• Title/Summary/Keyword: Harmonics reduction

Search Result 263, Processing Time 0.022 seconds

Improved ADALINE Harmonics Extraction Algorithm for Boosting Performance of Photovoltaic Shunt Active Power Filter under Dynamic Operations

  • Mohd Zainuri, Muhammad Ammirrul Atiqi;Radzi, Mohd Amran Mohd;Soh, Azura Che;Mariun, Norman;Rahim, Nasrudin Abd.
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.6
    • /
    • pp.1714-1728
    • /
    • 2016
  • This paper presents improved harmonics extraction based on Adaptive Linear Neuron (ADALINE) algorithm for single phase photovoltaic (PV) shunt active power filter (SAPF). The proposed algorithm, named later as Improved ADALINE, contributes to better performance by removing cosine factor and sum of element that are considered as unnecessary features inside the existing algorithm, known as Modified Widrow-Hoff (W-H) ADALINE. A new updating technique, named as Fundamental Active Current, is introduced to replace the role of the weight factor inside the previous updating technique. For evaluation and comparison purposes, both proposed and existing algorithms have been developed. The PV SAPF with both algorithms was simulated in MATLAB-Simulink respectively, with and without operation or connection of PV. For hardware implementation, laboratory prototype has been developed and the proposed algorithm was programmed in TMS320F28335 DSP board. Steady state operation and three critical dynamic operations, which involve change of nonlinear loads, off-on operation between PV and SAPF, and change of irradiances, were carried out for performance evaluation. From the results and analysis, the Improved ADALINE algorithm shows the best performances with low total harmonic distortion, fast response time and high source power reduction. It performs well in both steady state and dynamic operations as compared to the Modified W-H ADALINE algorithm.

Characterization of Fracture Roughness in Coarse.medium.fine Grained Granite (암반 불연속면의 거칠기 특성 - 조.중.세립질 화강암을 중심으로 -)

  • 김종태;정교철;김만일;송재용;박창근
    • The Journal of Engineering Geology
    • /
    • v.14 no.2
    • /
    • pp.147-168
    • /
    • 2004
  • Purpose of this study is to quantitatively characterize the fracture roughness which was measured with a confocal laser scanning microscope. The roughness discrete data measured by confocal laser microscope were analyzed by spectral analysis and fast Fourier transform (FFT).The roughness data by used noise reduction filter were applied for fractal analysis to describe roughness features quantitatively. Artificial fractures created by Brazilian test on granites were used to measure fracture roughness under the confocal laser scanning microscope. Measurements were performed along three scan lines on each fracture surface. 36 scan lines were determined on 12 specimens in total. Features of roughness showed that coarse and medium grained granites tend to more rough features than those of fine grained granites. Continuous analog data of roughness is possible to described as discrete data of measure roughness with a fixed interval under the confocal laser microscope. Results of FFT with the measured data showed the highest values on the second harmonics. Distribution of average amplitude of second harmonics was observed 0.9853 in coarse grained granite, 1.0792 in medium grained granite and 0.6794 in fine grained granite. This indicates that the larger roughness has the higher energy of harmonics as the result of fractal analysis in low frequency zone.

Analysis of Reduction Effect of Three Harmonic Currents by Zigzag Wiring of Single Phase Transformer (단상 변압기 지그재그 결선에 의한 3고조파 전류 저감 효과 분석)

  • Kim, Jong-Gyeum;Kim, Ji-Myeong
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.66 no.3
    • /
    • pp.99-104
    • /
    • 2017
  • The three-phase four-wire power distribution system can be used to supply power to single-phase and three-phase loads at the same time. There are linear loads and nonlinear loads as single-phase loads connected to each phase. The nonlinear load generates a harmonic current during the power energy conversion process. In particular, the single-phase nonlinear load has a higher proportion of generation of the third harmonic current than the harmonics of the other orders. In a three-phase four-wire system, the third harmonic current flows through the neutral wire to the power supply side, affecting the power supply side and the line. Furthermore, the magnitude of the current flowing in the neutral line can be higher than the current flowing in the individual phase. If the neutral current is higher than the phase current, the breaker may be blocked. Therefore, it is necessary to reduce the amount of current flowing in the neutral line by harmonics. There is a method of zigzag connecting a single phase transformer by a method of reducing 3 harmonic current. In this study, the method of reducing the magnitude of the three harmonic currents flowing through the zigzag wire by comparing the polarity and the negative polarity characteristics of the single phase transformer was compared through measurement and simulation.

Characteristics Analysis of Induction Motor by Operation of Non-linear Loads under the 3-Phase 4-Wire Grid System (3상 4선식에시 비선형 부하의 운전시 유도전동기의 특성 해석)

  • Kim, Jong-Gyeum;Park, Young-Jeen;Lee, Eun-Woong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.8
    • /
    • pp.54-62
    • /
    • 2006
  • Voltage unbalance will be generated by the load unbalance operation such as combination operation of single & three phase load and current unbalance will be more severe by the deteriorated voltage quality. Under the these unbalance conditions, all power electronic converters used in different types of electronic systems can increase harmonic disturbances by injecting harmonic currents directly into the feeder grid of three phase 4-wire. Harmonic current may cause torque to decrease. it may also overheat or become noisy and torque oscillation in the rotor can lead to mechanical resonance and vibration. This paper presents a scheme on the characteristics of induction motor under the combination of linear & non-linear loads at the three phase 4-wire power distribution system by the unbalance and harmonic components. It was able to confirm that the number of torque pulsation decreased and torque ripple values increased by the harmonics that reduction was difficult by five harmonics filters at additional driving time of single-phase non-linear load.

Harmonic Reduction of Electric Propulsion System by Current Injection (전류주입에 의한 전기추진시스템의 고조파 저감)

  • Kim, Jong-Su;Han, Won-Hui;Seo, Dong-Hoan
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.18 no.4
    • /
    • pp.360-364
    • /
    • 2012
  • AC to DC converter that consists of relatively simple diode rectifier devices has been widely used in the field of the electric propulsion system. Also, since this rectifier includes large harmonics in the input current, a variety of researches have been developed to reduce the harmonics. The proposed method of this paper is to reduce the harmonics included in the input current of rectifiers and propulsion motor by injecting the output current of diode rectifier into the input of them. In addition, the proposed method ensures electrical safety through the respective isolation of the injection current, the source, and the loads using the Wye-Delta insulating transformer applied in current injection device that is installed in the input circuit of rectifiers and propulsion motor. The proposed method is simulated by applying to the electric propulsion ship that is currently operating. We confirm the validity of the proposed method compared with conventional power conversion system.

A Study on Series Active Power Filter Compensating Unbalanced Source Voltage in 3phase-3wire system (불평형 전원전압을 보상하는 3상3선식 직렬형 능동전력필터에 관한 연구)

  • 오재훈;한윤석;김영석;원충연;최세완
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.6 no.5
    • /
    • pp.386-393
    • /
    • 2001
  • A series active power filter compensating current harmonics and unbalanced source voltages in a 3phase-3wire power system is presented. The system is composed of series active power filter and shunt passive filters that are tuned at 5th and 7th harmonics. The proposed series active power filter improves harmonic compensation characteristics of the shunt passive filters, reduces source side harmonic currents and compensates the unbalanced source voltages. In the proposed algorithm, compensation voltage for harmonic reduction is calculated by a performance function, and compensation voltage for the unbalanced source voltage is calculated based on the synchronous reference frame. Some results obtained from the experimental model using the proposed method are Presented to demonstrate and confirm its validity.

  • PDF

A Study on the Analysis and Application of Neutral Line Zero Sequence Currents Reduction Device in Commercial Facility Loads (상업용 설비 부하의 중성선 영상전류 저감장치 분석 및 적용에 관한 연구)

  • Kim, Kyung-Chul;Lee, Il-Moo;Paik, Seung-Hyun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.5
    • /
    • pp.54-60
    • /
    • 2004
  • With the proliferation of nonlinear loads such as commercial facilities in all of modern society high neutral harmonic currents have been observed. High neutral currents in three-phase four-wire distribution systems can cause lots of harmonic problems. The most common solution of neutral harmonic currents reduction is a zero phase sequence filter using zig-zag transformer. This paper analyzes a commercially available neutral line zero sequence currents reduction device and applies the equipment to commercial office loads for eliminating harmonics. Experimental results m compared numerically and graphically with simulation results through the use of MATLAB.

Switching Frequency Reduction Method for Modular Multi-level Converter Utilizing Redundancy Sub-module (예비 서브모듈을 활용한 모듈형 멀티레벨 컨버터의 스위칭 주파수 저감 기법)

  • Lee, Yoon-Seok;Yoo, Seung-Hwan;Choi, Jong-Yun;Park, Yong-Hee;Han, Byung-Moon;Yoon, Young-Doo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.12
    • /
    • pp.1640-1648
    • /
    • 2014
  • This paper proposes a switching frequency reduction method for MMC (Modular Multilevel Converter) utilizing redundancy operation of sub-module, which can offer reduction of voltage harmonics and switching loss. The feasibility of proposed method was verified through computer simulations with PSCAD/EMTDC software. Based on simulation analysis, a hardware scaled-model of 10kVA, DC-1000V MMC was designed and manufactured in the lab. Various experiments were conducted to verify the feasibility of proposed method in the actual hardware system. The hardware scaled-model can be effectively utilized for analyzing the performance of MMC according to the modulation scheme and redundancy operation.

A Stduy on the Analysis and Application of Neutral Line Zero Sequence Currents Reduction Device in Lighting Loads (조명부하의 중성선 영상전류 저감장치 분석 및 적용에 관한 연구)

  • Kim, Kyung-Chul;Lee, Il-Moo;Jung, Yung-Ho;Paik, Seung-Hyun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.3
    • /
    • pp.59-64
    • /
    • 2004
  • With the proliferation of nonlinear loads such as lighting facilities in all modern society high neutral harmonic currents have been observed. High neutral currents in three- phase four-wire distribution systems can cause lots of harmonic problems. The most common solution of neutral harmonic currents reduction is a zero phase sequence filter using zig-zag transformer. This paper analyzes a commercially available neutral line zero sequence currents reduction device and applies the equipment to lighting loads for eliminating harmonics. Experimental results are compared numerically and graphically with simulation results through the use of MATLAB.

A New Space Vector Random PWM Scheme for Induction Motor Drives

  • Kim Hoe-Geun;Na Seok-Hwan;Lim Young-Cheol;Jung Young-Gook
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.160-168
    • /
    • 2001
  • The RPWM (Random· Pulse Width Modulation) is a switching technique to spread the voltage and current harmonics over a wide frequency area. By using randomly changing switching frequency of the inverter, the power spectrum of the electromagnetic acoustic noise can be spread to the wide-band area. The wide­band noise is much more comfortable and less annoying than the narrow-band one. So, the RPWM has been attracting interest as an excellent method for the reduction of acoustic noise on the inverter drive system. In this paper a new RPPWM (Random Position Space Vector PWM) is proposed and implemented. Each of three phase pulses is located randomly in each switching interval. Along with the randomization of PWM pulses, the space vector modulation is also executed in the C167 micro-controller. The experimental results show that the voltage and current harmonics are spread to a wide band area and that the audible switching noise is reduced by the proposed RPPWM method.

  • PDF