• Title/Summary/Keyword: Head Loss of Filtration

Search Result 30, Processing Time 0.025 seconds

Determination of the optimum filtration conditions in pretreatment of seawater desalination by reverse osmosis (역삼투법 해수담수화 전처리 여과공정의 최적조건)

  • Kim, Seung-Hyun;Yoon, Jong-Sup;Lee, Seockheon
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.23 no.2
    • /
    • pp.207-214
    • /
    • 2009
  • This study examines the optimum filtration conditions in pretreatment of seawater desalination by reverse osmosis. For this purpose, Masan bay seawater is treated through a gravity filter column while $FeCl_3$ is added as coagulant. The conditions of coagulantd osage, media depth, filtration rate, and backwash time are evaluated. The study results show that the filtrate quality improved with increasing coagulant dosage, but head loss rapidly increased. After 4mg/L, the unit filter run volume reduced to less than $200m^3/m^2$. Considering the head loss development, 4mg/L is determined as the optimum dosage. The better filtrate qualities are obtained with depth of 100cm than that of 80cm. The two stage filtration, which outperformed the single stage filtration, is suggested for treatment of Masan bay. The filtration rate of 5m/h is decided as the optimum condition considering the head loss development. At 10m/h, the filtrate quality deteriorated even though the extent was minimal, and head loss increased rapidly. The backwash time of 10 min is decided appropriate.

하수처리장 방류수를 이용한 인공함양 가능성 평가

  • 김병군;서인석;홍성택;김형수
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2002.09a
    • /
    • pp.257-260
    • /
    • 2002
  • The main purpose of this research is to find suitable treatment methods of wastewater effluent for artificial recharge. For this purpose, we search the effluent quality of wastewater treatment plant and possibility of additional filtration process. Particles ranged 2 ~ 5 ${\mu}{\textrm}{m}$ and 15~20 ${\mu}{\textrm}{m}$ in "T" WWTP(Waste Water Treatment Plant) effluent were relatively dominant. In dual-media filtration system operation, head-loss development of column 1 was about two times faster than column 2, and head-loss development within 5 cm from surface was very important factor in operation, Conclusively, for the stable filtration and running time of 1.5~2 day, influent turbidity must keep 5 NTU or below, and filtration system must operated at 280 m/day or below. After filtration of WWTP effluent, water quality reached satisfactory level. This water has potential of agricultural reusing, flushing water in building, recharging water to river or stream at dry season and artificial recharge of ground water.und water.

  • PDF

A Study on the Velocity, the Grain Size and the Bed Depth of the Rapid Filter (급속여과지(急速濾過池)의 여과속도(濾過速度)와 여재구성(濾材構成)의 연구(硏究) -여과저항(濾過抵抗)을 중심(中心)으로-)

  • Kang, Yong Tai
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.3 no.3
    • /
    • pp.1-7
    • /
    • 1983
  • In spite of extensive knowledge of the surface chemistry and the transport mechanism in filtration systems, there is still insufficient understanding of the physical characteristics of suspensions and the system components. Because of this, no filtration mechanisms are mathematically generalized to the full extent. The purpose of this paper is to propose experimental equations for the filtration process. using the tracer study in filter layer. Some of results are as follows. (1) The Volume of the specific deposit (${\sigma}$) in filtration was directly measurable using the tracer study without interrupting the filtration. (2) It was also confirmed that the head loss in filtration was greatly in fluenced by the micro-air babbles. (3) The correction coefficient(f) was introduced into the Kozeny-Carman equation in order to apply it for the clogging filter media. The coefficient(f) was experimentally obtained. The total head loss of the filter media is given by next equation. $${\frac{h}{h_0}}={\frac{1}{L}}{\int}^{z=L}_{z=0}f({\sigma})g({\varepsilon}_0,{\sigma})dz$$ $$f=aexp(-b{\sigma})$$ The above equation was applicable without regard to the variation of the suspension concentration, the filter medium diameter, the filter depth, the filtration velocity, and the amount of aluminum in all continuous filtration experiments. (4) The total head loss was graphically generalized assuming mathematical filtration models I II (see fig. 7,8) (5) The total head loss was obtained from the filtration model in the field filtration conditions. (see fig. 9,10)

  • PDF

Study on Head Loss in Aerated Biofilm Filtration Reactor (폭기생물막(曝氣生物膜) 여과지(濾過池)의 여과저항(濾過抵抗)에 관한 연구(研究))

  • Kang, Yong Tae;Hyun, Kil Soo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.12 no.2
    • /
    • pp.285-291
    • /
    • 1992
  • The purpose of this research, through kinetic analyses and pilot plant experimentation of biofilm filtration reactor, is to study the theoretical equation of head loss in the Biofilm Reactor. The Head loss in the biofilm reactor has occurred due to the biofilm growth and the adhesion to the media surface and stagnation of upflow air bubble, which have caused the pore spaces to become smaller. On a basis of the head loss theory of sand filtration, therefore, the following equation of head loss for the biofilm reactor was proposed from this research results and proved to be possible to apply the equation for practical design of the biofilm filter. $h={\frac{h_o}{L}}{\int}^L_00.58\exp[-4.5){\sigma}_B)][{\frac{1-{\varepsilon}_o+({\sigma}_B)}{1-{\varepsilon}_o}}]^2{[\frac{{\varepsilon}_o}{{\varepsilon}_o-({{\varepsilon}_B)}}]^3dz$ here ${\sigma}_B=0.130+0.001{\theta}$.

  • PDF

Comparison of the filtration performance by different media in pretreatment of seawater desalination by reverse osmosis (여재 종류에 따른 역삼투법 해수담수화 시설 전처리 여과공정의 성능비교)

  • Kim, Seung-Hyun;Yoon, Jong-Sup;Lee, Seockheon
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.23 no.2
    • /
    • pp.215-222
    • /
    • 2009
  • This study compares the performance of the filters with various media in pretreatment of seawater desalination by reverse osmosis. For this purpose, Masan bay seawater is used as raw water. The filter performance is evaluated by the filtrate quality and the head loss development. Five media is selected in this study: anthracite, $Filtralite^{(R)}$, sand, Pumice, $AFM^{(R)}$. These media are used in combination for dual media filter and alone for mono media filter. The comparison results show that NC0.8-1.6 is the best $Filtralite^{(R)}$. The dual media filter of NC0.8-1.6 and sand outperformed other filters in particle removal. The dual media filter of anthracite and sand showed good performance in organic removal. The mono media filter of Pumice produced the similar filtrate quality as the mono media filter of sand although the effective size of Pumice is considerably greater than that of sand. Due to big size, head loss development is maintained slow in the filtration of Pumice.

Characteristics of Depth Filtration for Various Filter-Bed Configurations (심층여과지의 여층구성에 따른 여과특성 비교)

  • An, Jong-Ho;Yun, Jae-Heung
    • Journal of Korea Water Resources Association
    • /
    • v.34 no.5
    • /
    • pp.459-472
    • /
    • 2001
  • The objective of this study is to evaluate the filtration efficiency of deep-bed filters by comparing to single and dual media filters. Pilot-plant tests using four-filter columns were conducted for the comparison of head loss development and filtered water quality. The dual-media filter showed greater initial head loss, but less rate of head-loss development than those of the coarse-sand-0deep-bed filters. For 180 m/day of filtration rate, the dual-media filter produces larger unit production rate by 30-40%, and the turbidities of filtered water were below 0.1 NTU. The initial breakthrough could be effectively controlled by the dual-media filter rather than coarse-sand-deep-bed filters.

  • PDF

A Study on the Distribution of Hydraulic Head Along the Lateral in a Pilot-Scale Riverbank Filtration (강변여과에서 파일럿규모 수평집수관의 수두분포 연구)

  • Jeong, Jae-Min;Park, Jae-Young;Lee, Jong-Jin;Kim, Yong-Woon;Kim, Seung-Hyun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.5
    • /
    • pp.334-339
    • /
    • 2013
  • A pilot-scale sand-box experiment simulating a lateral of collector well used in riverbank filtration was performed, and hydraulic head distributions along the lateral were measured according to the various drawdowns at the well. The results of this experiment were compared to the predicted values obtained using a theory previously developed by Kim in order for its validation. This theory predicts the head loss in a large-scale lateral given the loss in a small-scale one, and to have actual values for comparison, the results from a lab-scale experiment previously performed by Kim were employed. Comparing the experimental values to the extrapolated value indeed confirmed the validity of the theory. A procedure to determine the hydraulic head distribution of a practical-scale lateral was also presented applying the theory to the experimental result of this study in an effort to show the process of lateral design for riverbank filtration.

A Study on the Optimum Design of Horizontal Collectors in Floodplain Filtration (홍수터여과에서 집수관의 최적설계 연구)

  • Pi, Seong-Min;Kim, Seung-Hyun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.6
    • /
    • pp.430-437
    • /
    • 2012
  • In order to obtain information on the design parameters of the horizontal laterals in floodplain filtration, laboratory-scale sand-box experiments were performed where the head distributions on the laterals and the groundwater profiles were measured according to the change in parameters including lateral diameter, hydraulic conductivity of the sand, water level at the well and raw-water supply rate. Measured data were analyzed using a numerical code in order to identify the discharge intensity distribution along the laterals. It was observed from the result that the lowering of the water level at the well had minimal adverse effect on the performance of the floodplain filtration. Results also elucidated that the low conveyance of the laterals to transmit the filtrate was compensated and supplemented by a natural augmentation in horizontal conveyance through the aquifer when the raw-water supply rate exceeded the adequate recovery rate. With this mechanism, the water quality is expected to improve further since the travel distance through the aquifer is amplified. Based on these findings it can be suggested that the diameter of the lateral used in the floodplain filtration may be smaller than those in riverbank/bed filtration. It was also found that the ratio between the head loss occurring in a lateral and the total head loss in the floodplain filtration was proportional to the exit velocities of the laterals, which may be used to design and/or evaluate the lateral in floodplain filtration.

A Study on the Adhesion Model of the Deposit in Rapid Filter (급속여과지에 있어서 현탁물 부착모델에 관한 연구)

  • Gang, Yong-Tae;Yu, Dong-Seon
    • 수도
    • /
    • s.30
    • /
    • pp.57-62
    • /
    • 1984
  • This paper is a study on the adhesion model of the deposit in rapid filter. In this paper, ellipse adhesion model modified was proposed. With that head-loss equation during filtration that is very consistent with the experimental value was derived. In the design of the rapid filter, after this head-loss equation during filtration derived may contribute to the decision of optimum filter height.

  • PDF

Characteristics of High-Rate Filtration with Filtration Aids (급속여과공정에서의 여과보조제 사용에 따른 여과특성)

  • Ahn, Jong-Ho;Yoon, Jae-Heung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.14 no.3
    • /
    • pp.260-270
    • /
    • 2000
  • The objective of this study is to evaluate the effect of filter aids in the dual-media rapid filtration. Paper-filter tests were conducted to determine the proper dosages of coagulant and filter aid, and pilot plant tests using two dual-media filter columns were performed for a variety of filtration rates. Using a filter aid (non-ionic polymer), the maximum feasible filtration rate is 480m/day, while turbidity is less than 0.3 NTU and filter run-time is about 70 hours. It is possible to increase the filtration rate up to 360 m/day for keeping the turbidity less than 0.1 NTU. Turbidity increases for the filtration rate greater than 360m/day. In general, the quality of filtered water with a filter aid is stable, while the filter maintains a sufficient filter run-time for a maximum allowable head loss. Particularly, the initial breakthrough can be effectively controlled. The use of a filter aid may be one of the methods applicable if the turbidity of filtered water is required to be improved or if the filter breakthrough limits filter run-time.

  • PDF