• 제목/요약/키워드: Head CT

검색결과 576건 처리시간 0.031초

An Unusual Case of Cerebral Penetrating Injury by a Driven Bone Fragment Secondary to Blunt Head Trauma

  • Lee, Jae-Il;Ko, Jun-Kyeung;Cha, Seung-Heon;Han, In-Ho
    • Journal of Korean Neurosurgical Society
    • /
    • 제50권6호
    • /
    • pp.532-534
    • /
    • 2011
  • Temple trauma that appears initially localized to the skin might possess intracranial complications. Early diagnosis and management of such complications are important, to avoid neurologic sequelae. Non-penetrating head injuries with intracranial hemorrhage caused by a driven bone fragment are extremely rare. A 53-year-old male was referred to our hospital because of intracerebral hemorrhage. He was a mechanic and one day before admission to a local clinic, tip of metallic rod hit his right temple while cutting the rod. Initial brain computed tomography (CT) and magnetic resonance imaging demonstrated scanty subdural hematoma at right temporal lobe and left falx and intracerebral hematoma at both frontal lobes. Facial CT with 3-D reconstruction images showed a small bony defect at the right sphenoid bone's greater wing and a small bone fragment at the left frontal lobe, crossing the falx. We present the unusual case of a temple trauma patient in whom a sphenoid bone fragment migrated from its origin upward, to the contralateral frontal lobe, producing hematoma along its trajectory.

단면 윤곽선을 기반으로 한 두부표변의 재구성 (Reconstruction of Head Surface based on Cross Sectional Contours)

  • 한영환;성현경;홍승홍
    • 대한의용생체공학회:의공학회지
    • /
    • 제18권4호
    • /
    • pp.365-373
    • /
    • 1997
  • 본 논문에는 표면 형태만을 고려한 방법으로 다수의 단면 영상 데이터로부터, 관심있는 기관의 외부 표면을 패치(patch)에 의한 방법으로 재구성하여 삼차원적으로 표시하는 것을 목적으로 한다. 이를 위해 본 논문에서는 표면을 형성하기 위한 특징점을 추출하기 위하여 제거법에 의한 특징점 추출이라는 알고리즘을 제안하여 사용하였으며, 표면을 재구성하기 윟나 과정에서 두 단면의 영상의 특징점 사이의 최소 거리를 비용 함수로 사용하는 방법을 제안하였다. 제안한 알고리즘의 효용성을 확인하기 위하여 두부에 대한 이차원 CT 영상을 사용하여 실험을 실시하고 다른 방법과 비교하여 보았다.

  • PDF

CT 영상의 화질개선을 위한 이중트리복합웨이블릿의 적용 (Application of Dual Tree Complex Wavelet for Performance Improvement of CT Images)

  • 최석윤
    • 한국방사선학회논문지
    • /
    • 제13권7호
    • /
    • pp.941-946
    • /
    • 2019
  • 환자의 진단 및 치료를 결정할 때 전산화단층촬영 (computed tomography; CT)은 우수한 해부학 정보를 제공하기 때문에 진단에 큰 도움이 되어 있다. 그에 따른 사용빈도가 증가하고 있으며, 활용 및 응용범위도 확대되어가는 추세이다. 저관전압을 사용해서 CT 검사를 하면 노이즈가 증가한다. 기존의 여러 연구에서는 영상재구성법에 대한 노출조건을 조절하는 방법 등을 시도해서 최적의 화질을 찾는 방법을 찾고 있으나 근본적 문제해결은 되지 못한다. 입력 영상의 신호를 유지하고 노이즈만을 최대한 제거하기 위해서 이중 트리웨이블릿 알고리즘을 적용하였다. 실험결과 100kVp, 회전시간 0.5sec의 영상에서 complex oriented 2d 방을 사용 할 경우 노이즈는 8.53에서 4.51로 줄어들었다. 본 연구를 통해서 저관전압 두부 CT에서 발생하는 높은 수준의 노이즈를 최적의 노이즈제거 알고리즘으로 노이즈를 제거하고 환자선 량을 낮출 수 있었다. 본 연구결과를 임상에서 사용 시 저선량의 CT 사용이 가능하고 환자 피폭을 줄일 것으로 판단한다.

Feasibility of Improving the Accuracy of Dose Calculation Using Hybrid Computed Tomography Images: A Phantom Study

  • Jeon, Hosang;Kim, Dong Woon;Joo, Ji Hyeon;Ki, Yongkan;Kim, Wontaek;Park, Dahl;Nam, Jiho;Kim, Dong Hyeon
    • 한국의학물리학회지:의학물리
    • /
    • 제32권1호
    • /
    • pp.18-24
    • /
    • 2021
  • Purpose: Kilovoltage computed tomography (kV-CT) is essential for radiation treatment planning. However, kV-CT images are significantly distorted by artifacts when a metallic prosthesis is present in the patient's body. Thus, the accuracies of target delineation and treatment dose calculation are inevitably lowered. We evaluated the accuracy of the calculated doses using an image restoration method with hybrid CT, which was introduced in our previous study. Methods: A cylindrical phantom containing four metals, namely, silver, copper, tin, and tungsten, was scanned using kV-CT and megavoltage CT to produce hybrid CT images. We created six verification plans for three head and neck patients on kV-CT and hybrid CT images of the phantom and calculated their doses. The actual doses were measured with film patches during beam delivery using tomotherapy. We used the gamma evaluation method to compare dose distribution between kV-CT and hybrid CT with three gamma criteria, namely, 3%/3 mm, 2%/2 mm, and 1%/1 mm. Results: The gamma pass rates decreased as the gamma criteria were strengthened, and the pass rate of hybrid CT was higher than that of kV-CT in all cases. When the 1%/1 mm criterion was used, the difference in gamma pass rates between them was up to 13%p. Conclusions: According to our findings, we expect that the use of hybrid CT can be a suitable approach to avoid the effect of severe metal artifacts on the accuracy of dose calculation and contouring.

후인두 종물로 나타난 갑상선 유두상 암종 1예 (Thyroid Papillary Carcinoma Presenting as Posterior Pharyngeal Mass : A Case Report)

  • 강재호;양시창;김춘동;김승우
    • 대한두경부종양학회지
    • /
    • 제26권2호
    • /
    • pp.221-224
    • /
    • 2010
  • Papillary thyroid carcinoma frequently invades the lymph node, trachea, esophagus and perithyroid tissue. However, direct extension to posterior pharyngeal area is known to be rare. A 64-year-old male was referred to our clinic presenting as posterior pharyngeal mass during gastrofiberscopy. The neck CT scan showed soft tissue mass in retropharynx and lymph node in right level III with calcifications. We performed the total thyroidectomy with selective(level II, III, IV) and anterior compartment neck dissection. In operative findings, the right thyroid mass were connected to the retropharynx through the posterior portion of inferior constrictor muscle. Histopathologic findings revealed the papillary thyroid carcinoma extended to retropharynx. We report a unique case with a literature review.

소아에서 발생한 연구개 점액표피양 종양 1례 (Mucoepidermoid Carcinoma of the Soft Palate in a Child)

  • 정훈;은영규;권기환
    • 대한두경부종양학회지
    • /
    • 제24권2호
    • /
    • pp.207-210
    • /
    • 2008
  • The purpose of this paper is to review our experience with mucoepidermoid carcinoma(MEC), a rare tumour in minor salivary glands, in a paediatric patients. 15-year-old boy was noted to have a irregular round mass appearing atthe soft palate just to the right of the mid-line. A computed tomographic(CT) scan showed a palatal mass limited to soft palate with no bony erosion. The lesion was curetted and debulked. Pathology was reported as an intermediate-grade mucoepidermoid carcinoma, and the patient was considered to radiation therapy institution for further treatment. To date, patients remain free of disease. Wide local excision is the treatment of choice for low to intermediate grade MEC of the minor salivary glands in paediatric patients.

3D Overhead Modeling Using Depth Sensor

  • Song, Eungyeol;Lee, Sangyoun
    • Journal of International Society for Simulation Surgery
    • /
    • 제1권2호
    • /
    • pp.83-86
    • /
    • 2014
  • Purpose This paper was purposed to suggest the method to produce the supportive helmet (head correction) for the infants who are suffering from plagiocephaly and to evaluate the level of transformation through 3D model. Method Either of CT or X-ray restored images has been used in making the supportive helmet (Head correction) in general, but these methods of measuring have problems in cost and safety. 3D surface measurement technology was suggested to solve such matters. Results It was to design the transformed model of the head within 0.7cm in average by scanning the surface of head and performing 3D restoration with marching cube and the changing rate of the head was compared in numerical data with 3D model. Conclusion The suggested methods displayed the better performance than the conventional method in respect of the speed and cost.

콘빔형 전산화단층영상을 이용한 자연치 치간거리의 평가 (Evaluation of interdental distance of natural teeth with cone-beam computerized tomography)

  • 오상천;공현준;이완
    • 구강회복응용과학지
    • /
    • 제33권4호
    • /
    • pp.278-283
    • /
    • 2017
  • 목적: 본 연구 목적은 이상적인 임플란트 근원심적 식립 위치 결정에 필요한 정보를 제공하기 위해서 콘빔형 전산화단층영상(cone-beam CT)을 사용하여 건강한 자연치열에서 백악-법랑 경계부와 치조골 흡수를 가정한 그 하방 2 mm에서 전치, 소구치, 대구치의 치간거리를 평가하는 것이다. 연구 재료 및 방법: 원광대학교 치과대학병원에서 cone-beam CT를 촬영한 건강한 치열의 200명 환자를 선정하였다. Cone-beam CT 이미지를 DICOM (digital imaging and communication in medicine) 파일로 전환하여, 3차원 영상으로 재구성하였고, cone-beam CT 이미지를 표준화하기 위하여 head reorientation을 시행한 후, 전용 소프트웨어를 이용해 재구성된 파노라마 이미지를 얻었다. 모든 계측은 3명의 치과의사에 의해 최적화된 파노라마 이미지 상에서 시행되었다. 결과: 백악-법랑 경계부에서 상악 평균 치간거리는 전치 1.84 mm, 소구치 2.07 mm, 대구치 2.08 mm 그리고 하악은 전치 1.55 mm, 소구치 2.20 mm, 대구치 2.36 mm였다. 백악-법랑 경계부 하방 2 mm에서 상악 평균 치간거리는 전치 2.19 mm, 소구치 2.51 mm, 대구치 2.60 mm 그리고 하악은 전치 1.86 mm, 소구치 2.53 mm, 대구치 3.01 mm였다. 결론: 자연치열에서 치간거리는 전치부보다는 구치부에서 더 컸으며, 백악-법랑 경계부보다 그 하방 2 mm에서 더 크게 나타났다. 전 치열에서 가장 좁은 곳은 하악 전치, 가장 넓은 곳은 하악 대구치였다.

두부 CT 검사 시 검사 모드에 따른 화질 및 선량평가 (Image Quality and Dose Assessment According to Examination Mode during Head CT Examination)

  • 강헌효;최우전;김동현
    • 한국방사선학회논문지
    • /
    • 제15권4호
    • /
    • pp.437-444
    • /
    • 2021
  • 두경부 CT 검사시 팬텀을 이용하여 Helical mode, High Pitch Mode, Volume Axial Mode 사용하여 획득한 CT 영상으로부터 환자의 피폭선량과 각 영상의 화질을 비교 및 분석하여 Volume Axial Mode의 유용성을 평가해보고자 한다. 두경부 CT 검사 시 각 mode에 따른 70 kVp, 80 kVp, 100 kVp 관전압에 따라 검사를 시행하였다. 사용 장비로는 GE사의 Revolution(GE Healthcare, Wisconsin USA) 모델과 iMED X-ray Phantom을 이용하였다. 검사 Mode에따른 kVp별로 얻어진 영상을 이용하여 팬텀의 피폭선량을 비교하였으며, 각 영상에 ROI를 설정해 신호대 잡음비와 대조도대 잡음비를 산출하여 영상의 화질을 비교하였다. Volume Axial Mode를 사용하여 검사하였을 때 팬텀의 피폭선량이 Helical에 비해 17.12% 낮게, High Pitch에 비해 5.35% 낮게 측정되었고, 신호대 잡음비와 대조도대 잡음비가 향상되었다. Volume Axial Mode는 고속 회전 스캐너를 이용하여 테이블의 이동이 없이 조사시간을 줄이고, High Pitch Mode와 Helical Mode를 사용했을 때 보다 팬텀의 0.28초의 단시간에 영상을 획득하여 피폭선량이 감소하고 영상의 화질 또한 향상되는 유용한 검사라 할 수 있다. 또, 몸이 불편한 환자의 촬영이나 긴급환자의 CT 촬영에 있어서 Volume Axial Mode의 빠른 검사시간은 최대의 장점이라고 볼 수 있다.