• Title/Summary/Keyword: Hearing aids

Search Result 143, Processing Time 0.024 seconds

Design of Implantable Middle Ear Hearing Aids Using an Electromagnetic Transducer (전자 트랜스듀서 방식에 의한 청각보조용 이식형 인공중이 시스템 설계)

  • Cho, Jin-Ho;Song, Byung-Seop;Kim, Myoung-Nam;Won, Chul-Ho;Park, Se-Kwang;Lee, Sang-Heun
    • Journal of Sensor Science and Technology
    • /
    • v.6 no.6
    • /
    • pp.466-475
    • /
    • 1997
  • In this paper, an implantable middle ear hearing aids using an electromagnetic transducer which consists of a tiny coil and a magnet is designed, and objective design method to implement a vibrator of the electromagnetic type transducer is proposed. Sound characteristic of the electromagnetic type vibrator is excellent but power transfer rate is lower than that of a ceramic type. To improve power transfer efficiency of system, external and inner part of a middle ear system is designed using FM transmission method. We implemented an experimental set of the designed transducer, inner part, and outer part. Then, we measured vibration characteristics of a metal strip and a temporal bone of a dead body. As the results, we confirmed the advantage of FM method and showed that designed transducer could effectively transmit vibration of amplified input sound pressure to ossicle.

  • PDF

A Combined Acoustic Feedback and Noise Cancellation Algorithm for Digital Hearing Aids (디지털 보청기를 위한 음향궤환 몇 잡음 제거 알고리즘)

  • Lee, Haeng-Woo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.35 no.11C
    • /
    • pp.911-916
    • /
    • 2010
  • This paper proposes a new algorithm to cancel the acoustic feedback and noise signals in digital hearing aids. The proposed algorithm combines the feedback canceller to remove acoustic feedback signals and the noise canceller to reduce background noises. The feedback canceller is implemented by normal adaptive FIR filter, and the noise canceller is implemented by using the Wiener solution in frequency domain. This noise canceller has the transfer function presented by the power spectral density of signals. To verify the performances of the proposed algorithm, the simulations were carried out for the system. As the results of simulations, it was proved that we can advance 10.85dB output SNR on the average for the forward path gain of 0dB, and 11.04dB output SNR on the average for the forward path gain of 6dB, in the case of using the proposed algorithm.

Low-Power Implementation of A Multichannel Hearing Aid Using A General-purpose DSP Chip (범용 DSP 칩을 이용한 다중 채널 보청기의 저전력 구현)

  • Kim, Bum-Jun;Byun, Joon;Park, Young-Cheol
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.11 no.1
    • /
    • pp.18-25
    • /
    • 2018
  • In this paper, we present a low-power implementation of the multi-channel hearing aid system using a general-purpose DSP chip. The system includes an acoustic amplification algorithm based on Wide Dynamic Range Compression (WDRC), an adaptive howling canceller, and a single-channel noise reduction algorithm. To achieve a low-power implementation, each algorithm is re-constructed in forms of integer program, and the integer program is converted to the assembly program using BelaSigna(R) 250 instructions. Through experiments using the implementation system, the performance of each processing algorithm was confirmed in real-time. Also, the clock of the implementation system was measured, and it was confirmed that the entire signal processing blocks can be performed in real time at about 7.02MHz system clock.

Study and Effects of Bone Conducted Signal on the Implantable Microphone (골전도를 통한 생체신호가 이식형 마이크로폰에 미치는 영향 및 고찰)

  • Woo, S.T.;Jung, E.S.;Kim, M.N.;Cho, J.H.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.4 no.1
    • /
    • pp.29-34
    • /
    • 2010
  • The fully implantable hearing devices (FIHDs) have been studied to compensate the defect of conventional hearing aids. Typically, a microphone for FIHDs was implanted under the skin of the temporal bone. So, implantable microphone characteristics can be affected by the eating food, chattering teeth and moving artifact. In this paper, we fabricated the physical model that was similar to characteristics of human temporal bone and skin, and we measured implanted microphone sensitivity for effect of bone conducted noise signal. For the measurement of microphone sensitivity, we applied 1 kHz pure sounds that were transmitted to implanted microphone and sine wave vibrations of varied frequency were simultaneously transmitted through the artificial bone. As a result, sensitivity of implanted microphone can be modified by bone conducted signal and this phenomenon was confirmed at varied frequency band.

Prediction of the Noise Levels for a Newly-founded Petrochemical Plant (신설 석유화학 공장의 소음도 예측)

  • 윤세철;이해경
    • Journal of the Korean Society of Safety
    • /
    • v.11 no.4
    • /
    • pp.135-142
    • /
    • 1996
  • Prolonged in-plant personnel exposure to high noise levels results in permant hearing damage. There are no way to correct this hearing damage by treatment or use of hearing aids. Therefore, every employer is responsible for providing a workplace free of such hazards as excessive noise. This study was carried out to evalute and predict a given noise environment based on specific limit as the noise guarantee for a newly-founded petrochemical plant. The maximum total sound level should not exceed 85dBA in the work area, except where the area is defined as a restricted area and 70dBA at the plant boundary. Prediction of the noise levels within the plant area for a newly-founded petrochemical plant was achieved by dividing all plant area into 20m$\times$20m regular grid spaces and noise level inside the area or unit that in-plant personel exposure to high noise levels was estimated computed into 5m$\times$5m regular grid spaces. The noise level at the grid point that was propagated from each of the noise sources(equipments) computed using the methematical formula was defined as follows : $SPL_2$=$SPL_1-20log{\frac{r_2}{r_1}}$(dB) where $SPL_1$ =sound pressure level at distance $r_1$ from the source $SPL_2$=sound pressure level at distance $r_2$ from the source As a result, the equipments exceeded noise limit or irritaring noise levels were identified on the specific grid coordinates. As for equipments in the area that show high noise levels, appropriate counter-measures for noise control (by barriers, enclosure, silencers, or the change of equipments, for example) should be reviewed. Methods for identifying sources of noise applied in this study should be the model for prediction of the noise levels for any newly-founded plant.

  • PDF

Development of a Sign Language Learning Assistance System using Mediapipe for Sign Language Education of Deaf-Mutility (청각장애인의 수어 교육을 위한 MediaPipe 활용 수어 학습 보조 시스템 개발)

  • Kim, Jin-Young;Sim, Hyun
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.16 no.6
    • /
    • pp.1355-1362
    • /
    • 2021
  • Recently, not only congenital hearing impairment, but also the number of people with hearing impairment due to acquired factors is increasing. The environment in which sign language can be learned is poor. Therefore, this study intends to present a sign language (sign language number/sign language text) evaluation system as a sign language learning assistance tool for sign language learners. Therefore, in this paper, sign language is captured as an image using OpenCV and Convolutional Neural Network (CNN). In addition, we study a system that recognizes sign language behavior using MediaPipe, converts the meaning of sign language into text-type data, and provides it to users. Through this, self-directed learning is possible so that learners who learn sign language can judge whether they are correct dez. Therefore, we develop a sign language learning assistance system that helps us learn sign language. The purpose is to propose a sign language learning assistance system as a way to support sign language learning, the main language of communication for the hearing impaired.

PCB design for ITE digital hearing aids manufacture (귀속형 디지털 보청기 제작을 위한 PCB 설계)

  • Jarng Soon Suck;Kim Kyoung Suck
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • autumn
    • /
    • pp.235-238
    • /
    • 2004
  • 대부분의 보청기 이용자들은 자신이 장애를 겪고 있다는 사실이 알려지는 것을 꺼린다. 따라서 보청기 사용자들은 귀 바깥쪽으로 들어 나지 않는 귓속형(ITE type) 보청기를 선호한다. 하지만, 이러한 귓속형 보청기를 제작하는 것은 쉬운 일이 아니다. 보청기의 각각 부품들만을 볼 때는 그 크기가 소형이지만, 부품 모두를 귀속에 넣는다고 한다면, 공간의 확보는 꼭 필요한 사항이다. 또한 보청기는 하나의 칩(chip)에 부품이 전선(wire)을 통해 납땜이 되는 구조이다. 이는 전선의 단락을 유발할 뿐만 아니라 칩과 전선이 쉽게 떨어지며, 잦은 납Eoa 작업으로 인해 열적으로 칩의 파손까지도 일으킨다. 이를 보안하고자 여기에서는 보청기 소형화 방법으로 PCB(Printed Circuit Board)를 제시하였다. PCB 를 사용함으로써 전선의 사용을 최소화하고, 부품과 PCB 와의 직접적인 결합으로 인해 보다 견고한 보청기 제작을 목표로 하였다. 아울러 PCB 를 통한 부품의 실장으로 기존의 수작업이던 보청기 제작을 자동화와 제작 시간의 단축이라는 이점을 얻을 수 있다.

  • PDF

Risk Perception Associated with Noise Exposure on Pilots & Ground-crews in the Korean Air Force (공군 작업자들의 소음 폭로와 관련된 위험인지)

  • 강윤성;박상규
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.610-615
    • /
    • 2002
  • This study is to evaluate the risk perception of noise of the ground-crews in the Korean airbases who exposed to noise of jet plane. 1148 ground-crews and 231 pilots of 2 airbases participated in this study. The questionnaires of risk perception with visual analogue scale were completed by the participants. For comparison, the perception of other risks such as beef contaminated with dioxin, AIDS, lung cancer, otitis media, shigellosis, driving, drinking, and smoking were also included in the questionnaire of risk perception. The results of this study suggested the necessity of risk communication about noise and activation of effective hearing conservation program in the Korean air-force.

  • PDF

Implement and Effects of Pronunciation Correction App for Teenagers with Hearing Aids (청력보조기를 이식받은 청소년을 위한 발음교정 앱 구현과 효과 정리)

  • Shin, Ji-Woo;Lee, Ji-Oun;Im, Jisu;Lim, Sung-Hyun
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2017.11a
    • /
    • pp.1045-1048
    • /
    • 2017
  • 기존에 있는 발음연습 앱이 청소년 청각장애인이 언어치료용으로 사용하기에 부적절한 이유와 그들에게 맞는 언어치료 앱 도입 필요 이유를 설명한다. 현장에서 일하시는 언어치료사와 청각장애인의 의견을 수용하여 개발한 청소는 청각장애인을 위한 앱의 시스템 구성도와 서비스 흐름도, 개발 앱의 기능과 기술, 사용자 시나리오를 설명하여 인공와우를 이식받은 청소년 청각장애인이 언어치료 앱인 '발연기'를 통해 어떻게 언어치료를 받을 수 있을지에 대한 연구이다.

Effect of the STereoLithography File Structure on the Ear Shell Production for Hearing Aids According to DICOM Images (DICOM 영상에 의한 STL 파일 구조가 보청기 이어 쉘 제작에 미치는 영향)

  • Kim, Hyeong-Gyun
    • Journal of radiological science and technology
    • /
    • v.40 no.1
    • /
    • pp.121-126
    • /
    • 2017
  • A technique for producing the ear shell for a hearing aid using DICOM (Digital Imaging and Communication in Medicine) image and a 3D printing was studied. It is a new application method, and is an application technique that can improve the safety and infection of hearing aid users and can reduce the production time and process stages. In this study, the effects on the shape surface were examined before and after the printing of the ear shell using a 3D printer based on the values obtained from the raw data of the DICOM images at the volumes of 0.5 mm, 1.0 mm, and 2.0 mm, respectively. Before the printing, relative relationship was compared with respect to the STL (STereoLithography) file structure; and after the printing, the intervals of the layered structure of the ear shell shape surface were compared by magnifying them using a microscope. For the STL file structure, the numbers of triangular vertices, more than five intersecting points, and maximum intersecting points were large in the order of 0.5 mm, 1.0 mm, and 2.0 mm, respectively; and the triangular structure was densely distributed in the order of the bending, angle, and crest regions depending on the sinuosity of the external auditory meatus shape. As for the ear shell shape surface examined by the digital microscope, the interval of the layered structure was thick in the order of 2.0 mm, 1.0 mm, and 0.5 mm. For the STL surface structure mentioned above, the intersecting STL triangular structure was denser as the sinuosity of the 3D ear shell shape became more irregular and the volume of the raw data decreased.