• Title/Summary/Keyword: Harmonic voltage

Search Result 1,272, Processing Time 0.019 seconds

Power Noise Suppression Methods Using Bead with Spiral Resonator (비드와 나선형 공진기를 이용한 전원 노이즈 저감 방안 연구)

  • Chung, Tong-Ho;Kang, Hee-Do;Yook, Jong-Gwan
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.24 no.2
    • /
    • pp.152-160
    • /
    • 2013
  • In this paper, to the aim of wideband SSN(Simultaneous Switching Noise) suppression characteristic, investigation of spiral resonator are used in conjunction with bead which is commonly used for noise suppression method. Bead works effectively to suppress the power noise up to the first harmonic of fundamental frequency, 0.8 GHz, and spiral resonator suppress noise well in the frequency range of SRF(Self Resonance Frequency) which is inversely proportional to the length of spiral. Thus, when bead used in conjunction with a spiral the noise suppression characteristic is determined by the one of higher impedance element of the two in the frequency range and achieves more broadband filtering characteristic. The case for using 22 nH bead turns out 4.8, 2.0, 0, and, 0.6 dB, and the case for using 22 nH bead in conjunction with 3-turns spiral achieves more wideband characteristic of 9.5, 8.3, 6.1, and 9.9 dB power noise suppression performances at the first, second, third, and fourth harmonics, respectively. The peak-to-peak voltage levels decrease from 76 mV to 56 mV using 22 nH bead, and the level decrease rapidly to 34 mV when using in conjunction with bead and 3-turn spiral. Thus more wideband SSN suppression characteristic can be achieved using bead with spiral.

Analysis and Measurement of the Magnetic Fields Cause by Operation of Electromotive Installations (전동력설비의 운전에 의해 발생되는 자계의 측정과 해석)

  • 이복희;길경석
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.9 no.2
    • /
    • pp.58-67
    • /
    • 1995
  • The paper describes the variation of magnetic fields caused by the operation of induction motors. The measuring system consists of the self-integrating magnetic field sensor, amplifier, and active integrator. From the calibration experiments, the frequency bandwidth of the magnetic field measuring system ranges from 20[Hz] to 300[kHz] and sensitivity is 0.234(mV/$\mu\textrm{T}$]. The magnetic fields generated under steady state and starting operations of duction motor are recorded by the proposed measuring system, and the fast Fourier transformation(FFT) of the measured data is performed to analyze the harmonic components. A single pulsed magnetic field is strongly caused by direct starting the induction motor, and its peak value is greater than 5 times as compared with the steady state value. The long transient duration and high intensity originates from the large inductance and dynamic characteristic of the induction motor, During the steady state operation of induction motor, subharmonics of magnetic field components, which depend on the pole number of induction motor, are observed. The lower order power-line harmonics can be inferred from the voltage flicker and current ripple which are derived from the torque fluctuation of induction motor. In the case of the induction motor drived by inverter, the harmonics of magnetic field are much more than those caused by direct starting method and are found generally to increase with decreasing the driving frequency.

  • PDF