• 제목/요약/키워드: Heart Sound

검색결과 146건 처리시간 0.032초

Psychological and Physiological Responses to the Rustling Sounds of Korean Traditional Silk Fabrics

  • Cho, Soo-Min;Yi, Eun-Jou;Cho, Gil-Soo
    • Fibers and Polymers
    • /
    • 제7권4호
    • /
    • pp.450-456
    • /
    • 2006
  • The objectives of this study were to investigate physiological and psychological responses to the rustling sound of Korean traditional silk fabrics and to figure out objective measurements such as sound parameters and mechanical properties determining the human responses. Five different traditional silk fabrics were selected by cluster analysis and their sound characteristics were observed in terms of FFT spectra and some calculated sound parameters including level pressure of total sound (LPT), Zwicker's psychoacoustic parameters - loudness(Z), sharpness(Z), roughness(Z), and fluctuation strength(Z), and sound color factors such as ${\Delta}L\;and\;{\Delta}f$. As physiological signals, the ratio of low frequency to high frequency (LF/HF) from the power spectrum of heart rate variability, pulse volume (PV), heart rate (HR), and skin conductance level (SCL) evoked by the fabric sounds were measured from thirty participants. Also, seven aspects of psychological state including softness, loudness, sharpness, roughness, clearness, highness, and pleasantness were evaluated when each sound was presented. The traditional silk fabric sounds were likely to be felt as soft and pleasant rather than clear and high, which seemed to evoke less change of both LF/HF and SCL indicating a negative sensation than other fabrics previously reported. As fluctuation strength(Z) were higher and bending rigidity (B) values lower, the fabrics tended to be perceived as sounding softer, which resulted in increase of PV changes. The higher LPT was concerned with higher rating for subjective loudness so that HR was more increased. Also, compression linearity (LC) affected subjective pleasantness positively, which caused less changes of HR. Therefore, we concluded that such objective measurements as LPT, fluctuation strength(Z), bending rigidity (B), and compression linearity (LC) were significant factors affecting physiological and psychological responses to the sounds of Korean traditional silk fabrics.

태아 포노그램을 위한 전자청진장치의 개발 (Development of Electronic Stethoscope System for Fetal Phonogram)

  • 김동준
    • 한국정보전자통신기술학회논문지
    • /
    • 제2권3호
    • /
    • pp.9-15
    • /
    • 2009
  • 분만시 국내에서 영아 사망률은 약 1%에 이르고, 태아의 질병 발생과 사망은 계속적으로 일어나고 있으므로 저가의 태아 모니터링기술의 개발이 절실하다. 이를 위하여 본 연구에서는 임산부의 복부로부터 태아의 움직임과 심음을 검출할 수 있는 증폭기를 설계하여 고성능 태아 포노그램용 전자청진장치를 개발하고자 한다. 장치로부터 검출된 태아의 청진 신호는 듣거나 녹음할 수 있으며, PC에서 태아의 심음을 분석할 수도 있다. 개발된 증폭기를 이용하여 잡음에 노출된 일반 대학병원 환경에서 30명의 임산부를 대상으로 임상실험을 수행한 결과, 개발된 증폭기는 저잡음, 고이득의 특성을 나타내고, 임산부 중에서 빠른 경우 22주에서도 태아의 심음을 검출할 수 있었고, 심음의 주기검출이 가능하였다.

  • PDF

Management of Pulmonary Hypertension Due to Brachycephalic Obstructive Airway Syndrome in a Dog

  • Song, Yunji;Kim, Yeji;Kim, Jihyun;Kim, Kwon-Neung;Oh, Songju;Kim, Ha-Jung
    • 한국임상수의학회지
    • /
    • 제39권5호
    • /
    • pp.240-245
    • /
    • 2022
  • A 15-year-old, neutered male, Shih-Tzu, was presented at the Chonnam National Veterinary Medical Teaching Hospital for evaluation of acute onset of persistent coughing, exercise intolerance, and abnormal heart sound. On thoracic auscultation, a split-second heart sound and a wheezing sound were detected on both sides of the chest walls. On physical examination, the dog's body condition score (BCS) was 7/9, and had stenotic nares. Thoracic radiographs revealed right-sided enlargement of the cardiac silhouette (vertebral heart score (VHS) 11.2; reference interval = 8.9-10.1), mild main pulmonary artery (MPA) bulging, mild interstitial infiltration, and hepatomegaly. The electrocardiogram showed right axis deviation, suggesting right ventricular hypertrophy. The echocardiographic study showed moderate pulmonary hypertension and moderate tricuspid regurgitation. There were no findings of a tracheobronchial disease, pulmonary thromboembolism, congenital shunt, left heart disease, or parasitic disease. Based on clinical signs and diagnostic findings, the dog was diagnosed with pulmonary hypertension secondary to brachycephalic syndrome. To rectify respiratory exacerbating factors, the dog was recommended weight control by restricting dietary intake and managing concurrent Cushing's syndrome. Treatments included sildenafil, pimobendan, furosemide, and ramipril. After five months of taking medications and weight control, the severity of pulmonary hypertension improved from moderate to mild. The clinical signs of the patient, including coughing and exercise intolerance, improved a lot. For 5 months of follow-up, the patient has not reported further recurrence of respiratory distress.

심전도와 심음을 측정하기 위한 무선 전자 심전도-심음 청진기 개발 (Development of Wireless Electronic Cardiogram and Stethoscope (ECGS) to Measure ECG Signal and Heart Sound)

  • 조한석;강영환;박재순;최진규;정연호;구치완
    • 대한의용생체공학회:의공학회지
    • /
    • 제43권2호
    • /
    • pp.124-130
    • /
    • 2022
  • In this paper, we proposed a portable electronic cardiogram and stethoscope (ECGS) that can simultaneously perform the electrocardiogram (ECG) and auscultation tests to increase the reliability of diagnosis of heart disease. To measure the ECG and heart sound (HS) at the same time, three ECG electrodes and a microphone sensor were combined into a triangular shape with a width of 90 mm and a height of 97 mm that can be held in one hand. In order to prevent skin problems when they contact the patient's skin, a capacitive coupled electrode was selected as the ECG electrode and a silicone material was used in a chest piece with the microphone sensor. For the signals measured from the electrodes and the chest piece, filters were respectively configured to pass only the signals of 0.01-100 Hz and 20-250 Hz, which are frequency bands for ECG and HS. The filtered ECG and HS analog signals were converted into digital signals and transmitted to a PC using wireless communication for monitoring them. The HS could be auscultated simultaneously using an earphone. The monitored ECG had an SNR of about 34 dB and a P-QRS-T waveform is clearly visible. In addition, the HS had an SNR of about 28 dB and both S1 and S2 are clearly visible. It is expected that it can aid doctors' inexperience in analyzing the ECG and HS.

실험동물(實驗動物)의 심박계측법(心搏計測法) (Methods for Recording and Counting the Heart Rate of Intact Animal and Isolated Preparations)

  • 장황남
    • 대한약리학회지
    • /
    • 제4권1호
    • /
    • pp.37-39
    • /
    • 1968
  • A method for presenting the heart rate of intact animals as a kymographic record is described. A transistorized impulse generator with a dry battery power supply is used to produce pulses. The pulses are integrated and make a pen motor drived. The ability of the instrument to follow a wide range of heart rate change is demonstrated. The instrument is especially usefull to observe an acute and transitory heart rate change. A method for changing the heart beat to sound and a method for counting the heart rate of intact animal and isolated preparations by employing post office counter were also described.

  • PDF

인공판막의 판막음 스펙트럼 분석방법 비교 (Comparison of Spectral Analysis Methods of Prosthetic Heart Valve Sound)

  • 이희종;김상현;장병철;탁계래;조범구;유선국
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1997년도 춘계학술대회
    • /
    • pp.402-405
    • /
    • 1997
  • The analysis of heart sounds is a noninvasive diagnostic method useful to diagnose heart valve function. In this paper we compared the ability of spectral analysis method for prosthetic heart valve sounds. Phonocardiograms of prosthetic heart valve were analyzed in order to derive frequency domain feature suitable for the classification of the valve state. The FFT-based methods did not provide sufficient frequency resolution to completely characterize the spectrum of prosthetic heart valve sounds. A high resolution parametric methods were shown to give superior frequency resolution. In parametric methods, all methods provide a 1st & 2nd & 3rd frequency component. But Shank method provided a most dominant frequency peak.

  • PDF

소아 선천성 심질환 진단을 위한 성대 진동 분석 요소의 적용 (Application of Vocal Fold Vibration Analysis Parameter for Infant Congenital Heart Diseases Diagnosis)

  • 김봉현;조동욱
    • 한국산학기술학회논문지
    • /
    • 제10권10호
    • /
    • pp.2708-2714
    • /
    • 2009
  • 언어를 통한 의사 전달 능력이 부족한 영아나 소아들은 울음으로서 자신의 몸의 상태나 요구하는 것에 대한 의사 표시를 행한다. 이 중 중요한 것이 소아 상태를 나타내는 것인데 언어 전달 능력이 없는 소아들의 질병은 진단 시기를 놓치거나 정확한 진단 결과를 내리기 어려운 문제가 존재한다. 이를 위해 본 연구에서는 소아의 울음소리를 분석하여 몸의 어느 부위가 문제가 있는지를 판단해 내는 소아 청진 시스템을 개발하였다. 특히 본 논문에서는 울음소리의 피치, 강도 및 스펙트럼 분석을 통해 소아 선천성 심질환자에 대한 질병 진단을 수행하였다. 이를 위해 각각의 분석 요소를 통해 정상적인 아이와 소아 선천성 심질환을 앓고 있는 아이에 대한 울음소리의 비교, 분석을 수행하였다. 이와 같은 방법을 통해 의사표현 능력이 부족한 소아를 대상으로 편리하게 소아 선천성 심질환을 진단할 수 있으며 임상 자료의 추가 실험을 통해 울음소리 기반의 재택형 진단 시스템을 구축할 수 있다.

뉴럴네트워크를 이용한 심음의 정상 비정상 분류 (Classificatin of Normal and Abnormal Heart Sounds Using Neural Network)

  • 윤희진
    • 융합정보논문지
    • /
    • 제8권5호
    • /
    • pp.131-135
    • /
    • 2018
  • 현대인의 사망원인 2위를 차지하고 있는 심장병은 자각 증세 없이 갑자기 돌연사를 당할 수 있는 무서운 질병으로 예방이 중요하다. 심장병 중 대동맥판막 협착증을 판단하기 위해서 physioNet에서 제공하는 심음 데이터 중 S1과 S2 사이의 수축 심음 데이터를 이용하여 병명을 진단하였다. 대동맥 판막은 좌심실에서 대동맥으로 피가 유출되는 부위의 판막이다. 심장병 중 대동맥판막 협착증은 대동맥판막이 좁아져 좌심실의 수축 시 판막이 열리지 않는 질환이다. 위 논문에서는 정상인과 대동맥판막 협착증 환자를 합쳐 특징이 180개로 이루어진 3126개의 샘플 심음 데이터를 실험데이터로 사용하였다. 정상과 대동맥판막 협착증 환자를 구분하기 위해 가중퍼지신경망(NEWFM, Neural Network with Weighted Fuzzy Membership Function)이용하였다. 가중퍼지신경망의 특징선택 방법으로 가중치의 평균 방법을 이용하였으며, 분류 결과는 91.0871%의 정확도를 나타내었다.

심음 향상을 위한 단일채널 적응 잡음 제거기 (Adaptive Noise Canceller of Single Channel For Heart Sound Enhancement)

  • 이철현;김필운;이윤정;장용민;배건성;조진호;김명남
    • 한국멀티미디어학회논문지
    • /
    • 제13권7호
    • /
    • pp.973-982
    • /
    • 2010
  • 본 논문에서는 심음 향상을 위해 단일 채널 적응 잡음 제거기를 제안한다. 청진음은 일상적이거나 응급 상황 시 다양한 소리가 섞여 심음의 판독이 어려운 특징이 있다. 기존의 두 채널의 입력을 가지는 적응 잡음 제거기에서 단일 채널의 구현을 위해 단일 채널로 입력된 청진음은 심음의 특징을 기반을 둔 HS 분석기와 BS-Gate를 제안하여 기준 신호를 생성하였다. 제안한 단일 채널 적응 잡음 제거기는 BIOPAC Systems, Inc의 SS30L과 MP 36을 이용하여 획득한 청진음을 이용하여 실험하였으며, 그 결과 효과적으로 호흡음이 감쇄하여 심음이 향상되는 것을 확인할 수 있었다. 또한 단일 채널을 사용하는 적응 선 스펙트럼 강조기와의 비교 실험을 통해 심박의 변화에도 효과적으로 잡음을 제거하였음을 확인할 수 있었다.

자발성 종격동 기흉: 작게 청진된 심음을 주소로 내원한 신생아 (Decreased heart sound in a healthy newborn: Spontaneous multiseptated cystic pneumomediastinum with delayed respiratory distress)

  • 최영준;김은선;김이경;김한석;천정은;김우선;김인원;최중환
    • Clinical and Experimental Pediatrics
    • /
    • 제53권2호
    • /
    • pp.244-247
    • /
    • 2010
  • 자발성 종격동 기흉은 신생아기에 발생하는 호흡곤란의 드문 원인 중의 하나이며 대부분의 증례에서는 인공호흡, 출산손상, 태변흡입 등이 선행하는 경우가 많으며, 또한 대다수가 미숙아로 알려져있다. 저자들은 신생아 진찰 중 심음이 적게 들리는 소견으로 발견되었던, 위와 같은 위험인자가 없는 건강한 만삭아에서 발생한 자발성 종격동 기흉 1예를 경험하였기에 이를 보고하는 바이다.