• Title/Summary/Keyword: Hearing Screening

Search Result 62, Processing Time 0.029 seconds

Current Status of Health Screening in Korea (한국의 건강검진 현황)

  • Jo, Han-Ik
    • Journal of Korea Association of Health Promotion
    • /
    • v.2 no.2
    • /
    • pp.215-230
    • /
    • 2004
  • Along with a development of medical technology, a variety of tests, such as laboratory tests, x-ray and endoscopies are being used in health screening tests. As the tests determine the quality of health screening, test items and methods should be carefully selected. This study was to get hold of the test items of major health screening programs in Korea. Most of the health screening programmes focused upon detection of risk factors and diagnosis of life-style related diseases(diabetes, hypertension, cardiovascular diseases, hypercholesterolemia, overweight, drinking, smoking, cerebrovascular diseases, osteoporosis) ,cancers(stomach, cervix, lung, breast, liver, colon, prostate, ovary, pancreas, thyroid, esophagus), infectious diseases (hepatitis, tuberculosis, sexually-transmitted diseases, parasites),chronic obstructive respiratory diseases, chronic renal diseases(bacteriuria, hematuria, proteinuria), anemia, glaucoma, hearing loss, Alzheimer disease, stress, early Psychiatric diseases. The health screening tests were basic physical examination, basic laboratory tests(CBC, urinalysis, liver function tests, lipid tests, glucose, HbAlc, uric acid, electrolytes, serological tests(HBsAg, HBs-Ab, HCV-Ab, HIV-Ab, VDRL) EKG, x-ray(chest PA, CT), endoscopy (gastroscopy, colonoscopy) , sonography(abdormen, thyroid, pelvis, breast) , cytology(cervix) ,bone density, tumor markers(NMP22, alpha-FP, CEA, CA-19-9, CA12S, PSA) and eye tests. Advanced technologies, like CT, PET, MIRI, MIRI/Angio, molecular testings) were widely usedin hospital health screening programmes. In summary, a variety of were utilized by stages or programmes, however a few subjects. tests were utilized in health screening in Korea. Those tests according to sex and age in most of health screening program used tests to excess disregarding health screening subject.

  • PDF

Remote Patient Monitoring System for Diagnostic Pure-tone Audiometry (순음 청력검사를 위한 원격진단 모니터링 시스템)

  • Lee, Kang-Ho;Kwon, Yeong-Eun;Kwon, Ohwon
    • Journal of Sensor Science and Technology
    • /
    • v.28 no.5
    • /
    • pp.289-293
    • /
    • 2019
  • This paper presents a remote patient monitoring system for diagnostic pure-tone audiometry. A pure-tone audiometer was developed for basic hearing screening; its performance was evaluated according to international standards in terms of linearity, accuracy, and total harmonic distortion. Pure-tone audiometry has a maximum hearing level of 104.9 dB HL that is comparable with other commercial products. The audiometer shows satisfactory linearity with a deviation of ${\pm}0.4dB$, an accuracy of ${\pm}0.025%$, and a total harmonic distortion (THD) of 0.21%. The remote patient monitoring systems include remote control devices based on wide area network (WAN) connections and an audiometer connected in series. Through experimentation, we successfully performed real-time diagnostic communication without delay in transferring audiometric data. This system is expected to supply domestic equipment in the audiometric market and to improve the quality of life of patients in non-clinical environments.

국내 주요 기관의 건강진단 검사 종목

  • Jo, Han-Ik;Kim, Sang-In
    • Journal of Korea Association of Health Promotion
    • /
    • v.2 no.1
    • /
    • pp.9-25
    • /
    • 2004
  • Along with a development of medical technology, a variety of tests, such as laboratory tests, x-ray and endoscopies are being used in health screening tests. As the tests determine the quality of health screening, test items of major health screening program in Korea. Most, of the health screening programmes focused upon detection of risk factors and diagnosis of life-style related diseases(diabetes, hypertension, cardiovascular diseases, hypercholesterolemia, overweight, drinking, smoking, cerebrovascular diseases, osteoporosis), cancers(stomach, cervix, lung, breast, liver, colon, prostate, ovary, pancreas, thyroid, esophagus), infections diseases(hepatitis, tuberculosis, sexually-transmitted diseases, parasites), chronic obstructive respiratory diseases, chronic renal diseases(bacteriuria, hematuria, proteinuria), anemia, glaucoma, hearing loss, Alzheimer disease, stress and earlypsychiatric diseases. The health screening tests were basic physical examination, basic laboratory tests( CBC, urinalysis, liver function tests, lipid tests, glucose, HbA1c, uric acid, electrolytes, serological tests(HBsAg, HBs-Ab, HCV-Ab, HIV-Ab, VDRL) EKG, x-ray(chest PA, CT) endoscopy(gastroscopy, colonoscopy), sonography (abdomen, thyroid, pelvis, breast), cytology(cervix), bone density, tumor markers(NMP22, alpha-FP, CEA, CA-19-9, CA125, PSA and eye tests. Advanced technologies, like CT, PET, MRI, MRI/Angio, molecular testing were widly used in hospital based health screening programmes. In summary, a variety of tests were untilized in health screening in Korea. Those tests were utilized by stages or according to sex and age in most of health screening programmes, however a few programs used tests excessvely disregarding health screening subjects.

  • PDF

Automated Audiometry: A Review of the Implementation and Evaluation Methods

  • Shojaeemend, Hassan;Ayatollahi, Haleh
    • Healthcare Informatics Research
    • /
    • v.24 no.4
    • /
    • pp.263-275
    • /
    • 2018
  • Objectives: Automated audiometry provides an opportunity to do audiometry when there is no direct access to a clinical audiologist. This approach will help to use hearing services and resources efficiently. The purpose of this study was to review studies related to automated audiometry by focusing on the implementation of an audiometer, the use of transducers and evaluation methods. Methods: This review study was conducted in 2017. The papers related to the design and implementation of automated audiometry were searched in the following databases: Science Direct, Web of Science, PubMed, and Scopus. The time frame for the papers was between January 1, 2010 and August 31, 2017. Initially, 143 papers were found, and after screening, the number of papers was reduced to 16. Results: The findings showed that the implementation methods were categorized into the use of software (7 papers), hardware (3 papers) and smartphones/tablets (6 papers). The used transducers were a variety of earphones and bone vibrators. Different evaluation methods were used to evaluate the accuracy and the reliability of the diagnoses. However, in most studies, no significant difference was found between automated and traditional audiometry. Conclusions: It seems that automated audiometry produces the same results compared with traditional audiometry. However, the main advantages of this method; namely, saving costs and increased accessibility to hearing services, can lead to a faster diagnosis of hearing impairment, especially in poor areas.

A Study on Diagnostic Criteria of Noise-Induced Hearing Loss among Workers in an Iron Foundry (철강공장 근로자를 대상으로 살펴본 소음성 난청 진단기준에 관한 조사)

  • Kim, Ji-Yong;Lim, Hyun-Sul;Cheong, Hae-Kwan;Moon, Ok-Ryun
    • Journal of Preventive Medicine and Public Health
    • /
    • v.26 no.3 s.43
    • /
    • pp.371-386
    • /
    • 1993
  • This study was carried out to evaluate diagnostic criteria of noise-induced hearing loss (NIHL) among-workers in an iron foundry. Of 1,093 workers under the observation of noise-specific health examination, 184 workers were selected by way of first and second screening audiometric examination. A questionnaire survey, otological examinations, Rinne test and audiometric test were performed and the results were as follows ; The degree of hearing impairment in the left ear was more severe than in the right ear (p<0.05). The difference between hearing threshold of the first and the second hearing test at 1,000 Hz was about 5 dB with a narrow range of deviations while the difference at 4,000 Hz was about -7 dB with a wide range. Of the total study workers, 84.8% were tested within 15 hours away from noise exposure, and the rest after 16 hours. This study has identified that mean hearing loss at 4,000 Hz showed a significant statistical difference among the two study groups while mean hearing loss by 4-divided classification did not. The same phenomena were observed between the group with and without tinnitus and between the group with and without difficulty in hearing (p<0.05). Among 184 workers, 10 workers (5.4%) diagnosed as NIHL by old diagnostic criteria in contrast to 150 workers diagnosed as NIHL by the new diagnostic criteria. There was a significant difference between the two groups in the average hearing loss at 4,000 Hz and 4-divided classification (p<0.01), but there were no significant differences in age, the duration of employment, blood pressure and the duration wearing the personal hearing protector (p>0.05). If we apply Early Loss Index (ELI) method, some workers in younger age group diagnosed as NIHL by the new diagnostic criteria were fallen into within the normal range. In the mean time older age group show reverse results in contrast to the above finding. It is too early to confirm the value of the usage of the new diagnostic criteria in hearing examination. Further study is called for to verify the value of this criteria.

  • PDF

A Study about the Factors Affecting Hearing loss in Adolescent's use of Personal Cassette Players(PCPs) (휴대용 카세트 사용 청소년의 청력관련 요인)

  • Lim, Kyung-Hee;Park, Kyung-Min;Park, Myung-Hwa
    • Research in Community and Public Health Nursing
    • /
    • v.12 no.1
    • /
    • pp.125-141
    • /
    • 2001
  • The purpose of this study was to investigate the factors affecting hearing loss in adolescent's use of PCPs, and to give the basic data for adolescent's hearing conservation program development and prevention education against their hearing loss. This study was a descriptive research about three factors affecting hearing loss; the knowledge and attitude about noise, the perception of hearing loss and the hearing threshold. The subjects of this study were 383 students in two general high schools and two vocational high schools in Teagu. They have been using PCPs but with no current or past ear disease. This study was carried out from Sep. 1. 2000 to Oct. 24, 2000. The instrument used for the knowledge and attitude about noise was a questionnaire developed by Rhee. Kyung Yong and Yi. Kwan Hyung(1996). The instrument used for the perception of hearing loss was a Smith Hearing Screening Questionnaire. A Belton Model 112 Audiometer. air-conduction hearing test instrument. was used for the hearing threshold. Data was analysed by a SPSS/Win 10.0 program with frequency. percentage, t-test. ANOVA and pearson correlation. The results of this study were as follows; 1. The average of concern about hearing scored the highest $3.66{\pm}0.70$. The average of perceived susceptibility scored $2.64{\pm}0.85$ and the average of knowledge about noise scored $2.13{\pm}0.56$. The average of total knowledge and attitude about noise scored $2.82{\pm}0.46$. The average of discomfort of hearing loss($2.51{\pm}0.81$) scored higher than that fear of hearing loss($1.35{\pm}0.53$). The average of total perception of hearing loss scored $1.93{\pm}0.59$. The hearing threshold of the subjects scored the highest at 500Hz(Lt. $23.21{\pm}6.62$, Rt. $23.39{\pm}7.02$) and scored higher in order of 1000Hz, 2000Hz, 4000Hz and 8000Hz. 2. The knowledge and attitude about noise and the perception of hearing loss were both affected only by one important characteristic, which was general and vocational high schools. The knowledge and attitude about noise raked (t=5.258, p=0.000), and perception of hearing loss raked(t=2.241. p=0.026). However. several other important characteristics also impacted significantly on the knowledge and attitudes about noise. They included grade (t = 1. 987. p=0.048), father's education(F=2.745. p=0.043), marks(F=3.157, p=0.044), drinking(t=2.307, p=0.022) and smoking(t=2.587, p=0.010). The left hearing threshold differed significantly by sex at 1000Hz(t=5.175, p<0.001) and 8000Hz (t=3.334, p<0.01). According to general and vocational high schools (p<0.001), at 500Hz (t=-5.056), 1000Hz (t=-5.253), 2000Hz (t=-4.905), 4000Hz (t=-4.704) and 8000Hz (t=-5.204) significant differences were also shown. Marks were significant at 1000Hz (F=3.824, p<0.05) and drinking was found to be significant at 500Hz(t=2.203, p<0.05). The right hearing threshold differed significantly by sex at l000Hz(t=5.557. p<0.001). 4000Hz(t=2.234. p<0.05) and 8000Hz (t=2.730. p<0.01). According to general and vocational high schools(p<0.001) at 500Hz (t=-4.730), 1000Hz(t=-6.271). 2000Hz (t=-4.573). 4000Hz(t=-3.554) and 8000Hz (t=-3.405) significant differences were also shown. Grades impacted at 500Hz(t=2.201. p<0.05) and 4000Hz(t=2.511. p<0.05), while marks were significant at l000Hz(F=4.1l5. p<0.05) and drinking was significant at 500Hz(t=2.333. p<0.05). 3. The left hearing threshold in accordance with use of PCPs differed significantly at 2000Hz(F=2.996. p=0.03l) according to volume level and at 8000Hz(F=2.197. p=0.022) according to duration${\times}$hours per day. The right hearing threshold differed significantly at l000Hz(F=3.075. p=0.028) according to volume level and at 8000Hz(F=2.925. p=0.034) according to duration. 4. The knowledge and attitudes about noise showed a light positive correlation with the perception of hearing loss. A positive correlation was shown. as stated previously in all Hz, between the left hearing threshold and the right hearing threshold, especially the highest correlation at 2000Hz(r=0.761. p=0.000). This study has shown that the factors related to adolescent's use of PCPs are important as they impact significantly an adolescent's hearing. These results then indicate that in future, when designing a hearing conservation program and prevention education this data should be considered.

  • PDF

Algorithm of an automated auditory brainstem response neonatal hearing screening method (신생아를 대상으로한 청성뇌간유발반응의 자동 판독 알고리즘)

  • Jung, Won-Hyuk;Hong, Hyun-Ki;Kim, Sung-Woo;Kim, Jin-Tae;Park, Joong-Hoon;Kim, Deok-Won
    • Proceedings of the IEEK Conference
    • /
    • 2006.06a
    • /
    • pp.825-826
    • /
    • 2006
  • In this paper, we propose an algorithm that applies Rolle's theorem to automatically detect and label peak III and V of the normal, suprathreshold auditory brainstem response (ABR). ABR waveform were recorded from 55 normal-hearing ears at screening levels varying from 30 to 60 dBnHL. For each ABR waveform, the peak-finding algorithm proceeded in fourth steps: (1) Select maximum and minimum values of the target ABR waveform, (2) divide this range into n equal parts, (3) effective candidate peaks in the ABR waveform are identified using Rolle's theorem (4) peak III and V are identified from these candidate peaks based on their latency and morphology. As a result, proposed auto dectection method showed high correlation and accuracy with manual detection method performed by clinician. By using proposed algorithm, clinician can detect and label peak III and V faster and more efficient than manual detection method.

  • PDF

Incidence of hearing loss and importance of risk factors in the neonatal intensive care unit (신생아 중환자실에서 난청의 발생빈도 및 위험요소의 중요성)

  • Kong, Seung Hyun;Kang, Jang Hee;Hwang, Kwang Su;Kim, Joong Pyo;Lee, Hyeon Jung;Choi, Hyeon;Mok, Ji Sun;Kim, Jung Young
    • Clinical and Experimental Pediatrics
    • /
    • v.49 no.8
    • /
    • pp.845-850
    • /
    • 2006
  • Purpose : To assess the incidence of neonatal hearing loss in a neonatal intensive care unit and the relative importance of risk factors for hearing imparement in a neonatal intensive care unit which the Joint Committee on Infant Hearing(JCIH) had recommended. Methods : One thousand, two hundred and one newborns admitted to the Good Moonhwa Intensive Care Unit from May 2003 to December 2005 were assesed using the automated auditory brainstem response(AABR). The screening was performed on those aged more than 36 weeks and weighing more than 2,200 g. We divided the infants into two groups, 'pass' and 'refer'. The 'refer' group were retested one month later, and if classified as 'refer' during the retest, were referred to a hearing impairment clinic. Results : From the 1,201 neonates, 1,187(98.8 percent) passed the test and 14(1.2 percent) failed. 293(24.4 percent) of the 1,201 neonates had a risk factor for hearing impairment; 282(96.2 percent) passed the test and 11(3.8 percent) failed. The group with risk factors were shown to have a higher incidence of hearing loss(P<0.001). The neonates in the refer group were shown to have a higher incidence of ototoxic drugs(P<0.001), low birth weight(<1,500 g)(P<0.001) and craniofacial anomalies(P=0.007). On the other hand, there were no statistical differences between the pass and refer groups in congenital infection, hyperbilirubinemia, bacterial meningitis, low Apgar scores, prolonged mechanical ventilation and syndromes known to include hearing loss. Conclusion : In order to identify hearing-impaired infants within an appropriate period, neonatal hearing screening tests and identification of the risk factors for neonatal hearing loss are important.

Neonatal hearing screening in a neonatal intensive care unit using distortion product otoacoustic emissions (변조 이음향방사(DPOAE)를 이용한 고위험군 신생아 청각선별검사)

  • Kim, Do Young;Kim, Sung Shin;Kim, Chang Hwi;Kim, Shi Chan
    • Clinical and Experimental Pediatrics
    • /
    • v.49 no.5
    • /
    • pp.507-512
    • /
    • 2006
  • Purpose : Early detection and intervention of hearing impairment is believed to improve speech and language development and behavior of children. The aim of this preliminary study was to determine the prevalence of hearing impairments, and to identify the association of risk factors relating to refer response in high risk neonates who were screened using distortion product otoacoustic emissions (DPOAE). Methods : The subjects included 871 neonates who were admitted to the neonatal intensive care unit of the Pediatric Department in Soonchunhyang University Bucheon Hospital from May, 2001 to December, 2004. They were screened using DPOAE. Based on DPOAE, we divided the neonates in two groups : 'Pass' and 'Refer'. The differences in risk factors between the pass group and the refer group were analyzed. Results : The incidence of the refer group was 12.1 percent(106 out of 871). The bilateral refer rate was 5.4 percent(47 out of 871). And the unilateral refer rate was 6.7 percent(59 out of 871). Gender, birth place, family history of hearing loss, small/large for gestational age, obstetrical factor, hyperbilirubinemia and use of gentamicin were not statistically related to the refer rate. Statistically related to refer rate were birth weight, resuscitated neonates, Apgar score, craniofacial anomaly, mechanical ventilator application, sepsis, using of vancomycin(P<0.05). The prevalence of hearing impairment (${\geq}60dB$) in this study was 2 percent(18 out of 871). Conclusion : This study showed a higher prevalence of hearing impairment in high-risk neonates. Thus neonatal hearing screening should be carried out in high-risk neonates.

Morbidity Pattern of Residents in Urban Poor Area by Health Screening (도시 영세지역 주민의 건강진단 결과)

  • Kim, Chang-Yoon;SaKong, Jun;Kim, Seok-Beom;Kang, Pock-Soo;Chung, Jong-Hak
    • Journal of Yeungnam Medical Science
    • /
    • v.8 no.2
    • /
    • pp.150-157
    • /
    • 1991
  • The purpose of the this study was to assess the morbidity pattern of urban residents in the poor area by health screening for the community diagnosis. The items of health screening were history taking and physical examination by medical doctor and hearing test, check blood pressure, test for hematocrit, liver function(sGOT, sGPT), urine sugar and protein, and chest X-ray. The examinee in health screening were 437 persons and they occupied 16.9% of total residents in the poor area. Male examinee were 129 persons(9.9% of total residents) and female examinee were 308 persons(23.9% of total residents). Age group of above sixty years old, 42.0% of total residents in the poor area were participated, but only 5.9% were participated in age group of 10 to 19 years old. Among the 437 examinee, 191 persons(43.7%) had one or more abnormal findings in health screening. In male 38.7% had abnormal findings, and some what lower than that of female(45.8%). Age group of above sixty years had most high rate of abnormal findings(69.8%), in contrast to age group of 10 to 19 years old (10.9%). Diseases of the digestive system was the most common and which occupies 23.7% of total abnormal findings. And diseases of the circulatory system occupied 19.7%. Low hematocrit(14.6% of total participants of 437 persons) occupies the most common abnormal findings for screening test(hematocrit, blood pressure, hearing test, sGOT/sGPT, urine protein and urine sugar, chest X-ray) and high blood pressure(10.1%) occupied second, third; hearing impairment (5.5%), fourth ; abnormal liver function (4.1%), fifth ; sugar in urine (2.3%), sixth ; protein in urine(1.4%) and lastly abnormal chest X-ray (0.9%). The positive rate of abnormal findings in health screening was very high compared with morbidity rate by health interview. It is supposed that some portion of this high rate is by selection bias in examinee in health screening specially high participating rate in older age, and the other portion is due to the low socioecomic status and bad environment of the residents of the poor area. These findings will be good information for the research and development of health care system in the urban poor area.

  • PDF