• Title/Summary/Keyword: Health assessment

Search Result 6,085, Processing Time 0.028 seconds

Chinese relationship between animation and best pole - Focused on the aesthetic principles of the Cultural Revolution period (중국 애니메이션과 모범극의 상관관계 연구 - 문화대혁명 시기의 미학 원칙을 중심으로)

  • Kong, De Wei
    • Cartoon and Animation Studies
    • /
    • s.39
    • /
    • pp.215-231
    • /
    • 2015
  • The Cultural Revolution in the history of Chinese animation hinder the development of the initial animation, and after a negative assessment instrument provided the cause is to become sluggish growth of the Chinese animation. So this time animation are things that are the subject of academic research studies or analysis has been depreciating almost uniformly without evaluation. However, of all the cultural and artistic creation it is developing in its own specific historical conditions and has the aesthetic results. This paper puts the primary purpose is to hold in consideration the aesthetic principles that led to cultural and artistic creativity and objective perspective the achievements the Chinese animation of the time period of the Cultural Revolution. Cultural Revolution is avoided to the previous period in accordance with the socialist ideology of Mao Ze-dong(毛澤東) sikindaneun highlight the culture of the proletariat and placed our goal to create a new class culture. Therefore, cultural and artistic creation of this period is often inconsistent with this part of our aesthetic principles generally accepted character has a non- elitist and anti properties. Best drama is a creative one hand as a model to implement the principles of aesthetics, art and culture Cultural Revolution period kkophimyeo reference for understanding the aesthetic principles that animated the Chinese Cultural Revolution period of orientation. This paper has San Tu Chu(三突出), Hong Guang Liang(紅光亮), and Gao Da Quan(高大全) at the time of the Cultural Revolution aesthetic principles are reflected in how the concrete work, the Cultural Revolution when the animation is how to accommodate these aesthetic principles and placed emphasis on comparative studies on best pole and correlation of the Cultural Revolution when the Chinese animation to ensure that adaptation in own way. First, after analyzing whether the aesthetic principles of focusing on the similarities of the best pole time of the Cultural Revolution and China, and how to implement animation in the works, these aesthetic principles according to the analysis of positive and negative influence on the creation of Chinese animation It was described as neutral. The detailed analysis and comparative study courses were trying to access in two significant aspects of the characters and scenes directing. In terms of character animation of the Cultural Revolution in China when a young boy or girl, emphasis should emphasize the health tinged with red lips and cheek blush to highlight the desired Gong Nong Bing(工農兵) shape as the main character and smooth texture and sophisticated highlights the glittering feeling to the touch, it was confirmed focused hayeoteum to implement the principle of 'Hong Guang Liang', highlighting the brilliant colors with a clean, bright colors. Highlighting a number of protagoniste compared to the antagonist in the animated scene of the Cultural Revolution a few times in terms of production and, among a number of protagoniste also emphasizes the outstanding hero figure, "yet three outstanding heroes heroic figures also emphasize the leading figures among the the director of the extrusion step-by-step approach "('San Tu Chu')was used. In addition, the hero figure is generally high and low angle by directing a large and perfect aesthetic appearance was to faithfully implement the principle of 'high-charged'('Gao Da Quan').

Risk Analysis of Arsenic in Rice Using by HPLC-ICP-MS (HPLC-ICP-MS를 이용한 쌀의 비소 위해도 평가)

  • An, Jae-Min;Park, Dae-Han;Hwang, Hyang-Ran;Chang, Soon-Young;Kwon, Mi-Jung;Kim, In-Sook;Kim, Ik-Ro;Lee, Hye-Min;Lim, Hyun-Ji;Park, Jae-Ok;Lee, Gwang-Hee
    • Korean Journal of Environmental Agriculture
    • /
    • v.37 no.4
    • /
    • pp.291-301
    • /
    • 2018
  • BACKGROUND: Rice is one of the main sources for inorganic arsenic among the consumed crops in the world population's diet. Arsenic is classified into Group 1 as it is carcinogenic for humans, according to the IARC. This study was carried out to assess dietary exposure risk of inorganic arsenic in husked rice and polished rice to the Korean population health. METHODS AND RESULTS: Total arsenic was determined using microwave device and ICP-MS. Inorganic arsenic was determined by ICP-MS coupled with HPLC system. The HPLC-ICP-MS analysis was optimized based on the limit of detection, limit of quantitation, and recovery ratio to be $0.73-1.24{\mu}g/kg$, $2.41-4.09{\mu}g/kg$, and 96.5-98.9%, respectively. The inorganic arsenic concentrations of daily exposure (included in body weight) were $4.97{\times}10^{-3}$ (${\geq}20$ years old) $-1.36{\times}10^{-2}$ (${\leq}2$ years old) ${\mu}g/kg\;b.w./day$ (PTWI 0.23-0.63%) by the husked rice, and $1.39{\times}10^{-1}$ (${\geq}20$ years old) $-3.21{\times}10^{-1}$ (${\leq}2$ years old) ${\mu}g/kg\;b.w./day$ (PTWI 6.47-15.00%) by the polished rice. CONCLUSION: The levels of overall exposure to total and inorganic arsenic by the husked and polished rice were far lower than the recommended levels of The Joint FAO/WHO Expert Committee on Food Additives (JECFA), indicating of little possibility of risk.

Analysis of HBeAg and HBV DNA Detection in Hepatitis B Patients Treated with Antiviral Therapy (항 바이러스 치료중인 B형 간염환자에서 HBeAg 및 HBV DNA 검출에 관한 분석)

  • Cheon, Jun Hong;Chae, Hong Ju;Park, Mi Sun;Lim, Soo Yeon;Yoo, Seon Hee;Lee, Sun Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.23 no.1
    • /
    • pp.35-39
    • /
    • 2019
  • Purpose Hepatitis B virus (hepatitis B virus, HBV) infection is a worldwide major public health problem and it is known as a major cause of chronic hepatitis, liver cirrhosis and liver cancer. And serologic tests of hepatitis B virus is essential for diagnosing and treating these diseases. In addition, with the development of molecular diagnostics, the detection of HBV DNA in serum diagnoses HBV infection and is recognized as an important indicator for the antiviral agent treatment response assessment. We performed HBeAg assay using Immunoradiometric assay (IRMA) and Chemiluminescent Microparticle Immunoassay (CMIA) in hepatitis B patients treated with antiviral agents. The detection rate of HBV DNA in serum was measured and compared by RT-PCR (Real Time - Polymerase Chain Reaction) method Materials and Methods HBeAg serum examination and HBV DNA quantification test were conducted on 270 hepatitis B patients undergoing anti-virus treatment after diagnosis of hepatitis B virus infection. Two serologic tests (IRMA, CMIA) with different detection principles were applied for the HBeAg serum test. Serum HBV DNA was quantitatively measured by real-time polymerase chain reaction (RT-PCR) using the Abbott m2000 System. Results The detection rate of HBeAg was 24.1% (65/270) for IRMA and 82.2% (222/270) for CMIA. Detection rate of serum HBV DNA by real-time RT-PCR is 29.3% (79/270). The measured amount of serum HBV DNA concentration is $4.8{\times}10^7{\pm}1.9{\times}10^8IU/mL$($mean{\pm}SD$). The minimum value is 16IU/mL, the maximum value is $1.0{\times}10^9IU/mL$, and the reference value for quantitative detection limit is 15IU/mL. The detection rates and concentrations of HBV DNA by group according to the results of HBeAg serological (IRMA, CMIA)tests were as follows. 1) Group I (IRMA negative, CMIA positive, N = 169), HBV DNA detection rate of 17.7% (30/169), $6.8{\times}10^5{\pm}1.9{\times}10^6IU/mL$ 2) Group II (IRMA positive, CMIA positive, N = 53), HBV DNA detection rate 62.3% (33/53), $1.1{\times}10^8{\pm}2.8{\times}10^8IU/mL$ 3) Group III (IRMA negative, CMIA negative, N = 36), HBV DNA detection rate 36.1% (13/36), $3.0{\times}10^5{\pm}1.1{\times}10^6IU/mL$ 4) Group IV(IRMA positive, CMIA negative, N = 12), HBV DNA detection rate 25% (3/12), $1.3{\times}10^3{\pm}1.1{\times}10^3IU/mL$ Conclusion HBeAg detection rate according to the serological test showed a large difference. This difference is considered for a number of reasons such as characteristics of the Ab used for assay kit and epitope, HBV of genotype. Detection rate and the concentration of the group-specific HBV DNA classified serologic results confirmed the high detection rate and the concentration in Group II (IRMA-positive, CMIA positive, N = 53).

A Study on the Dietary Quality Assessment among the Elderly in Jeonju Area (전주지역 노인의 식사의 질 평가에 관한 연구)

  • 김인숙;유현희;서은숙;서은아;이형자
    • Journal of Nutrition and Health
    • /
    • v.35 no.3
    • /
    • pp.352-367
    • /
    • 2002
  • In order to assess the quality of dietary intake among the elderly, a survey was conducted during Jucy-August, 1999, of 230 subjects who were 65 years or older and who were living in Jeonju City. Results of the analysis of the data are as follows : Regarding Dietery Variety Score (DVS), the average number of food items consumed per person was significantly higher for males (19.6) than for females (17.7). The intake of plant food was higher than animal food for both sexes the proportion of plant versus animal foods consumed by fresh weight was 85 : 15 for males and 89 : 11 for females. Diet Diversity Score (DDS) is determined by how many from five food groups (cereal, meat, dairy, vegetable and fruit) consumed per day while Korean Diet Diversity Score (KDDS) is determined by how many from five different food groups (cereal, meat, vegetable, dairy and oil) consumed per day. The subjects'average DDS and KDDS were 4.0 and 3.5 for males, and 3.7 and 3.2 for females, respectively. Overall, the distribution of DDS was lower than that of KDDS. The average Meal Balance Score (MBS : Apply the KDDS at breakfast, lunch and dinner) was 9.1 for malts and 8.1 for females. Average daily caloric intake for males and females was 1,740 kcal and 1,433 kcal, which was 84.0% and 80.9% of the RDA, respectively. Average daily protein intake for males and females, at 67 g and 49 g (100.7% and 88.3% of the RDA), respectively, was satisfactory. However, intakes of calcium and vitamin A were below 75% of the RDA (calcium : 62.7% for males and 55.3% for females ; vitamin A : 60.7% for males and 53.9% far females). The average proportional contribution of protein/fat/carbohydrate (PFC) to total calorie intake was 15.8 : 15.7 : 68.5 for males and 13.8 : 13.2 : 73.0 for females. Distribution of energy for each meal (breakfast : lunch : afternoon snack : dinner : night snack) was 29.2 : 32.4 : 5.0 : 31.2 : 2.2 among males and 30.5 : 33.5 : 4.5 : 28.6 : 2.91 among females. The Index of Nutritional Quality (INQ) was above 1 for protein, phosphorus, iron, vitamin B$_1$, niacin, and vitamin C. However, the INQ of calcium and vitamin A were below 1 among both males and females, and the INQ of vitamin B$_2$was below l among females. The Nutrient Adequacy Ratio (NAR = nutrient intake %RDA) was below 1 for all nutrients, and the NAR of vitamin A were the lowest among 9 nutrients (protein, calcium, phosphorus, iron, vitamin A, vitamin B$_1$, vitamin B$_2$, niacin, vitamin C) for both males and females, with values of 0.52 and 0.42, respectively. The second and third lowest NAR values were for calcium(males: 0.68: females: 0.54) and vitamin B$_2$(males: 0.77: females: 0.67). Values of Mean Adequacy Ratio (MAR = sum of 9 NARs/9) for males (0.82) were higher than for females (0.73). These results indicate that the intakes of calcium and vitamin A were severely inadequate. The results of a stepwise multiple regression analysis, where the DVS or MAR were the dependent variables and the DDS, KDDS, and MBS were independent variables, indicated that DDS is a more useful variable than KDDS in determining the quality of meals of the elderly.

Diagnostic Reference Levels for Patient Radiation Doses in Pelvis and Lumbar spine Radiography in Korea (우리나라의 골반 및 요추 엑스선검사에서의 환자선량 권고량)

  • Lee, Kwang-Yong;Lee, Byung-Young;Lee, Jung-Eun;Lee, Hyun-Koo;Jung, Seung-Hwan;Kim, Byung-Woo;Kim, Hyeog-Ju;Kim, Dong-Sup
    • Journal of radiological science and technology
    • /
    • v.32 no.4
    • /
    • pp.401-410
    • /
    • 2009
  • Purpose : Pelvis and lumbar spine radiography, among various types of diagnostic radiography, include gonads of the human body and give patients high radiation dose. Nevertheless, diagnostic reference levels for patient radiation dose in pelvis and lumbar spine radiography has not yet been established in Korea. Therefore, the radiation dose that patients receive from pelvis and lumbar radiography is measured and the diagnostic reference level on patient radiation dose for the optimization of radiation protection of patients in pelvis and lumbar spine radiography was established. Methods : The conditions and diagnostic imaging information acquired during the time of the postero-anterior view of the pelvis and the postero-anterior and lateral view of the lumbar spine at 125 medical institutions throughout Korea are collected for analysis and the entrance surface dose received by patients is measured using a glass dosimeter. The diagnostic reference levels for patient radiation dose in pelvis and lumbar spine radiography to be recommended to the medical institutes is arranged by establishing the dose from the patient radiation dose that corresponds to the 3rd quartile values as the appropriate diagnostic reference level for patient radiation dose. Results : According to the results of the assessment of diagnostic imaging information acquired from pelvis and lumbar spine radiography and the measurement of patient entrance surface dose taken at the 125 medical institutes throughout Korea, the tube voltage ranged between 60~97 kVp, with the average use being 75 kVp, and the tube current ranged between 8~123 mAs, with the average use being 30 mAs. In the posteroanterior and lateral views of lumbar spine radiography, the tube voltage of each view ranged between 65~100 kVp (average use: 78 kVp) and 70~109 kVp (average use: 87 kVp), respectively, and the tube current of each view ranged between 10~100 mAs(average use: 35 mAs) and between 8.9~300 mAs(average use: 64 mAs), respectively. The measurements of entrance surface dose that patients receive during the pelvis and lumbar spine radiography show the following results: in the posteroanterior view of pelvis radiography, the minimum value is 0.59 mGy, the maximum value is 12.69 mGy and the average value is 2.88 mGy with the 1st quartile value being 1.91 mGy, the median being 0.59 mGy, and the 3rd quartile value being 3.43 mGy. Also, in the posteroanterior view of lumbar spine radiography, the minimum value is 0.64 mGy, the maximum value is 23.84 mGy, and the average value is 3.68 mGy with the 1st quartile value being 2.41 mGy, the median being 3.40 mGy, and the 3rd quartile value being 4.08 mGy. In the lateral view of lumbar spine radiography, the minimum value is 1.90 mGy, the maximum value is 45.42 mGy, and the average value is 10.08 mGy with the 1st quartile value being 6.03 mGy, the median being 9.09 mGy and the 3rd quartile value being 12.65 mGy. Conclusions : The diagnostic reference levels for patient radiation dose to be recommended to the medical institutes in Korea is 3.42 mGy for the posteroanterior view of pelvis radiography, 4.08 mGy for the posteroanterior view of lumbar spine radiography, and 12.65 mGy for the lateral view of lumbar spine radiography. Such values are all lower than the values recommended by 6 international organizations including World Health Organization, where the recommended values are 10 mGy for the posteroanterior view of pelvis radiography, 10 mGy for the posteroanterior view of lumbar spine radiography and 30 mGy for the lateral view of lumbar spine radiography.

  • PDF