beom-Joon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.1
    • /
    • pp.16-22
    • /
    • 2010
  • Electrocardiogram(ECG) analysis and arrhythmia recognition are critical for diagnosis and treatment of ill patients. Cardiac arrhythmia is a condition in which heart beat may be irregular and presents a serious threat to the patient recovering from ventricular tachycardia (VT) and ventricular fibrillation (VF). Other arrhythmias like atrial premature contraction (APC), Premature ventricular contraction (PVC) and superventricular tachycardia (SVT) are important in diagnosing the heart diseases. This paper presented new method to classify various arrhythmias contrary to other techniques which are limited to only two or three arrhythmias. ECG is decomposed into Intrinsic Mode Functions (IMFs) by Empirical Mode Decomposition (EMD). Burg algorithm was performed on IMFs to obtain AR coefficients which can reduce the dimension of feature vector and utilized as Multi-class SVM inputs which is basically extended from binary SVM. We chose optimal parameters for SVM classifier, applied to arrhythmias classification and achieved the accuracies of detecting NSR, APC, PVC, SVT, VT and VP were 96.8% to 99.5%. The results showed that EMD was useful for the preprocessing and feature extraction and multi-class SVM for classification of cardiac arrhythmias, with high usefulness.

Effects of Gamgung-tang Gamibang on 3,5,3-triiodothyronine-induced Hyperthyroidism in rats (감궁탕 가미방이 갑상샘기능장애에 미치는 효과)

  • Choi Ho Seung;Kim Young Mok;Lim Jong Kook;Shon Yun Hee;Nam Kyung Soo;Kim Cheol Ho;Jeon Byung Hun
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.17 no.3
    • /
    • pp.648-655
    • /
    • 2003
  • In this study, the effects of Gamgung-tang gamibang on the hyperthyroidism induced by the intraperitoneal injection of 3,5,3-triiodothyronine was examined by the measurement of physical changes, body weight, the volume of food intake and rectal temperature, and heart weight, heart beat, blood pressure with contrast to propranolol, one of beta-blocking agents. the obtained results were as follows. The Gamgung-tang gamibang extract showed to inhibit the decrease of body weight and rectal temperature, and decrease the food intake, so the inhibitory effects of Gamgung-tang gamibang extract on the experimental hyperthyroidism were exhibited. The Gamgung-tang gamibang extract showed the inhibitory effects on the circulatory functions changed and enhanced by the experimental induced hyperthyroidism, the action of Gamgung-tang gamibang extract was less effective than the propranolol of D-CONT group. The Gamgung-tang gamibang extract showed significant effects to inhibit the concentration of serum thyroid houmone, more effective than the propranolol, beta-blocking agents. The Gamgung-tang gamibang extract showed the effective inhibitory reaction on the biochemical changes in serum, cholesterol, ketone bodies, free fatty acid, glucose in hyperthyroid rats induced by 3,5,3-triiodothyronine.

Myocardial Preserving Effect of Fructose-1, 6-diphosphate in Isolated Rat Heart (적출된 쥐심장을 이용한 Fructose-1, 6 diphosphate의 심근보호 효과에 관한 실험)

  • 이철주;조수신;류재온;김문환;김세환;이익호;박소라;서창국
    • Journal of Chest Surgery
    • /
    • v.26 no.2
    • /
    • pp.75-79
    • /
    • 1993
  • Myocardial protection against ischemic and reperfusion injuries is still in troublesome eventhough couples of the way of myocardial protection have been applied since 1970's. One of the possibility in myocardial protection is adding Fructose-l,6-diphosphate(FDP) in cardioplegic solution. It is assumed that FDP can promote ATP production under anaerobic condition as well as inhibiting the supressing effect of lactate on phosphofructokinase. We compared the myocardial protecting effects of FDP in crystalloid cardioplegic solution (St. Thomas formula, 10$^{\circ}C$, pH = 7.4) and reperfusate using isolated rat hearts in modified Langendorf apparatus by the parameters of preischemic and post reperfusing heart rate, time to first beat, occurance of arrhythmia, time to stabilization, and the rate of left ventricular pressure developing. Group A (n = 10), containing no FDP in cardioplegic and reperfusing solutions was control. Group B (n = 5), containing FDP in cardioplegic solution, showed statistically significant superiority of postischemic left ventricular pressure development than the control group. Group C (n = 5), containing FDP in reperfusate, showed statistically significant myocardial depressing effect than the controls. Other parameters were unremarkable. The cause is uncertain, but it is assumed that the negative feedback inhibition of FDP in energy metabolism or unknown blocking effect of FDP on certain transmembrane ionic currents is present. In conclusion, 1) FDP in cardioplegic solution has beneficial effect on postischemic left ventricular preservation. 2) FDP is strong acid when is hydrolyzed, so precise acid titration is neccessary. 3) FDP in reperfusate has negative left ventricular preservation, otherwise the mechanism is still uncertain.

  • PDF

Biometrics System Technology Trends Based on Biosignal (생체신호 기반 바이오인식 시스템 기술 동향)

  • Choi, Gyu-Ho;Moon, Hae-Min;Pan, Sung-Bum
    • Journal of Digital Convergence
    • /
    • v.15 no.1
    • /
    • pp.381-391
    • /
    • 2017
  • Biometric technology is a technology for authenticating a user using the physical or behavioral features of the inherent characteristics of the individual. With the necessity and efficiency of the technology in the fields of finance, security, access control, medical welfare, inspection, and entertainment, the service range has been expanding. Biometrics using biometric information such as fingerprints and faces have been exposed to counterfeit and disguised threats and become a social problem. Recent studies using a bio-signal from the inside of the body other than the bio-information of the external body are being developed. This paper analyzes the recent research and technology of biometric systems using bio-signals, ECG, heart sounds, EEG, and EMG to present the skills needed for the development direction. In the future, utilizing the deep learning to build and analyze database to manage bio-signal based big data for the complex condition of individuals, biometrics technologies suitable for real time environment are expected to be researched.

Review of Analysis of the Effect of Tai Chi Exercise on Blood Pressure and Cardiopulmonary Function (타이치 운동이 혈압과 심폐기능에 미치는 영향에 대한 논문 분석)

  • Eun, Young;Lee, Hea-Young;Choi, Jung-Hyun;Lee, Eun-Ok
    • Journal of muscle and joint health
    • /
    • v.12 no.2
    • /
    • pp.132-142
    • /
    • 2005
  • Purpose: The purpose of this study is to analyze the effect of Tai Chi exercise on Cardiorespiratory function and to identify directions for future research. Method: 19 articles from Medline search of english journals(1981-2004) and 2 from Korean nursing journals were surveyed. The contents analysis were focused on outcome measures and relative factors regarding cardiopulmonary function. Results: There are 21 articles including 8 articles with quasi experimental design, 7 articles with randomized controlled design and 6 articles with comparative non experimental research design. The major subjects of research were older adults, but hypertensive patients, cardiac rehabilitative patient, and osteoarthritic patient also included. The major style of Tai Chi was Yang style with 108-form. The duration of Tai Chi exercise was from 12weeks to 13.2 years in comparative non experimental studies, but 6 weeks to 16weeks in randomized controlled experimental studies. The most effective duration for cardiopulmonary function was over 16weeks. The variables for cardiopulmonary function were blood pressure, heart rate and cardiopulmonary function via $VO_2$ max(ml/kg/min). To reduce the blood pressure in the result was found in 2 articles, to reduce the heart beat was found in 1 article, to improve the cardiopulmonary function via $VO_2$ max in results were found in 7 articles(73%) among 11 articles. Conclusion: The Tai Chi exercise over 16weeks improves the cardiopulmonary function. It is suggested that to verify the effect of Tai Chi on cardiopulmonary function, the difference of gender, age, health status will be identified through repeated experiments.

  • PDF

Effects of Healing Beats program on patients' anxiety, stress, systolic blood pressure, heart rate and Bis Index after epidural blocking : A randomized controlled trial (Healing Beats 프로그램이 경막외강차단 시술 후 환자의 불안, 스트레스, 수축기 혈압, 심박동수 및 Bis Index에 미치는 효과 : 무작위대조군)

  • Bae, Ik Lyul;Song, Ji Ah
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.7
    • /
    • pp.54-65
    • /
    • 2020
  • This randomized pre-post-controlled experimental study determined the effect on patients' anxiety, stress, systolic blood pressure, heart rate and Bis index when the Healing Beats program is applied after epidural blockage. The subjects were selected from the patients who visited the Department of Anesthesiology and Pain for the treatment of epidural blockage and volunteered through the recruitment announcement. A total of 74 sets of data were collected and analyzed with 25 subjects in the experimental group, 24 in the placebo group, and 25 in the control group. The data was analyzed using descriptive statistics, x2-tests, F-tests and repeated measures of ANOVA. As a result of the study, the general characteristics and variables of the experimental group, placebo group, and control group were all the same, and anxiety was measured twice before and after the study. There were significant differences between groups (F=27.175, p<.001), and stress (F=4.78, p<.001), heart rate (F=4.22, p<.001) and the Bis index (F=7.96, p<.001) were analyzed by variance according to population and time. There was a significant difference. However, there was no significant difference in systolic blood pressure (F=1.23, p=.298). In conclusion, the Healing Beats program can be used as an effective and effective intervention for sedation in clinical situations or stressful situations.

A study on the Theory of 'Ja-Yeol(刺熱)' in 32nd Chapter of 'So Moon(素問) Yellow Emperior's Nei-Ching(黃帝內經)' (황제내경(黃帝內經) 소문(素問) 자열론(刺熱論)에 대한 연구(硏究))

  • Kwon, Kun-Hyuck;Hong, Won-Sik
    • Journal of Korean Medical classics
    • /
    • v.3
    • /
    • pp.151-217
    • /
    • 1989
  • In this thesis, I intend to study the translational and clinical interpretation through the theory of Ja-Yeol, and reached the following conclusions. 1. Liver-Heat-Disease due to absess of the function of expelling and lifting off, that Liver-Yang cannot lift up to upper-warmer, and stagnate liver. I think the symptoms of yellowish urine, abdominal pain, somnolence, fever belong to the syndrome of 'Gi-Bun(氣分)', and the symptoms of ravings with surprising, distending pain of hypochondrium, restless involuntary movement of the limbs, unable to lie flat belong to the syndrome of 'Hyeol-Bun(血分)'. 2. Heart-Heat-Disease due that 'Eum-Gi(陰氣)' in heart cannot lay down and reach to stagnate at heart, inner part. I think the symptoms of unjoy, acute cardiac pain, fidgetiness, well-nausea, headeche, reddish face, anhidrosis, etc. reveal with Heart-Heat-Disease. 3. Spleen-Beat-Disease due that 'Eum-Gi' in spleen cannot lay down and Yin of spleen changs heat. I think the symptoms of heaviness of head, cheek pain, fidgetiness, cyanosis, well-nausea, fever, not to let flex and reflex with back pain, diarrhea with abdominal pain, left and right cheek pain reveal with Spleen-Heat-Disease. I think symptoms of fever, diarrhea with abdominal pain belong to the syndrome of Yin-exhausion. 4. Lung-Heat-Disease due to that 'Eum-Gi' in lung cannot lay down. When 'Wi-Gi(衛氣)' stagnates at external part, I think, the symptoms of intolerance to wind and cold, yellowish fur, fever reveal. When Wi-Gi stagnates at lung, inner part, I think, the symptoms of dispnea with cough, pain on chest and back, unable to breath deeply, hydrosis and chilling reveal. 5. Kidney-Heat-Disease, in that the symptoms of back pain, leg aching, extreme thirst and frequently drink, fever, pain and stiffness of nape, cooling and aching leg, heat on plantar pedis, not trying to speak reveal is regarded external heat disease of 'Tai-Yang-Gyeong's(太陽經)' disease that asthenic fever open 'Tai-Yang-Gyeong' and lift by not enough of 'Yang-Gi(陽氣)' lifeing up from Kidney space, the water space of five elements.

  • PDF

Effects of Nanometer Sized Silver Materials on Biological Toxicity During Zebrafish Embryogenesis

  • Yeo, Min-Kyeong;Kang, Mi-Sook
    • Bulletin of the Korean Chemical Society
    • /
    • v.29 no.6
    • /
    • pp.1179-1184
    • /
    • 2008
  • Commercial nanometer sized silver is widely used for its antibacterial effect; however, nanoparticles may also have ecotoxicological effects after being discharged into water. Nanometer sized silver can flow into aquatic environments, where it can exert a variety of physiologically effects in living organisms, including fish. The present study aimed to investigate the effect of nanometer sized silver on the development of zebrafish embryos, analyze the properties of commercial nanometer sized silver and define the toxicity relationship between embryogenesis and hatched flies. The commercial nanometer sized silver was analyzed in the $Ag^+$ ion form. The hatch rate decreased in the nano-silver exposed groups (10 and 20 ppt); furthermore, the hatched flies had an abnormal notochord, weak heart beat, damaged eyes and curved tail. The expression of the Sel N1 gene decreased in the nano-silver exposed groups, and the catalase activities of the exposed groups increased relative to those in the control group. Therefore, the $Ag^+$ ions in commercial nanometer sized silver could accumulate in aquatic environments and seriously damage the development of zebrafish embryos.