• 제목/요약/키워드: Harmonic currents

검색결과 343건 처리시간 0.023초

고차 고조파 전류의 보상을 위한 단상 능동전력필터 (Single-Phase Active Power Filter for Higher-order Harmonic Current Compensation)

  • 성기석;우명호;송중호;최익;임묘택
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제49권7호
    • /
    • pp.500-508
    • /
    • 2000
  • Basic design for single-phase active power filter, which aims at railway application provided with PWM-controlled converters, is comprehensively studied and its performance is presented in this paper. Active power filters are used to compensate railway signaling and public telecommunication interference due to the high-order harmonic currents generated in railway traction locomotives. A type of hybrid digital filter which is composed of low pass filter and high pass filter is proposed so that the desired harmonic reference current with accurate magnitude and phase shift can be extracted from catenary line current. A design criteria to determine input inductor L and output capacitor C is also described, considering voltage, current, PWM pattern, and switching frequency of the main converters. Finally, computer simulation and DSP-based experiments resulted from laboratory test are presented.

  • PDF

Harmonic Current Compensation based on Three-phase Three-level Shunt Active Filter using Fuzzy Logic Current Controller

  • Salim, Chennai;Benchouia, M.T.;Golea, A.
    • Journal of Electrical Engineering and Technology
    • /
    • 제6권5호
    • /
    • pp.595-604
    • /
    • 2011
  • A three-phase three-level shunt active filter controlled by fuzzy logic current controller which can compensate current harmonics generated by nonlinear loads is presented. Three-level inverters and fuzzy controllers have been successfully employed in several power electronic applications these past years. To improve the conventional pwm controller performance, a new control scheme based on fuzzy current controller is adopted for three-level (NPC) shunt active filter. The scheme is designed to improve compensation capability of APF by adjusting the current error using a fuzzy rule. The inverter current reference signals required to compensate harmonic currents use the synchronous reference detection method. This technique is easy to implement and achieves good results. To maintain the dc voltage across capacitor constant and reduce inverter losses, a proportional integral voltage controller is used. The simulation of global system control and power circuits is performed using Matlab-Simulink and SimPowerSystem toolbox. The results obtained in transient and steady states under various operating conditions show the effectiveness of the proposed shunt active filter based on fuzzy current controller compared to the conventional scheme.

Virtual Flux and Positive-Sequence Power Based Control of Grid-Interfaced Converters Against Unbalanced and Distorted Grid Conditions

  • Tao, Yukun;Tang, Wenhu
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권3호
    • /
    • pp.1265-1274
    • /
    • 2018
  • This paper proposes a virtual flux (VF) and positive-sequence power based control strategy to improve the performance of grid-interfaced three-phase voltage source converters against unbalanced and distorted grid conditions. By using a second-order generalized integrator (SOGI) based VF observer, the proposed strategy achieves an AC voltage sensorless and grid frequency adaptive control. Aiming to realize a balanced sinusoidal line current operation, the fundamental positive-sequence component based instantaneous power is utilized as the control variable. Moreover, the fundamental negative-sequence VF feedforward and the harmonic attenuation ability of a sequence component generator are employed to further enhance the unbalance regulation ability and the harmonic tolerance of line currents, respectively. Finally, the proposed scheme is completed by combining the foregoing two elements with a predictive direct power control (PDPC). In order to verify the feasibility and validity of the proposed SOGI-VFPDPC, the scenarios of unbalanced voltage dip, higher harmonic distortion and grid frequency deviation are investigated in simulation and experimental studies. The corresponding results demonstrate that the proposed strategy ensures a balanced sinusoidal line current operation with excellent steady-state and transient behaviors under general grid conditions.

전기로 부하의 고조파 측정, 평가 및 동조필터 적용에 관한 연구 (A Study on the Harmonics Measurement, Assessment and Resonant Filter Application of the Electric Arc Furnace Loads)

  • 김경철;진성은;이주홍
    • 조명전기설비학회논문지
    • /
    • 제20권6호
    • /
    • pp.35-42
    • /
    • 2006
  • 규모가 큰 제철소는 전기로를 포함한 비선형 부하를 가지고 있다. 이들 비선형 부하는 고조파 전류를 발생 시키고, 전력 계통의 전압을 왜곡시킨다. 본 논문에서는 전기로 부하의 고조파 현장 측정, 고조파 저감을 위해 수용가 모선에 동조 필터 적용과 국제 고조파 관리 기준인 IEC 61000-3-6과 IEEE Std. 519에 의한 고조파 평가를 심도 있게 분석한다. 고조파 해석 프로그램인 EDSA는 사례연구에 시뮬레이션 도구로 사용되었다.

Modelling and Performance Analysis of UPQC with Digital Kalman Control Algorithm under Unbalanced Distorted Source Voltage conditions

  • Kumar, Venkateshv;Ramachandran, Rajeswari
    • Journal of Power Electronics
    • /
    • 제18권6호
    • /
    • pp.1830-1843
    • /
    • 2018
  • In this paper, the generation of a reference current and voltage signal based on a Kalman filter is offered for a 3-phase 4wire UPQC (Unified Power Quality Conditioner). The performance of the UPQC is improved with source voltages that are distorted due to harmonic components. Despite harmonic and frequency variations, the Kalman filter is capable enough to determine the amplitude and the phase angle of load currents and source voltages. The calculation of the first state is sufficient to identify the fundamental components of the current, voltage and angle. Therefore, the Kalman state estimator is fast and simple. A Kalman based control strategy is proposed and implemented for a UPQC in a distribution system. The performance of the proposed control strategy is assessed for all possible source conditions with varying nonlinear and linear loads. The functioning of the proposed control algorithm with a UPQC is scrutinized and validated through simulations employing MATLAB/Simulink software. Using a FPGA SPATRAN 3A DSP board, the proposed algorithm is developed and implemented. A small-scale laboratory prototype is built to verify the simulation results. The stated control scheme for the UPQC reduces the following issues, voltage sags, voltage swells, harmonic distortions (voltage and current), unbalanced supply voltage and unbalanced power factor under dynamic and steady-state operating conditions.

다중 H-브릿지 인버터의 입력전류특성 (Line Current Characteristics of Multilevel H-Bridge Inverters)

  • 정승기
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2004년도 전력전자학술대회 논문집(1)
    • /
    • pp.335-340
    • /
    • 2004
  • Recently, multilevel H-bridge inverters have become more popular in medium to high power ac drive applications. One of significant advantages of them is low harmonic contents in their input line currents thanks to the transformer with multiple phase-shifted secondary windings. This paper attempts to provide basic guidelines for the design of the phase shifting transformer windings and theoretical analysis of input line current harmonics.

  • PDF

유동 전동기 구동을 위한 광역 전류원 콘버어터 2

  • 조규형;박송배
    • 전기의세계
    • /
    • 제30권1호
    • /
    • pp.41-46
    • /
    • 1981
  • In the current source inverters (CSI), which are widely used recently in many applications, in order to reduce the harmonic contents in the output line current, twelve-step waveform is synthesized usually by a phase-shifted addition of the output currents of two single CSI's. In this paper a new method of synthesis of the 12-step current waveform is suggested which employes a main and a new auxiliary inverters having lower capacity, and thus is economically advantageous over the conventional scheme. DC-side commutation and energy rebond circuit as described in Part I are also employed in this proposed twelve-step CIS for effective commutation and high reliability. Experimental results are also given in oscillgrams.

  • PDF

영전류 스위칭과 높은 공진 주파수로 동작하는 교류-대-직류 역률개선 정류회로 (Soft-switched, High Frequency Resonant AC-to-DC Rectifier with High Power Factor)

  • 최현칠;정영석;윤명중
    • 대한전기학회논문지
    • /
    • 제43권6호
    • /
    • pp.916-926
    • /
    • 1994
  • A high frequency and soft-switched AC-to-DC rectifier employing a series-type resonant circuit is proposed to overcome the disadvantages of the conventional peak-rectifying circuit. Using the proposed rectifier, the high power factor and low harmonic currents are obtained in the AC line. Furthermore, several advantages such as the high power density and wide output voltage range can be available. Through the simulation and experimental results, the usefulness of the proposed rectifier is verified.

Comparative Analysis of LCL and LLCL Filters for Three-level PWM Converters

  • Alemi, Payam;Le, Quoc Anh;Lee, Dong-Choon
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2014년도 전력전자학술대회 논문집
    • /
    • pp.283-284
    • /
    • 2014
  • In this paper, a comparative analysis of LCL and LLCL filters connected to three-level T-type PWM converters is presented, in which the filter inductor sizes are investigated in view of total harmonic distortion (THD) in grid phase currents. The analysis results are verified by simulation and experiments.

  • PDF

제주도 하수처리장 해양방류구 인근해역의 늦은 봄철 조류 특성과 조석잔차류에 의한 오염물질의 분포 특성 (Characteristics of Tide-induced Flow and its Effect on Pollutant Patterns Near the Ocean Outfall of Wastewater Treatment Plants in Jeju Island in Late Spring)

  • 김준택;홍지석;문재홍;김상현;김태훈;김수강
    • 한국해양학회지:바다
    • /
    • 제26권2호
    • /
    • pp.63-81
    • /
    • 2021
  • 이 연구에서는 2018년 늦은 봄철을 대상으로, 제주도내 위치한 제주와 보목 하수처리장의 해양방류구 주변 해역의 하수처리 방류수의 이동 특성을 파악하기 위하여 다층 유향·유속계 (Acoustic Doppler Current Meter; ADCP)와 지역규모 해양 수치모델의 가상 추적자 실험을 활용한 분석을 수행하였다. ADCP관측 결과에 의하면 두 하수처리장 모두 방류구 인근 해역의 해수 유동은 비조석 성분 보다 조석 성분이 컸고, 조류는 등수심선과 평행한 방향의 왕복성 운동이 지배적이었다. 조화 분석결과는 제주와 보목 하수처리장 해역 모두 반일주기 유속 성분이 우세한 혼합형 조석특성이 지배적이지만, 보목 하수처리장 주변의 유속 세기가 제주 하수처리장 유속의 50% 정도로 느리고, 조류의 회전성이 제주는 시계 방향, 보목의 경우 반시계 방향으로 지역적으로 차이를 보인다. 특히, 보목 하수처리장 방류구 주변해역은 상대적으로 느린 유속과 더불어 잔차류가 등수심선을 가로질러 연안으로 향하기 때문에 해안을 따라 오염물질이 집적되는데 유리한 환경이다. 고해상도 수치실험은 유속·유향 현장 관측 결과와 유사한 해수 유동 특성을 잘 모의하였으며, 오염물질의 이동확산을 파악하기 위한 추적자 실험을 통하여 잔차성분이 연안을 향하는 보목 하수처리장 연안에서 오염물질 잔류량이 상대적으로 높아질 수 있음을 제시하였다. 이러한 결과는 늦은 봄철에 보목 하수처리장 인근 해역이 상대적으로 약한 조류와 연안을 향하는 잔차성분의 영향으로 하수처리 방류수에 의한 연안 오염 가능성이 높은 환경임을 제시하는 결과이다. 퇴적유기물 조사에서도 보목하수처리장 인근 연안은 중간오염 단계를 보임으로써 조석 잔자류에 의한 연안 오염물질 축적과 그에 따른 연안환경오염의 가능성을 뒷받침하고 있다.