• Title/Summary/Keyword: Harmonic components

Search Result 560, Processing Time 0.032 seconds

Harmonic and Percussive Separation Based on NMF and Tonality Mask

  • Choi, Keunwoo;Chon, Sang Bae;Kang, Kyeongok
    • ETRI Journal
    • /
    • v.34 no.6
    • /
    • pp.958-961
    • /
    • 2012
  • In this letter, we present a new algorithm for the harmonic and percussive separation of jazz music. Using a short-time Fourier transform and nonnegative matrix factorization, the signal is decomposed into rank components. Each component is then split into harmonic and percussive parts using masks calculated based on their tonalities. Finally, the harmonic and percussive parts are separated after applying the masks and a summation. We evaluate the algorithm based on real audio examples using both objective and subjective assessments. The proposed algorithm performs well for the separation of harmonic and percussive parts of jazz excerpts.

Hybrid-Type Active Power Filters for Compensating Harmonic Current and Unbalanced Source Voltages (고조파 전류와 불평형 전원전압 보상을 위한 복합형 능동전력 필터)

  • Lee, Ji-Myeong;Lee, Dong-Chun
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.51 no.5
    • /
    • pp.249-257
    • /
    • 2002
  • In this paper, a novel control scheme compensating source voltage unbalance and harmonic currents for the combined system of series active and shunt passive power filter is proposed, where no low/high-pass filters are used in deriving the reference voltage for compensation. The phase angle and the reference voltages compensating for harmonic current and unbalanced voltage are derived from the positive sequence component of the unbalanced voltage set, which is simply obtained by using digital all-pass filters. In order to remove the phase delay in generating the reference voltage for compensation, the reference of 5th and 7th harmonic components is predicted one-sampling ahead. The validity of the proposed scheme has been verified for 3[kVA] proto-type active power filter system.

Novel Current Compensation Technique for Harmonic Current Elimination (고조파 전류 제거를 위한 새로운 전류 보상 기법)

  • Jeong Gang-Youl
    • Proceedings of the KIPE Conference
    • /
    • 2004.07b
    • /
    • pp.587-591
    • /
    • 2004
  • This paper proposes a novel current compensation technique that can eliminate the harmonic currents included in line currents without computation of harmonic current components. A current controller with fast dynamics for an active filter is described. Harmonic currents are directly controlled without the need for sensing and computing the harmonic current of the load current, thus simplifying the control system. Current compensation is done in the time domain, allowing a fast time response. The DC voltage control loop keeps the voltage across the DC capacitor constant. High power factor control by an active filter is described. All control functions are implemented in software using a single-chip microcontroller, thus simplifying the control circuit. Any current-controlled synchronous rectifier can be used as a shunt active filter through only the simple modification of the software and the addition of current sensors. It is shown through experimental results that the proposed controller gives good performance for the shunt active filter.

  • PDF

Analysis of Fatigue Damage of the parts around the vehicle engine with Respect to Road surface conditions (도로 노면 조건을 고려한 차량 엔진 주변 부품의 피로손상도 분석)

  • Shin, Sung-Young;Kim, Chan-Jung;Lee, Bong-Hyeon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.581-586
    • /
    • 2014
  • In general vibration test considers both harmonic vibration and random vibration, When developing the vehicle component. But the effect of harmonic vibration is larger in the parts around the vehicle engine, sole testing the harmonic vibration is considered. In this study, the fatigue damage of the linear system fixed around the engine is analyzed when the effect of random vibration is higher, harsher than the normal road surface condition. In condition the vehicle speed and the engine RPM are similar, the higher the harshness of the road surface condition is, the larger the fatigue damage level is. Therefore both random vibration and harmonic vibration must be considered in vibration test of components around the engine. Proposing the sine on random(SOR) vibration test that can exam considering both of vibrations, harmonic and random.

  • PDF

Research on a Multi-Objective Control Strategy for Current-source PWM Rectifiers under Unbalanced and Harmonic Grid Voltage Conditions

  • Geng, Yi-Wen;Liu, Hai-Wei;Deng, Ren-Xiong;Tian, Fang-Fang;Bai, Hao-Feng;Wang, Kai
    • Journal of Power Electronics
    • /
    • v.18 no.1
    • /
    • pp.171-184
    • /
    • 2018
  • Unbalanced and distorted grid voltages cause the grid side current of a current source PWM rectifier to be heavily distorted. They can also cause the DC-link current to fluctuate with a huge amplitude. In order to enhance the performance of a current-source PWM rectifier under unbalanced and harmonic grid voltage conditions, a mathematical model of a current-source PWM rectifier is established and a flexible multi-objective control strategy is proposed to control the DC-link current and grid-current. The fundamental positive/negative sequence, $5^{th}$ and $7^{th}$ order harmonic components of the grid voltage are first separated with the proposed control strategy. The grid current reference are optimized based on three objectives: 1) sinusoidal and symmetrical grid current, 2) sinusoidal grid current and elimination of the DC-current $2^{nd}$ order fluctuations, and 3) elimination of the DC-current $2^{nd}$ and $6^{th}$ order fluctuations. To avoid separation of the grid current components, a multi-frequency proportional-resonant controller is applied to control the fundamental positive/negative sequence, $5^{th}$ and $7^{th}$ order harmonic current. Finally, experimental results verify the effectiveness of proposed control strategy.

Development of Medical Ultrasound Imaging Techniques for Tissue Characterization (Attenuation Effect on Measurement and Tomography of Nonlinear Parameter) (조직 정량화를 위한 의용 초음파 영상 기술 개발(비선형 파라미터의 측정 및 단층영상에 미치는 감쇠의 영향))

  • 이현주;이강호;최종호;최종수
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.27 no.12
    • /
    • pp.1916-1924
    • /
    • 1990
  • In this paper attenuation effect on the measurement and the tomography of nonlinear parameter is discussed. We perform computer simulation with the method using harmonic components and the method using secondary wave components, and then estimate attenuation effect through the results and compare two measurement techniques. According to simulation result the attenuation effect is more intensive as large n and \ulcorner, and the degree of the attenuation effect is represented as error functions. In the aspect of measuremnet techniques, the method using secondary wave components is more insensitive to attenuation effect than the method using harmonic compnents. We obtain the same result in the nonlinear tomography, and show that the attenuation compensive filter is required because the whole tomogram is affected by frequency dependent attenuation(or nonlinear attenuation)

  • PDF

NEW ADAPTIVE METHOD FOR VOLTAGE SAG AND SWELL DETECTION

  • Mohamed, Mansour A.
    • Journal of the Korea Convergence Society
    • /
    • v.4 no.1
    • /
    • pp.33-41
    • /
    • 2013
  • This paper presents an adaptive recursive least squares algorithm (ARLS) for detecting voltage sag and voltage swell events in power systems. Different methods have been developed to detect voltage sag and voltage swell. Some of them use window techniques, which are too slow when voltage sag or swell mitigation is required. Others depend on the extraction of a single non-stationary sinusoidal signal out of a given multi-components input signal, and therefore they don't consider the harmonic components in calculating the voltage root mean square value (rms). The method, proposed in this paper, is capable of estimating the voltage rms taking into account all harmonic components. The method is tested by applying it to different, simulated signals using ATP program, and compared with voltage sag detection algorithms.

Compensation of Neutral Point Deviation under Generalized 3-Phase Imbalance in 3-level NPC

  • Jung, Kyungsub;Suh, Yongsug
    • Journal of Power Electronics
    • /
    • v.18 no.6
    • /
    • pp.1866-1878
    • /
    • 2018
  • This paper presents a neutral point deviation and ripple compensation control method for application to 3-level NPC converters. The neutral point deviation and its harmonic components are analyzed with a focus on the average current flowing through the neutral point of the dc-link. This paper also proposes a control scheme to compensate for the neutral point deviation and dominant harmonic components under generalized unbalanced grid operating conditions. The positive and negative sequence components of the pole voltages and ac input currents are employed to accurately explain the behavior of 3-level NPC converters. Simulation and experimental results are presented to verify the validity of the proposed method.

Analysis on Waveform of Leakage Current of Contaminated EPDM Insulators by Salt Fog (Salt fog에 의한 오손된 EPDM애자의 누설전류 파형 분석)

  • Park, Jae-Jun;Song, Young-Chul;Kim, Jeong-Boo;Lee, You-Min;Lee, Hyun-Dong;Jung, Young-Ho
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.36-41
    • /
    • 2003
  • This paper presents the results of power spectra using the fundamental and low frequency harmonic components of leakage current waveform to study aging on contaminated EPDM insulator(was serviced during 1997-2001, region Pohang, korea) under salt fog conditions. Experiments have been conducted in the chamber salt fog and at the 16KVrms. The salt contents adjusted as 0g,25g,50g and 75g per liter of deionized water. The onset of dry-band arcing on polymer insulators could be determined by signal processing the low frequency harmonics components. A correlation has been found between the fundamental and low harmonic components of power spectra on leakage current. Where aging could be associated with an increase in the level of both the fundamental and low frequency harmonics components of leakage current. Surface aging for contaminated EPDM insulators occurred when the fundamental component of leakage current was greater then some level On the other hand, when the polymer insulator approached failure, the fundamental component of leakage current reached relatively high values and low frequency harmonics components of the leakage current trended to decrease. The results suggest that both the fundamental and low frequency harmonics of leakage current can be used as a tool to determine both the beginning of aging and before flashover, end of life EPBM insulator in salt fog.

  • PDF

Analysis on the Occurrence Probability Distribution of Tidal Levels using Harmonic Constants (조화상수를 이용한 조위 발생확률분포 분석)

  • Jeong Shin Taek;Cho Hong Yeon;Kim Jeong Dae;Cho Byum Jun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2005.05b
    • /
    • pp.1053-1057
    • /
    • 2005
  • The occurrence probability (OP) distributions of tide levels using harmonic constants of six tidal gauging stations in Korean coastal zone were estimated and analysed in detail. OP analysis using harmonic constants data of Incheon(Youldo), Mokpo, Yeosu, Pusan, Pohang and Sokcho was carried out and compared with the OP using hourly tidal elevation data which were served through the Internet Homepage by the National Ocean Research Institute. The tidal elevation data were divided by the AHHW (ALLW) value referenced to MSL in order to compare the OP patterns in a relative scale. The OP of the tidal elevation calculated using 38 harmonic tidal constituents relatively well agreed with those of hourly observed tidal elevation data. However, the OP results using four harmonic tidal constituents overestimate the occurrence probability at the peak points and underestimate at the tail-regions of the OP. Especially, the OP patterns of the Sokcho and Pohang tidal gauging stations on the East Sea show totally different patterns and the estimation method using four harmonic constants should be modified and application should be strictly limited on the East Sea areas. The OP patterns are considerably well generated in case of the OP generation using the additional two or three dominant tidal constituents,

  • PDF