• Title/Summary/Keyword: Hazards detection

Search Result 133, Processing Time 0.02 seconds

Site Monitoring System of Earthquake, Fault and Slope for Nuclear Power Plant Sites (원자력발전소의 부지감시시스템의 운영과 활용)

  • Park, Donghee;Cho, Sung-il;Lee, Yong Hee;Choi, Weon Hack;Lee, Dong Hun;Kim, Hak-sung
    • Economic and Environmental Geology
    • /
    • v.51 no.2
    • /
    • pp.185-201
    • /
    • 2018
  • Nuclear power plants(NPP) are constructed and operated to ensure safety against natural disasters and man-made disasters in all processes including site selection, site survey, design, construction, and operation. This paper will introduce a series of efforts conducted in Korea Hydro and Nuclear Power Co. Ltd., to assure the safety of nuclear power plant against earthquakes and other natural hazards. In particular, the present status of the earthquake, fault, and slope safety monitoring system for nuclear power plants is introduced. A earthquake observatory network for the NPP sites has been built up for nuclear safety and providing adequate seismic design standards for NPP sites by monitoring seismicity in and around NPPs since 1999. The Eupcheon Fault Monitoring System, composed of a strainmeter, seismometer, creepmeter, Global Positioning System, and groundwater meter, was installed to assess the safety of the Wolsung Nuclear Power Plant against earthquakes by monitoring the short- and long-term behavioral characteristics of the Eupcheon fault. Through the analysis of measured data, it was verified that the Eupcheon fault is a relatively stable fault that is not affected by earthquakes occurring around the southeastern part of the Korean peninsula. In addition, it was confirmed that the fault monitoring system could be very useful for seismic safety analysis and earthquake prediction study on the fault. K-SLOPE System for systematic slope monitoring was successfully developed for monitoring of the slope at nuclear power plants. Several kinds of monitoring devices including an inclinometer, tiltmeter, tension-wire, and precipitation gauge were installed on the NPP slope. A macro deformation analysis using terrestrial LiDAR (Light Detection And Ranging) was performed for overall slope deformation evaluation.

Epidemiological Studies on Giardia Infection Associated with environmental Pollution (Giardia에 의한 환경오염(環境汚染)과 감염(感染)에 관한 역학적(疫學的) 연구(硏究))

  • Lee, Keun-Tae;Kim, Seok-Chan;Song, Jong-Sool;Chung, Pyung-Rim
    • Journal of agricultural medicine and community health
    • /
    • v.9 no.1
    • /
    • pp.56-66
    • /
    • 1984
  • Giardia lamblia is a pathogenic flagellate causing intestinal disorders such as diarrhea, abdominal pain and malabsorption of nutrients. Giardia is mainly infected by the ingestion of contaminated foods per os. Craun (1979) has recently reported that mass infection of this flagellate through the contaminated water supply systems is one of public health hazards. Also, so-called traveller's diarrhea is sometimes caused by Giardia infection (CDC, U.S.A., 1971). However, a few epidemiological studies figuring out the mode of infection or control measures of Giardia infection has been done so far in Korea. The present study was aimed to know the prevalence of Giardia infection in several Korean populations, detectability of this flagellate in water systems and the viability of the cysts against sewages and disinfectants applying to drinking water. In the present study, 388 stool specimens from orphanage children in Chun-joo, Chung-joo, On-yang and Chun-an areas and 538 stool specimens from inhabitants in Woo-do, In-chon, and Chun-joo were examined by formalin-ether concentration technique to detect out Giardia cysts. On the other hand, water samples from 14 sites of Han River and its tributaries were collected in May through July, 1984. Fifty liter of water sample in each sampling site was then filtered through water filtering system deviced by U.S. Environmental Proutection Agency and the sediments rinsed out from the thread rolls, a part of water filtering system, were examined to detect out the Giardia cysts. In order to observe the viability of Giardia cysts in the sewage samples, the cysts were treated in it at $4^{\circ}C$ or $25^{\circ}C$ for 7 through 28 days. For this purpose, the cysts were also exposed to various concentrations of disinfectants such as chlorine, iodine and ozone gas for proper time intervals. After treatment, the viability test of the Giardia cysts were carried out by method of Rice and Schaefer (1981) with minor modification. The results obtained in this study were as follows : 1) The detection rates of G lamblia cysts in the stool specimens were 18.3% in orphans and 4.3% in general examinees. 2) The prevalences of Giardia Infection were higher in the young age groups than in-adults. The highest positive rate was 18.4% in the age group less than 10. 3) Of 14 water specimens sampled from Han River system and its tributaries around the Seoul area, the Giardia cysts were detected from 4 samples, and no cyst was found in the water supply systems. 4) The cysts treated in the sewage survived for 28 days at $4^{\circ}C$ and for 13 days at $25^{\circ}C$. 5) The cysts were completely destroyed within 60 minutes by exposure to 8 mg/l of residual chlorine at 4g and within 30 minutes by exposure to the same concentration of chlorine at $25^{\circ}C$. 6) The cysts were all dead when exposed to 1 mg/1 of iodine for 60 minutes at $4^{\circ}C$ or $25^{\circ}C$. 7) The cysts were destroyed after 10 minute exposure in 0.15 mg to 0.25mg of residual ozone gas per liter. Summarizing the above results, it is considered that Giardia infection is regarded as water-borne disease and the cysts are able to be controlled by the application with the disinfectants in the water supply systems.

  • PDF

Microbiological Hazard Analysis for HACCP System Application to Non Heat-Frozen Carrot Juice (비가열냉동 당근주스의 HACCP 시스템 적용을 위한 미생물학적 위해 분석)

  • Lee, Ung-Soo;Kwon, Sang-Chul
    • Journal of Food Hygiene and Safety
    • /
    • v.29 no.2
    • /
    • pp.79-84
    • /
    • 2014
  • This study has been performed for about 270 days at analyzing biologically hazardous factors in order to develop HACCP system for the non heat-frozen carrot juice. A process chart was prepared by manufacturing process of raw agricultural products of non heat-frozen carrot juice, which was contained water and packing material, storage, washing, cutting, extraction of the juice, internal packing, metal detection, external packing, storage and consignment (delivery). As a result of measuring Coliform group, Staphylococcus aureus, Salmonella spp., Bacillus cereus, Listeria Monocytogenes, Enterohemorrhagic E. coli before and after washing raw carrot, Standard plate count was $4.7{\times}10^4CFU/g$ before washing but it was $1.2{\times}10^2CFU/g$ detected after washing. As a result of testing airborne bacteria (Standard plate count, Coliform group, Yeast and Fungal) depending on each workplace, number of microorganism of in packaging room, shower room and juice extraction room was detected to be 10 CFU/Plate, 60 CFU/Plate, 20 CFU/Plate, respectively. As a result of testing palm condition of workers, as number of Standard plate count, Coliform group and Staphylococcus aureus was represented to be high as $6{\times}10^4CFU/cm^2$, $0CFU/cm^2$ and $0CFU/cm^2$, respectively, an education and training for individual sanitation control was considered to be required. As a result of inspecting surface pollution level of manufacturing facility and devices, Coliform group was not detected in all the specimen but Standard plate count was most dominantly detected in scouring kier, scouring kier tray, cooling tank, grinding extractor, storage tank and packaging machine-nozzle as $8.00{\times}10CFU/cm^2$, $3.0{\times}10CFU/cm^2$, $4.3{\times}10^2CFU/cm^2$, $7.5{\times}10^2CFU/cm^2$, $6.0{\times}10CFU/cm^2$, $8.5{\times}10^2CFU/cm^2$ respectively. As a result of analyzing above hazardous factors, processing process of ultraviolet ray sterilizing where pathogenic bacteria may be prevented, reduced or removed is required to be controlled by CCP-B (Biological) and critical level (critical control point) was set at flow speed is 4L/min. Therefore, it is considered that thorough HACCP control plan including control criteria (point) of seasoning fluid processing process, countermeasures in case of its deviation, its verification method, education/training and record control would be required.