Analysis of Factors Affecting Nontherapeutic INRs in Korean Outpatients with Mechanical Heart Valves (인공심장판막 치환환자의 치료범위를 벗어난 INR 원인분석)

  • Lee Ju Yeun;Jeong Young Mi;Lee Myung Koo;Kim Ki-bong;Ahn Hyuk;Lee Byung Koo
    • Journal of Chest Surgery
    • /
    • v.38 no.11 s.256
    • /
    • pp.746-760
    • /
    • 2005
  • Background: Following the implantation of heart valve prostheses, it is important to maintain therapeutic INR to reduce the risk of thromboembolism. The objectives of this study were to determine the causes of nontherapeutic INRs, and to identify the factors associated with nonadherences to warfarin therapy in Korean outpatients with prosthetic heart valves managed by a pharmacist-run anticoagulation service (ACS). Material and Method: A retrospective chart review was completed for all patients enrolled in the ACS at Seoul National University Hospital from March, 1997b to September, 2000. The data on 868 patients (5,304 visits) who were at least 6 months post-valve replacement were included. All possible causes of nontherapeutic INRs were documented for each patient visit. The association of covariates to noncompliance was investigated by univariate analysis. Result: The reasons for nontherapeutic INRs were identified as follows: inadequate dosage adjustment $(21\%)$, nonadherences to dosing regimen $(13\%)$, drug/herbal interactions $(12\%)$, changes in diet $(7\%)$, and indeterminate cause $(42\%)$. Younger age, shorter duration of ACS and longer duration of warfarin therapy were associated with nonadherence. Conclusion: In this study, nonadherence and interactions between diet and medications were found to be important factors influencing nontherapeutic INRs. Longer duration of enrollment in the ACS affected the adherence to warfarin therapy Positively whereas younger age and longer duration of warfarin therapy affected negatively.

Congenital Quadricuspid Semilunar Valve - A case report - (선천성 사엽성 반월형 판막 - 1예 보고 -)

  • Seo, Min-Bum;Seo, Hong-Joo
    • Journal of Chest Surgery
    • /
    • v.42 no.3
    • /
    • pp.361-363
    • /
    • 2009
  • A 17-year-old male patient was referred with symptoms of dyspnea. Multi-detector computerized tomography (MDCT) and echocardiography evaluation revealed quadricuspid aortic and pulmonary valves, an atrial septal defect (ASD), and pulmonary stenosis. We closed the ASD using a bovine patch and performed a commissurotomy of the pulmonary valve. Quadricuspid semilunar valves are very rare congenital abnormalities that are reported to occur nine times more frequently in the pulmonic valve than in the aortic valve. According to the Hurwitz Roberts classification, the aortic valve was type A, and the pulmonic valve was type B. The aortic valve normal function, but the pulmonic valve was stenotic and had abnormal function.

Viability Assay after $4^{\circ}C$ Cold Preservation & Cryopreservation of Aortic & Pulmonic Allograft Valves in Rabbits (토끼의 대동맥 및 폐동맥 판막 동종이식편의 냉장 및 냉동 보존후 생육성 평가(I))

  • 홍종면
    • Journal of Chest Surgery
    • /
    • v.28 no.8
    • /
    • pp.731-741
    • /
    • 1995
  • Cardiac valve allografts have been used as replacements for diseased valves and right ventricular outflow tract reconstruction, the long term follow-up of which has been reported satisfactory. For a good long-term result, it is essential that the allograft be viable at implantation. In this study, we aimed at preparing the cardiac valve allografts aseptically, preserving them at cold- and cryo-conditions, and testing the viability of the allografts after preservation by four methods. We tested the viability of the cardiac valve allografts preserved in cold refrigerated state[4$^{\circ}$C in nutrient media & in liquid nitrogen tank[cryopreservation under -149$^{\circ}$C for pre-planned time periods. The testing methods were 1 glucose utility test 2 tissue culture 3 thymidine uptake test and 4 histologic evidence by light microscopy. We observed no differences in the viability between cold- & cryo-groups and similar results among the methods for testing the viability. In conclusion, there was no difference in the viability between cold- and cryopreserved-allografts at least for 14 days of preservation. And glucose utility test and thymidine uptake test were satisfactory in the evaluation of the allograft viability, since they were easy and rapid with relatively quantitative results.

  • PDF

Open Surgical Repair Using the Femoral Vein for a Mycotic Superior Mesenteric Artery Aneurysm

  • Namkoong, Min;Hong, Seok Beom;Kim, Hwan Wook;Jo, Keon Hyon;Kim, Jang Yong
    • Journal of Chest Surgery
    • /
    • v.51 no.3
    • /
    • pp.209-212
    • /
    • 2018
  • Superior mesenteric artery (SMA) aneurysms are rare and often fatal. A 72-year-old man had previously been admitted to the emergency room with epigastric pain and heart murmur. The echocardiographic diagnosis was vegetation on the aortic and mitral valves, with moderate regurgitation from both valves due to infective endocarditis. No aneurysm was detected on abdominal computed tomography, and emergency double-valve replacement was performed. On postoperative day 25, the patient experienced abrupt abdominal pain, and computed tomography revealed a mycotic SMA aneurysm. Open surgical repair of the SMA aneurysm was performed using the femoral vein, and the patient's postoperative course was uneventful.

Serum Enzyme Values after Extracorporeal Circulation (체외순환후의 혈청효소치 변동에 관한 연구)

  • Lee, Sang-Ho;Kim, Chong-Whan
    • Journal of Chest Surgery
    • /
    • v.14 no.2
    • /
    • pp.144-152
    • /
    • 1981
  • The effect of cardiopulmonary bypass procedures on the blood components were studied through the measurements of several serum enzymes, SGOT, SGPT, CPK and LDH with its isozymes in the patients who had surgery for their heart diseases. They wre 85 patients: 40 Males and 45 Females. Their ages ranged widely between one and fifty-six. They were divided into 5 groups: Group I.patent ductus arteriosus without extracorporeal circulation, Group II-atrial septal defect, Group III-ventricular septal defect, Group IV-tetralogy of Fallot, and Group V-valve replacement. Generally serum enzymes revealed the increased values after surgery and the tendency returning toward preoperative levels. With the high total serum LDH levels seen uniformly after operation which persisted long in patients with replaced valves, the changes of LDH-isozymes were further analyzed. The isozymes, especially LDI and LDs increased their activities postoperatively, and the other fractions varied little. And $LD_1$/$LD_2$ ratios also showed similar rises and falls while the elevated values lasted longer in the patients with cardiac valve replacement. The significant values of LDH-isozymes in predicting the hemolysis occuring after extracorporeal circulation and in following the patients whose valves were replaced have been further discussed with the special stress placed on the $LD_1$/$LD_2$ratios.

  • PDF

Viability Assay of Cardiac Allograft (I) (동종 동맥판의 생육성 평가에 관한연구(I))

  • 임창영
    • Journal of Chest Surgery
    • /
    • v.27 no.1
    • /
    • pp.1-8
    • /
    • 1994
  • Allograft cardiac valves have been used for over 30 years to replace diseased cardiac valves, reconstruct right or left ventricular outflow tract. With increasing its requirement, the establishment of a viable bank capable of maintaining the viability of graft over a prolonged period would be desirable. The method for determining the viability of allograft by metabolic assay technique using radiolabeled aminoacids has been used recently. An experimental study was done for evaluation of viability of cardiac allograft which was preserved for 14 days at 4oC in nutrient medium[fresh preservation] by metabolism assay technique using 3H-glycine. Also, the effectiveness of low concentration antibiotic solution[CLPV] for sterilization was evaluated. The effectiveness of CLPV solution for sterilization of allograft was perfect. Pre-treatment cultured organisms were not cultured after treatment at all in every cases. The viability of allograft after sterilization was reduced to 66.4%[aortic wall], 74.7%[pulmonary wall], 76.3%[aortic valve], 67.9%[aortic wall]. And after the fresh preservation for 14 days, the viability was reduced to 14.7%, 18.5%, 17.7%, 19.0%, respectively.In conclusion, viability of allograft was reduce to 71.3[66.4-76.3]% after sterilization and 17.5[14.7-19.0]% after fresh preservation. And sterilization effect of CLPV solution was satisfactory.

  • PDF

The Development of a New Polymer Valve for Artificial Blood Pumps (인공심장 및 심실보조장치용 고분자 인조판막의 개발)

  • Suh, S.W.;Wetering, J.E.v.d.;Park, Y.J.;Park, S.K.;Kim, I.Y.;Min, B.G.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1993 no.11
    • /
    • pp.104-106
    • /
    • 1993
  • Some cardio-vascular assist systems need more inexpensive artificial heart valves for short-term use. To meet with this need, we have developed a new polymer valve that is very simple to manufacture and of which its dimensions are easy to change, depending on its application. We have tested the hydrodynamic performance of the new polymer valve using a mock circulatory testing system and studied the flow through the valve using high-speed camera combined with image processing techniques. The results show that this valve is superior in its performances to the other valves (Bjork-Shiley mechanical valve and trileaflet polymer valve) and have no stagnation points. We also have tested the hemolytic potential of the valve. The valve is less hemolytic than the Bjork-shiley mechanical valve finally, we have applied this valve to a left ventricular assist device that we are developing.

  • PDF

Clinical experience of open heart surgery: 50 cases (개심술 치험 50례)

  • 정황규
    • Journal of Chest Surgery
    • /
    • v.16 no.1
    • /
    • pp.65-74
    • /
    • 1983
  • Fifty cases of open heart surgery were done in the Department of Thoracic and Cardiovascular Surgery, Busan National University Hospital during 16 months from July, 1981 to October, 1982. The clinical data were analyzed and summerized as follows. 1. There were 34 cases (68%) of congenital anomalies and 16 cases (32%) of acquired heart diseases. Among the congenital cases, 27 were acyanotic and 7 were cyanotic. All of the acquired heat diseases, 16 cases were valvular diseases and they had valvular replacement surgery. 2. The age distribution of the congenital anomalies ranged from 6 to 27 years with mean age of 14.2 years, and the acquired heart diseases from 18 to 44 years mean age of 27.5 years. The difference of sex distribution was no significance. 3. The clinical minifestations in acyanotic congenital anomalies were exertional dyspnea (81.5%), recurrent respiratory infection (55.6%) and palpitation (22.2%), and in cyanotic congenital anomalies were exertional dyspnea (100%), syncope(57.1%) and growth retardation(57.1%), and in acquired heart diseases were dyspnea(100%), edema (62.5%) and general weakness (62.5%) 4. During the cardiopulmonary bypass, mild to moderate core cooling was performed and added topical cooling for more accurate myocardial preservation. 5. Two kinds of cardioplegic solution used in our institute were Bretschneider solution for the first 7 cases and mixed Harmann's solution 1 L with glucose 5gm, potassium chloride 26 mEq and sodium bicarbonate 24 mEq, making 376 mosmol/L and pH 8.3 at $25^{\circ}C$, for the rest 43 cases. 6. Various kinds of postoperative complications occurred in 14 cases (28%) and showed overall mortality 12%. The mortality along with each disease was 7.4% in congenital acyanotic cases, 42.9% in congenital cyanotic cases and 6.3% in acquired valvular diseases. 7. Pre-and postoperative diagnostic incompatibility was seen in 6 cases (12%). 8. The artificial valves used in the replacement surgery were lonescu-Shiley bovine xenograft in 6 cases and Carpentier-Edwards porcine xenograft in 10 cases.

  • PDF

The Structure of the Ventricle in the Heart of the Pond Smelt, Hypomesus nipponensis (Osmeridae) (바다빙어과 빙어 (Hypomesus nipponensis)의 심실 구조)

  • Park, No Kwan;Reu, Dong Suck
    • Korean Journal of Ichthyology
    • /
    • v.27 no.3
    • /
    • pp.228-232
    • /
    • 2015
  • The structure of the ventricle in the heart of Hypomesus nipponensis was investigated by light and scanning electron microscope. The heart consisted of four consecutive chambers, the sinus venosus, atrium, ventricle and bulbus arteriosus. The wall of the ventricle was divided into endocardium, myocardium, subepicardium and epicardium. The valves were observed in the artrioventricular and bulboventricular junctions. The ventricular myocardium was an entirely spongy without coronary vessels. The trabecular network was formed with lumina included a central lumen and the trabecula was cylindrical shape. Collagen distribution was apparent in the subepicardium, artrioventricular valve and bulboventricular valve. But in the trabeculae, collagen distribution was observed partly in the base of the ventricle. Especially, the endocardial bridges were observed between trabeculae. These results might be considered that the structure of the ventricle in the heart of pond smelt is adapted to sedentary habit associated with its habitat and lifestyle.

Surgical management ofuniventricular heart (단일심실증의 수술요법)

  • No, Jun-Ryang;Kim, Eung-Jung
    • Journal of Chest Surgery
    • /
    • v.19 no.4
    • /
    • pp.618-626
    • /
    • 1986
  • Univentricular heart is a rare congenital cardiac anomaly in which the atrial chambers are connected to only one ventricular chamber and it consists of a diverse group of cardiac malformation characterized by both AV valves or a common AV valve opening into the same ventricle, or the presence of only a solitary AV valve. In spite of recent development in cardiac surgery, corrective operations for univentricular heart still have high mortality and complication rate. Twenty eight patients underwent corrective operation for univentricular heart at Department of Thoracic and Cardiovascular Surgery, Seoul National University Hospital from February 1979 to July 1986. Of the 28 patients, 7 patients were operated on by ventricular septation and 21 patients by modified Fontan operation. Of the 28 patients, 19 patients were male and 9 patients female and ages ranged from 5 months to 18 years old with the average age of 7.3 years. There were 2 mortalities in 7 patients operated on by septation with the mortality rate of 28.6% and 5 complications, 3 complete AV block, 1 low cardiac output and 1 arrhythmia. All survived patients are being followed up without specific problem till now. There were 10 mortalities in 21 patients operated on by modified Fontan operation with the mortality rate of 47.6% and 10 complications, 2 low cardiac output, 2 respiratory failure necessitating tracheostomy, 2 persistent cyanosis, 2 arrhythmia, 1 missing of left AV valve in situs inversus patient due to misdiagnosis and one rupture of closed right AV valve. Incremental risk factors for operative mortality are young age less than 5 years old, anomalous pulmonary and systemic venous drainage and atrial septation procedure. In 11 survived patients, 9 patients show good follow-up results but one patient complains of persistent cyanosis and another one patient is suffered from CHF. In our series, results of corrective operation for univentricular heart shows continuing improvement but still high mortality and complication rate. So there must be continuing improvement in surgical result by selection of patient, by adequate decision making for timing and method of operation and by improving operative methods.