• Title/Summary/Keyword: Head phantom

Search Result 286, Processing Time 0.028 seconds

Absorbed Doses in Organs of the Head and Neck from Conventional Temporomandibular Joint Tomography (악관절 단층촬영시의 두경부 주요 기관의 흡수선량)

  • Cho Bong-Hae
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.29 no.2
    • /
    • pp.411-416
    • /
    • 1999
  • Purpose : This study was done to evaluate the absorbed doses in organs of the head and neck for the conventional temporomandibular joint tomography. Materials and Methods : Dosimetry was performed with 32 LiF thermoluminescent dosimeters, which were placed in a tissue-equivalent phantom when the temporomandibular joint was examined by both lateral and frontal temporomandibular joint tomography. Results : For lateral tomography, parotid gland and preauricular area towards tube showed relatively high absorbed dose of 1056.9 μGy and 519.9 μGy respectively. For frontal tomography, the two largest absorbed doses were 259.2 μGy in orbit towards tube and 212.0 μGy in lens towards tube. Conclusion : Conventional temporomandibular joint tomography showed relatively low absorbed doses on critical organs. Thus, responsible use of it may not be limited.

  • PDF

Analysis of SAR for body-mounted mobile phones (인체 착용형 무선 단말기에 대한 노출량 해석)

  • Park, Min-Young;Ko, Chea-Ok;Pack, Jeong-Ki
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2005.11a
    • /
    • pp.425-428
    • /
    • 2005
  • A variety of wireless devices are commercially available now. Most of studies, however, have been directed to the biological effects of mobile-phone EMF. In this study, dosimetric analysis for wireless devices of head-mounted display type and a wristwatch type were made to investigate possible biological effects of these devices. SAR (Specific Absorption Rate) distributions were calculated using FDTD (Finite Difference Time Domain) method, for adult human models such as standard Korean human model and VHP(Visible Human Project) model, as well as scaled models. Measurements were also performed for SAM phantom wearing a simplified prototype for a wireless device for validation of the simulation results. It has been found that children are more vulnerable to such exposure, and these devices could cause some biological effects for relatively lower power compared to conventional mobile pones.

  • PDF

A Comparative Study of SNR and Image According to the Aplication Coil in MRI Inspection (자기공명영상검사에서 Coil적용에 따른 SNR과 영상의 비교연구)

  • Park, Ye-won;Lim, Cheong-hwan
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2015.05a
    • /
    • pp.147-148
    • /
    • 2015
  • MRI검사 시 다양한 환자를 고려한 변화에 적절한 coil의 선택과 조건에 따른 SNR의 차이를 조사하여 우수한 SNR의 영상을 획득하고자 한다. MR영상 획득실험은 Bottle Phantom를 이용하여 Philips achieva 1.5T와 SIMENS 1.0T을 이용하여 sequence별, surface coil별로 MR영상을 획득하여 SNR를 구하였다. 주자장이 1.0T에서 가장 높은 SNR은 TSE와 FLAIR에서 knee coil, GE에서 head coil로 측정되었고, 주자장이 1.5에서 가장 높은 SNR은 TSE에서 head coil, FLAIR와 GE에서 knee coil로 측정되었다. 본 연구에서 획득한 결과를 중심으로 다양한 환자를 고려한 변화에 따른 적절한 coil의 선택과 조건에 따라 SNR의 차이를 조사하여 우수한 SNR의 영상을 제시하여야 한다.

  • PDF

Evaluation of Accuracy on Hitchcoke CT/angio localization system using QA head phantom (QA용 두부 팬톰을 이용한 Hitchcoke CT 및 혈관조영 정위적 시스템에 대한 정확도 평가)

  • 김성현;서태석;윤세철;손병철;김문찬;신경섭
    • Progress in Medical Physics
    • /
    • v.9 no.1
    • /
    • pp.1-9
    • /
    • 1998
  • In order to provide complementary image data, CT(computed tomography), MR(magnetic resonance) and angiography have been used in the field of Stereotactic Radiosurgery(SRS) and neurosurgery. The aim of this work is to develop 3-D stereotactic localization system in order to determine the precise shape, size and location of the lesion in the brain in the field of Stereotactic Radiosurgery(SRS) and neurosurgery using multi-image modality and multi purpose QA phantom. In order to obtain accurate position of a target, Hitchcoke stereotactic frame and CT/angiography localizers were rigidly attached to the phantom with nine targets dispersed in 3-D space. The algorithms to obtain a 3-D stereotactic coordinates of the target have been developed using the images of the geometrical phantom which were taken by CT/angiography. Positions of targets computed by our algorithms were compared to the absolute position assigned in the phantom. Outlines of targets on each CT image were superimposed each other on angiography images. A spatial mean distance errors were 1.02${\pm}$0.17mm for CT with a 512${\times}$512 matrix and 2mm slice thickness, 0.41${\pm}$0.05mm for angiogra- phy localization. The resulting accuracy in the target localization suggests that the developed system has enough Qualification for Stereotactic Radiosurgery (SRS).

  • PDF

Verification of Stereotactic Target Point Achieved by Acquisition of MR Image in Actual Treatment Position of Radiosurgery (정위적 방사선 수술시 치료위치에서의 정위적 표적점 확인을 통한 자기공명영상 획득의 정확도 연구)

  • 윤형근;신교철;김영식
    • Progress in Medical Physics
    • /
    • v.9 no.2
    • /
    • pp.89-94
    • /
    • 1998
  • To make practical application of the MR image for stereotactic radiosurgery, the target point-achieved by acquisition of MR image in stereotactic radiosurgery planning system must agree with the actual isocenter of irradiation in real treatment. And the amount of distortion of the MR image must be known to make a correction for the agreement. A radish containing abundant water content was chosen as a homogeneous phantom for the purpose of verification of the agreement in this experiment. A dosimetric film was firmly attached to the small specially fabricated acryl plate and needle puncture was made through the film just into the acryl plate and a drop of oil was dropped into the hole of the film. The acryl plate with film was inserted into the radish and the dorp of oil represented the target point in MR image. After the image acquisition by stereotatic radiosurgery planning system, we achieved stereotactic coordinate of the target point represented by the oil drop. And we proceeded to actual irradiation to the target point according to the procedure of stereotactic radiosurgery. After the irradiation, the film in the radish was developed and processed and the degree of coincidence between the center of the radiation distribution and the target point represented by the hole in the film was measured. The discrepancy between two points was under 0.5 mm. so we could confirm good coincidence in homogeneous phantom such as radish. On the other hand, authors tried to use our home-made device for estimation of distortion of MR image.

  • PDF

A absorbed and effective dose from the full-mouth periapical radiography using portable dental x-ray machine and panoramic radiography (ORIGINAL ARTICLE - 이동형 구내방사선촬영기로 촬영한 치근단 방사선촬영과 파노라마방사선촬영의 흡수선량과 유효선량 평가)

  • Han, Won-Jeong
    • The Journal of the Korean dental association
    • /
    • v.50 no.7
    • /
    • pp.420-430
    • /
    • 2012
  • Purpose: The purpose of this study was to measure the absorbed dose and to calculate the effective dose for full-mouth periapical radiography using the portable dental x-ray machine and panoramic radiography Material and Method: Thermoluminescent chips were placed at 25sites throughout the layers of the head and neck of a tissue-equivalent human skull phantom. The man phantom was exposed with the portable dental x-ray machine and panoramic unit. During full-mouth periapical radiography the exposure setting was 60 kVp, 2 mA and 0.15 ~ 0.25 seconds, while during panoramic radiography the selected exposure setting was 72 kVp, 8 mA and 18 seconds. Absorbed dose measurements were obtained and equivalent doses to individual organs were summed using ICRP 103 to calculate of effective dose. Result: In the full-mouth periapical radiography, the highest absorbed dose was recorded at the mandible body follow with submandibular glands and cheek. Using panoramic unit, the highest absorbed dose was parotid glands and the following was back of neck and submandibular glands. The effective dose in full-mouth periapical radiography using portable dental x-ray machine was 46 ${\mu}Sv$. In panoramic radiography, the effective dose was 38 ${\mu}pSv$. Conclusion: It was recommended to panoramic radiography for general check in the head and neck area because that the effect dose in the panoramic radiography was lower than the dose in the full-mouth periapical radiography using portable dental x-ray machine.

ORGAN DOSE, EFFECTIVE DOSE AND RISK ASSESSMENT FROM COMPUTED TOMOGRAPHY TO HEAD AND NECK REGION (두경부 전산화 단층촬영시의 주요 장기선량, 유효선량 및 위험도)

  • Kim Ae-Jj;Cho Bong-Hae;Nah Kyung-Soo
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.25 no.1
    • /
    • pp.27-38
    • /
    • 1995
  • The organ or tissue doses were determined with head and neck phantom measurement for multiple axial scans (36 slices), multiple coronal scans (13 slices), 3 types of single axial scans(orbit, maxillary sinus and mandibular canal) and single coronal scan (maxillary sinus). For each scan sequence 30 TLDs were placed in selected sites(16 internal sites and 14 external sites) in a tissue-equivalent phantom. The exposure was made at 120kVp, 500mAs with 5 mm slice width. The results were as follows : 1. In multiple axial scans, the greatest effective dose recorded was that delivered to the thyroid glands(2.77 mSv) and the least was that received by the skin(0.05 mSv). From these data, stochastic effects were 202.2x10/sup -6/ and 3.7×10/sup -6/, respectively. 2. In multiple coronal scans, the greatest effective dose recorded was that delivered to the salivary glands(0.58 mSv) and the least was that received by the skin(0.01 mSv). From these data, stochastic effects were 42.2×10/sup -6/ and 0.7×10/sup -6/, repectively. 3. Among single axial scans, the greatest effective dose recorded was that delivered to the salivary gland(0.38 mSv) in maxillary sinus scan. From this data, stochastic effect was 27.7×10/sup -6/. 4. In single coronal scan, the greatest effective dose recorded was that delivered to the salivary gland(0.01 mSv). From this data, stochastic effect was 1.0×10/sup -6/. 5. The equivalent dose measured that delivered to the lens of the eyes was 69.64 mSv in multiple axial scan, 39.32 mSv in multiple coronal scan and 36.77 mSv in single axial scan(orbit).

  • PDF

An Applicable Method of an Electromagnetic Wave Absorber for SAR Reduction in the Human Head Exposed to Electromagnetic Fields Radiated by a Cellular Phone (휴대폰 전자파에 노출된 두부내 SAR 저감을 위한 전자파 흡수체 적용 방법 연구)

  • 이윤경;백락준;홍진옥;육재림;윤현보
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.14 no.8
    • /
    • pp.884-890
    • /
    • 2003
  • In order to reduce the specific absorption rate(SAR) in a human head exposed to electromagnetic fields radiated by a cellular phone, we have analyzed an electromagnetic wave absorber attached to the handset. A manufactured electromagnetic wave absorber was composed of Mn - Zn, which had complex relative permittivity of 7.30-j0.05 and permeability of 2.20-i1.55. The SAR value from the electromagnetic wave absorber attachment was calculated by using the nonuniform finite difference time domain(FDTD) algorithm and measured by phantom model at 835 MHz. The SAR reduction due to the electromagnetic wave absorber are about 18 % at 835 MHz. The V.S.W.R and radiation pattern of antenna are good agreement with the normal antenna. The gain reduction due to the electromagnetic wave absorber are only 0.3 dB at 835 MHz. But the sensitivity of cellular phone generally improves about 1 dB.

A Study on Reducing of Entrance Surface Dose with the Eye in the Computed Radiography by Using High Kilo Voltage Peak Technique (컴퓨터 방사선영상에서 고 관전압 기법을 이용한 안구 입사표면선량 감소에 관한 연구)

  • Seoung, Youl-Hun;Rhim, Jea-Dong
    • Journal of the Korea Safety Management & Science
    • /
    • v.13 no.2
    • /
    • pp.91-96
    • /
    • 2011
  • The purpose of this study was to minimize of entrance surface dose (ESD) at the eye using high kVp technique in the computed radiography. We used REX-650R (Listem, Korea) general X-ray unit, and external detector with ESD dosimeter of Piranha 657 (RTI Electronics, Sweden). We used head of the whole body phantom. The total 64 images of X-ray anterior-posterior of skull were acquired using the film/screen (F/S) method and the digital of computed radiography method. The three radiology professor of more 10 years of clinical career evaluated a X-rays images in the same space by 5-point scale. The external detector was performed measurement of ESD of three times by same condition on the eye of the head phantom. The good image quality in the F/S method (90 kVp, 2.5 mAs) showed at the minimized ESD of 0.310 ${\pm}$ 0.001 mGy. the good image quality in the computed radiography method (90 kVp, 2.0 mAs) showed at the minimized ESD of 0.180 ${\pm}$ 0.002 mGy (P = 0.002). Finally the radiation dose could reduced about 50% in the computed radiography method more than the F/S method. In addition the eye entrance surface dose using high kVp technique with the computed radiography was reduced 92% more than conventional technique (F/S method).