• Title/Summary/Keyword: Hayashi's method

Search Result 15, Processing Time 0.022 seconds

In Sacco Ruminal Degradation Characteristics of Chemical Components in Fresh Zoysia japonica and Miscanthus sinensis Growing in Japanese Native Pasture

  • Ogura, S.;Kosako, T.;Hayashi, Y.;Dohi, H.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.14 no.1
    • /
    • pp.41-47
    • /
    • 2001
  • Ruminal degradation characteristics of dry matter (DM), neutral detergent fiber (NDF) and crude protein (CP) in fresh leaves of two Japanese native grasses (Zoysia japonica and Miscanthus sinensis) and one sown temperate grass (Dactylis glomerata) were investigated by an in sacco method in spring (mid-May), summer (mid-July) and autumn (mid-September). Japanese native grasses had higher NDF and lower CP concentrations than D. glomerata, and the CP concentration in native grasses decreased in autumn. Ruminal degradability of DM, NDF and CP was lower in native grasses than in D. glomerata (p<0.05) in all seasons. DM and NDF degradability decreased in summer for Z. japonica and D. glomerata, while it decreased in autumn for M. sinensis. CP degradability in Z. japonica was constant throughout the seasons, whereas that in M. sinensis greatly decreased in summer and autumn (p<0.05). It was concluded that Z. japonica could stably supply ruminally digestible nutrients for grazing animals in Japanese native pasture. However, the degradation characteristics of freshly chopped native grasses did not fit the exponential model of $D=a+b(1-e^{-ct})$ proposed by Ørskov and McDonald.

A METHOD OF CAPABILITY EVALUATION FOR KOREAN PADDY SOILS -Part 2. The rice yield prediction by soil fertility constituents and other characters (한국(韓國) 답토양(畓土壤)의 생산력(生産力) 평가방법에 관한 연구 -2 보(報)·비옥도(肥沃度) 구성인자(構成因子) 및 기타(其他) 특성(特性)에 의(依)한 쌀수확량(收穫量)의 추정(推定))

  • Hong, Ki-Chang;Maeng, Do-Won;Kazutake, Kyuma;Hisao, Furukawa;Suh, Yoon-Soo
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.12 no.1
    • /
    • pp.15-23
    • /
    • 1979
  • In the first paper of the series the five soil fertility factors were evaluated by means of principal component analysis and varimax method. They are interpreted as representing, 1) skeletal available phosporus status, 2) organnic matter status, 3) salt status 4) base status, and 5) free oxide status. In order to resynthesize such fragmented information for the overall soil fertility evaluation, the method of multiple regression analysis was adopted, using the five factor scores and yield data for Korean paddy soils as independent and dependent variables respectively. As test of linear models with different combinations of independent variables the results of t-test of regression coefficient were revealed that the organic matter status (FII) has no relevance to the yield of paddy and that the free oxides and salt supply has by it self only an insignificant contribution to the yield. The multiple correlation coefficient (R) revealed its multiple regression analysis was as low as 0.43. Introduction of quadratic terms to the linear model bettered the result. Thus multiple correlation coefficient (R) was increased as 0.59. Therefore, a coefficient of determination 0.35 was obtained by a quadratic model with interaction terms among the five fertility constituents. Generally we think that the fertility factor has more contribution to raise the rice yield in paddy and that the failure of yield prediction by fertility factor scores was caused by one of follows; 1) the roughness of the yield inspection, and 2) missextraction of fertility constituents. The second step in this study, assuming that the residuals by multiple regression analysis were due to factors other than soil fertility, we can now proceed to predicting the yield from the field characters with the classified fertility groups by means of Hayashi's theory of quantification No. 1. Such variables as fertility groups (FTYG), water availability (WATER), soil drainage (DRNG), climatic zone (CLIZ), surface soil's stickiness (STCKT), surface soil's dry consistence (DCNST), and surface soil's texture (FTEXT) are taken up as the explanatory variables. The quantification appears reasonable; the well to extremely well in soil drainage, very sticky of surface soil, inefficiency in water availability, coarse texture, and very hard to extremely hard dry consistence in soil are detrimental to the rice yield. The R was as high as 0.90 for the set of variables. But the given explanatory variables in this study were not quite effective in explaining rice yield. The method developed seems to be promising only if properly collected data are available. Conditions that should be satisfied in the yield inspection obtained from common cultivator for the purpose of deriving a prediction equation were put forward.

  • PDF

Syntaxonomy and Syngeography of Korean Red Pine (Pinus densiflora) Forests in Korea (한국 소나무림의 군락분류와 군락지리)

  • Chun, Young-Moon;Lee, Ho-Joon;Hayashi, Ichiroku
    • Korean Journal of Environment and Ecology
    • /
    • v.21 no.3
    • /
    • pp.257-277
    • /
    • 2007
  • We carried out a phytosociological study on pine forests in Korea with the method of Zurich-Montpellier School. We collected the data of 252 $relev{\acute{e}}s$ from 45 sites in the pine forests throughout the Korean Peninsula and its attached islands. The vegetation of the pine forests was classified into one association, three communities and seven subcommunities as follows: A: Quercus mongolica-Pinus densiflora community, A-1: Typical subcommunity, A-2: Vaccinium korean urn subcommunity, A-3 : Rhododendron micranthum subcommunity, B: Quercus serrata-Pinus densiflora community, B-1: Typical subcommunity, B-2: Juniperus rigida subcommunity, B-3: Styrax japonica subcommunity, B-4: Eurya japonica subcommunity, C: Saso-Pinetum densiflorae Yim et al. 1990, and D: Castanopsis cuspidata var. sieboldii-Pinus densiflora community. The former three communities were integrated into the Lindero-Quercion mongolicae Kim 1990 em. 1992. The Castanopsis cuspidata var. sieboldii-Pinus densiflora community remained to be studied in future to determine the association. The communities of Quercus mongolica-Pinus densiflora community was distributed throughout the montane zone in central-northern part of the Korean Peninsula. Quercus serrata-Pinus densiflora community occupied widely in the sub-montane and hilly areas in central and Southern Korean Peninsula. The association of Saso-Pinetum densiflorae was found in Cheju Island. Castanopsis cuspidata var. sieboldii-Pinus densiflora community were distributed in the warm-temperate zone including islands off the south-west coast of the Peninsula.

Experiments on the stability of the spatial autocorrelation method (SPAC) and linear array methods and on the imaginary part of the SPAC coefficients as an indicator of data quality (공간자기상관법 (SPAC)의 안정성과 선형 배열법과 자료 품질 지시자로 활용되는 SPAC 계수의 허수 성분에 대한 실험)

  • Margaryan, Sos;Yokoi, Toshiaki;Hayashi, Koichi
    • Geophysics and Geophysical Exploration
    • /
    • v.12 no.1
    • /
    • pp.121-131
    • /
    • 2009
  • In recent years, microtremor array observations have been used for estimation of shear-wave velocity structures. One of the methods is the conventional spatial autocorrelation (SPAC) method, which requires simultaneous recording at least with three or four sensors. Modified SPAC methods such as 2sSPAC, and linear array methods, allow estimating shear-wave structures by using only two sensors, but suffer from instability of the spatial autocorrelation coefficient for frequency ranges higher than 1.0 Hz. Based on microtremor measurements from four different size triangular arrays and four same-size triangular and linear arrays, we have demonstrated the stability of SPAC coefficient for the frequency range from 2 to 4 or 5 Hz. The phase velocities, obtained by fitting the SPAC coefficients to the Bessel function, are also consistent up to the frequency 5 Hz. All data were processed by the SPAC method, with the exception of the spatial averaging for the linear array cases. The arrays were deployed sequentially at different times, near a site having existing Parallel Seismic (PS) borehole logging data. We also used the imaginary part of the SPAC coefficients as a data-quality indicator. Based on perturbations of the autocorrelation spectrum (and in some cases on visual examination of the record waveforms) we divided data into so-called 'reliable' and 'unreliable' categories. We then calculated the imaginary part of the SPAC spectrum for 'reliable', 'unreliable', and complete (i.e. 'reliable' and 'unreliable' datasets combined) datasets for each array, and compared the results. In the case of insufficient azimuthal distribution of the stations (the linear array) the imaginary curve shows some instability and can therefore be regarded as an indicator of insufficient spatial averaging. However, in the case of low coherency of the wavefield the imaginary curve does not show any significant instability.

Image and Exposure Dose in Accordance with Radiation Quality on Plain Chest Radiography (흉부촬영(胸部撮影)에서 증감지(增感紙)-필름계의 선질변화(線質變化)에 따른 감도(感度)와 화질에 관(關)한 연구(硏究))

  • Kim, Jung-Min;Kim, Dong-Huan;Hayashi, Taro;Ishida, Yuji;Maeda, Mika;Sakura, Tatsuya
    • Journal of radiological science and technology
    • /
    • v.15 no.1
    • /
    • pp.65-78
    • /
    • 1992
  • Routine chest radiography is generally imaged by high voltage technique but some radiological technologists use low voltage for imaging. High voltage is usually said between $120\;kV{\sim}140\;kV$. Some RTs like using heavy filtration but others seldom like using it. However which is better for use calcium tungustate film screen system or ortho system and high contrast film or wide latitude c-type film for the exculusive use of chest radiography. We could not make a decision which is ideal method for use. In my opinion any method is not always exellent for chest radiography. In my experiments that I had at Kaken hospital in Japan last year I expect to keep the balance between image quality and diagnostic range and to reduce radiation dose for patients. My experiments are as follows. 1. We have looked into system characteristics(speed and contrast) in accordance with kVp($80{\sim}140$) and added filter($no{\sim}1/16\;VL$) in three screen film systems(BX3+CRONEX4, SRO750+MGH, SRO750+MGL). 2. We have looked into skin dose and film dose with same D=1.8 lung field density in accordance with kVp($80{\sim}140$) and added filter($no{\sim}1/16\;VL$) in three screen film systems. 3. We have compared with the evaluation between correlation of physical image quality(MTF) and optical diagnostic capability. Result are follows. 1. Speed of BX3+CRONEX4 became higher in accodance with kVp and thickness of filter but speed of ortho system was not as like regular system. Thicker filter diminished the speed over 100 kV range in SRO750+MGL. In case of SRO750+MGH speed of 1/16VL filter was looked into lower than speed of 1/4VL filter. Sensitivity of ortho system depends on tube voltage and added filter. 2. Skin dose has been detected $225\;{\mu}Gy{\sim}66\;{\mu}Gy$ in BX3+CRONEX4 from 80 kV, no filter to 140 kV, 1/16VL filter. SRO750+MGH could reduce the patient dose $1/2{\sim}1/3$ level in comparison to that of BX3+CRONEX4. 3. The higher kV was the worse MTF became the thicker filter was the worse MTF became too. MTF of BX3+CRONEX4 was detected better than MTF of SRO750+MGH but SRO750+MGH's optical detectability of small lesion in lung field came out better than that of BX3+CRONEX4. Conclusion Recently routine chest radiography is generally imaged by high voltage but it seems to be there are some questions in using of film screen combination. In high voltage chest radiography the subject contrast will come down that means latitude become wider. In this case if we select the low contrast film screen system(C or L type) the film contrast will fall down extremly and detectability of small lesion will be deteriorated. Wide latitude C, L type film has a merit of high detectability on mediastinum. Furthermore high contrast film screen system has the advantage to keep the high contrast in low density region as like mediastinum and heart shadow. Therefore in low subject contrast high voltage chest radiography we would rather choose the high contrast film screen system(H type) I think. From a view point of patient dose detectability of mediastinum and lung field. The optimum technical facter was found out 120 kV, 1/16VL filter : BX3+CRONEX4, 140 kV, 1/4VL filter : SRO750+MGH, 100 kV, 1/4VL filter : SRO750+MGL.

  • PDF