• Title/Summary/Keyword: Heart/ artificial

Search Result 336, Processing Time 0.025 seconds

The Effect of AI Experience Program Using Teachable Machine on AI Perception of Elementary School Students (Teachable machine을 활용한 인공지능 체험 프로그램이 초등학생의 인공지능 인식에 미치는 영향)

  • Lee, Seung-mee;Chun, Seok-Ju
    • Journal of The Korean Association of Information Education
    • /
    • v.25 no.4
    • /
    • pp.611-619
    • /
    • 2021
  • Artificial intelligence is at the heart of the Fourth Industrial Revolution. Education must change in order to develop the capabilities necessary for future AI-based societies. This study developed and applied artificial intelligence experience classes using Teachable machine to elementary school students, and analyzed changes in artificial intelligence understanding and interest among students. Among the 10 artificial intelligence classes, 4 classes used various artificial intelligence education platforms, and 6 classes focused on Teachable machines. Before and after the application of the program, students' interest and understanding in artificial intelligence were examined. Quantitative and qualitative studies were conducted together. Studies have shown that both students' interest and understanding of artificial intelligence has improved since the application of the program. Furthermore, based on the findings, we propose a follow-up study for the development of artificial intelligence training programs.

Surgical Technique for Korean Artificial Heart(AnyHeart) Implantation Using a Right Thoracotomy Approach (우측 개흉술을 이용한 한국형 인공심장(AnyHeart)의 이식기법)

  • Son. Ho-Sung;Sun, Kyung;Shin, Jae-Seung;Lee, Sung-Ho;Jung, Jae-Seung;Lee, Hye-Won;Kim, Kwang-Taik;Kim, Seung-Chul;Won, Yong-Soon;Min, Byoung-Goo;Kim, Hyoung-Mook
    • Journal of Chest Surgery
    • /
    • v.35 no.5
    • /
    • pp.329-335
    • /
    • 2002
  • Background: The surgical technique for biventricular assist device(BVAD) implantation has mainly consisted of cannulation procedures. A median sternotomy has been the technique of choice as it gives a surgeon an excellent exposure of the heart. However, considering that most patients require a future sternotomy or already have a previous sternotomy, sternotomy-related complication remains a major concern in BVAD implantation. Based on this consideration as well as the clinical experiences of conventional heart surgery, the authors have hypothesized that the cardiac chambers for BVAD cannulation can be approached from the right side of the heart. The purpose of this studs to develop a novel surgical technique of right thoracotomy for BVAD implantation in an animals study. Material and Method: For last two years, 16 (11 calves, 3 canines, and 2 sheep) out of 30 experimental animals with AnyHeart implantation underwent a right thoracotomy. The device was used as an implantable BVAD in 14 animals, a wearable BVAD in 1, and an implantable LVAD in 1. The chest cavity was entered through the 4th intercostal space or the 5th periosteal bed. As for the BVAD use, a right inflow cannula was inserted into the right atrial free wall and a right outflow cannula was grafted onto the main pulmonary artery. A left inflow cannula was inserted into the interatrial groove and a left outflow cannula was grafted on the innominate artery of the ascending aorta. The connecting tubes were brought out through the thoracotomy wound and connected to the pump located in the subcutaneous pocket at the right flank. Result: Except for the 5 animals for a lilting test or during the early learning curve, all recovered smoothly from the procedures. The inflow drainage allowed the pump output 6.5 L/min at the maximum with 3-3.5 L/min in an average. Of the survivors, there noted no procedure-related mortality or morbidity. Necropsy findings demonstrated the well-positioned cannula tips in the each cardiac chamber

Clinical experience of open heart surgery: 50 cases (개심술 치험 50례)

  • 정황규
    • Journal of Chest Surgery
    • /
    • v.16 no.1
    • /
    • pp.65-74
    • /
    • 1983
  • Fifty cases of open heart surgery were done in the Department of Thoracic and Cardiovascular Surgery, Busan National University Hospital during 16 months from July, 1981 to October, 1982. The clinical data were analyzed and summerized as follows. 1. There were 34 cases (68%) of congenital anomalies and 16 cases (32%) of acquired heart diseases. Among the congenital cases, 27 were acyanotic and 7 were cyanotic. All of the acquired heat diseases, 16 cases were valvular diseases and they had valvular replacement surgery. 2. The age distribution of the congenital anomalies ranged from 6 to 27 years with mean age of 14.2 years, and the acquired heart diseases from 18 to 44 years mean age of 27.5 years. The difference of sex distribution was no significance. 3. The clinical minifestations in acyanotic congenital anomalies were exertional dyspnea (81.5%), recurrent respiratory infection (55.6%) and palpitation (22.2%), and in cyanotic congenital anomalies were exertional dyspnea (100%), syncope(57.1%) and growth retardation(57.1%), and in acquired heart diseases were dyspnea(100%), edema (62.5%) and general weakness (62.5%) 4. During the cardiopulmonary bypass, mild to moderate core cooling was performed and added topical cooling for more accurate myocardial preservation. 5. Two kinds of cardioplegic solution used in our institute were Bretschneider solution for the first 7 cases and mixed Harmann's solution 1 L with glucose 5gm, potassium chloride 26 mEq and sodium bicarbonate 24 mEq, making 376 mosmol/L and pH 8.3 at $25^{\circ}C$, for the rest 43 cases. 6. Various kinds of postoperative complications occurred in 14 cases (28%) and showed overall mortality 12%. The mortality along with each disease was 7.4% in congenital acyanotic cases, 42.9% in congenital cyanotic cases and 6.3% in acquired valvular diseases. 7. Pre-and postoperative diagnostic incompatibility was seen in 6 cases (12%). 8. The artificial valves used in the replacement surgery were lonescu-Shiley bovine xenograft in 6 cases and Carpentier-Edwards porcine xenograft in 10 cases.

  • PDF

A Comparison of Cardio-Pulmanary Function by the use of a Single Axis Foot and SACH Foot in Below-Knee Amputation (하퇴 절단 환자의 족부 종류에 따른 심폐 기능의 비교)

  • Ahn, Wang-Hun;Kim, Young-Hee
    • Journal of Korean Physical Therapy Science
    • /
    • v.7 no.1
    • /
    • pp.311-319
    • /
    • 2000
  • This study was to measure whether single axis foot or the SACH foot applied to below-knee amputation patients would bring positive changes to the patients' cardiopulmonary function, and help them to overcome their disability. The experiment took place at Asan Medical Center, University of Ulsan, from July 20th to November 20th, 1999 with 10 below-knee amputation patients. The patients were asked to equip single axis foot and SACH foot by turns and lead them to walk on a treadmill which was designed to increase its steep slope. Patients heart rate and blood pressure were recorded before and after their walking, The heart rate, systolic blood pressure, diastolic blood pressure of the patients who were equipped with, either SACH foot or single axis foot, have been increased with as the slant becoming steeper. The heart rates during the experiment did not show relevant changes according to the kind of foot used and the gradient, but the changes occurred before and after the walking(p=0.0001), The similar result of systolic blood pressure was found during the waking(p=0.01). Below-knee amputation patients are expected to walk and perform the routines better, no matter what type of foot is used, as long as they wear an artificial foot properly and taking features of foot product into consideration

  • PDF

Development and Evaluation of a Novel Electro-mechanical Implantable Ventricular Assist System (전기-기계식 이식형 좌심실 보조 시스템의 개발 및 평가)

  • 조한상;김원곤;이원용;곽승민;김삼성;김재기;김준택;류문호;류은숙
    • Journal of Biomedical Engineering Research
    • /
    • v.22 no.4
    • /
    • pp.349-358
    • /
    • 2001
  • A novel electro-mechanical implantable ventricular assist system is developed as a bridge to transplantation or recovery for patients with end-stage heart failure. The developed system is composed of an implanted blood pump, an external monitoring system which stores data, and a wearable system including a portable external driver and a portable power supply system. The blood pump is designed to be implanted into the left upper abdominal space and provides blood flow from the left ventricular apex to the aorta. The pulsatile blood flow is generated by a double cylindrical cam. There was mo excessive heat emission from the blood pump into the temperature-controlled chamber in the heat test and no stagnated flow within the blood sac by the observation in the flow visualization test. Animal experiments were performed using sheep and calves. The maximum assist flow rate reached 7.85L/min in the animal experiment. The evaluation results showed that the developed system was feasible for the implantable ventricular assist system. The long-term in vitro durability test and mid-term in vivo experiments are in progress and mow the modified next model is under development.

  • PDF

Effects of sleep deprivation on coronary heart disease

  • Wei, Ran;Duan, Xiaoye;Guo, Lixin
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.26 no.5
    • /
    • pp.297-305
    • /
    • 2022
  • The presence of artificial light enables humans to be active 24 h a day. Many people across the globe live in a social culture that encourages staying up late to meet the demands of various activities, such as work and school. Sleep deprivation (SD) is a severe health problem in modern society. Meanwhile, as with cardiometabolic disease, there was an obvious tendency that coronary heart disease (CHD) to become a global epidemic chronic disease. Specifically, SD can significantly increase the morbidity and mortality of CHD. However, the underlying mechanisms responsible for the effects of SD on CHD are multilayered and complex. Inflammatory response, lipid metabolism, oxidative stress, and endothelial function all contribute to cardiovascular lesions. In this review, the effects of SD on CHD development are summarized, and SD-related pathogenesis of coronary artery lesions is discussed. In general, early assessment of SD played a vital role in preventing the harmful consequences of CHD.

FUZZY Gain Tuning of PI Speed Controller Depending on Afterloads In Total Artificially Heart

  • Choi, Jong-Hoon;Choi, Won-Woo;Choi, Jae-Soon;Om, Kyong-Sik;Lee, Jung-Hoon;Min, Byoung-Goo
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.05
    • /
    • pp.156-160
    • /
    • 1997
  • In this paper, the control scheme is proposed that PI controller parameter used for TAH speed control is adapted by fuzzy logic method using only the motor current waveform. By scheduling PI parameters, minimization of the vibration and the energy consumption and overcoming AoP loads becomes possible. In in vitro tests experimental results show our approach is a good scheme that is adapted to changing afterloads well.

  • PDF

Surgical Repair of Atrial Septal Defect Using Extracorporeal Circulation: One Case Report (심폐기를 이용한 심방중격결손의 외과적 교정: 1례 보고)

  • 이동준
    • Journal of Chest Surgery
    • /
    • v.10 no.1
    • /
    • pp.143-147
    • /
    • 1977
  • Atrial septal defect is the most common of the congenital heart disease in the adult. Since the first description of atrial septal defect by Rokitansky in 1857, this anomaly has been studied by many workers in past one century. In 1953, Lewis had first corrected the atrial septal defect under direct vision with deep hypothermia, and Gibbon [1954] had first done the atrial septal defect under direct vision with extracorporeal circulation. In our college [May 2’ 1977], we have first repaired the A.S.D. under direct vision with artificial heart-lung machine and, the defect was 4x5cm in size which was closed by Dacron patch. This patient was 12 year old girl who is well now. [postoperative 13 days]

  • PDF

Development of a Cardiovascular Simulator Focused on the Pressure Wave (혈압파형에 초점을 맞춘 심혈관계 시뮬레이터의 개발)

  • Lee, Ju-Yeon;Jang, Min;Shin, Sang-Hoon
    • Journal of Biomedical Engineering Research
    • /
    • v.34 no.1
    • /
    • pp.40-45
    • /
    • 2013
  • The conventional simulators used the expensive commercial artificial heart with a limited performance, and focused on replicating the heart function. The arterial pressure is the key factor of the cardiovascular disease. The purpose of this study is to develop a simulator focused on the pressure wave. The simulator is composed of a step motor, slider-crank mechanism, piston-cylinder, two check valves, a elastic tube, and two reservoirs. With the changes of design parameters, the functions of the simulator were evaluated. The simulator shows the good agreement of the characteristics of the cardiovascular system.

Development of wearable devices and mobile apps for fall detection and health management

  • Tae-Seung Ko;Byeong-Joo Kim;Jeong-Woo Jwa
    • International Journal of Advanced Culture Technology
    • /
    • v.11 no.1
    • /
    • pp.370-375
    • /
    • 2023
  • As we enter a super-aged society, studies are being conducted to reduce complications and deaths caused by falls in elderly adults. Research is being conducted on interventions for preventing falls in the elderly, wearable devices for detecting falls, and methods for improving the performance of fall detection algorithms. Wearable devices for detecting falls of the elderly generally use gyro sensors. In addition, to improve the performance of the fall detection algorithm, an artificial intelligence algorithm is applied to the x, y, z coordinate data collected from the gyro sensor. In this paper, we develop a wearable device that uses a gyro sensor, body temperature, and heart rate sensor for health management as well as fall detection for the elderly. In addition, we develop a fall detection and health management system that works with wearable devices and a guardian's mobile app to improve the performance of the fall detection algorithm and provide health information to guardians.