• Title/Summary/Keyword: Head Distribution

Search Result 915, Processing Time 0.022 seconds

Carbon-ion radiotherapy in osteosarcoma of the mandible: a case report

  • Ha, Tae-Wook;Park, Slmaro;Youn, Min Yeong;Kim, Dong Wook;Kim, Hyung Jun
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.47 no.4
    • /
    • pp.315-320
    • /
    • 2021
  • Carbon-ion radiotherapy (CIRT) is on the rise as a treatment choice for malignant tumor. Compared to conventional radiotherapy, particle beams have different physical and biological properties. Particle beam provides a low entry dose, deposits most of the energy at the endpoint of the flight path, and forms an asymptotic dose peak (the "Bragg peak"). Compared to protons, carbon with its larger mass decreases beam scattering, resulting in a sharper dose distribution border. We report a 50-year-old male who underwent CIRT without surgical resection on osteosarcoma of the mandible. After CIRT, the patient's pain was gone, and the malignant mass remained stable with accompanying necrosis. Nine months later, however, magnetic resonance imaging demonstrated progression of the left mandibular osteosarcoma with pulmonary metastases. After multidisciplinary discussion, concurrent chemoradiotherapy was conducted. While necrotic bone segments came out of the mandible during subsequent periodic outpatient visits, the tumor itself was stable. Thirty months after his first visit and diagnosis, the patient is waiting for chemotherapy. Although CIRT is superior in treating radioresistant hypoxic disease, CIRT is in its infancy, so care must be taken for its indications and complications.

Factors Affecting Income from Public Agricultural Land Use: An Empirical Study from Vietnam

  • PHAM, Phuong Nam;TRAN, Thai Yen
    • The Journal of Asian Finance, Economics and Business
    • /
    • v.9 no.6
    • /
    • pp.1-9
    • /
    • 2022
  • The study aims to determine the factors and their influence on the income from using public agricultural land of households. Public agricultural land is agricultural land, including land for growing annual crops, perennial crops, and land for aquaculture, leased by commune-level People's Committees with a lease term of not more than 5 years. Secondary data were collected for the 2017-2021 period at state agencies. Primary data were collected from a survey of 150 households renting public agricultural land. The regression model assumed that there were 28 factors belonging to 7 groups. The test results show that 25 factors affect income, and 03 factors do not. The group of COVID-19 pandemic factors has the strongest impact, followed by the groups of agricultural product market factors, land factors, capital factors, production cost factors, labor factors, and climatic factors. The impact rate of COVID-19 pandemic factors is the largest (23.00%); The impact rate of climatic factors is the smallest (6.04%). Proposals to increase income include good implementation of disease prevention and control; increasing the land lease term; accurately forecasting the supply and demand of the agricultural market; raising the level of the household head; ensuring sufficient production capital, and adapting to the climate.

Numerical study on thermal-hydraulics of external reactor vessel cooling in high-power reactor using MARS-KS1.5 code: CFD-aided estimation of natural circulation flow rate

  • Song, Min Seop;Park, Il Woong;Kim, Eung Soo;Lee, Yeon-Gun
    • Nuclear Engineering and Technology
    • /
    • v.54 no.1
    • /
    • pp.72-83
    • /
    • 2022
  • This paper presents a numerical investigation of two-phase natural circulation flows established when external reactor vessel cooling is applied to a severe accident of the APR1400 reactor for the in-vessel retention of the core melt. The coolability limit due to external reactor vessel cooling is associated with the natural circulation flow rate around the lower head of the reactor vessel. For an elaborate prediction of the natural circulation flow rate using a thermal-hydraulic system code, MARS-KS1.5, a three-dimensional computational fluid dynamics (CFD) simulation is conducted to estimate the flow rate and pressure distribution of a liquid-state coolant at the brink of significant void generation. The CFD calculation results are used to determine the loss coefficient at major flow junctions, where substantial pressure losses are expected, in the nodalization scheme of the MARS-KS code such that the single-phase flow rate is the same as that predicted via CFD simulations. Subsequently, the MARS-KS analysis is performed for the two-phase natural circulation regime, and the transient behavior of the main thermal-hydraulic variables is investigated.

Redescription of three trapanian nudibranchs (Nudibranchia, Goniodorididae) from Korea with a key to the species

  • Jung, Dae-Wui;Kil, Hyun Jong;Nam, Eunjung;Kim, Hyeonggeun;Kim, Chang-Bae
    • Journal of Species Research
    • /
    • v.11 no.3
    • /
    • pp.169-173
    • /
    • 2022
  • Three species belonging to the genus Trapania Pruvot-Fol, 1931 are redescribed from Korea in this paper: Trapania euryeia Gosliner & Fahey, 2008, T. japonica (Baba, 1935), and T. toddi Rudman, 1987. Among these species, T. japonica is newly added to Korean fauna. The genus Trapania is characterized by a pair of extra-rhinophoral appendages on each side of the head, tentacular foot corners, a pair of extra-branchial appendages present around the gill, radula formula N×1.0.1. and consists of denticulated teeth, triaulic reproductive system, and minute spines on the armed penis. Herein, synonyms of the genus Trapania are summarized through a detailed literature review and the diagnostic characters of the genus Trapania are provided. Three species of the genus Trapania from Korea are distinguished from each other based on the color of extra-rhinoporal appendages and extra-branchial appendages, ground color, and distribution range of the brown markings on the dorsal surface. A taxonomic key to the genus Trapania in Korea is provided. In addition, the morphological characteristics of three trapanian nudibranchs in Korea are described and detailed photos of living animal are provided.

Comparison of Dose Statistics of Intensity-Modulated Radiation Therapy Plan from Varian Eclipse Treatment Planning System with Novel Python-Based Indigenously Developed Software

  • Sougoumarane Dashnamoorthy;Karthick Rajamanickam;Ebenezar Jeyasingh;Vindhyavasini Prasad Pandey;Kathiresan Nachimuthu;Imtiaz Ahmed;Pitchaikannu Venkatraman
    • Progress in Medical Physics
    • /
    • v.33 no.3
    • /
    • pp.25-35
    • /
    • 2022
  • Purpose: Planning for radiotherapy relies on implicit estimation of the probability of tumor control and the probability of complications in adjacent normal tissues for a given dose distribution. Methods: The aim of this pilot study was to reconstruct dose-volume histograms (DVHs) from text files generated by the Eclipse treatment planning system developed by Varian Medical Systems and to verify the integrity and accuracy of the dose statistics. Results: We further compared dose statistics for intensity-modulated radiotherapy of the head and neck between the Eclipse software and software developed in-house. The dose statistics data obtained from the Python software were consistent, with deviations from the Eclipse treatment planning system found to be within acceptable limits. Conclusions: The in-house software was able to provide indices of hotness and coldness for treatment planning and store statistical data generated by the software in Oracle databases. We believe the findings of this pilot study may lead to more accurate evaluations in planning for radiotherapy.

Residual stress distribution analysis in a J-groove dissimilar metal welded component of a reactor vessel bottom head using simulation and experiment

  • Dong-Hyun Ahn;Jong Yeon Lee;Min-Jae Choi;Jong Min Kim;Sung-Woo Kim;Wanchuck Woo
    • Nuclear Engineering and Technology
    • /
    • v.56 no.2
    • /
    • pp.506-519
    • /
    • 2024
  • To simulate the verification process using materials from a decommissioned reactor, a mock-up of the bottom-mounted instrument nozzle in the Kori 1 reactor, where the nozzle was attached to a plate by J-groove dissimilar metal welding, was fabricated. The mock-up distortion was quantified by measuring the plate surface displacement after welding. The residual stresses formed on the support plate surface and the inner surface of the nozzle were then analyzed using the hole-drilling method, contour method, and neutron diffraction. Welding simulations were performed using a 3D finite element method to validate the measured results. The measured and computed stress distributions on the support plate exhibited reasonable agreement. Conversely, the stresses on the inside of the nozzle were found to have an indisputable difference in the contour method and neutron diffraction measurements, which demonstrated strong tensile and compressive hoop stresses, respectively. The possible origins of such differences were investigated and we have provided some suggestions for a precise evaluation in the simulation. This study is expected to be useful in future research on decommissioned reactors.

Research of 6 MeV Electron Dose Distribution (6 MeV Electron Therapy에서의 Electron Dose Distribution에 관한 연구)

  • Je Jae-Yong;Park Chul-Woo;Jin Sung-Jin;Park Eun-Tae
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.17 no.2
    • /
    • pp.161-166
    • /
    • 2005
  • Purpose : Electron is used for the treatment of skin cancer, breast cancer, and head and neck cancer in clinic. Our study is performed to check the isodose distribution in source surface distance(SSD)and source bolus distance(SBD)setup, nipple influence to isodose distribution of electron, junctional area isodose variation of photon and electron field. Materials and Methods : The electron dose distribution measures the diameter for 20 cm hemisphere paraffin phantom 2 made. It inserted the film between 2 paraffin phantom and it investigated it got radiation and dose distribution curve. Results : The 8% of isodose difference is with the surface distance(SSD)and source bolus distance(SBD)setup. The electon when the nipple exists inside the field, as nipple size it cuts the bolus and when it puts out and there is a possibility of getting the dose distribution which is homogeneous. When in the junction of electron and photon it uses the bolus it uses in the electron field whole, there is a possibility of getting the dose distribution which is homogeneous. Conclusion : The dose distribution decrease from the SBD setup. To reduce the influence of nipple, corresponding volume of bolus should be removed. And bolus covering all the electron field reduced hot and cold spot of junctional area of photon. In the future becomes the research which sees an effective electron therapy.

  • PDF

Supraclavicular Brachial Plexus block with Arm-Hyperabduction (상지(上肢) 외전위(外轉位)에서 시행(施行)한 쇄골상(鎖骨上) 상완신경총차단(上腕神經叢遮斷))

  • Lim, Keoun;Lim, Hwa-Taek;Kim, Dong-Keoun;Park, Wook;Kim, Sung-Yell;Oh, Hung-Kun
    • The Korean Journal of Pain
    • /
    • v.1 no.2
    • /
    • pp.214-222
    • /
    • 1988
  • With the arm in hyperabduction, we have carried out 525 procedures of supraclavicular brachial plexus block from Aug. 1976 to June 1980, whereas block with the arm in adduction has been customarily performed by other authors. The anesthetic procedure is as follows: 1) The patient lies in the dorsal recumbent position without a pillow under his head or shoulder. His arm is hyperabducted more than a 90 degree angle from his side, and his head is turned to the side opposite from that to be blocked. 2) An "X" is marked at a point 1 cm above the mid clavicle, immediately lateral to the edge of the anterior scalene muscle, and on the palpable portion of the subclavian artery. The area is aseptically prepared and draped. 3) A 22 gauge 3.5cm needle attached to a syringe filled with 2% lidocaine (7~8mg/kg of body weight) and epineprine(1 : 200,000) is inserted caudally toward the second portion of the artery where it crosses the first rib and parallel with the lateral border of the muscle until a paresthesia is obtained. 4) Paresthesia is usually elicited while inserting the needle tip about 1~2 em in depth. If so, the local anesthetic solution is injected after careful aspiration. 5) If no paresthesia is elicited, the needle is withdrawn and redirected in an attempt to elicit paresthesia. 6) If, after several attempts, no paresthesia is obtained, the local anesthetic solution is injected into the perivascular sheath after confirming that the artery is not punctured. 7) Immediately after starting surgery, Valium is injected for sedation by the intravenous route in almost all cases. The age distribution of the cases was from 11 to 80 years. Sex distribution was 476 males and 49 females (Table 1). Operative procedures consisted of 103 open reductions, 114 skin grafts combined with spinal anesthesia in 14, 87 debridements, 75 repairs, i.e. tendon (41), nerve(32), and artery (2), 58 corrections of abnormalities, 27 amputations above the elbow (5), below the elbow (3) and fingers (17), 20 primary closures, 18 incisions and curettages, 2 replantations of cut fingers. respectively (Table 2). Paresthesia was obtained in all cases. Onset of analgesia occured within 5 minutes, starting in the deltoid region in almost all cases. Complete anesthesia of the entire arm appeared within 10 minutes but was delayed 15 to 20 minutes in 5 cases and failed in one case. Thus, our success rate was nearly 100%. The duration of anesthesia after a single injection ranged from $3\frac{1}{2}$ to $4\frac{1}{2}$, hours in 94% of the cases. The operative time ranged from 0.5 to 4 hours in 92.4% of the cases(Table 3). Repeat blocks were carried out in 33 cases when operative times which were more than 4 hours in 22 cases and the others were completed within 4 hours (Table 4). Two patients of the 33 cases, who received microvasular surgery were injected twice with 2% lidocaine 20 ml for a total of $13\frac{1}{2}$ hours. The 157 patients who received surgery on the forearms or hands had pneumatic tourniquets (250 torrs) applied without tourniquet pain. There was no pneumothorax, hematoma or phrenic nerve paralysis in any of the unilateral and 27 bilateral blocks, but there was hoarseness in two, Horner's syndrome in 11 and shivering in 7 cases. No general seizures or other side effects were observed. By 20ml of 60% urcgratin study, we confirm ed the position of the needle tip to be in a safer position when the arm is in hyperabduction than when it is in adduction. And also that the humoral head caused some obstraction of the distal flow of the dye, indicating that less local anesthetic solution would be needed for satisfactory anesthesia. (Fig. 3,4).

  • PDF

Dose distribution at junctional area abutting X-ray and electron fields (X-선과 전자선의 인접조사에서 접합 조사면에서의 선량분포)

  • Yang, Kwang-Mo
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.16 no.1
    • /
    • pp.91-99
    • /
    • 2004
  • Purpose : For the head and neck radiotherapy, abutting photon field with electron field is frequently used for the irradiation of posterior neck when tolerable dose on spinal cord has been reached. Materials and methods : Using 6 MV X-ray and 9 MeV electron beams of Clinac1800(Varian, USA) linear accelerator, we performed film dosimetry by the X-OMAT V film of Kodak in solid water phantom according to depths(0 cm, 1.5 cm, 3 cm, 5 cm). 6 MV X-ray and 9 MeV electron(1Gy) were exposes to 8cm depth and surface(SSD 100cm) of phantom. The dose distribution to the junction line between photon($10cm{\times}10cm$ field with block) and electron($15cm{\times}15cm$ field with block) fields was also measured according to depths(0 cm, 0.5 1.5 cm, 3 cm, 5 cm). Results : At the junction line between photon and electron fields, the hot spot was developed on the side of the photon field and a cold spot was developed on that of the electron field. The hot spot in the photon side was developed at depth 1.5 cm with 7 mm width. The maximum dose of hot spot was increased to $6\%$ of reference doses in the photon field. The cold spot in the electron side was developed at all measured depths(0.5 cm-3 cm) with 1-12.5 mm widths. The decreased dose in the cold spot was $4.5-30\%$ of reference dose in the electron field. Conclusion : When we make use of abutting photon field with electron field for the treatment of head and neck cancer we should consider the hot and cold dose area in the junction of photon and electron field according to location of tumor.

  • PDF

A Study of Decrease Exposure Dose for the Radiotechnologist in PET/CT (PET-CT 검사에서 방사선 종사자 피폭선량 저감에 대한 방안 연구)

  • Kim, Bit-Na;Cho, Suk Won;Lee, Juyoung;Lyu, Kwang Yeul;Park, Hoon-Hee
    • Journal of radiological science and technology
    • /
    • v.38 no.1
    • /
    • pp.23-30
    • /
    • 2015
  • Positron emission tomography scan has been growing diagnostic equipment in the development of medical imaging system. Compare to 99mTc emitting 140 keV, Positron emission radionuclide emits 511 keV gamma rays. Because of this high energy, it needs to reduce radioactive emitting from patients for radio technologist. We searched the external dose rates by changing distance from patients and measure the external dose rates when we used shielder investigate change external dose rates. In this study, the external dose distribution were analyzed in order to help managing radiation protection of radio technologists. Ten patients were searched (mean age: $47.7{\pm}6.6$, mean height: $165.5{\pm}3.8cm$, mean weight: $65.9{\pm}1.4kg$). Radiation was measured on the location of head, chest, abdomen, knees and toes at the distance of 10, 50, 100, 150, and 200 cm, respectively. Then, all the procedure was given with a portable radiation shielding on the location of head, chest, and abdomen at the distance of 100, 150, and 200 cm and transmittance was calculated. In 10 cm, head ($105.40{\mu}Sv/h$) was the highest and foot($15.85{\mu}Sv/h$) was the lowest. In 200 cm, head, chest, and abdomen showed similar. On head, the measured dose rates were $9.56{\mu}Sv/h$, $5.23{\mu}Sv/h$, and $3.40{\mu}Sv/h$ in 100, 150, and 200 cm, respectively. When using shielder, it shows $2.24{\mu}Sv/h$, $1.67{\mu}Sv/h$, and $1.27{\mu}Sv/h$ in 100, 150, and 200 cm on head. On chest, the measured dose rates were $8.54{\mu}Sv/h$, $4.90{\mu}Sv/h$, $3.44{\mu}Sv/h$ in 100, 150, and 200 cm, respectively. When using shielder, it shows $2.27{\mu}Sv/h$, $1.34{\mu}Sv/h$, and $1.13{\mu}Sv/h$ in 100, 150, and 200 cm on chest. On abdomen, the measured dose rates were $9.83{\mu}Sv/h$, $5.15{\mu}Sv/h$, and $3.18{\mu}Sv/h$ in 100, 150, and 200 cm, respectively. When using shielder, it shows $2.60{\mu}Sv/h$, $1.75{\mu}Sv/h$, and $1.23{\mu}Sv/h$ in 100, 150, and 200 cm on abdomen. Transmittance was increased as the distance was expanded. As the distance was further, the radiation dose were reduced. When using shielder, the dose were reduced as one-forth of without shielder. The Radio technologists are exposed of radioactivity and there were limitations on reducing the distance with Therefore, the proper shielding will be able to decrease radiation dose to the technologists.