• Title/Summary/Keyword: Harmonics reduction

Search Result 263, Processing Time 0.024 seconds

A novel energy-efficient bridgeless boost AC to DC converter (효율을 고려한 새로운 AC/DC 컨버터)

  • Yoon, Kyoung-Kuk;Kim, Seong-Hwan;Kim, Deok-Ki
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.40 no.3
    • /
    • pp.223-227
    • /
    • 2016
  • Power supplies make the load compatible with its power source. DC power supplies are extensively used with most electrical and electronic appliances such as computers, television, and audio sets. The presence of non-linear loads results in a low power factor and higher harmonics in the power system. Several techniques for power-factor correction and harmonic reduction have been reported in the literature. This paper proposes a bridgeless boost converter that improves the power factor and reduces the harmonic content in input line currents as compared to full-bridge rectifiers. This bridgeless boost converter eliminates the need of a line-voltage bridge rectifier in conventional boost converter and thereby reduces conduction losses. The effectiveness of the proposed scheme is verified by computer simulations by using the PSIM software.

Enhancement of Surface Hardness of Stainless Steel by Laser Peening (레이저피닝을 이용한 스테인리스강의 표면 경도 강화)

  • Lim, H.T.;Lee, M.H.;Kim, P.K.;Park, J.B.;Jeong, S.H.
    • Laser Solutions
    • /
    • v.12 no.3
    • /
    • pp.18-22
    • /
    • 2009
  • Experimental results for the laser shock peening of stainless steels, duplex stainless steel and STS304, for the enhancement of surface hardness are reported. A high power Nd:YAG laser (532 nm, 2nd harmonics) was used to irradiate the workpiece in water at the irradiances of 5, 10, $15\;GW/cm^2$. The surface of a workpiece was covered with Fe or Al foil for protection of the original surface and reduction of laser reflection. The laser pulse densities were varied from $25\;pulse/mm^2$ to $75\;pulse/mm^2$. In the case of the STS304, the surface hardness increased with increasing pulse density and the maximum increase of about 29% was achieved using Fe foil at $10\;GW/cm^2$ and $75\;pulse/mm^2$ conditions. The maximum increase in surface hardness of duplex stainless steel was about 8% at $10\;GW/cm^2$ and $75\;pulse/mm^2$ with also Fe foil. In the case of the Al foil, less increase of surface hardness was obtained, possibly due to the thermal expansion effect.

  • PDF

On a Pitch Alteration Method using Scaling the Harmonics Compensated with the Phase for Speech Synthesis (위상 보상된 고조파 스케일링에 의한 음성합성용 피치변경법)

  • Bae, Myung-Jin
    • The Journal of the Acoustical Society of Korea
    • /
    • v.13 no.6
    • /
    • pp.91-97
    • /
    • 1994
  • In speech processing, the waveform codings are concerned with simply preserving the waveform of signal through a redundancy reduction process. In the case of speech synthesis, the waveform codings with high quality are mainly used to the synthesis by analysis. Because the parameters of this coding are not classified as both excitation and vocal tract, it is difficult to apply the waveform coding to the synthesis by rule. Thus, in order to apply the waveform coding to synthesis by rule, it is necessary to alter the pitches. In this paper, we proposed a new pitch alteration method that can change the pitch period in waveform coding by dividing the speech signals into the vocal tract and excitation parameters. This method is a time-frequency domain method preserving the phase component of the waveform in time domain and the magnitude component in frequency domain. Thus, it is possible that the waveform coding is carried out the synthesis by rule in speech processing. In case of using the algorithm, we can obtain spectrum distortion with $2.94\%$. That is, the spectrum distortion is decreased more $5.06\%$ than that of the pitch alteration method in time domain.

  • PDF

Harmonic Reduction of Electric Propulsion Ship using New Rectification Scheme (새로운 정류방식을 이용한 전기추진선박의 고조파 저감)

  • Kim, Jong-Su;Choi, Jae-Hyuk;Yoon, Kyoung-Kuk;Seo, Dong-Hoan
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.16 no.10
    • /
    • pp.2230-2236
    • /
    • 2012
  • Currently, the AC-to-DC power conversion system using diode rectifiers is mainly used in large vessels. Also, to reduce the total harmonic distortion(THD) of current and voltage, this system requires an additional phase-shifting transformer which can be powered multi-pulses. In this case, due to the installation of the transformer, the spatial or economic loss occurs. This paper presents a novel active rectification scheme using silicon controlled rectifier(SCR) or insulated gate bipolar transistor(IGBT) devices on behalf of the diode rectifiers which are currently operating in large vessels such as LNG Carrier(LNGC). The proposed system can use the low voltage source and reduce current and voltage harmonics generated by nonlinear loads connected to the power distribution bus and save economic costs by removing the phase-shifting transformers which are used in conventional system. Computer simulations are performed under the electric propulsion system which is operating in current large vessel. The results are shown in support of the improvement of THD included in the current and voltage wave forms of propulsion motor.

The Analysis of the Parallel Coupled Line with an Open Stub and Its Branch-Line Hybrid Application (개방 스터브를 갖는 평행 결합 선로의 해석과 브랜치 라인 하이브리드에의 응용)

  • Lee, Won-Kyun;Hwang, Hee-Yong
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.19 no.1
    • /
    • pp.40-45
    • /
    • 2008
  • In this paper, the exact analysis of the parallel coupled line with open stub and an application to branch-line hybrid are presented. The Z-parameter of the parallel coupled line with an open stub is derived. The structure shows the characteristics as a lowpass filter unit cell(LUC) with wide stop band. Using the characteristics we designed a miniaturized branch-line hybrid with wide harmonic-suppressed band. The size of the new branch-line hybrid is a half of the conventional branch-line hybrid. The frequency response is the same with that of the conventional one near 1.7 GHz center frequency. Including the fifth harmonics, up to 12 GHz spurious responses are suppressed below to -20dB.

Mechanism Diagnosis and Avoidance Design on Transient Acoustic Vibration of Reheater Water Supply Piping in Supercritical Boiler (초임계 보일러 재열기 급수 공급배관의 과도 음향진동 진단 및 회피설계)

  • Kim, Yeon-Whan;Bae, Yong-Chae;Kim, Jae-Won;Lee, Doo-Young;Heo, Hae-Yong
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.23 no.5
    • /
    • pp.385-393
    • /
    • 2013
  • In this paper, the mechanism identification and the avoidance measures on the phenomena of transient acoustic vibration amplified at the water-supply piping system to regulate the steam temperature of the boiler reheater in 500MW class supercritical power plant are presented. The pressure pulsation waves induced by the impeller passing of two feed-water pumps with five blades are coincident with the local acoustic modes of boiler reheater water-supply piping system. There are the phenomena amplified at the peaks of 5X, 10X, 15X and 20X in spectrums of piping vibration, sound pressure, and the feed-water's pressure pulsation waves. The shut-off device is installed in the piping system for the interception of pressure pulsation waves transmitted from two feed-water pumps and the modified design change of the piping layout is applied for the acoustic resonance avoidance. The acoustic natural frequencies are separated from the harmonics of pressure pulsation waves induced by the pump impellers passing through the design change of the span length. The acoustic vibration is gone by resonance avoidance measures. As a result, more than 20 dBA reduction is achieved from 100 dBA to 80 dBA.

A Study on the High Performance Slip Power Recovery System in Induction Motor (유도전동기의 고성능 슬립전력 회수방식에 대한 연구)

  • Park, Han-Ung;Park, Seong-Jin;An, Jin-U;Park, Jin-Gil;Kim, Cheol-U;Hwang, Myeong-Mun
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.48 no.8
    • /
    • pp.431-439
    • /
    • 1999
  • Among the variable-speed AC motor drive systems, the static slip power recovery system has been widely adopted in large power drives because a high efficiency drive can be obtained by recovering the slip power to the AC line. Although many improvements have been made in this system, several problems also remain such as the need of transformer in inverter AC side, which results in limiting speed control range and increasing the losses, production of reactive power by the control of inverter firing angle, harmonics in line currents, and so on. This paper presents the novel high performance slip power recovery system using the boost converter and small size filter in the rotor circuit, which recovers slip power of a wound rotor induction machine to AC supply efficiently with the aid of the boost converter, in which most of the problems in conventional system can be solved. The speed can be controlled by the duty ratio of the converter switch, not by inverter firing angle. As a results, the proposed system can operate in high power factor and the harmonic currents caused by the inverter and rectifier can be considerably suppressed. The validity of the proposed system verified by demonstrating the good agreement in the simulation and experimental results.

  • PDF

Evaluation of Voltage Sag and Unbalance due to the System Connection of Electric Vehicles on Distribution System

  • Lee, Soon-Jeong;Kim, Jun-Hyeok;Kim, Doo-Ung;Go, Hyo-Sang;Kim, Chul-Hwan;Kim, Eung-Sang;Kim, Seul-Ki
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.2
    • /
    • pp.452-460
    • /
    • 2014
  • Due to increased concerns for rising oil prices and environmental problems, various solutions have been proposed for solving energy problems through tightening environmental regulations such as those regarding $CO_2$ reduction. Among them, Electrical Vehicles (EVs) are evaluated to be the most realistic and effective approach. Accordingly, research and development on EVs and charging infrastructures are mainly proceeding in developed countries. Since EVs operate using electric energy form a battery, they must be connected to the power system to charge the battery. If many EVs are connected during a short time, power quality problems can occur such as voltage sag, voltage unbalance and harmonics which are generated from power electronics devices. Therefore, when EVs are charged, it is necessary to analyze the effect of power quality on the distribution system, because EVs will gradually replace gasoline vehicles, and the number of EVs will be increased. In this paper, a battery for EVs and a PWM converter are modeled using an ElectroMagnetic Transient Program (EMTP). The voltage sag and unbalance are evaluated when EVs are connected to the distribution system of the Korea Electric Power Corporation (KEPCO). The simulation results are compared with IEEE standards.

Size Reduction of a Quasi Class-E High Power Amplifier Using Defected Ground Structure (결함 접지 구조를 이용한 유사 E급 전력 증폭기의 소형화)

  • Choi, Heung-Jae;Jeong, Yong-Chae;Lim, Jong-Sik;Jung, Young-Bae;Eom, Soon-Young;Kim, Chul-Dong
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.21 no.1
    • /
    • pp.61-68
    • /
    • 2010
  • In this work, a reduced size 20W quasi class-E Power Amplifier(PA) with defected ground structure load-network is presented for WCDMA base station application. Harmonic impedances required for the class E operation are satisfied by applying the dumbbell and the asymmetric spiral DGS. Open impedance for 2nd harmonic frequency which has the highest power and nearly short impedances for other higher order harmonics are provided by the proposed DGS load-network. The maximum Power Added Efficiency(PAE) of 70.2 % at the output power of 43.1 dBm with the saturated power gain of 12.7 dB is achieved by the proposed quasi class-E PA, which is comparable to the performance of the reference class-E PA. Total size of the proposed class-E PA is only $50{\times}50\;mm^2$ and much smaller than the conventional class-E PA that is loaded with a number of open stubs.

Investigating the Adjustment Methods of Monthly Variability in Tidal Current Harmonic Constants (조류 조화상수의 월변동성 완화 방법 고찰)

  • Byun, Do-Seong
    • Ocean and Polar Research
    • /
    • v.33 no.3
    • /
    • pp.309-319
    • /
    • 2011
  • This is a preliminary study of the feasibility of obtaining reliable tidal current harmonic constants, using one month of current observations, to verify the accuracy of a tidal model. An inference method is commonly used to separate out the tidal harmonic constituents when the available data spans less than a synodic period. In contrast to tidal constituents, studies of the separation of tidal-current harmonics are rare, basically due to a dearth of the long-term observation data needed for such experiments. We conducted concurrent and monthly harmonic analyses for tidal current velocities and heights, using 2 years (2006 and 2007) of current and sea-level records obtained from the Tidal Current Signal Station located in the narrow waterway in front of Incheon Lock, Korea. Firstly, the l-year harmonic analyses showed that, with the exception of $M_2$ and $S_2$ semidiurnal constituents, the major constituents were different for the tidal currents and heights. $K_1$, for instance, was found to be the 4th major tidal constituent but not an important tidal current constituent. Secondly, we examined monthly variation in the amplitudes and phase-lags of the $S_2$ and $K_1$ current-velocity and tide constituents over a 23-month period. The resultant patterns of variation in the amplitudes and phase-lags of the $S_2$ tidal currents and tides were similar, exhibiting a sine curve form with a 6-month period. Similarly, variation in the $K_1$ tidal constant and tidal current-velocity phase lags showed a sine curve pattern with a 6-month period. However, that of the $K_1$ tidal current-velocity amplitude showed a somewhat irregular sine curve pattern. Lastly, we investigated and tested the inference methods available for separating the $K_2$ and $S_2$ current-velocity constituents via monthly harmonic analysis. We compared the effects of reduction in monthly variability in tidal harmonic constants of the $S_2$ current-velocity constituent using three different inference methods and that of Schureman (1976). Specifically, to separate out the two constituents ($S_2$ and $K_2$), we used three different inference parameter (i.e. amplitude ratio and phase-lag diggerence) values derived from the 1-year harmonic analyses of current-velocities and tidal heights at (near) the short-term observation station and from tidal potential (TP), together with Schureman's (1976) inference (SI). Results from these four different methods reveal that TP and SI are satisfactorily applicable where results of long-term harmonic analysis are not available. We also discussed how to further reduce the monthly variability in $S_2$ tidal current-velocity constants.