• Title/Summary/Keyword: Heart-Assist Devices

Search Result 19, Processing Time 0.026 seconds

Driveline Infections Incidence According to Dressing Methods for Patients with Left Ventricular Assist Device Implantation (좌심실보조장치 수술 환자의 드레싱 방법에 따른 드라이브라인 감염 실태)

  • Choi, Nam Gyung;Choi, Su Jung;Choi, Ji Yeon;Park, Sun Hee
    • Journal of Korean Clinical Nursing Research
    • /
    • v.28 no.2
    • /
    • pp.167-176
    • /
    • 2022
  • Purpose: Driveline infection (DLI) is one of the major adverse events of Left Ventricular Assist Device (LVAD). The purpose of this study was to explore the incidence of DLI according to the driveline dressing methods. Methods: This study was a retrospective cohort study that investigated the medical records of 75 patients who implanted LVAD from January 2015 to December 2020 at a hospital in Seoul, Korea. Traditionally, sandwich dressing method was applied until October 2019, after which newly winded dressing method was adopted for driveline dressing to LVAD patients. The outcome variables were compared between sandwich dressing method applied group (n=41) and winded dressing method applied group (n=34). The follow-up period for DLI was 1 year. Results: When compared participants' characteristics, there was no difference between the two groups, except the type of LVAD device. The incidence of DLI was 17.1% in sandwich dressing group, while no infection was found in winded dressing group (p=.011). Conclusion: Although there were difference in the LVAD devices, it is considered that winded dressing contributed to the reduction of DLI. Further research on standardized dressing methods was required for DLI prevention in Korea.

Modeling of Left Ventricular Assist Device and Suction Detection Using Fuzzy Subtractive Clustering Method (퍼지 subtractive 클러스터링 기법을 이용한 좌심실보조장치 모델링 및 흡입현상 검출)

  • Park, Seung-Kyu;Choi, Seong-Jin
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.22 no.4
    • /
    • pp.500-506
    • /
    • 2012
  • A method to model left ventricular assist device (LVAD) and detect suction occurrence for safe LVAD operation is presented. An axial flow blood pump as a LVAD has been used to assist patient with heart problems. While an axial flow blood pump, a kind of a non-pulsatile pump, has relative advantages of small size and efficiency compared to pulsatile devices, it has a difficulty in determining a safe pump operating condition. It can show different pump operating statuses such as a normal status and a suction status whether suction occurs in left ventricle or not. A fuzzy subtractive clustering method is used to determine a model of the axial flow blood pump with this pump operating characteristic and the developed pump model can provide blood flow estimates before and after suction occurrence in left ventricle. Also, a fuzzy subtractive clustering method is utilized to develop a suction detection model which can identify whether suction occurs in left ventricle or not.

Animal Experiment and Blood Biocompatibility Study of Polymer Valve (고분자판막의 동물실험 및 생체내 혈액적합성 연구)

  • 김상현;홍유선
    • Journal of Chest Surgery
    • /
    • v.30 no.4
    • /
    • pp.357-362
    • /
    • 1997
  • In vivo testings of the monoleaflet polymer valve were performed in seven dogs to prove its blood biocompatibility. The monoleaflet polymer valve used in this study was developed for short-term usage n the ventricular assist device. The frame and leaflet of the polymer valve were made of polyurethane. The inter-aortic valved conduit were implanted in four dogs and the ventriculo-atrial valved conduit was implanted in one dog. The ventricular assist devices with polymer valve were implanted in two dogs. The longest survival was 20 days. Main causes of death were bleeding and infection. To examine the blood compatibility, each blood sample was collected and RBC, WBC, hematocrit, hemoglobin, platelet and lactic acid dehydrogenase were analyzed. These studies thus far demonstrated that, with further development, a reliable and inexpensive polymer valve will be used in the ventricular assist device as short term usage.

  • PDF

Development of Master-Slave Type Tele-Operation Control Robotic System for Arrhythmia Ablation (부정맥 시술을 위한 마스터-슬레이브 원격제어·로봇 시스템 개발)

  • Moon, Youngjin;Park, Sang Hoon;Hu, Zhenkai;Choi, Jaesoon
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.22 no.8
    • /
    • pp.585-589
    • /
    • 2016
  • Recently, the robotic assist system for cardiovascular intervention gets continuously growing interest. The robotic cardiovascular intervention systems are largely two folds, systems for cardiac ablation procedure assist and systems for vascular intervention assist. For the systems, the clinician controls the catheter inserted through blood vessel to the heart via a master console or master manipulator. Most of the current master manipulators have structure of joystick-like pivoting 2 degree of freedom (DOF) handle in the core, which is used in parallel with other sliding switches and input devices. It however is desirable to have customized and optimized design manipulator that can provide clinician with intuitive control of the catheter motion fully utilizing the advantage of the use of robotic structure. A 6 DOF kinematic mechanism that can capture the motion control intention of the clinician in translational 3 DOF and rotational 3 DOF is proposed in this paper. Also, a master-slave motion relationship specially designed for the cardiac catheter manipulation motion is proposed and implemented in an experimental prototype. Design revision for implementation of more efficient motion and experiment in combination with an experimental slave robot system for catheter manipulation are underway.

Outcomes of Extracorporeal Membrane Oxygenation in Children: An 11-Year Single-Center Experience in Korea

  • Kim, Hongsun;Yang, Ji-Hyuk;Cho, Yang Hyun;Jun, Tae-Gook;Sung, Kiick;Han, Woosik
    • Journal of Chest Surgery
    • /
    • v.50 no.5
    • /
    • pp.317-325
    • /
    • 2017
  • Background: Extracorporeal membrane oxygenation (ECMO) has become an important treatment modality in pediatric patients with cardiopulmonary failure, but few studies have been conducted in Korea. Methods: We conducted a retrospective review of pediatric patients younger than 18 years who were placed on ECMO between January 2004 and December 2014 at Samsung Medical Center. Results: We identified 116 children on ECMO support. The overall rate of successful weaning was 51.7%, and the survival to discharge rate was 37.1%. There were 39, 61, and 16 patients on ECMO for respiratory, cardiac, and extracorporeal cardiopulmonary resuscitation, respectively. The weaning rate in each group was 48.7%, 55.7%, and 43.8%, respectively. The survival rate was 43.6%, 36.1%, and 25.0%, respectively. Sixteen patients on ECMO had functional single ventricle physiology; in this group, the weaning rate was 43.8% and the survival rate was 31.3%. Ten patients were on ECMO as a bridge to transplantation (8 for heart and 2 for lung). In patients with heart transplantation, the rate of survival to transplantation was 50.0%, and the overall rate of survival to discharge was 37.5%. Conclusion: An increasing trend in pediatric ECMO utilization was observed. The outcomes were favorable considering the early experiences that were included in this study and the limited supply of specialized equipment for pediatric patients.

DESIGN OF A CENTRIFUGAL BLOOD PUMP FOR ECMO DEVICE THROUGH NUMERICAL ANALYSES (수치해석을 통한 ECMO용 원심형 혈액 펌프 설계)

  • Choi, S.;Hur, N.;Moshfeghi, M.;Kang, S.;Kim, W.;Kang, S.H.
    • Journal of computational fluids engineering
    • /
    • v.21 no.1
    • /
    • pp.103-109
    • /
    • 2016
  • With the rapid increase in the number of patients with cardiopulmonary diseases, more cardiopulmonary circulatory assist devices are also needed. These devices can be employed when heart and/or lung function poorly. Due to the critical role they take, these devices have to be designed optimally from both mechanical and biomechanical aspects. This paper presents the CFD results of a baseline model of a centrifugal blood pump for the ECMO condition. The details of flow characteristics of the baseline model together with the performance curves and the modified index of hemolysis(MIH) are investigated. Then, the geometry of baseline impeller and the volute are modified in order to improve the biomechanical performance and reduce the MIH value. The numerical simulations of two cases represent that when impeller radius and prime volume decrease the MIH value also decreases. In addition, the modified geometry shows more uniform pressure distribution inside the volute. The findings provide valuable information for further modification and improvement of centrifugal blood pumps from both mechanical and biomechanical aspects.

The Feasibility of the DKUH-75 Left Ventricular Assist Device for Acute Cardiogenic Shock in Pigs (돼지의 급성 심인성 쇼크 모델에서 DKUH-75 좌심실보조키의 유용성에 관한 연구)

  • Park, Seong-Sik
    • Journal of Chest Surgery
    • /
    • v.40 no.3 s.272
    • /
    • pp.168-179
    • /
    • 2007
  • Background: The recent trend of an increasing number of patients with acute cardiogenic shock or chronic congestive heart failure following myocardial infarction, as well as the considerable number who can not be weaned from cardiopulmonary bypass after open heart surgery, call for immediate efforts to develop affordable ventricular assist devices that are suitable for the Korean physique. Recently, a pneumatic pulsatile ventricular assist device (VAD), named DKUH-75, has been developed by the Department of Biomedical Engineering, in collaboration with the Department of Thoracic and Cardiovascular Surgery of Dankook University College of Medicine. The feasibility of the DKUH-75 VAD was evaluated on the bases of common hemodynamic variables and echocardiographic measurements in pigs, which are subjected to an acute cardiogenic shock state following myocardial infarction, using a novel coronary artery ligation method employing the ischemic preconditioning concept. Material and Method: Acute cardiogenic shock was induced in 10 Yorkshire Landrace Duroc strain pigs by ligating the left anterior descending coronary artery via an ischemic preconditioning process. The hemodynamic variables were monitored, with epicardial echocardiographic measurements performed before and one hour after the ligation. The DKUH-75 VAD was implanted into 5 pigs one hour after the onset of the shock. The hemodynamic variables and echocardiographic measurements were taken one hour after installation of the VAD. Result: The systolic, diastolic and mean systemic arterial pressures were significantly decreased in all the experimental animals one hour after the ligation. The systolic, diastolic and mean pulmonary arterial pressures were increased (Eds note: this completely contradicts the preceding statement? However, if you mean the non-experimental animals this should be stated?). The left ventricular end diastolic pressure (LVEDP) was increased, but the cardiac index decreased, An increase in the left ventricular end systolic dimension and decreases in the fractional shortening and ejection fraction were observed all animals one hour after the coronary artery ligation. In all 5 of the VAD implanted pigs, the systolic and mean systemic arterial pressures were increased, and the pulmonary arterial pressures decreased one hour after the implantation; the LVEDP decreased, but the cardiac index was significantly increased, In the echocardiographic measurements, the left ventricular end systolic dimension decreased after the implantation of the VAD, but the fractional shortening and ejection fraction significantly increased. Conclusion: Significant improvements in the hemodynamic variables and echocardiographic measurements were observed in the 5 VAD implanted animals one hour after installation, which had been subjected to an acute cardiogenic shock state by ligation of the coronary artery, indicating that the DKUH-75 VAD could help in the recovery of the myocardial function. This suggests that the DKUH-75 VAD is feasible in the short term in relation to an acute cardiogenic shock state due to myocardial infarction.

Short-term Mechanical Circulatory Support with Centrifugal Pump in Cardiac Arrest or Cardiogenic Shock - Report of 5 cases- (심정지 혹은 심인성 쇼크에서 원심성 펌프를 이용한 단기목표의 기계적 순환 보조)

  • 양희철;성기익;뱍계현;전태국;박표원;양지혁;이영탁
    • Journal of Chest Surgery
    • /
    • v.37 no.12
    • /
    • pp.1003-1009
    • /
    • 2004
  • Mechanical circulatory support (MCS) has been used for myocardium failure, but moreover, it may be essential for the life support in cardiac arrest or cardiogenic shock. Many commercial devices can be used effectively for the long-term support. However, there are some limitations in the aspects of the cost and technical support by production company. Short-term support with centrifugal type has been reported numerously with the purpose of bridging to heart transplantation or recovery. We successfully treated 5 patitents who were in the status of cardiogenic shock (n=3) or arrest (n=2) with the technique of extracorporeal life support system (ECLS) or left ventricular assist device (LVAD) using the centrifugal type pump. The MCS were performed emergently (n=2) under cardiac arrest caused by ischemic heart disease, and urgently (n=3) under cardiogenic shock with ischemic heart disease (n=1) or acute fulminant viral myocarditis (n=2). All patients were weaned from MCS. Complications related to the use of MCS were bleeding and acute renal failure, but there were no major complications related to femoral cannulations. Mechanical circulatory support may be essential for the life support and rescue in cardiac arrest or cardiogenic shock.

Animal Experiment of the Pneumatic Ventrivular Assist Device (공압식 심실 보조기의 동물실험)

  • Park, Seong-Sik;Kim, Sam-hyun;Seo, Pil-won;Choi, Chang-hyu;Lee, Sang-hoon;Lee, Hyuk-soo;Hwang, Seung-ok;Ahn, Hyuk
    • Journal of Chest Surgery
    • /
    • v.32 no.12
    • /
    • pp.1065-1077
    • /
    • 1999
  • Background : Ventricular assist devices(VADs) are being used for patients in postcvardiotomy cardiogenic shock status bridge to cardiac transplant settings and in post-myocardial infarction cardiogenic shock. The VAD which was developed at the Deparment of medical engineering in Dankook University College of Medicine was a pneumatically driven device and can maintain pulsatile flow. The goal of this study is to develop animal experimental models using the VAD and to clarify the reliability and hemodynamic property adequacy of end organ perfusion durability and severity of thrombotic-hemolytic tendency of the device. Material and Method : The pneumatic VAD was applied to 8 adult female lambs, We examined some hemodynamic parameters such as arterial blood pressure pulmonary capillary wedge pressure(pcwp) pulmonary artery pressure(PAP) left atrial pressure hour urine output cardiac index VAD flow EKG to determine the reliability of the VAD and hemodynamic compatibility of the experimental animals within 24 hours of experiment. We also observed the end organ perfusion durability of the VAD and thrombotic-hemolytic property of the VAD after 24 hours of VAD insertion. Result: We could monitor all hemodynamic parameters including pcwp PAP cardiac index EKG, adn hour urine as true clinical settings. We observed that the reliability of the VAD was excellent and the hemodynamic property of the experimental animal and end organ perfusion were adequate within 24 hours of experiment. In four lambs surviving 24 hours after insertion the reliability of the VAD and end organ perfusion were excellent and no thrombotic-hemolytic tendency was noted. However after 15 days of experiment the diaphragm of the VAD was torn and it was recommende that the durability of the VAD should be extended. Conclusion : e conclude that the pneumatic VAD developed at Dankook University Biomedical Engineering has good hemodynamic property and low thromboembolic tendency and presents adequate end organ perfusion but we noted that the durability of the device should be expanded further. It will be possible to do more reliable experiment in the future according to the animal experimental method developed in this study especially with the heart failure models.

  • PDF