• 제목/요약/키워드: Health Platform

검색결과 492건 처리시간 0.021초

국내 전철 및 가전제품을 대상으로 한 전자장 수준 실태조사 (A survey on the EMF Levels of Study and Electric Appliances in Korea)

  • 장성기;조용성;이석조;유승화;정경미;임준호
    • 한국산업보건학회지
    • /
    • 제15권1호
    • /
    • pp.71-81
    • /
    • 2005
  • The purposes of this study was to collect, analyze, and describe the MF exposure levels from subways in Korea and to measure and evaluate the MF levels generated from electric appliances used at general homes. The target subway lines were Seoul Metropolitan Line 1 to Line 8, Bundang Line, Incheon Line, Daegu Line, Gwangju Line, and Busan Line 1 and Line 2. We measured at each station in those subway lines and, all the train types (pantograph-equipped, motor-equipped, and common), and platform types(facing and isolating) were investigated by the distance(80, 200, 400 cm) from the train on 19 targeted subway lines using 3 magnetic field measuring devices (EMDEXII, Enertech Co.) during the survey from January till October, 2004. On the other hand, the levels of the 60Hz magnetic fields generated from 14 items of home electric appliances such as electric blankets, hair dryers, electric razors, etc. were measured at 10 general homes using 5 EMDEXII meters with a sampling interval of 1.5 second by the distance(surface, 30, 50, 100, 300cm ) from the target electric appliances. The survey results in the whole subway lines examined in this study were as follows; Seoul Metropolitan Line 4 using AC(alternating current) power source showed the highest mean value of $2.85{\mu}T$, followed by Seoul Metropolitan Line 1 running between Seoul and Incheon using AC($2.78{\mu}T$), Seoul Metropolitan Line 1 between Seoul and Uijongbu using AC($2.73{\mu}T$), Bundang Line using AC($1.79{\mu}T$), Seoul Metropolitan Line 1 connected from Yongsan using AC($1.67{\mu}T$), Seoul Metropolitan Line 1 between Seoul and Suwon using AC($0.79{\mu}T$), and so on. In general, the intensity of the magnetic field in the subway systems in Korea was significantly higher when using AC($2.14{\pm}0.91{\mu}T$) than when using DC($0.29{\pm}0.44{\mu}T$) power source. Among the home electric appliances examined, microwave ovens showed the highest mean value of $7.69{\mu}T$, followed by hair dryers($6.47{\mu}T$), vacuum cleaners($5.27{\mu}T$), televisions ($2.26{\mu}T$), electric blankets($1.38{\mu}T$), personal computers ($0.81{\mu}T$), and so on. Two items of electric appliances showed the excess value of $0.2{\mu}T$ at the distance of 30cm in the MF exposure level; electric razors $1.58{\pm}2.13{\mu}T$ and vacuum cleaners $0.48{\pm}0.44{\mu}T$. As a whole, this study showed a tendency that the shift of the MF levels according to the increase of distance from the electric appliances was lower than those of the results surveyed in UK and USA. As a result, this study is expected to suggest meaningful data for the future study in exposure assessment of magnetic fields and for the establishment of guidelines for subways and electric appliances in Korea. More detailed and large scaled exposure assessment studies should be performed continuously to get the various and useful information on health risk assessment of MFs in Korea.

건강한 한국인 분변으로부터 분리된 Ruminococcus sp. KGMB03662 균주의 유전체 염기서열 초안 (Draft genome sequence of Ruminococcus sp. KGMB03662 isolated from healthy Korean human feces)

  • 한국일;강세원;엄미경;김지선;이근철;서민국;김한솔;박승환;이주혁;박잠언;오병섭;유승우;유승엽;최승현;이동호;윤혁;김병용;이제희;이정숙
    • 미생물학회지
    • /
    • 제55권3호
    • /
    • pp.274-277
    • /
    • 2019
  • 본 연구에서는 건강한 한국인 분변으로부터 Ruminococcus sp. KGMB03662 균주를 분리하고 유전체서열을 PacBio Sequel 플랫폼을 사용하여 분석하였다. 염색체의 크기는 2,707,502 bp로 G + C 구성 비율은 43.09%, 총 유전자수는 2,484개, 단백질 코딩 유전자는 2,367개, rRNA는 14개 및 tRNA는 53개로 구성되었다. 본 유전체로부터 가수분해효소, 지방산생합성 및 대사와 항생제생합성 및 내성 관련 유전자를 확인하였다. 이러한 유전체의 분석은 KGMB03662 균주가 사람의 건강 및 질병에 관여할 것으로 여겨진다.