• Title/Summary/Keyword: Harmonic current source

Search Result 284, Processing Time 0.028 seconds

The analysis of induction motor drived by PWM voltage source inverter (PWM 인버터 전압원 구동에 의한 유도전동기해석)

  • Kim, Do-Wan;Gwak, In-Gu;Lee, Hyang-Beom;Park, Il-Han;Hahn, Song-Yop
    • Proceedings of the KIEE Conference
    • /
    • 1995.07a
    • /
    • pp.71-73
    • /
    • 1995
  • For the accurate analysis of induction motors driven by PWM-type inverter, a time-stepping finite element method is presented in this paper. Since the PWM-type source voltage is not sinusoidal, the time harmonic method can not be used. Therefore, we used a time-stepping method, where the space harmonics due to the slot structure can be analyzed and each time-step size is determined from each increase of rotor position. As a numerical example, an induction motor of 20 Hp, 3 phase and 6 pole is analyzed. First, numerical results of the time-stepping finite element analysis are compared to those of conventional equivated circuit analysts. Next, the stator current characteristic obtained from PWM voltage source is compared to that from sinusoidal voltage source.

  • PDF

PWM Method with Low d-axis Current Ripple for reducing Input Current THD at Light Loads in Three Phase PWM Rectifier (3상 PWM 정류기의 경부하시 입력전류 THD 저감을 위한 d축 전류리플 저감 PWM 방법)

  • Jin, Yong-Sin;Shin, Hee-Keun;Kim, Hag-Wone;Cho, Kwan-Yuhl
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.17 no.6
    • /
    • pp.478-485
    • /
    • 2012
  • In this paper, a new PWM method is proposed to reduce the input current harmonics of 3 phase PWM rectifier. In the conventional carrier comparison PWM method, a triangular wave is generally used as the carrier wave. However, the large d-axis current ripple by the triangle carrier wave may be a source of large input current THD(Total Harmonic Distortion). In this paper, a new carrier comparison PWM method with saw tooth wave is proposed. Depending on the sector where the voltage command vector places, one of the rising or falling saw tooth wave is selected. To reduce the switching losses of the saw tooth carrier PWM, the discontinuous PWM is also presented. The proposed PWM method can reduce the d-axis current ripple as well as the switching losses. The performance of the conventional and proposed PWM methods is verified by the simulation and experimental results.

Three-Phase 4-Wire Isolated Wind Energy Conversion System Employing VSC with a T-Connected Transformer for Neutral Current Compensation

  • Kasal, Gaurav Kumar;Singh, Bhim
    • Journal of Electrical Engineering and Technology
    • /
    • v.4 no.2
    • /
    • pp.211-218
    • /
    • 2009
  • This paper presents a voltage and frequency controller (VFC) for a 4-wire stand-alone wind energy conversion system (WECS) employing an asynchronous generator. The proposed VF con-troller consists of a three leg IGBT (Insulated Gate Bipolar Junction Transistor) based voltage source converter and a battery at its DC bus. The neutral terminal for the consumer loads is created using a T-connected transformer, which consists of only two single phase transformers. The control algorithm of the VF controller is developed for the bidirectional flow capability of the active power and reactive power control by which it controls the WECS voltage and frequency under different dynamic conditions, such as varying consumer loads and varying wind speeds. The WECS is modeled and simulated in MATLAB using Simulink and PSB toolboxes. Extensive results are presented to demonstrate the capability of the VF controller as a harmonic eliminator, a load balancer, a neutral current compensator as well as a voltage and frequency controller.

Comparative Study of Flux Regulation Methods for Hybrid Permanent Magnet Axial Field Flux-switching Memory Machines

  • Yang, Gongde;Fu, Xinghe;Lin, Mingyao;Li, Nian;Li, Hao
    • Journal of Power Electronics
    • /
    • v.19 no.1
    • /
    • pp.158-167
    • /
    • 2019
  • This research comparatively studies three kinds of flux regulation methods, namely, stored capacitor discharge pulse (SCDP), constant current source pulse (CCSP), and quantitative flux regulation pulse (QFRP), which are used for hybrid permanent magnet (PM) axial field flux-switching memory machines (HPM-AFFSMMs). Through an analysis of the operation principle and the series hybrid PM flux regulation mechanism of the objective machine, the circuit topologies and flux regulation process of these flux regulation methods are addressed in detail. On the basis of a simulation, the flux regulation characteristics of the researched machine during the magnetization and demagnetization processes are comparatively evaluated. Then, machine performance, including back EMF, direct and quadrature axis inductances, and magnetization and demagnetization characteristics, is quantitatively investigated. Results show that the QFRP enables the HPM-AFFSMM to achieve a less harmonic component of back EMF by approximately 7.28% and 7.97% at the magnetization and demagnetization states, respectively, and a more complete magnetization process than the SCDP and CCSP.

Analysis of Magnetic Fields Induced by Line Currents using Coupling of FEM and Analytical Solution (선전류에 의해 발생되는 자장의 해석을 위한 유한요소법과 해석해의 결합 기법)

  • Kim, Young-Sun;Cho, Dae-Hoon;Lee, Ki-Sik
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.55 no.3
    • /
    • pp.141-145
    • /
    • 2006
  • The line current problem(2-dimensional space : point source) is not easy to analyze the magnetic field using the standard finite element method(FEM), such as overhead trolley line or transmission line. To supplement such a defect this paper is proposed the coupling scheme of analytical solution and FEM. In analysis of the magnetic field using the standard FEM. If the current region is a relatively small compared to the whole region. Therefore the current region must be finely divided using a large number of elements. And the large number of elements increase the number of unknown variables and the use of computer memories. In this paper, an analytical solution is suggested to supplement this weak points. When source is line current and the part of interest is far from line current, the analytical solution can be coupling with FEM at the boundary. Analytical solution can be described by the multiplication of two functions. One is power function of radius, the other is a trigonometric function of angle in the cylindrical coordinate system. There are integral constants of two types which can be established by fourier series expansion. Also fourier series is represented as the factor to apply the continuity of the magnetic vector potential and magnetic field intensity with tangential component at the boundary. To verify the proposed algorithm, we chose simplified model existing magnetic material in FE region. The results are compared with standard FE solution. And it is good agreed by increasing harmonic order.

Feasibility study on the design of DC HTS cable core

  • Sim, Ki-Deok;Kim, Seok-Ho;Jang, Hyun-Man;Lee, Su-Kil;Won, Young-Jin;Ko, Tae-Kuk
    • Progress in Superconductivity and Cryogenics
    • /
    • v.12 no.4
    • /
    • pp.24-30
    • /
    • 2010
  • The renewable energy source is considered as a good measure to cope with the global warming problem and the fossil energy exhaustion. The construction of electric power plant such as an offshore wind farm is rapidly increasing and this trend is expected to be continued during this century. The bulky and long distance power transmission media is essential to support and promote the sustainable expansion of renewable energy source. DC power cable is generally considered as the best solution and the demand for DC electric power has been rapidly increasing. Especially, the high temperature superconducting (HTS) DC cable system begins to make a mark because of its advantages of huge power transmission capacity, low transmission loss and other environmental friendly aspects. Technical contents of DC HTS cable system are very similar to those of AC HTS cable system. However the DC HTS cable can be operated near its critical current if the heat generation is insignificant, while the operating current of AC HTS cable is generally selected at about 50~70% of the critical current because of AC loss. We chose the specifications of the cable core of 'Tres Amigas' project as an example for our study and investigated the heat generation when the DC HTS cable operated near the critical current by some electric and thermal analyses. In this paper, we listed some technical issues on the design of the DC HTS cable core and described the process of the cable core design. And the results of examination on the current capacity, heat generation, harmonic loss and current distribution properties of the DC HTS cable are introduced.

Parallel operation of rectifier with unit-power factor (단위역률 정류기의 병렬운전)

  • Lee, Seung-Heui;Kim, Tae-Won;Park, Jae-Wook
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1212-1213
    • /
    • 2011
  • PWM(pulse width modulation) rectifier has unit power factor and low harmonic distortion with high power conversion efficiency in entire loading range. These merits of PWM rectifier help the spread of DC distribution system. In addition, if multiple PWM rectifiers can be operated in parallel connection, maintenance process can be simple and reliability of power source can be advanced because of the hot swapping is available. The other way, the load unbalance among rectifiers can force a converter to stop by over current. The surge current by closed circuit composition between rectifiers can force switching devices damage. In this paper, some problems that can occur in case of parallel operation of PWM rectifiers and problem eliminating methods are considered.

  • PDF

Analysis and design DC-DC converter for solar cell array output control (태양전지 출력제어를 위한 DC-DC 컨버터의 해석 및 설계)

  • 고재석
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.665-669
    • /
    • 2000
  • Recently the problem of energy branch become worse increasingly. Therefore many researches about new energy source are processing in several places around are processing in several places around the world. Especially solar energy has many advantages like as purity and infinity. Photovoltaic(PV) system can be classified into two types : One is stand alone type and the other is utility interactive one. Utility interactive type PV system need some technology that Maximum peak power tracking(MPPT) and Anti-islanding and Active Power filter(APF). For APF operation dc-link voltage should be high to supply sufficient output current which needed for harmonic current compensation so usually DC-DC converter is used for boost. In this paper DC-DC converter for PV system and controller for dc-link voltage control are analyzed and designed.

  • PDF

Battery Energy Storage System Based Controller for a Wind Turbine Driven Isolated Asynchronous Generator

  • Singh, Bhim;Kasal, Gaurav Kumar
    • Journal of Power Electronics
    • /
    • v.8 no.1
    • /
    • pp.81-90
    • /
    • 2008
  • This paper presents an investigation of a voltage and frequency controller for an isolated asynchronous generator (IAG) driven. by a wind turbine and supplying 3-phase 4-wire loads to the isolated areas where a grid is not accessible. The control strategy is based on the indirect current control of the VSC (voltage source converter) using the frequency PI controller. The proposed controller consists of three single-phase IGBT (Insulated Gate Bipolar Junction Transistor) based VSC, which are connected to each phase of the IAG through three single phase transformers and a battery at their DC link. The controller has the capability of controlling reactive and active powers to regulate the magnitude and frequency of the generated voltage, harmonic elimination, load balancing and neutral current compensation. The proposed isolated system is modeled and simulated in MATLAB using Simulink and PSB (Power System Block-set) toolboxes to verify the performance of the controller.

Two-stage & Single-stage Power Factor Correction circuits for Single-phase Power source (단상전원에 적합한 단일단 및 2단 역률개선회로)

  • Kim Chert-Jin;Yoo Byeong-Kyu;Kim Choong-Sik;Kim Young-Tae
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.1214-1216
    • /
    • 2004
  • Conventional Switched Mode Power Supplies(SMPS) with diode-capacitor rectifier have distorted input current waveform with high harmonic contents. Typically, these SMPS have a power factor lower than 0,65. To improve with this problem the power factor correction(PFC) circuit of power supplies has to be introduced. PFC circuit have tendency to be applied in new power supply designs. The input active power factor correction circuits can be implemented using either the two-stage or the single-stage approach. In this paper, the comparative analysis of power factor correction circuit using feedforward control with average current mode single-stage flyback method converter and two-stage converter which is combination of boost and flyback converter. The two prototypes of 50W were designed and tested a laboratory experimental. Also, the comparative analysis is confirmed by simulation and experimental results.

  • PDF