• Title/Summary/Keyword: Harmonics reduction

Search Result 263, Processing Time 0.028 seconds

The Analysis of Harmonics at a Inverter System of Low Voltage and the Methods for the Reduction (저압 인버터 시스템의 고조파 분석 및 저감 방안 연구)

  • Shin, Gang-Wook;Hong, Sung-Taek;Lee, Dong-Keun;Lee, Eun-Chun
    • Proceedings of the KIEE Conference
    • /
    • 2005.07e
    • /
    • pp.64-66
    • /
    • 2005
  • Recently, Many water treatment facilities are operated by automatic control or by remote control. These high technology control systems require more stable power supply than before. Badly most automatic control systems adopted in water treatment facilities are non-linear load which generates electrical harmonics inevitably. This study is intended to measure and analyze the electrical harmonics occurred at the chemicals control device which is inverter application circuit, and to show the Method for reduction.

  • PDF

A Study on the Analysis of Harmonics Reduction Effects Using Single-tuned Filters In a Power System Included Power Converters (전력변환장치를 포함한 전력시스템에서 동조 필터를 이용한 고조파 저감 효과의 분석에 관한 연구)

  • 최홍규;김경철;강태은;전기원
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.14 no.3
    • /
    • pp.81-87
    • /
    • 2000
  • The increasing use of non-linear loads such as power electronics draw highly distorted currents from the utility system. High harmonics currents and voltages will cause equipment damage and disturb the plant operation. The common solution to harmonics problem is to use harmonics filters. In this paper simulation results used the EDSA harmonics analysis program verifying the effects of the single-tuned filter for harmonic elimination are presented.

  • PDF

A Study on harmonics generation and reduction in Dimmer circuits (Dimmer 회로에서의 고조파 발생과 저감에 관한 연구)

  • Park, Seok-Hoon;Yu, In-Keun
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.252-254
    • /
    • 2000
  • For many years, electric utility has used sustained interruption rates as a reliability index. Today, however, many electricity consumers are adversely affected by more subtle voltage disturbances such as harmonic distortion. This paper deals with observations of events that occur in the Dimmer circuits and phase control which could affect harmonics problem to the commercial power system. In order to reduce the effect of harmonics and design filters, Solid State Relay Dimmer(SCRs or TRIACs) and Noise Filter are described, and the effects of harmonics is also analyzed. IGBT Dimmer which is appropriate method to reduce harmonics and improve efficiency is introduced.

  • PDF

Harmonics Reduction in Load control and Management system

  • Thueksathit, W.;Tipsuwanporn, V.;Hemawanit, P.;Gulpanich, S.;Srisuwan, K.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.2283-2286
    • /
    • 2003
  • This paper presents conservation of electrical energy in building with harmonics analysis and compensation which occur in electrical system. We use load controlling and management system in order to adjust load factor of system.The maximum demand limiting and controlling are used ,then the system can acquire the prediction and compare it to the maximum demand set point.The electrical signal analysis based on FFT technique. The harmonics are compensated by using harmonic filters.This system consists computer which works as controller, processor , analysis and database unit together with digital power meter in form of multidrop network through serial communication via RS-485.The load control system uses PLC to control load via serial communication RS-485. The A/D converter is used for sampling the electrical signals via parallel port of computer.The harmonic filters are controlled by a computer.The data of measurement such as voltage, current, power, power factor, total harmonic distortion, energy, etc., can be saved as database and analysis. The load factor is adjusted by limiting and controlling maximum demand. The load factor adjustment can reduce the cost of electric consumption and energy generation together with harmonics compensation in order to increase high efficiency of electrical system.

  • PDF

A Study on Current Harmonics Reduction and Unbalanced Source Voltage Compensation Using Series Active Power Filter and Parallel Passive Filter (직렬 능동전력필터와 병렬 수동필터를 이용한 고조파 전류 저감 및 불평형 전원 전압 보상에 관한 연구)

  • Oh, Jae-Hoon;Ko, Su-Hyun;Han, Yoon-Seok;Kim, Young-Seok
    • Proceedings of the KIEE Conference
    • /
    • 2001.10a
    • /
    • pp.196-199
    • /
    • 2001
  • This paper deals with current harmonics and unbalanced source voltages compensation using combined filter system. Filter system consists of a series active filter and parallel passive filters. Passive filters were a traditional method to compensate current harmonics, so those were installed in power system widely. The active filter can be a substitution to improve filtering characteristics and complement drawbacks of the passive filter. The combined system of the active power filter and passive filter can has a better compensation performances and economical goods. The series type active power filter injects compensation voltage into power system by transformers. It's compensation principle is able to applicate for voltage compensation. A new control algorithm for series active filter to compensate current harmonics and unbalanced source voltages is proposed. In the proposed algorithm, a compensation voltage for harmonic reduction is calculated directly by instantaneous reactive power theory, and a compensation voltage for unbalanced source voltage is calculated in based on a synchronous reference frame. By experiments, we show validity of proposed compensation method.

  • PDF

A Study on the Power Factor Correction and Harmonics Reduction of Capacitor Banks installed at Customers (수용가에 설치된 캐패시터 뱅크의 역률개선 및 고조파 저감에 관한 연구)

  • Kim, Kyung-Chul;Choi, Hyoung-Bumb
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.8
    • /
    • pp.12-17
    • /
    • 2008
  • Most power system loads and delivery apparatus are inductive in nature and therefore operate at a lagging power factor. Applying capacitor banks to a customer will result in a power factor correction and other benefits such as VAR support, increased voltage, reduced power losses, and reduced billing charges. Also there can be power quality problems as a result of adding capacitor banks. The most common are harmonics. This paper provides an in depth analysis on the power factor correction and harmonics reduction of capacitor bank installed at a customer. The EDSA program was used as a simulation tool for the case study.

Elimination of Low Order Harmonics in Multilevel Inverters Using Genetic Algorithm

  • Salehi, Reza;Farokhnia, Naeem;Abedi, Mehrdad;Fathi, Seyed Hamid
    • Journal of Power Electronics
    • /
    • v.11 no.2
    • /
    • pp.132-139
    • /
    • 2011
  • The selective harmonic elimination pulse width modulation (SHEPWM) switching strategy has been applied to multilevel inverters to remove low harmonics. Naturally, the related equations do not have feasible solutions for some operating points associated with the modulation index (M). However, with these infeasible points, minimizing instead of eliminating harmonics is performed. Thus, harmful harmonics such as the $5^{th}$ harmonic still remains in the output waveform. Therefore, it is proposed in this paper to ignore solving the equation associated with the highest order harmonics. A reduction in the eliminated harmonics results in an increase in the degrees of freedom. As a result, the lower order harmonics are eliminated in more operating points. A 9-level inverter is chosen as a case study. The genetic algorithm (GA) for optimization purposes is used. Simulation results verify the proposed method.

Analysis of Harmonic Effects on Substation Power System and its Countermeasure (지하철 전력계통의 고조파 영향 분석 및 그 대책에 관한 연구)

  • Song, Jin-Ho;Hwang, Yu-Mo
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.51 no.4
    • /
    • pp.210-220
    • /
    • 2002
  • We analysised the effect of harmonics on electric machines of substation power system barred on quantitatively measured harmonics and proposed the methods for prevention of harmonics through checking on transformer, rectifier and cable's capacities against harmonics with reference to KEPCO's electricity service standard. In order to analysis harmoninics of silicon rectifier that is power source in DC substation, computer simulations for a substation with TR of high voltage distribution switchboard are performed. Simulation results show that the total harmonic distortion factor becomes smaller for TR primary and receiving points in order rather than silicon rectifier which is harmonic generation source so that the harmonics generated frets each rectifier are outflowed to power supply and high voltage distribution switchboard The result of higher distortion factors of voltage and current for rectifier with 100% load than those with 50 % and 30% indicates that the waveform of voltage and current for the real substation power system at the office-going and the closing hours with heavy loads might be more distorted. As proposed methods for harmonic reduction, the conventional 6 pulse-type for substation is required to be replaced by 12 pulse-type for reduction of 5th and 7th harmonics. The active filter rather than the passive filter is more effective due to severe variance of rectifier loads, but the high cost is price to be paid. In view of installation area and costs, the use of 12 pulse-type transformer is desirable and then the parallel transformer and the rectifier within the substation must be replaced at the same time. Other substations with parallel feeder can use 6 pulse-type transformer.

A study on the auto-charging circuit of the battery power units using trigger characteristics of semiconductor device (반도체 스위칭 소자의 트리거 특성을 이용한 배터리 자동 충전회로에 관한 연구)

  • 김영민;황종선;박성진;임종연;송승호
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.519-522
    • /
    • 2001
  • Recently, the battery charging technology and reducing technology of harmonics on AC input line are rising importantly according to increasing electrical facilities that it has been replaced battery with emergency power. In this study, I proposed that an auto-charging circuit of battery has low cost with simple-construction circuit, relative, harmonics reduction with diode tap-change method, high reliability of system for using characteristics of thyristor switching. In case of this circuit, convenience and reliability of maintenance of battery power units were more improved. 1 think that it is resulted in effect of prevention to shortening of battery life from over-charging and over-discharging and decrease of harmonics obstacle on AC input line.

  • PDF