• Title/Summary/Keyword: Health Platform

Search Result 497, Processing Time 0.027 seconds

A Study on the Applicability of Social Security Platform to Smart City (사회보장플랫폼과 스마트시티에의 적용가능성에 관한 연구)

  • Jang, Bong-Seok
    • Journal of the Korea Convergence Society
    • /
    • v.11 no.11
    • /
    • pp.321-335
    • /
    • 2020
  • Given that with the development of the 4th industry, interest and desire for smart cities are gradually increasing and related technologies are developed as a way to strengthen urban competitiveness by utilizing big data, information and communication technology, IoT, M2M, and AI, the purpose of this study is to find out how to achieve this goal on the premise of the idea of smart well fair city. In other words, the purpose is to devise a smart well-fair city in the care area, such as health care, medical care, and welfare, and see if it is feasible. With this recognition, the paper aimed to review the concept and scope of smart city, the discussions that have been made so far and the issues or limitations on its connection to social security and social welfare, and based on it, come up with the concept of welfare city. As a method of realizing the smart welfare city, the paper reviewed characteristics and features of a social security platform as well as the applicability of smart city, especially care services. Furthermore, the paper developed discussions on the standardization of the city in terms of political and institutional improvements, utilization of personal information and public data as well as ways of institutional improvement centering on social security information system. This paper highlights the importance of implementing the digitally based community care and smart welfare city that our society is seeking to achieve. With regard to the social security platform based on behavioral design and the 7 principles(6W1H method), the present paper has the limitation of dealing only with smart cities in the fields of healthcare, medicine, and welfare. Therefore, further studies are needed to investigate the effects of smart cities in other fields and to consider the application and utilization of technologies in various aspects and the corresponding impact on our society. It is expected that this paper will suggest the future course and vision not only for smart cities but also for the social security and welfare system and thereby make some contribution to improving the quality of people's lives through the requisite adjustments made in each relevant field.

The Effects of Fatigue Induced by Submaximal Treadmill Exercise on Body Sway (최대하 트레드밀 운동에 의한 피로가 신체 동요에 미치는 영향)

  • Lee, Mi-Sun;Yi, Chung-Hwi;Cho, Sang-Hyun;Kwon, Oh-Yun
    • Physical Therapy Korea
    • /
    • v.7 no.2
    • /
    • pp.35-54
    • /
    • 2000
  • The purposes of this study were to assess variation of body sway prior to and after submaximal treadmill exercise; to determine the time course of the effects of a fatiguing performed on a treadmill on body sway; and to compare position sense prior to and after exercise in order to assess any variance in proprioception caused by submaximal treadmill exercise. The subjects were twenty-four healthy men in their twenties. They stood barefoot on the Kinesthetic Ability Training Balance Platform to measure body sway. Control trials were performed with eyes alternately open and closed. In the eyes open condition, they were asked to look at a target placed at eye level 1 m in front them. A total of 10 trials, each lasting 20 seconds, were performed. After this series of trials, position sense was measured. Subjects then exercised on the treadmill until 85% of each person's maximal heart rate was reached. The first series of postural sway measurements began immediately after this exercise. The second identical series of postural sway trials was performed at approximately 10 minutes after exercise. The third series was performed approximately 20 minutes after exercise. This allowed approximately 5 minutes of rest between each experimental series. Position sense was measured at approximately 15 and 25 minutes after exercise. The results were as follows: 1) There was a significant increase in body sway after submaximal treadmill exercise compared to pre-exercise values under both visual conditions (p<.05). 2) After submaximal treadmill exercise, under the eyes open condition, the mean value of body sway was significantly increased after both the first and second series (p<.05). Under the eyes closed condition, the mean value of body sway increased significantly after the first series but decreased significantly after the third series (p<.05). 3) Position sense, measured repeatedly after submaximal treadmill exercise, did not change significantly with respect to pre-exercise values (p>.05). These results suggest that fatigue induced by submaximal treadmill exercise produced an increase in body sway in young healthy subjects with or without visual input, but the increase appeared to be lasting less than 15 minutes. No significant change in position sense suggested that proprioception was unaffected by submaximal treadmill exercise-induced fatigue.

  • PDF

Development of a Metamodel-Based Healthcare Service System using OSGi Component Platform (OSGi 컴포넌트 플랫폼을 이용한 메타모델 기반의 건강관리 서비스 시스템 개발)

  • Kim, Tae-Woong;Kim, Hee-Cheol
    • Journal of Korea Multimedia Society
    • /
    • v.14 no.1
    • /
    • pp.121-132
    • /
    • 2011
  • A healthcare system is a type of medical information system that performs early detection and prevention in diseases by checking one's health condition periodically. Such a healthcare system is based on the signal obtained from the body. However, the developed existing system represents certain differences in the storage and description of vital signs according to medicare devices and the evaluation method of the system. It brings some disadvantages, such as lacks in the interoperability between systems, increases in the development cost of systems, and absence of a unified system. Thus, this study develops a healthcare system based on a meta model. For establishing this objective, this study describes and stores vital sign data based on the standard meta model of HL7 and applies OCL, which is a mathematical specification language, for defining wellness indexes and extracting data in order to evaluate health risk appraisals in health. In addition, this study implements components based on OSGi and assemble them in order to easily extend various devices and systems. By describing vital data based on the meta model, it represents some advantages that it makes possible to ensure the interoperability between systems and introduce the standardization of the evaluation method of health conditions through defining the wellness index using OCL. Also, it provides dear specifications.

A Previous Study on Customized Visualization Expression of Personal Health Record (개인건강기록의 맞춤형 시각화 표현을 위한 선행연구)

  • Yang, Junggi;Lee, Yong-Jun;Kim, Hae-Na;Lee, YoungHo
    • Journal of the Korea Society of Computer and Information
    • /
    • v.19 no.11
    • /
    • pp.115-126
    • /
    • 2014
  • In order to improvement of the perceptive of health state and the motivation, this study suggests the ways and design forms which provide PHR information customizing individual attributes as well as guidelines through a decision support system and services which integrate medical information visualization. Expression methods using the color, form, position in order to visualization based on images improved performance of information awareness by changing radar chart from existing information which provide only numerical figure. The methods providing a graphic figure which seems like beads of blood which shows the result of blood tests would also arise patient's attention. They gives the patient's information which is able to compare their health status and normal status and visualizes the records as a human figure in order to perceiving their status as well. The visualization showing the position of human body figures marks in inspection elements located in position of relevant organs. The method also uses icons represent examination results so they improve attention of the results and shorten recognize times.

Liberalization of Telemedicine in Germany (독일 원격의료 합법화와 법개정 논의)

  • Kim, SooJeong
    • The Korean Society of Law and Medicine
    • /
    • v.21 no.2
    • /
    • pp.3-33
    • /
    • 2020
  • Until recently the German and the South Korean medical associations reacted cautiously to the introduction of telemedicine between doctor and patient which is exclusively on the platform conducted. But the General Assembly of German Physicians voted to lift the ban on remote treatment with the amendment to Section 7 (4) MBO-Ä(Medical Association's Professional Code of Conduct) in 2018 and the situation has been fundamentally changed in Germany. From then until now 16 of 17 rural medical associations have changed their professional code to allow telemedicine. In addition the legislature started to prepare the basis for the introduction of the electronic health card (eGK) and the telematics infrastructure. So far, various laws such as Medicinal Products Act, Drug Advertisement Act and Social Code have been changed to support legalization of telemedicine and digitalization of health care. Unlike in Germany, the social circumstances such as excessive centralization of the big hospitals in Seoul and the resulting concern of small medical practices for profitability are the main obstacles to the introduction of telemedicine. However the German approach how to legalise the telemedicine and to prepare for legal and technical infrastructure is also interesting in South Korea. The discussions for and against the changes in the law and the telematics infrastructure attempted by the German government for several years indicate that not only lifting the ban on remote treatment, but also harmonization of all the related legal system could guarantee successful implementation of telemedicine.

Compensation of Light Scattering Method for Real-Time Monitoring of Particulate Matters in Subway Stations (지하역사 내 미세먼지 실시간 모니터링을 위한 광산란법 보정)

  • Kim, Seo-Jin;Kang, Ho-Seong;Son, Youn-Suk;Yoon, Sang-Lyeor;Kim, Jo-Chun;Kim, Gyu-Sik;Kim, In-Won
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.26 no.5
    • /
    • pp.533-542
    • /
    • 2010
  • The $PM_{10}$ concentrations in the underground should be monitored for the health of commuters on the underground subway system. Seoul Metro and Seoul Metropolitan Rapid Transit Corporation are measuring several air pollutants regularly. As for the measurement of $PM_{10}$ concentrations, instruments based on $\beta$-ray absorption method and gravimetric methods are being used. But the instruments using gravimetric method give us 20-hour-average data and the $\beta$-ray instruments can measure the $PM_{10}$ concentration every one hour. In order to keep the $PM_{10}$ concentrations under a healthy condition, the air quality of the underground platform and tunnels should be monitored and controlled continuously. The $PM_{10}$ instruments using light scattering method can measure the $PM_{10}$ concentrations every less than one minute. However, the reliability of the instruments using light scattering method is still not proved. The purpose of this work is to study the reliability of the instruments using light scattering method to measure the $PM_{10}$ concentrations continuously in the underground platforms. One instrument using $\beta$-ray absorption method and two different instruments using light scattering method (LSM1, LSM2) were placed at the platform of the Jegi station of Seoul metro line Number 1 for 10 days. The correlation between the $\beta$-ray instrument and the LSM2 ($r^2$=0.732) was higher than that between the $\beta$-ray instrument and the LSM1 ($r^2$=0.393). Thus the LSM2 was chosen for further analysis. Three different regression analysis methods were tested: Linear regression analysis, Nonlinear regression analysis and Orthogonal regression analysis. When the instruments using light scattering method were used, the data measured these instruments have to be converted to actual $PM_{10}$ concentrations using some factors. With these analyses, the factors could be calculated successfully as linear and nonlinear forms with respect to the data. And the orthogonal regression analysis was performed better than the ordinary least squares method by 28.45% reduction of RMSE. These findings propose that the instruments using light scattering method light scattering method can be used to measure and control the $PM_{10}$ concentrations of the underground subway stations.

Air Quality Monitoring System Using NDIR-CO$_2$ Sensor for Underground Space based on Wireless Sensor Network (비분산적의선 CO$_2$센서를 이용한 무선 센서 네트워크 기반의 지하 공기질 모니터링 시스템)

  • Kwon, Jong-Won;Kim, Jo-Chun;Kim, Gyu-Sik;Kim, Hie-Sik
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.46 no.4
    • /
    • pp.28-38
    • /
    • 2009
  • In this study, a remote air quality monitoring system for underground spaces was developed by using NDIR-based CO$_2$ sensor. And the remote monitoring system based on wireless sensor networks was installed practically on the subway station platform. More than 6.5 million citizens commutate everyday by the Seoul subway transportation that is the most typical public transportation. They concern about air quality with increasing interest on public health or many workers in subway stations or underground shopping centers. Recently, the Korean Ministry of Environment has operated the air quality monitoring system in some subway stations for testing phase. However, it showed many defects which are large-scale, high-cost and maintenance of precision sensors imported from abroad. Therefore this research includes the reliability test and a theoretical study about the inexpensive commercialized CO$_2$ sensor for reliable measurement of air quality which changes rapidly by the surrounding environments. And then we develop the wireless sensor nodes and the gateway applied for remote air quality monitoring. In addition, web server program was realized to manage air quality in the subway platform. This result will be valuable for a basic research for air quality management in underground spaces for future study.

Effect of light touch on body sway during a stable posture with blocked visual information

  • Kim, Jong-Gun;Kim, Jin-Hong;Do, Kwang-Sun;Yim, Jongeun
    • Physical Therapy Rehabilitation Science
    • /
    • v.5 no.3
    • /
    • pp.138-142
    • /
    • 2016
  • Objective: The purpose of this study was to investigate how light touch with a finger affects balance ability when a posture is maintained in the condition of visual information blockage and to provide a fundamental material for developing balance ability in the process of rehabilitation treatment. Design: Cross-sectional study. Methods: The study subjects were 17 healthy men and women in their twenties and thirties who were studying at S University in Seoul. The system was comprised of an equilateral triangular force platform. Subjects were asked to step on the foot position of the force platform (Good Balance, Finland) barefooted for 30 seconds, with eyes closed, hands hanging down loosely, and feet comfortably apart. It was connected to a laptop by using Bluetooth technology. An experiment was conducted in the following three circumstances: 1) no-touch trial, 2) light touch to the back (T7 area), and 3) light touch to the middle finger of the left hand. Each subject was given a 10-minute break between consecutive measurements. The experimental circumstances were performed randomly. Anteroposterior sway (APSV), mediolateral sway velocity (MLSV), and velocity moment (VM) were measured. Results: The APSVs (mm/s) were $9.32{\pm}3.37$ and $5.45{\pm}2.98$; the MLSVs (mm/s), $6.39{\pm}3.35$ and $3.31{\pm}2.48$; and VM ($mm^2/s$), $17.13{\pm}11.75$ and $6.76{\pm}8.31$ in the first and second experimental circumstances, respectively. APSV, MLSV, and VM values were significantly improved with the 1) no-touch trial and 2) light touch to the back trail conditions compared with the 3) light touch to the middle finger of the left hand condition (p<0.05). Conclusions: This study revealed that the balance ability for maintaining a body posture was influenced more by light touch to the back (T7) than by light touch with the sensitive fingertip and body sway diminished after visual information was blocked.

Effects of Visual Information Blockage on Landing Strategy during Drop Landing (시각 정보의 차단이 드롭랜딩 시 착지 전략에 미치는 영향)

  • Koh, Young-Chul;Cho, Joon-Haeng;Moon, Gon-Sung;Lee, Hae-Dong;Lee, Sung-Cheol
    • Korean Journal of Applied Biomechanics
    • /
    • v.21 no.1
    • /
    • pp.31-38
    • /
    • 2011
  • This study aimed to determine the effects of the blockage of visual feedback on joint dynamics of the lower extremity. Fifteen healthy male subjects(age: $24.1{\pm}2.3\;yr$, height: $178.7{\pm}5.2\;cm$, weight: $73.6{\pm}6.6\;kg$) participated in this study. Each subject performed single-legged landing from a 45 cm-platform with the eyes open or closed. During the landing performance, three-dimensional kinematics of the lower extremity and ground reaction force(GRF) were recorded using a 8 infrared camera motion analysis system (Vicon MX-F20, Oxford Metric Ltd, Oxford, UK) with a force platform(ORG-6, AMTI, Watertown, MA). The results showed that at 50 ms prior to foot contact and at the time of foot contact, ankle plantar-flexion angle was smaller(p<.05) but the knee joint valgus and the hip flexion angles were greater with the eyes closed as compared to with the eyes open(p<.05). An increase in anterior GRF was observed during single-legged landing with the eyes closed as compared to with the eyes open(p<.05). Time to peak GRF in the medial, vertical and posterior directions occurred significantly earlier when the eyes were closed as compared to when the eyes were open(p<.05). Landing with the eyes closed resulted in a higher peak vertical loading rate(p<.05). In addition, the shock-absorbing power decreased at the ankle joint(p<.05) but increased at the hip joints when landing with the eyes closed(p<.05). When the eyes were closed, landing could be characterized by a less plantarflexed ankle joint and more flexed hip joint, with a faster time to peak GRF. These results imply that subjects are able to adapt the control of landing to different feedback conditions. Therefore, we suggest that training programs be introduced to reduce these injury risk factors.

Introduction of Hindfoot Coronal Alignment View (후족부 관상면 배열 영상에 대한 고안)

  • Moon, Il-Bong;Jeon, Ju-Seob;Yoon, Kang-Cheol;Choi, Nam-Kil;Kim, Seung-Kook
    • Journal of radiological science and technology
    • /
    • v.29 no.4
    • /
    • pp.225-228
    • /
    • 2006
  • Purpose: Accurate clinical evaluation of the alignment of the calcaneus relative to the tibia in the coronal plane is essential in the evaluation and treatment of hindfoot pathologic condition. Previously described standard anteroposterior, lateral, and oblique radiographic methods of the foot or ankle do not demonstrate alignment of the tibia relation to the calcaneus in the coronal plane. The purpose of this study was to introduce hindfoot coronal alignment view. Material : 1) Both feet were imaged simultaneously on an elevated, radiolucent foot stand equipment. 2) Both feet stood on a radiolucent platform with equal weight on both feet. 3) Both feet are located foot axis longitudinal perpendicular to the platform. 4) Silhouette tracing around both feet are made, and line is then drawn to bisect the silhouette of the second toe and the outline of the heel. 5) The x-ray beam is angled down approximately $15^{\circ} to $20^{\circ} Result : 1) This image described tibial axis and medial, lateral tuberosity of calcaneus. 2) Calcaneus do not rotated. 3) The view is showed by talotibial joint space. Conclusion: Although computed tomographic and magnetic resonance imaging techniques are capable of demonstrating coronal hindfoot alignment, they lack usefulness in most clinical situations because the foot is imaged in a non-weight bearing position. But hindfoot coronal alignment view is obtained for evaluating position changing of inversion, eversion of the hindfoot and varus, valgus deformity of calcaneus.

  • PDF