• 제목/요약/키워드: Healthcare Technology

검색결과 1,476건 처리시간 0.025초

A Study on Users' Resistance toward ERP in the Pre-adoption Context (ERP 도입 전 구성원의 저항)

  • Park, Jae-Sung;Cho, Yong-Soo;Koh, Joon
    • Asia pacific journal of information systems
    • /
    • 제19권4호
    • /
    • pp.77-100
    • /
    • 2009
  • Information Systems (IS) is an essential tool for any organizations. The last decade has seen an increasing body of knowledge on IS usage. Yet, IS often fails because of its misuse or non-use. In general, decisions regarding the selection of a system, which involve the evaluation of many IS vendors and an enormous initial investment, are made not through the consensus of employees but through the top-down decision making by top managers. In situations where the selected system does not satisfy the needs of the employees, the forced use of the selected IS will only result in their resistance to it. Many organizations have been either integrating dispersed legacy systems such as archipelago or adopting a new ERP (Enterprise Resource Planning) system to enhance employee efficiency. This study examines user resistance prior to the adoption of the selected IS or ERP system. As such, this study identifies the importance of managing organizational resistance that may appear in the pre-adoption context of an integrated IS or ERP system, explores key factors influencing user resistance, and investigates how prior experience with other integrated IS or ERP systems may change the relationship between the affecting factors and user resistance. This study focuses on organizational members' resistance and the affecting factors in the pre-adoption context of an integrated IS or ERP system rather than in the context of an ERP adoption itself or ERP post-adoption. Based on prior literature, this study proposes a research model that considers six key variables, including perceived benefit, system complexity, fitness with existing tasks, attitude toward change, the psychological reactance trait, and perceived IT competence. They are considered as independent variables affecting user resistance toward an integrated IS or ERP system. This study also introduces the concept of prior experience (i.e., whether a user has prior experience with an integrated IS or ERP system) as a moderating variable to examine the impact of perceived benefit and attitude toward change in user resistance. As such, we propose eight hypotheses with respect to the model. For the empirical validation of the hypotheses, we developed relevant instruments for each research variable based on prior literature and surveyed 95 professional researchers and the administrative staff of the Korea Photonics Technology Institute (KOPTI). We examined the organizational characteristics of KOPTI, the reasons behind their adoption of an ERP system, process changes caused by the introduction of the system, and employees' resistance/attitude toward the system at the time of the introduction. The results of the multiple regression analysis suggest that, among the six variables, perceived benefit, complexity, attitude toward change, and the psychological reactance trait significantly influence user resistance. These results further suggest that top management should manage the psychological states of their employees in order to minimize their resistance to the forced IS, even in the new system pre-adoption context. In addition, the moderating variable-prior experience was found to change the strength of the relationship between attitude toward change and system resistance. That is, the effect of attitude toward change in user resistance was significantly stronger in those with prior experience than those with no prior experience. This result implies that those with prior experience should be identified and provided with some type of attitude training or change management programs to minimize their resistance to the adoption of a system. This study contributes to the IS field by providing practical implications for IS practitioners. This study identifies system resistance stimuli of users, focusing on the pre-adoption context in a forced ERP system environment. We have empirically validated the proposed research model by examining several significant factors affecting user resistance against the adoption of an ERP system. In particular, we find a clear and significant role of the moderating variable, prior ERP usage experience, in the relationship between the affecting factors and user resistance. The results of the study suggest the importance of appropriately managing the factors that affect user resistance in organizations that plan to introduce a new ERP system or integrate legacy systems. Moreover, this study offers to practitioners several specific strategies (in particular, the categorization of users by their prior usage experience) for alleviating the resistant behaviors of users in the process of the ERP adoption before a system becomes available to them. Despite the valuable contributions of this study, there are also some limitations which will be discussed in this paper to make the study more complete and consistent.

How to Implement Quality Pediatric Palliative Care Services in South Korea: Lessons from Other Countries (한국 소아청소년 완화의료의 발전 방안 제언: 국외 제공체계의 시사점을 중심으로)

  • Kim, Cho Hee;Kim, Min Sun;Shin, Hee Young;Song, In Gyu;Moon, Yi Ji
    • Journal of Hospice and Palliative Care
    • /
    • 제22권3호
    • /
    • pp.105-116
    • /
    • 2019
  • Purpose: Pediatric palliative care (PPC) is emphasized as standard care for children with life-limiting conditions to improve the quality of life. In Korea, a government-funded pilot program was launched only in July 2018. Given that, this study examined various PPC delivery models in other countries to refine the PPC model in Korea. Methods: Target countries were selected based on the level of PPC provided there: the United Kingdom, the United States, Japan, and Singapore. Relevant literature, websites, and consultations from specialists were analyzed by the integrative review method. Literature search was conducted in PubMed, Google, and Google Scholar, focusing publications since 1990, and on-site visits were conducted to ensure reliability. Analysis was performed on each country's process to develop its PPC scheme, policy, funding model, target population, delivery system, and quality assurance. Results: In the United Kingdom, community-based free-standing facilities work closely with primary care and exchange advice and referrals with specialized PPC consult teams of children's hospitals. In the United States, hospital-based specialized PPC consult teams set up networks with hospice agencies and home healthcare agencies and provide PPC by designating care coordinators. In Japan, palliative care is provided through several services such as palliative care for cancer patients, home care for technology-dependent patients, other support services for children with disabilities and/or chronic conditions. In Singapore, a home-based PPC association plays a pivotal role in providing PPC by taking advantage of geographic accessibility and cooperating with tertiary hospitals. Conclusion: It is warranted to identify unmet needs and establish an appropriate PPD model to provide need-based individualized care and optimize PPC in South Korea.

Analysis of Patient Effective Dose in PET/CT; Using CT Dosimetry Programs (CT 선량 측정 프로그램을 이용한 PET/CT 검사 환자의 예측 유효 선량의 분석)

  • Kim, Jung-Sun;Jung, Woo-Young;Park, Seung-Yong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • 제14권2호
    • /
    • pp.77-82
    • /
    • 2010
  • Purpose: As PET/CT come into wide use, it caused increasing of expose in clinical use. Therefore, Korea Food and Drug Administration issued Patient DRL (Diagnostic Reference Level) in CT scan. In this study, to build the basis of patient dose reduction, we analyzed effective dose in transmission scan with CT scan. Materials and Methods: From February, 2010 to March 180 patients (age: $55{\pm}16$, weight: $61.0{\pm}10.4$ kg) who examined $^{18}F$-FDG PET/CT in Asan Medical Center. Biograph Truepoint 40 (SIEMENS, GERMANY), Biograph Sensation 16 (SIEMENS, GERMANY) and Discovery STe8 (GE healthcare, USA) were used in this study. Per each male and female average of 30 patients doses were analyzed by one. Automatic exposure control system for controlling the dose can affect the largest by a patient's body weight less than 50 kg, 50-60 kg less, 60 kg more than the average of the three groups were divided doses. We compared that measured value of CT-expo v1.7 and ImPACT v1.0. The relationship between body weight and the effective dose were analyzed. Results: When using CT-Expo V1.7, effective dose with BIO40, BIO16 and DSTe8 respectably were $6.46{\pm}1.18$ mSv, $9.36{\pm}1.96 $mSv and $9.36{\pm}1.96$ mSv for 30 male patients respectably $6.29{\pm}0.97$ mSv, $10.02{\pm}2.42$ mSv and $9.05{\pm}2.27$ mSv for 30 female patients respectably. When using ImPACT v1.0, effective dose with BIO40, BIO16 and DSTe8 respectably were $6.54{\pm}1.21$ mSv, $8.36{\pm}1.69$ mSv and $9.74{\pm}2.55$Sv for 30 male patients respectably $5.87{\pm}1.09$ mSv, $8.43{\pm}1.89$ mSv and $9.19{\pm}2.29$ mSv for female patients respectably. When divided three groups which were under 50 kg, 50~60 kg and over 60 kg respectably were 6.27 mSv, 7.67 mSv and 9.33 mSv respectably using CT-Expo V1.7, 5.62 mSv, 7.22 mSv and 8.91 mSv respectably using ImPACT v1.0. Weight and the effective dose coefficient analysis showed a very strong positive correlation(r=743, r=0.693). Conclusion: Using such a dose evaluation programs, easier to predict and evaluate the effective dose possible without performing phantom study and such dose evaluation programs could be used to collect basic data for CT dose management.

  • PDF

The Evaluation of SUV Variations According to the Errors of Entering Parameters in the PET-CT Examinations (PET/CT 검사에서 매개변수 입력오류에 따른 표준섭취계수 평가)

  • Kim, Jia;Hong, Gun Chul;Lee, Hyeok;Choi, Seong Wook
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • 제18권1호
    • /
    • pp.43-48
    • /
    • 2014
  • Purpose: In the PET/CT images, The SUV (standardized uptake value) enables the quantitative assessment according to the biological changes of organs as the index of distinction whether lesion is malignant or not. Therefore, It is too important to enter parameters correctly that affect to the SUV. The purpose of this study is to evaluate an allowable error range of SUV as measuring the difference of results according to input errors of Activity, Weight, uptake Time among the parameters. Materials and Methods: Three inserts, Hot, Teflon and Air, were situated in the 1994 NEMA Phantom. Phantom was filled with 27.3 MBq/mL of 18F-FDG. The ratio of hotspot area activity to background area activity was regulated as 4:1. After scanning, Image was re-reconstructed after incurring input errors in Activity, Weight, uptake Time parameters as ${\pm}5%$, 10%, 15%, 30%, 50% from original data. ROIs (region of interests) were set one in the each insert areas and four in the background areas. $SUV_{mean}$ and percentage differences were calculated and compared in each areas. Results: $SUV_{mean}$ of Hot. Teflon, Air and BKG (Background) areas of original images were 4.5, 0.02. 0.1 and 1.0. The min and max value of $SUV_{mean}$ according to change of Activity error were 3.0 and 9.0 in Hot, 0.01 and 0.04 in Teflon, 0.1 and 0.3 in Air, 0.6 and 2.0 in BKG areas. And percentage differences were equally from -33% to 100%. In case of Weight error showed $SUV_{mean}$ as 2.2 and 6.7 in Hot, 0.01 and 0.03 in Tefron, 0.09 and 0.28 in Air, 0.5 and 1.5 in BKG areas. And percentage differences were equally from -50% to 50% except Teflon area's percentage deference that was from -50% to 52%. In case of uptake Time error showed $SUV_{mean}$ as 3.8 and 5.3 in Hot, 0.01 and 0.02 in Teflon, 0.1 and 0.2 in Air, 0.8 and 1.2 in BKG areas. And percentage differences were equally from 17% to -14% in Hot and BKG areas. Teflon area's percentage difference was from -50% to 52% and Air area's one was from -12% to 20%. Conclusion: As shown in the results, It was applied within ${\pm}5%$ of Activity and Weight errors if the allowable error range was configured within 5%. So, The calibration of dose calibrator and weighing machine has to conduct within ${\pm}5%$ error range because they can affect to Activity and Weight rates. In case of Time error, it showed separate error ranges according to the type of inserts. It showed within 5% error when Hot and BKG areas error were within ${\pm}15%$. So we have to consider each time errors if we use more than two clocks included scanner's one during the examinations.

  • PDF

A Comparative Study of the Standard Uptake Values of the PET Reconstruction Methods; Using Contrast Enhanced CT and Non Contrast Enhanced CT (PET/CT 영상에서 조영제를 사용하지 않은 CT와 조영제를 사용한 CT를 이용한 감쇠보정에 따른 표준화섭취계수의 비교)

  • Lee, Seung-Jae;Park, Hoon-Hee;Ahn, Sha-Ron;Oh, Shin-Hyun;NamKoong, Heuk;Lim, Han-Sang;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • 제12권3호
    • /
    • pp.235-240
    • /
    • 2008
  • Purpose: At the beginning of PET/CT, Computed Tomography was mainly used only for Attenuation Correction (AC), but as the performance of the CT have been increase, it could give improved diagnostic information with Contrast Media. But it was controversial that Contrast Media could affect AC on PET/CT scan. Some submitted thesis' show that Contrast Media could overestimate when it is for AC data processing. On the contrary, the opinion that Contrast Media could be possible to affect the alteration of SUV because of the overestimated AC. But it does not have a definite effect on the diagnosis. Thus, the affection of Contrast Media on AC was investigated in this study. Materials and Methods: Patient inclusion criteria required a history of a malignancy and performance of an integrated PET/CT scan and contrast- enhanced CT scan within a 1-day period. Thirty oncologic patients who had PET/CT scan from December 2007 to June 2008 underwent staging evaluation and met these criteria. All patients fasted for at least 6 hr before the IV injection of approximately 5.6 MBq/kg (0.15 mCi/kg) of $^{18}F$-FDG and were scanned about 60 min after injection. All patients had a whole body PET/CT performed without IV contrast media followed by a contrast-enhanced CT on the Discovery STe PET/CT scanner. CT data were used for AC and PET images came out after AC. The ROIs drew and measured SUV. A paired t-test of these results was performed to assess the significance of the difference between the SUV obtained from the two attenuation corrected PET images. Results: The mean and maximum Standardized Uptake Values (SUV) for different regions averaged over all Patients. Comparing before using Contrast Media and after using, Most of ROIs have the increased SUV when it did Contrast Enhanced CT compare to Non-Contrast enhanced CT. All regions have increased SUV and also their p value was under 0.05 except the mean SUV of the Heart region. Conclusion: In this regard, the effect on SUV measurements that occurs when a contrast-enhanced CT is used for attenuation correction could have significant clinical ramifications. But some submitted thesis insisted that the percentage change in SUV that can determine or modify clinical management of oncology patients is small. Because there was not much difference that could be discovered by interpreter. But obviously the numerical change was occurred and on the stage finding primary region, small change would be base line, such as the region of liver which has greater change than the other regions needs more attention.

  • PDF

Evaluation of Proper Image Acquisition Time by Change of Infusion dose in PET/CT (PET/CT 검사에서 주입선량의 변화에 따른 적정한 영상획득시간의 평가)

  • Kim, Chang Hyeon;Lee, Hyun Kuk;Song, Chi Ok;Lee, Gi Heun
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • 제18권2호
    • /
    • pp.22-27
    • /
    • 2014
  • Purpose There is the recent PET/CT scan in tendency that use low dose to reduce patient's exposure along with development of equipments. We diminished $^{18}F$-FDG dose of patient to reduce patient's exposure after setting up GE Discovery 690 PET/CT scanner (GE Healthcare, Milwaukee, USA) establishment at this hospital in 2011. Accordingly, We evaluate acquisition time per proper bed by change of infusion dose to maintain quality of image of PET/CT scanner. Materials and Methods We inserted Air, Teflon, hot cylinder in NEMA NU2-1994 phantom and maintained radioactivity concentration based on the ratio 4:1 of hot cylinder and back ground activity and increased hot cylinder's concentration to 3, 4.3, 5.5, 6.7 MBq/kg, after acquisition image as increase acquisition time per bed to 30 seconds, 1 minute, 1 minute 30 seconds, 2 minute, 2 minutes 30 seconds, 3 minutes, 3 minutes 30 seconds, 4 minutes, 4 minutes 30 seconds, 5 minutes, 5 minutes 30 seconds, 10 minutes, 20 minutes, and 30 minutes, ROI was set up on hot cylinder and back radioactivity region. We computated standard deviation of Signal to Noise Ratio (SNR) and BKG (Background), compared with hot cylinder's concentration and change by acquisition time per bed, after measured Standard Uptake Value maximum ($SUV_{max}$). Also, we compared each standard deviation of $SUV_{max}$, SNR, BKG following in change of inspection waiting time (15minutes and 1 hour) by using 4.3 MBq phantom. Results The radioactive concentration per unit mass was increased to 3, 4.3, 5.5, 6.7 MBqs. And when we increased time/bed of each concentration from 1 minute 30 seconds to 30 minutes, we found that the $SUV_{max}$ of hot cylinder acquisition time per bed changed seriously according to each radioactive concentration in up to 18.3 to at least 7.3 from 30 seconds to 2 minutes. On the other side, that displayed changelessly at least 5.6 in up to 8 from 2 minutes 30 seconds to 30 minutes. SNR by radioactive change per unit mass was fixed to up to 0.49 in at least 0.41 in 3 MBqs and accroding as acquisition time per bed increased, rose to up to 0.59, 0.54 in each at least 0.23, 0.39 in 4.3 MBqs and in 5.5 MBqs. It was high to up to 0.59 from 30 seconds in radioactivity concentration 6.7 MBqs, but kept fixed from 0.43 to 0.53. Standard deviation of BKG (Background) was low from 0.38 to 0.06 in 3 MBqs and from 2 minutes 30 seconds after, low from 0.38 to 0 in 4.3 MBqs and 5.5 MBqs from 1 minute 30 seconds after, low from 0.33 to 0.05 in 6.7 MBqs at all section from 30 seconds to 30 minutes. In result that was changed the inspection waiting time to 15 minutes and 1 hour by 4.3 MBq phantoms, $SUV_{max}$ represented each other fixed values from 2 minutes 30 seconds of acquisition time per bed and SNR shown similar values from 1 minute 30 seconds. Conclusion As shown in the above, when we increased radioactive concentration per unit mass by 3, 4.3, 5.5, 6.7 MBqs, the values of $SUV_{max}$ and SNR was kept changelessly each other more than 2 minutes 30 seconds of acquisition time per bed. In the same way, in the change of inspection waiting time (15 minutes and 1 hour), we could find that the values of $SUV_{max}$ and SNR was kept changelessly each other more than 2 minutes 30 seconds of acquisition time per bed. In the result of this NEMA NU2-1994 phantom experiment, we found that the minimum acquisition time per bed was 2 minutes 30 seconds for evaluating values of fixed $SUV_{max}$ and SNR even in change of inserting radioactive concentration. However, this acquisition time can be different according to features and qualities of equipment.

  • PDF