• 제목/요약/키워드: Head difference

검색결과 1,512건 처리시간 0.032초

The Effect of Different Inflows on the Unsteady Hydrodynamic Characteristics of a Mixed Flow Pump

  • Yun, Long;Dezhong, Wang;Junlian, Yin;Youlin, Cai;Chao, Feng
    • International Journal of Fluid Machinery and Systems
    • /
    • 제10권2호
    • /
    • pp.138-145
    • /
    • 2017
  • The problem of non-uniform inflow exists in many practical engineering applications, such as the elbow suction pipe of waterjet pump and, the channel head of steam generator which is directly connect with reactor coolant pump. Generally, pumps are identical designs and are selected based on performance under uniform inflow with the straight pipe, but actually non-uniform suction flow is induced by upstream equipment. In this paper, CFD approach was employed to analyze unsteady hydrodynamic characteristics of reactor coolant pumps with different inflows. The Reynolds-averaged Naiver-Stokes equations with the $k-{\varepsilon}$ turbulence model were solved by the computational fluid dynamics software CFX to conduct the steady and unsteady numerical simulation. The numerical results of the straight pipe and channel head were validated with experimental data for the heads at different flow coefficients. In the nominal flow rate, the head of the pump with the channel head decreases by 1.19% when compared to the straight pipe. The complicated structure of channel head induces the inlet flow non-uniform. The non-uniformity of the inflow induces the difference of vorticity distribution at the outlet of the pump. The variation law of blade to blade velocity at different flow rate and the difference of blade to blade velocity with different inflow are researched. The effects of non-uniform inflow on radial forces are absolutely different from the uniform inflow. For the radial forces at the frequency $f_R$, the corresponding amplitude of channel head are higher than the straight pipe at $1.0{\Phi}_d$ and $1.2{\Phi}_d$ flow rates, and the corresponding amplitude of channel head are lower than the straight pipe at $0.8{\Phi}_d$ flow rates.

각종 송출 호오스의 구경 및 길이가 농용양수로의 소요동력에 미치는 영향 (Influence of Flowing Velocity and Length of Delivery Hoses on Power Requirement of Agricultural pump.)

  • 김기대;김성래;이한만
    • Journal of Biosystems Engineering
    • /
    • 제4권2호
    • /
    • pp.46-52
    • /
    • 1979
  • The water delivery hose for agricultural pump is getting popular in rural areas in korea. Friction head loss, discharge, and power requirements were measured in various discharge for different material and diameter of hose to get basic data for economical use in agricultural pump. The results attained in this study were as follows ; 1. Friction head loss increased significantly as the velocity increased, and the difference of velocity between the different diameter of hose was bigger than that between materials, which was resulted in the increase of the friction head loss. 2. Friction head loss in the case of that the velocity with 2m/sec was constant was about 3.53 to 4.01 m/100m in the diameter 3" and about 2.30 to 3.10 m/100m in the diameter 4". Material A of diameter 3" showed the maximum value 8.4m/100m in Reynolds number $2.0\times10^5$, 4" got the minimum value 2.24m/100m, the difference between these values was bigger than 6m per 100 meters in the friction head loss. 3. Darcy-Weisbach formular with friction coefficient [f] calculated by Nikurades formular in the smooth pipe or with friction coefficient [f] calculated on the base of C value 125 in Hazen-Williams formular was available in friction head loss of the water discharger hose in rural areas. 4. Total head increased as friction head loss increased , meanwhile total discharge decreased, and 20 percents of energy was more saved in Material C 4″pipe than Material A 3″pipe in the view point from the discharge per unit power requirement, this phenomenon suggested that long distance pipe would be advantage in larger diameter pipe for save of energy. for save of energy.

  • PDF

휴대폰 전파인 인제 흡수전력량과 온도 상승량 산출 (Computation of Temperature Rising by Absorbed Power Radiated from a Portable Phone)

  • 이승학;김채영;강승진
    • 한국전자파학회논문지
    • /
    • 제12권3호
    • /
    • pp.409-426
    • /
    • 2001
  • 본 논문은 유한차분 시간영역 해석법(Finite-Difference Time-Domain Method)을 사용하여 900 MHz용 휴대폰으로부터 방출된 전파의 인체 두부(頭部)에 흡수된 전력량을 산출하였고, 흡수전력으로 인한 두부내의 온도 상승량을 계산하였다. 이를 위하여 인체두부를 5층 매질로 모델링하였고, 휴대폰은 금속상자에 부착된 모노폴안테나로 모델링하였다. 모델링에 사용된 인체두부와 휴대폰의 크기는 상용의 값을 사용하였다. 사용된 모노폴 안테나의 길이는 8.16 cm이고, 휴대폰의 출력은 상용 900 MHz의 600 mW을 사용하였다. 설정된 모델링하에서 인체의 위해(危害)정도를 알려주는 지수는 1 g, 10 g 평균 北 흡수율(SAR-Specific Absorption Rate)의 분포를 계산하였고 이에 따른 1g, 10 g 평균 온도 상승량을 계산하였다. 그 결과 비흡수율이 최대가 되는 지점은 인체 두부의 피부 부분이었고 최대 온도 증가 위치는 이보다 안쪽부분에서 나타났다. 인체 두부와 휴대폰의 이격거리에 따른 SAR과 온돈 상승량을 계산하였다.

  • PDF

평면파에 노출된 인체 두부의 전력흡수 해석 (A Study of Power Absorption in Human Head Exposed to Plane Wave)

  • 이애경;조광윤;이혁재
    • 한국전자파학회논문지
    • /
    • 제8권6호
    • /
    • pp.665-680
    • /
    • 1997
  • 본 논문에서는 350 MHz와 900 MHz 평면파에 노출된 다양한 모델의 인체 두부 내 비흡수율(specific abs sorption rate, SAR)의 분포를 해석하였다. 해석 방법은 유한차분시간영역(finite-difference time-domain, FDTD) 방법이며, 인체 두부 모델로서 균질 매질의 구형모델, 균질의 실질적인 형태를 갖는 모텔 그리고 실질적인 형태를 갖는 비균질 모델이 사용된다. 입사 평면파의 편파는 인체 길이방향과 일치하며, 진행방향은 뒤에서 암으로, 그리고 앞에서 뒤로 향하는 두 가지 경우를 다룬다. 얻어진 연구결과는 다음과 같다. 1) 세 가지 모델의 평균 SAR은 비슷하나 국부 SAR은 큰 차이가 있다. 2) 주파수가 900 MHz보다 두부의 공진이 일어나는 대역인 350 MHz에서 복사전력이 더 깊이 침투한다. 3) 후방입사 평변파의 경우에는 두부가 아닌 목 부근에서 "hot spot"이 일어난다. 4) 전방입사 평면파의 경우에는 900 MHz에서는 코, 350 MHz의 경우에는 입술 위와 턱 부분에 "hot spot"이 나타난다.

  • PDF

Effects of strengthening and stretching exercises on the forward head posture

  • Lee, Song Hee;Lee, Joon Hee
    • 국제물리치료학회지
    • /
    • 제7권2호
    • /
    • pp.1046-1050
    • /
    • 2016
  • The purpose of this study was to investigate the effects of strengthening and stretching exercises on forward head angle and static dynamic balance ability. 21 adults with the forward head posture were participated in this study. Subjects were randomly assigned to strengthening exercise group I(n=11) and stretching exercise group II (n=10) respectively. Each group were underwent six intervention over the period of 2 weeks, each session lasting 30 minutes. During a preliminary examination, forward head angle and static dynamic balance were measured, and a post examination was conducted that involved same procedure as preliminary examination. There were significant differences in forward head angle after exercise in both groups. In the strengthening group, center of gravity total sway distances was significantly changed under all conditions. In the stretching group, center of gravity total sway distances was significantly changed when subjects had their eyes open while standing on an foam surface. There were significant changes in center of gravity sway velocities in the strengthening group under all conditions, and the same was true in the stretching group only when the subjects had their eyes open while standing on an foam surface. In the comparison between groups, eyes closed while standing on a firm surface was significantly different. There was a significant difference in dynamic balance of the stretching group when the subjects tilted their bodies forward, and there was a statistically significant difference between groups under the same condition. The results of this study suggest that forward head posture can be corrected through therapeutic exercise, and muscle strengthening exercise more effective in improving static balance of forward head posture more than stretching exercise.

Impact of Screw Type on Kyphotic Deformity Correction after Spine Fracture Fixation: Cannulated versus Solid Pedicle Screw

  • Arbash, Mahmood Ali;Parambathkandi, Ashik Mohsin;Baco, Abdul Moeen;Alhammoud, Abduljabbar
    • Asian Spine Journal
    • /
    • 제12권6호
    • /
    • pp.1053-1059
    • /
    • 2018
  • Study Design: Retrospective review. Purpose: To detect the effect of cannulated (poly-axial head) and solid (mono-axial head) screws on the local kyphotic angle, vertebral body height, and superior and inferior angles between the screw and the rod in the surgical management of thoracolumbar fractures. Overview of Literature: Biomechanics studies showed that the ultimate load, yield strength, and cycles to failure were significantly lower with cannulated (poly-axial head) pedicle comparing to solid core (mono-axial head). Methods: The medical charts of patients with thoracolumbar fractures who underwent pedicle screw fixation with cannulated or solid pedicle screws were retrospectively reviewed; the subjects were followed up from January 2011 to December 2015. Results: Total 178 patients (average age, $36.1{\pm}12.4years$; men, 142 [84.3%]; women, 28 [15.7%]) with thoracolumbar fractures who underwent surgery and were followed up at Hamad Medical Corporation were classified, based on the screw type as those with cannulated screws and those with solid screws. The most commonly affected level was L1, followed by L2 and D12. Surgical correction of the local kyphotic angle was significantly different in the groups; however, there was no significant difference in the loss of correction of the local kyphotic angle of the groups. Surgical correction of the reduction in the vertebral body height showed statistical significance, while the average loss of correction in the reduction of the vertebral body height was not significantly different. The measurement of the angles made by the screws on the rods was not significantly different between the cannulated (poly-axial head) and solid (mono-axial head) screw groups. Conclusions: Solid screws were superior in terms of providing increased correction of the kyphotic angle and height of the fractured vertebra than the cannulated screws; however, no difference was noted between the screws in the maintenance of the superior and inferior angles of the screw with the rod.

The Influence of Non-Linear Frequency Compression on the Perception of Speech and Music in Patients with High Frequency Hearing Loss

  • Ahn, Jungmin;Choi, Ji Eun;Kang, Ju Yong;Choi, Ik Joon;Lee, Myung-Chul;Lee, Byeong-Cheol;Hong, Sung Hwa;Moon, Il Joon
    • 대한청각학회지
    • /
    • 제25권2호
    • /
    • pp.80-88
    • /
    • 2021
  • Background and Objectives: Non-linear frequency compression (NLFC) technology compresses and shifts higher frequencies into a lower frequency area that has better residual hearing. Because consonants are uttered in the high-frequency area, NLFC could provide better speech understanding. The aim of this study was to investigate the clinical effectiveness of NLFC technology on the perception of speech and music in patients with high-frequency hearing loss. Subjects and Methods: Twelve participants with high-frequency hearing loss were tested in a counter-balanced order, and had two weeks of daily experience with NLFC set on/off prior to testing. Performance was repeatedly evaluated with consonant tests in quiet and noise environments, speech perception in noise, music perception and acceptableness of sound quality rating tasks. Additionally, two questionnaires (the Abbreviated Profile of Hearing Aid Benefit and the Korean version of the International Outcome Inventory-Hearing Aids) were administered. Results: Consonant and speech perception improved with hearing aids (NLFC on/off conditions), but there was no significant difference between NLFC on and off states. Music perception performances revealed no notable difference among unaided and NLFC on and off states. The benefits and satisfaction ratings between NLFC on and off conditions were also not significantly different, based on questionnaires, however great individual variability preferences were noted. Conclusions: Speech perception as well as music perception both in quiet and noise environments was similar between NLFC on and off states, indicating that real world benefits from NLFC technology may be limited in Korean adult hearing aid users.

The Influence of Non-Linear Frequency Compression on the Perception of Speech and Music in Patients with High Frequency Hearing Loss

  • Ahn, Jungmin;Choi, Ji Eun;Kang, Ju Yong;Choi, Ik Joon;Lee, Myung-Chul;Lee, Byeong-Cheol;Hong, Sung Hwa;Moon, Il Joon
    • Journal of Audiology & Otology
    • /
    • 제25권2호
    • /
    • pp.80-88
    • /
    • 2021
  • Background and Objectives: Non-linear frequency compression (NLFC) technology compresses and shifts higher frequencies into a lower frequency area that has better residual hearing. Because consonants are uttered in the high-frequency area, NLFC could provide better speech understanding. The aim of this study was to investigate the clinical effectiveness of NLFC technology on the perception of speech and music in patients with high-frequency hearing loss. Subjects and Methods: Twelve participants with high-frequency hearing loss were tested in a counter-balanced order, and had two weeks of daily experience with NLFC set on/off prior to testing. Performance was repeatedly evaluated with consonant tests in quiet and noise environments, speech perception in noise, music perception and acceptableness of sound quality rating tasks. Additionally, two questionnaires (the Abbreviated Profile of Hearing Aid Benefit and the Korean version of the International Outcome Inventory-Hearing Aids) were administered. Results: Consonant and speech perception improved with hearing aids (NLFC on/off conditions), but there was no significant difference between NLFC on and off states. Music perception performances revealed no notable difference among unaided and NLFC on and off states. The benefits and satisfaction ratings between NLFC on and off conditions were also not significantly different, based on questionnaires, however great individual variability preferences were noted. Conclusions: Speech perception as well as music perception both in quiet and noise environments was similar between NLFC on and off states, indicating that real world benefits from NLFC technology may be limited in Korean adult hearing aid users.

선추적공식을 이용한 머리전달함수의 회전타원체 형상 모델링 (A prolate spheroidal head modeling of head related transfer function based on ray tracing formula)

  • 조현;박영진;박윤식
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2008년도 춘계학술대회논문집
    • /
    • pp.934-938
    • /
    • 2008
  • To customize individual characteristics of HRTF, a spherical model has been used for structural modeling technique. A pseudo-code of prolate spheroidal HRTF caused by incident acoustic point source is already developed, and it can be used a head shadow filter for structural modeling of HRTF. In this research, to see the necessity and efficiency of spheroidal head modeling, ITD optimization is performed on CIPIC HRTF database. From given cost function, ITD-optimized spheroidal head model, whose ITD information is the most matched version of measured ITD information, is found by varying head parameters subject by subject. By comparing results of ITD-optimized spheroids and ITD-optimized spheres, we concluded that a spherical head model is more efficient way of generating head shadow effect than a spheroidal head model does.

  • PDF

두부자세와 경추형태에 따른 근활성의 변화에 관한 연구 (Changes of the Electromyographic Activity by Head Posture and Cervical Spine Shape)

  • Ho-Chun Hwang;Kyung-Soo Han;Chan Jung
    • Journal of Oral Medicine and Pain
    • /
    • 제21권2호
    • /
    • pp.393-405
    • /
    • 1996
  • This study was performed to investigate the effects of changes of head posture and cervical spine shape on the mandibular resting or clenching electromyographic(EMG) activity in anterior temporalis(TA), masseter(MM), sternocleidomastoid muscle(SCM) and trapezius insertion(TI). 30 patients with Temporomandibular Disorders(TMDs) participated in this study. EMG activity($\mu$V) at rest and clenching was observed in four head postures, namely natural head posture(NHP), forward head posture(FHP), upward head posture(UHP), and downward head posture(DHP). For taking in upward or downward head posture head was inclined 10$^{\circ}$ upward or downward and CROM$^\textregistered$(cervical-range-of motion, Performance attainment Inc., USA) was used to maintain same posture during the procedure, and BioEMG$^\textregistered$ (Bioelectromyograph, Bioresearch Inc., USA) was used to record EMG activity in the above four muscles at eight locations on both sides. The recorded EMG activity($\mu\textrm{V}$) were compared and analyzed by cervical spine shape such as the head position from plum line, cervical curvature, and cervical inclination. Head position from plum line was measured in vertical plate calibrated with cm scale, comical curvature by radius was measured with adjustable curved ruler, and cervical inclination by cervical vertebrae tangent(CVT)was measured in lateral cephalograph. The results obtained were as follows : 1. Mean value of head position from plum line, cervical curvature, and cervical inclination were 4.8cm, 26.7cm, and 86.6$^{\circ}$, respectively, And There were no correlationship among these items. 2. For resting EMG activity by head posture, the value in anterior temporalis was higher at FHP than at DHP, the value in masseter was higher at FHP than at NHP, and DHP, the value in sternocleidomastoid muscle was higher at UHP than at NHP, and the value in trapezius insertion was higher at FHP and DHP than, NHP and UHP. The clenching EMG activity, however, did not show any difference by head posture. 3. Comparison of resting and clenching EMG activity between higher and lower groups by head position from plum line, cervical curvature, and cervical inclination did not show any significant difference. From this result, the author concluded that the cervical spine shape had not significantly affected to EMG activity in usual patients with TMDs.

  • PDF