• Title/Summary/Keyword: Hazardous chemical

Search Result 574, Processing Time 0.032 seconds

A Mobile Application for Navigating the Optimal Escape Route in Accidents and Emergency Situations (모바일 어플리케이션을 이용한 재난상황 발생 시 최적 대피경로 설정)

  • Cho, Sung Hyun;Joo, Ki Don;Kang, Hoon;Park, Kyo Shik;Shin, Dong Il
    • Korean Journal of Hazardous Materials
    • /
    • v.3 no.1
    • /
    • pp.28-36
    • /
    • 2015
  • In early 2011, the Fukushima nuclear power plant had greater damage due to earthquake in Japan, and the awareness of safety has increased. In particular, special response systems should be required to handle disaster situations in plant sites which are likely to occur for large disasters. In this study, a program is designed to set up optimum escape routes, by a smart phone application, when a disaster situation occurs. This program could get information of the cumulative damage from sensors and display the escape route of the smallest damage in real-time on the screen. Utilizing our application in real-time evacuation has advantage in reducing cumulative damage. The optimal evacuation route, focusing on horizontal path, is calculated based on getting the data of fire, detected radioactivity and hazardous gas. Thus, using our application provides information of optimal evacuation to people who even can not hear sensor alarms or do not know geography, without requiring additional costs except fixed sensors or server network deployment cost. As a result, being informed of real-time escape route, the user could behave rapidly with suitable response to individual situation resulting in improved evacuation than simply reacting to existing warning alarms.

Chemical Risk Factors for Children's Health and Research Strategy (어린이 건강관련 유해물질 연구방향)

  • Lee, Hyo-Min;Jung, Ki-Hwa
    • Journal of Food Hygiene and Safety
    • /
    • v.23 no.3
    • /
    • pp.276-283
    • /
    • 2008
  • To provide the research strategy for protection of children's health from hazardous chemical, we reviewed the hazardous chemicals can be exposed through maternity, children's life style and living environment. Recently, diseases related with children's living condition were focused as asthma, atopy, childhood developmental disability, congenital malformations and obesity. Children can be exposed to hazardous chemicals through an ambient air, water, soil, food, toys and other factors such as floor dust. Also children's health was deeply related with a wrong life style and neglectful caring by a lack of knowledge and information of harmful ones at parents and child care center's nursers. According to the previous study, the chemical risk factor of children's health were identified as inorganic arsenic, bisphenol A, 2,4-D, dichlorvos, methylmercury, PCBs, pesticide, phthalates, PFOA/PFOS, vinyl chloride, et al. Domestic studies for identification of causality between children exposure to chemicals and resulted hazardous effects were not implemented. The confirmation of chemical risk factors through simultaneously performing toxicological analysis, human effect study, environmental/human monitoring, and risk assessment is needed for good risk management. And also, inter-agency collaboration and sharing information can support confirming scientific evidence and good decision making.

A Study on a Safety System for Preventing Atmospheric Diffusion of Hazardous and Noxious Chemicals in Dike (방유벽 내 위험·유해화학물질 대기 확산 방지를 위한 안전시스템 연구)

  • Lee, Deok-Jae;Song, Chang-Geun
    • Fire Science and Engineering
    • /
    • v.33 no.4
    • /
    • pp.97-104
    • /
    • 2019
  • Behind the growth of the chemical industry which is a cornerstone of the Korean economy, dozens of hazardous and noxious chemical accidents occur every year, resulting in enormous casualties and environmental damages. Many cases among chemical accidents are caused by the carelessness of workers in handling facilities such as hydrochloric acid and hydrofluoric acid, and the aging of handling facilities. In order to mitigate the damage by such chemical accidents, a safety system for preventing atmospheric diffusion of hazardous and xoxious chemicals in dike was proposed. The atmospheric diffusion prevention safety system consists of leak detection phase, alarm and measurement phase, suppression and blocking phase. Through the proposed the atmospheric diffusion prevention safety system, the need for 2nd chemical accident prevention such as atmospheric diffusion in dike can be posed.

Study on the Prioritization of Management for Each Toxic Chemical Substance in Ansan Smart Hub. (안산스마트허브 유해화학물질별 관리우선순위 선정에 관한 연구)

  • Choi, Bong Seok;Sa, Jae-Hwan;Kim, Min Wook;Jeon, Eui Chan
    • Korean Journal of Hazardous Materials
    • /
    • v.2 no.1
    • /
    • pp.12-17
    • /
    • 2014
  • With a rapid growth of domestic industry in korea, now about 25,000 kinds of chemicals are being distributed, and it has been known that just about 15% of them has toxic substances. Recently, South Koreans have an anxiety about the stability and accidents of chemicals because chemical accidents like Gumi hydrofluoric acid accident have occurred. The U.S. has adopted the systems like EPCRA (Emergency Planning and Community Right-to-Know Act), TRI (Toxic Release Inventory) and TSCA (Toxic Substances Control Act), and is also managing the hazardous chemicals by providing the information about them to its people and site workers. Japan's Ministry of Health, Labor and Welfare also has adopted J-CHECK system and is implementing it to let Japanese people know the information of safety of chemicals about REACH. However, the Korean government has a difficult situation to mediate the different idea with the Korean industry to make lower statute of Pre-legislation registration & evaluation of chemicals that will be implemented and Chemical Material Control Association that is being implemented. Especially city and country areas located in the industrial areas need political improvement focusing on vulnerable area through the check about current situation of hazardous chemicals of jurisdiction and management method, but the information about the management situation of small scale work places is insufficient. Therefore this study set up the urgent management area in Ansan Smart Hub through NFPA code according to the types of accident and dander characteristics of each chemical being used in the companies that have less than 50 workers and deal with chemicals located in Ansan Smart Hub in Gyeonggi-do.

A Study on the Emission Characteristics of Odorous Substances in Korea (국내 화학물질 배출량 특성에 관한 연구: 악취물질 중심으로)

  • Im, JiYoung;Jeon, DaYoung;Kim, BoKyeong;Ryu, JiSung;Yoon, DaeSik;Lee, ChungSoo
    • Journal of Environmental Health Sciences
    • /
    • v.45 no.5
    • /
    • pp.465-473
    • /
    • 2019
  • Objectives: A variety of industries handling hazardous chemicals emit odorous substances. Based on the emission characteristics of major odor substances from the results of hazardous chemical substance emissions, we will define basic data for improving the management methods of odorous substances. Methods: A survey of hazardous pollutant emissions for 2010-2016 was conducted through the Pollutant Release and Transfer Register homepage. Eight kinds of designated odor substances (ammonia, hydrogen sulfide, dimethyl disulfide, acetaldehyde, styrene, toluene, xylene, methyl ethyl ketone) provided the study subjects. The status of chemical accidents for the target substances was analyzed using the Chemistry Safety Clearing-house system. Results: From 2010 to 2016, it was found that more than 30% of businesses that emitted odorous substances accounted for more than 50% of the total emissions of the eight substances. Emissions of xylene, toluene, methyl ethyl ketone, and ammonia were found, in that order, and they made up more than 90% of the total emitted. By region, about 70% of odorous substances were emitted in the top-four regions: Gyeongsangnam-do Province, Ulsan, Gyeonggi-do Province, and Jeollanam-do Province. Conclusion: Recently, the amount of chemical emissions has been continuously increasing, including those that can cause odor. Odorous substances can be a serious risk to the lives of local residents. Systematic research is needed for the health protection of residents.

The Comparison of Volatile Organic Compounds (VOCs) Analysis and Tradescantia Micronucleus (Trad-MCN) Bioassay for Evaluation of Hazardous Materials in Chemical Workplace Field (화학공장 실내 작업장에서의 유해물질 평가를 위한 VOC 분석법과 자주달개비 미세핵 분석법의 비교)

  • Heo, Gwi Suk;Lee, Jae Hwan;Shin, Hae Shik;Kim, Jin Kyu;Lee, Young Yup;Lee, Dai Woon;Lee, Jin Hong
    • Analytical Science and Technology
    • /
    • v.16 no.1
    • /
    • pp.1-11
    • /
    • 2003
  • This research examined the presence of hazardous materials in chemical workplace field using an integrated chemical/biological monitoring. Chemical workplace field air for volatile organic compounds (VOCs) analysis was collected using a collection tube packed with Tena.x TA adsorbent 400 mg. Workplace field air samples were analyzed by gas chromatography/mass spectrometry (GC/MS). Simultaneously, Tradescantia BNL 4430 clone was exposed in situ to monitor hazardous materials in chemical workplace field. GC/MS analysis showed the presence of various VOCs such as trichloroethylene, toluene, ethylbenzene, (m,p,o)-xylenes, styrene, 1,3,5-trimethylbenzene, and 1,2,4-trimethylbenzene. The results showed that in situ monitoring of VOCs with the Tradescantia-micronucleus (Trad-MCN) assay gave positive results in chemical workplace field and negative response at outdoor air. In conclusion, inhalation of these field air by workers may affect chronic demage to their health by inducing micronuclei formation in Tradescantia pollen mother cells. The combination of chemical/biological monitoring is very effective to evaluate hazardous materials in workplace field and can be alternatively used for screening hazardous materials.

A Study on the Effect of Damages on the Conditions of Dike in the Leakage of Hydrochloric Acid Storage Tank (염산 저장탱크 누출 시 방류벽 조건에 따른 피해영향 연구)

  • Kang, Jungchun;Kim, Seungha;Kim, KyuHwan;Kim, YeonSoo;Kwon, Donguk
    • Korean Journal of Hazardous Materials
    • /
    • v.6 no.2
    • /
    • pp.7-12
    • /
    • 2018
  • Hydrochloric acid is a highly corrosive toxic substance and requires proper safety to minimize damage in case of leakage. Among the various risk-reduction facilities, the dike is a typical safety facility installed to protect the surrounding buildings and facilities by preventing the external spread of hazardous materials from the storage tank. In this study, the KORA program was used to assume leakage accident of hydrochloric acid storage tank. At this time, the extent of the damage effects of ERPG-2 were assessed for each of the three separation distance between the storage tank and the dike. The study found that the smaller the separation distance between the dike and the storage tank, the smaller the extent of damage caused by hydrochloric acid leakage, and the greater the impact of indoor conditions under the same conditions. Through this process, we are going to assist in selecting locations and installing facilities for new and existing businesses.

Analysis on the Legal Control Levels and GHS Classification Information Status for Strongly Acidic Hazardous Materials (강산성 유해화학물질의 법적관리 수준 및 GHS 분류정보 제공 실태분석 연구)

  • Lee, Kwon Seob;Jo, Ji Hoon;Park, Jin Woo;Song, Se Wook
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.23 no.4
    • /
    • pp.384-392
    • /
    • 2013
  • Objective: This study inspected incident cases, legal control levels, and GHS(Globally Harmonized System of Classification and Labeling of Chemicals) classification results of strong acids such as hydrogen fluoride, hydrogen chloride, nitric acid, and sulfuric acid, which have been responsible for many recent chemical accidents. As a result, it is deemed necessary for legal control levels of these strong acids to be revised and GHS classification be managed nation-wide. Methods: This study inspected incident cases and legal control levels for strong acids such as hydrogen fluoride, hydrogen chloride, nitric acid, and sulfuric acid. The study analyzed and compared chemical information status and GHS classification results. Results: There were 76 domestic incidents involving strongly acidic hazardous materials over the five years between 2007 and 2011. They include 37 leakage incidents(46.7%) within a workplace, 30 leakage incidents(39.5%) during transportation, and nine leakage incidents(13.8%) following an explosion. The strongly acidic materials in question are defined and controlled as toxic chemicals according to the classes of Substances Requiring Preparation for Accidents, Managed Hazardous Substance, Hazardous Chemical(corrosive) as set forth under the Enforcement Decree of the Toxic Chemicals Control Act and Rules on Occupational Safety and Health Standards of Occupational Safety and Health Act. Among them, nitric acid is solely controlled as a class 6 hazardous material, oxidizing liquid, under the Hazardous Chemicals Control Act. The classification results of the EU ECHA(European Chemicals Agency) CLP(Commission Regulation(EC) No. 790/2009 of 10 August 2009, for the purposes of its adaptation to technical and scientific progress, Regulation(EC) No 1272/2008 of the European Parliament and of the Council on classification, labeling and packaging of substances and mixtures) and NIER (National Institute of Environmental Research) are almost identical for the three chemicals, with the exception of sulfuric acid. Much of the classification information of NITE (National Institute of Technology and Evaluation) and KOSHA(Korea Occupational Safety and Health Agency, KOSHA) is the same. NIER provides 12(41.4%) out of 29 classifications, as does KOSHA.

Deterioration Characteristic of Shotcrete Immersed in Chemical Solution (화학적 침식에 의한 숏크리트의 열화특성 분석 - 단기거동)

  • Lee, Gyu-Phil;Kim, Dong-Gyou;Bae, Gyu-Jin;Shin, Hyu-Soung
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.7 no.2
    • /
    • pp.143-152
    • /
    • 2005
  • Shotcrete for support of tunnel structures may contact with groundwater. The hazardous components in groundwater may cause corrosion of shotcrete. Also, the hazardous components may deteriorate the engineering properties of shotcrete, such as compressive strength, bond strength, flexural strength and so forth. The more the effect of the hazardous components on the shotcrete may increase, the more the stability of tunnel structure may decrease. The specimens were artificially immersed in various chemical solutions including hazardous components after the specimens were made at the tunnel construction site. It was performed to analyze the effect of the hazardous components in ground water on the engineering properties of shotcrete. The uniaxial compressive strength test, XRD, SEM were conducted to evaluate the durability and corrosion of shotcrete.

  • PDF

On the Alternative Incineration Technologies for the Treatment of Hazardous Waste (유해폐기물 처리용 소각 대체기술 동향)

  • Yang, Hee-Chul;Cho, Yung-Zun;Eun, Hee-Chul;Kim, Eung-Ho
    • Korean Chemical Engineering Research
    • /
    • v.45 no.4
    • /
    • pp.319-327
    • /
    • 2007
  • Incineration has been regarded as the best developed technology available for organically hazardous waste. However, permitting and siting incinerators to treat hazardous waste such as a waste containing PCBs is very difficult due to the public concerns associated with toxic air emissions. Recently, a lot of alternatives to an incineration have been developed and these technologies have the potential of alleviating public concerns by decreasing emissions of hazardous materials such as dioxins and furans. This paper reviews currently available alternative incineration technologies for various hazardous waste streams. Various categories of non-thermal and thermal alternative incineration technologies have been evaluated in terms of their process operating condition, applicability of a waste stream and their emission of secondary waste. Detailed descriptions of operating principles of several technologies are also provided.