• Title/Summary/Keyword: Hazardous Gas

Search Result 347, Processing Time 0.021 seconds

Analysis of Air Quality and the Management Plan for Exposure to Hazardous Substances in the Garage of a Fire Station (소방청사 차고지 공기질 분석 및 유해물질 노출 관리 방안)

  • Park, Je-Seop;Han, Dong-Hun
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.30 no.4
    • /
    • pp.394-404
    • /
    • 2020
  • Objectives: The aims of this study are to derive the characteristics of diesel exhaust gas emissions generated during vehicle checking in the garage of fire stations and of the related improvement plans for proper air quality management. Methods: The researcher measured changes in the air quality inside garages according to the operating conditions of the exhaust facility and before and after vehicle checking at three fire stations. Results: During the checking of fire engines, a large volume of hazardous substances exceeding management standards were generated, and improvement of the discharge facilities was required for proper air quality management. Conclusions: It is necessary to study the hazard evaluation of firefighters' exposure to exhaust gas, to operate exhaust gas ventilation facilities, and to prepare technical standards for proper indoor air quality management.

A Case Study on Operation of Off-Gas Treatment System of Radioactive Waste Vitrification Facility (방사성폐기물 유리화설비의 배기가스 처리계통 운영 사례 연구)

  • Lee, Hye Hyun;Park, Kyu Won
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.38 no.5
    • /
    • pp.249-254
    • /
    • 2016
  • In this study, we investigated the main characteristics of off-gas generated from melting process and off-gas treatment system operation example to provide some primary data for commercial vitrification facility design. The purpose of vitrification facility operation is to treat hazardous materials in the radioactive wastes and harmful off-gas containing a variety of chemical species generated in the glass melting process. Constructing and operating vitrification facility essentially need to be licensed through safety analysis; it is very important to treat radionuclide and hazardous materials below the legal environment emissions regulation level. We must accurately understand the characteristics of off-gas and apply an appropriate off-gas treatment process accordingly. Thus, to design the appropriate off-gas treatment there must be a wide range of elements taken into account such as characteristics of waste and melter, regulation guidance of off-gas, characteristics of generated off-gas and off-gas treatment system performance assessment.

A Toxicity Evaluation for the Toxic Gases of Building Finish Materials (건축물 마감재료 연소가스에 의한 독성평가)

  • Cho, Nam-Wook;Cho, Dong-Ho;Oh, Eun-Ha
    • Journal of the Korean Applied Science and Technology
    • /
    • v.29 no.1
    • /
    • pp.129-140
    • /
    • 2012
  • Smoke toxicity is the test for the toxicity evaluation of smoke and hazardous gas, caused by combustion of building materials and finishing materials. Smoke toxicity can be evaluated by the mean incapacitation time of mice. This test result can be influenced by the health status of mice and test condition. In acute inhalation toxicity test of hazardous gas, no typical clinical findings and histopathologic abnormalities were observed. Tracheitis and bronchitis as well as acute lung inflammation around terminal bronchiole in some mouse of the highest dose group. Through this study, we established the method for inhalation toxicity test of hazardous gas as well as the SOP of inhalation toxicity test. However, in the future studies, the concentration control methods for inhalation technologies on hazardous gas will be needed to improve continuously and also further studies on other gas inhalation toxicity will be needed to conduct.

Predicting and Preventing Damages from Gas Leaks at LPG Stations (LPG 충전소의 가스누출에 따른 피해예측 및 감소방안)

  • YANG-HO YANG;HA-SUNG KONG
    • The Journal of the Convergence on Culture Technology
    • /
    • v.9 no.4
    • /
    • pp.577-585
    • /
    • 2023
  • This study applied ALOHA Program to predict the damage caused by fire and explosion predicted to occur from gas leakage at LPG stations and presented plans to prevent damages by diagramming the impact range and distance. The propane gas leakage from LPG stations causes human damage like breathing issues and property damage, including building destruction to residents in the surrounding areas. As a way to reduce this, first, the hazardous substance safety manager of the LPG station needs to check frequently whether the meters and safety valves are working properly to prevent leakage in advance. Second, the LPG stations' storage tanks should be worked by the person who received "hazardous substance safety manager training" under the provisions of the Act on the Safety Control of Hazardous Substances and has been appointed as a "hazardous substance safety manager" by the fire department. Third, LPG station's various safety device functions, such as overfill prevention devices, must be checked on a regular basis. Finally, wearing work clothes and shoes that prevent static electricity at LPG stations is highly recommended, as static can cause a fire when gas leaks.

A Study on Complementary Method for Hazardous Area Extent by IEC 60079-10-1 Edition 2.0 (IEC 60079-10-1 edition 2.0에 의한 방폭 설계 한계점 보완 방법에 관한 연구)

  • Choi, Jae-Young;Byeon, Sang-Hoon
    • Journal of the Korea Safety Management & Science
    • /
    • v.22 no.2
    • /
    • pp.73-82
    • /
    • 2020
  • IEC 60079-10-1 edition 2.0, the global standard for hazardous area classification, was newly revised in 2015. There are many differences compared to the previous edition 1.0 version, first released in 2008, so it has caused confusion in the industry. In case of edition 1.0, the hazardous area extent can be derived through the mathematical formula, but in case of edition 2.0, there was the problem that the exact hazardous area extent was not known because of the mathematical formula of the plot for applying the hazardous area extent was not presented. In this study, we converted the plot introduced in edition 2.0 to CAD format and derived the plot as the mathematical equations. Through this, we suggest the hazardous area extent formula of three states (heavy gas, diffusive, jet). As the IEC committee did not provide the mathematical formula of the hazardous area extent according to the release characteristic, it is impossible to apply the exact hazardous area extent. In this study, a mathematical approach was derived for the plot introduced in edition 2.0, which can reduce the confusion of the applying hazardous area extent.

Optimization of Gas Detector Location by Analysis of the Dispersion Model of Hazardous Chemicals (유해화학물질의 확산 모델 분석을 통한 가스감지기 위치 최적화)

  • Jeong, Taejun;Lim, Dong-Hui;Kim, Min-Seop;Lee, Jae-Geol;Yoo, Byung Tae;Ko, Jae Wook
    • Journal of the Korean Institute of Gas
    • /
    • v.26 no.2
    • /
    • pp.39-48
    • /
    • 2022
  • The domestic gas detector installation standards applied to gas detectors, which are one of the facilities that can prevent accidents such as fire, explosion, and leakage that can cause serious industrial accidents, do not take into account the behavioral characteristics of hazardous chemicals in the atmosphere. It can be seen that the technical basis is insufficient because the standard is applied. Therefore, in this study, the size of the leak hole for each facility mainly used in chemical plants and the diffusion distance according to the concentration of interest of hazardous chemicals were analyzed, and based on this, the optimal installation distance for gas detectors for each material was suggested. Using the method presented in this study, more economical and effective gas detector installation can be expected, and furthermore, it can be expected to help prevent serious industrial accidents.

Development of Preliminary Hazard Ranking System for Underground Storage Tanks Using Geographic Information System (GIS) (GIS를 이용한 지하저장탱크의 위해성 예비평가체계 개발)

  • 황상일;이상훈;이동수
    • Journal of the Korean Society of Groundwater Environment
    • /
    • v.4 no.3
    • /
    • pp.122-129
    • /
    • 1997
  • Spills or leaks of hazardous organic. compounds from underground storage tanks (USTs) are common contaminant sources of soil and groundwater. It would aid in managing USTs to assess and rank the potential environmental hazard posed by the USTs. Therefore, a preliminary hazard ranking system of USTs is developed in this study. The system is combined with GIS and consists of five steps: 1) selection of significant factors, 2) determination of the hierarchy of the factors. 3) determination of the weights, 4) calculation of the potential hazard, and 5) hazard assessment. The system is applied to the gas stations in Kwanak-gu, Seoul. The results indicate that the gas stations can be categorized in three groups as highly hazardous, less highly hazardous, and weakly hazardous. Seven gas stations belong to the highly hazardous group. Through the sensitivity analysis, four stations appear to possess high hazard potentials regardless of weights assigned to the factors. It appears that a user can make flexible application of the hazard ranking system with the user's experience and particular purposes. However, the system still needs validations against field survey data.

  • PDF

A Study on the Non-Hazardous Method for complying with the Explosion Proof Criteria of the Electrolysis (수전해설비의 전기방폭 기준 만족을 위한 비방폭화 방안에 관한 연구)

  • YongGyu, Kim;ShinTak, Han;JongBeom, Park;ByungChan, Kong;GyeJun, Park;SeungHo, Jung
    • Journal of the Korean Institute of Gas
    • /
    • v.26 no.6
    • /
    • pp.65-75
    • /
    • 2022
  • Recently, the possibility of fire and explosion due to hydrogen leakage and the resulting risk are increasing since the operating pressure of the electrolysis increases. This study performed the hazardous area classification in accordance with KS C IEC 60079-10-1 and KGS GC101 in consideration of the general operating conditions of the electrolysis. In addition, in order to achieve a To Non-hazardous, an appropriate ventilation rate was estimated to maintain a concentration of less than 25 % of the lower explosive limit. As a result, it was reviewed that the electrolysis is classified as an hazardous area when only natural ventilation is applied, and a huge amount of ventilation is required to classify it as a non-hazardous area.