• 제목/요약/키워드: Head fixation frame

검색결과 6건 처리시간 0.019초

Avoiding a Collision in Gamma Knife Radiosurgery : A Modified Mask Fixation Method

  • Hyeong Cheol Moon;Doheui Lee;Byung Jun Min;Young Gyu Kim;Yun-Sik Dho
    • Journal of Korean Neurosurgical Society
    • /
    • 제66권4호
    • /
    • pp.476-481
    • /
    • 2023
  • Objective : The latest version of the Leksell Gamma Knife IconTM allows for mask- and frame-based fixation. Although mask fixation provides fractionated treatment and immobilization using a noninvasive method, it is not free from collision. The authors investigated the collision problem with a modified mask fixation method. Methods : This study presents a case of two meningiomas in the frontal area, where a collision occurs in the occipital area. A modified mask fixation method was introduced to avoid the collision : first, the edges of the head cushion were cut off and polystyrene beads with a diameter of approximately 5 cm were removed. Next, the head cushion was sealed using a stapler. Finally, the head cushion was flattened in the adapter. We compared the shot coordinates, 3-dimensional (3D) error, clearance distance, and vertical depth of the head cushion between the initial and modified mask fixations. Results : When comparing the initial and modified mask fixations, the difference in the shot coordinates was +10.5 mm along the y-axis, the difference in the 3D error was approximately 18 mm, and the difference in clearance was -10.2 mm. The head cushion was approximately 8 mm deeper in the modified mask fixation. Conclusion : Based on these findings, we recommend a modified mask fixation method for gamma knife radiosurgery using ICON with a collision.

분할 정위방사선 치료 시스템 개발 연구 (Development of A Fractionated Stereotactic Radiotherapy System)

  • 이동한;지영훈;이동훈;조철구;김미숙;유형준;류성렬
    • 한국의학물리학회지:의학물리
    • /
    • 제13권1호
    • /
    • pp.9-14
    • /
    • 2002
  • 두부 프레임을 지지하는 방식으로 pedestal mounting system과 couch mounting system의 장점을 수용한, 새로운 형태의 분할 정위방사선 치료 시스템을 개발하였다. 두부 고정을 위한 프레임은 두랄루민으로 제작하였고, 카우치에 부착되게 하였다. 프레임 내에서 환자의 두부를 고정하기 위해 치아 고정장치와 3.2 mm 열프라스틱으로 전두부와 후두부에 마스크를 제작할 수 있다. 정위 좌표 구현을 위한 전산화 단층촬영 localizer는 각 병원에서 많이 사용하고 있는 Brown-Roberts-Walls(B.R.W) 시스템을 사용할 수 있게 하여, 개발된 시스템의 신뢰성을 높이고 제작 단가도 낮추고자 하였다. 프레임 mounting system은 pedestal mounting system을 수정, 보완한 형태로 개발하였다. 시스템은 카우치를 지지하는 바닥 면에 고정되어 카우치에 부착된 프레임과 결합할 수 있고, 시스템과 카우치의 잠금 장치를 푼 채 자유롭게 x, y축으로 유동할 수 있다. 프레임 mounting system의 중심축은 상, 하 방향으로 이동 가능한 포인터 형태로 제작하여, 치료기의 구동 정확성을 검증하는 정도 관리에 응용 가능하다. 개발된 시스템의 재현성과 정확도 검증을 위해 아크릴 팬텀과 포인터를 제작하였고, 전산화 단층촬영 영상에서 획득한 팬텀 내 목표점의 정위 좌표를 dial-gauge와 E.C.L 필름으로 검증하였다. 실험의 결과 x축 방향의 재현성 오차는 0.71$\pm$0.19 mm, y축 방향은 0.45$\pm$0.15 mm, z축 방향 재현성 오차는 0.63$\pm$0.18 mm로 나타났고, 최대 1.3 mm 이내의 우수한 재현성을 보였다. 연구 결과로 개발된 분할 정위방사선 치료 시스템은 재현성이 우수하고, 전체 중량이 가벼워 사용하기 쉽게 제작되었다. 특히 수정된 pedestal frame mounting system으로 설계되어 후두부 방사선 조사가 가능한 장점이 있다.

  • PDF

두경부암 환자의 양성자 치료 시 사용하는 자체 제작한 BoS Frame 고정장치의 선량학적 유용성 평가 (Dosimetric evaluation of using in-house BoS Frame Fixation Tool for the Head and Neck Cancer Patient)

  • 김광석;조광현;최병기
    • 대한방사선치료학회지
    • /
    • 제28권1호
    • /
    • pp.35-46
    • /
    • 2016
  • 목 적 : 두경부암의 양성자 치료 시 BoS frame ($Q-fix^{TM}$)을 사용하면 후사방향의 빔 조사 시 couch 와 snout 사이 충돌을 피하면서 Airgap 을 최소화할 수 있다. 이는 couch 에서 BoS frame 을 얼마나 많이 extended 시켰는지가 각 치료 빔 방향의 Airgap (환자와 빔 사출구 거리)을 결정하기 때문이다. 이에 본원에서는 BoS frame의 제한점을 개선하기 위하여 고정장치를 자체 제작하였고, 제작한 고정장치의 유용성을 본 연구를 통해 선량학적으로 평가하고자 한다. 대상 및 방법 : 본원에서 양성자치료를 받은 Brain Cancer환자 3명의 빔 각도 중 후사방향의 빔 6개를 선택하였다. 현재 치료계획 되어 있는 환자를 기존 방식대로 BoS frame만 사용했을 때 각 환자마다 왼쪽후사방향, 오른쪽 후사방향의 빔에서 충돌을 피할 수 있는 snout 위치를 측정하고 이 위치에 따른 Airgap과 Lateral penumbra 영역을 계산하고 DVH값을 분석하였다. 같은 환자의 동일한 빔에서 자체 제작한 BoS frame 고정장치를 사용하여 제조회사에서 권고한 set-up 사항보다 BoS frame을 21 cm superior방향으로 set-up을 진행하였고, 그 후 충돌을 피할 수 있는 snout위치를 측정하고 이 위치에서 Airgap과 Lateral penumbra영역을 계산하고 DVH값을 분석하였다. 결 과 : 자체 제작 BoS frame 고정장치를 사용함에 따라 사용하지 않았을 때 보다 snout 위치 즉 Airgap을 각각 각도별로 5.4 cm ~ 15.4 cm 줄일 수 있었다. Lateral penumbra는 BoS frame 고정장치를 사용하면서 Airgap을 감소시킴에 따라 각도별로 선량분포곡선에서 왼쪽, 오른쪽 부분을 0.1 cm ~ 0.4 cm 감소시킬 수 있었다. 자체 제작한 BoS frame 고정장치 사용함으로써 감소한 Lateral penumbra에 의해 정상조직에 들어가는 선량을 비교해보면 Lt.eyeball, Lt.lens, Lt.hippocampus, Lt.cochlea, Rt.eyeball, Rt.lens, Rt.cochlea, Rt. hippocampus, stem에 들어가는 선량이 0 CGE ~ 4.4 CGE 감소한 것을 알 수 있었다. 결 론 : 두경부암의 양성자 치료 시 자체제작 BoS frame 고정장치를 사용함에 따라 사용하지 않았을 때보다 후사방향의 빔에서 snout 위치를 감소시킬 수 있었고, Airgap을 줄여 결과적으로 Lateral penumbra를 감소시켜 정상조직에 불필요한 선량을 최소화 할 수 있었다. 이에 본 연구를 통해 자체제작 BoS frame 고정장치의 유용성을 선량학적으로 평가한 결과, 후사방향의 빔을 사용하는 두경부암 환자의 양성자 치료 시 유용하게 사용 될 것으로 기대된다. 마지막으로 두경부암 뿐만 아니라 다른 부위 양성자 치료에서도 Airgap을 최소한 할 수 있는 방법을 고안하여 Lateral penumbra를 줄일 수 있는 지속적인 연구가 필요할 것이라고 사료된다.

  • PDF

Verification of Secondary Electron Generated by Head Screw in Gamma Knife Using Monte Carlo N-Particle Simulation

  • Kim, Heesoo;Lee, Jeong-Woo
    • 한국의학물리학회지:의학물리
    • /
    • 제31권2호
    • /
    • pp.29-34
    • /
    • 2020
  • Purpose: The interaction of various substances inserted into the human body and radiation can confirm the radiation enhancement effect. A Leksell frame inserted into the human body for gamma knife treatment will cause not only pain and inconvenience to the patient, but also additional exposure to the patient's normal tissues. In this study, we attempt to confirm the additional exposure caused by the interaction of the Leksell frame and thermoplastic mask, and 60Co used for gamma knife treatment. Methods: A 60Co energy of 1.17, 1.33 MeV is applied using Monte Carlo simulation, and fixation screws and thermoplastic mask are fabricated using aluminum and titanium alloy, and Carbon compounds. Results: Results show a dose enhancement of up to 396.27% higher compared with that without a Leksell frame and up to 391.25% in thermoplastic mask. Conclusions: Hence, appropriate treatment methods and materials must be used to reduce additional exposure to normal tissues.

반월형 근위 중족골 절골술에 대한 보강적 축성 K-강선 고정술 : 생체역학적 연구 (Additional axial K-wire Fixation for Proximal Crescentic Metatarsal Osteotomy : A Biomechanical Study)

  • 정홍근;김유진
    • 대한족부족관절학회지
    • /
    • 제7권2호
    • /
    • pp.151-156
    • /
    • 2003
  • Purpose: Proximal crescentic metatarsal osteotomy(PMO) is one of the most common procedures for correcting moderate to severe degree hallux valgus deformity. Although screw fixation is used for osteotomy site stability, loss of reduction can occur. The purpose of this study is to compare the sagittal plane stability of the conventional crescentic PMO fixed with a single screw with that of the crescentic PMO fixed with 1 screw and 2 supplemental K -wires. Material and Methods: Ten matched pairs of cadaveric foot specimens were used for the proximal crescentic metatarsal osteotomy. For one foot specimen of each pair, crescentic osteotomy was fixed with 4mm long threaded cannulated screw, while the matched pair was prepared by adding two axial 1.6mm K-wires to the conventionally fixed 4mm screw. The extensometer was used to measure the osteotomy gap as the metatarsal head was loaded continuously until failure using a servohydraulic MTS Mini Bionix test frame. The strength of fixation was normalized with the bone mineral density (BMD) of the paired specimen $(N{\times}cm^{2}/gm)$, Result: The average strength of the crescentic PMO with axial K-wire fixation ($458.8cm^{2}/gm$, S.D. 434.3) was significantly higher than the standard crescentic PMO ($367.5cm^{2}/gm$, S.D. 397,9) (p=0.05). Conclusion: Supplemental fixation with two axial K-wires can be added to the crescentic PMO to enhance the initial fixation stability to prevent the loss of reduction or dorsal malunion.

  • PDF

피각부 자발성 뇌내출혈의 혈종흡입술을 위한 지표 (Guidelines for Free-Hand Aspiration(FHA) of Putaminal Hemorrhage)

  • 임신길;오민석;임준섭;강명기;곽연상;박승규;송경배;김한웅
    • Journal of Korean Neurosurgical Society
    • /
    • 제30권sup2호
    • /
    • pp.294-299
    • /
    • 2001
  • Objectives : CT-guided stereotactic evacuation for spontaneous intracerebral hemorrhage can minimize the brain damage and can be performed safely and simply under local anesthesia. But that procedure is time consuming and has a risk of rebleeding because of the stress during head pin fixation. So authors describe easy and precise guidelines for FHA of putaminal hemorrhage without stereotactic instrument. Methods and Materials : We analyzed the data of 298 patients who underwent CT-guided stereotactic aspiration of putaminal hematoma in our hospital between January 1990 and December 2000. We divided the patients into three groups according to the location of hematoma : anterior portion, middle portion and posterior portion of putamen. Total number of catheters inserted into the hematoma were 345 and there were with regard to the direction and depth of catheters. Results : Proposed guidelines of catheter insertion to putaminal hemorrhage in our institution. 1) hematoma at the anterior portion of putamen ; Direction of catheter was the midpupillary line of the eye and the point intersecting a line drawn from the burr hole to a point between external auditory meatus(EOM) and 1cm posterior to EOM. Depth of catheter was 6-6.5cm. 2) hematoma at the middle portion of putamen ; Direction of catheter was the midpupillary line of the the eye and the point intersecting a line drawn from the burr hole to a point between 1cm and 2cm posterior to EOM. Depth of catheter was 6.5-7cm. 3) hematoma at the posterior portion of putamen ; Direction of catheter was 15 degree laterally from the midpupillary line of the eye and the point intersecting a line drawn from the burr hole to a point between 2cm and 3cm posterior to EOM. Depth of catheter was 7-7.5cm. We have performed FHA of putaminal hemorrhage in 48 cases according to this guideline. All catheter were inserted exactly at the center of hematoma and average operation time was about 30 minutes. Conclusion : Our proposed guidelines for putaminal hemorrhage are considered to be safe and simple method with similar accuracy and rapid decompression compared with traditional stereotactic method. Main advantages of this technique were unnecessity of stereotactic frame application and less time requirement for hematoma removal.

  • PDF