• 제목/요약/키워드: Harmonic Simulation

검색결과 976건 처리시간 0.038초

가변속 3상 유도 전동기의 토오크 변동 최소화를 위한 OPtimal PWM 방식 (Optimal PWM Strategy for Minimization of Torque Ripplis of a Variable Speed 3phase Induction Motor)

  • 이윤종;정동화
    • 대한전기학회논문지
    • /
    • 제35권6호
    • /
    • pp.217-225
    • /
    • 1986
  • This paper describes the Optimal PWM strategy to reduce a pulsating harmonic torque for a variable-speed drive of 3 phase induction motor. This paper suggests the new Optimal control theory which consists of 1) defining a performance index related to the unwanted effects of the voltage harmonics, (i.e., the components of pulsating harmonic torques) 2) achieving its minimization by a suitable choice of the switching patterns. (i.e., of the commutation angles) This PWM strategy is compared with the conventional SPWM strategy by numerical method. It is believed that this proposed strategy can reduce more harmonic components and pulsating harmonic torques than SPWM strategy. Also, We could verify the validety of the numerical method by a result of simulation analysis of a variable speed 3phase induction motor.

  • PDF

부스트컨버터의 고조파저감을 위한 스위칭 기법에 관한 연구 (A study On the Switching Technique of Boost Converter for Harmonic Reduction)

  • 손진근;추순남;김용혁;이상철;이복용
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 학술대회 논문집 전문대학교육위원
    • /
    • pp.74-78
    • /
    • 2000
  • In this paper a switching control circuit for shaping the line current and reducing the total harmonics distortion in the boost converter is presented. To solve the problems of performance degradation due to pulse waveform in the input current, the boost converter in which the harmonic distortion in the input current is reduced using a 3th harmonic-injected PWM is proposed. Finally, Simulation and experimental results of boost converter with 5[kHz] switching frequency are presented and correction of power factor and reduction of total harmonic distortion was established.

  • PDF

Measurements of Sub- and Super Harmonic Waves at the Interfaces of Fatigue-Cracked CT Specimen

  • Jeong, Hyun-Jo;Barnard, Dan
    • 비파괴검사학회지
    • /
    • 제31권1호
    • /
    • pp.1-10
    • /
    • 2011
  • Nonlinear harmonic waves generated at cracked interfaces are investigated both experimentally and theoretically. A compact tension specimen is fabricated and the amplitude of transmitted wave is analyzed as a function of position along the fatigued crack surface. In order to measure as many nonlinear harmonic components as possible a broadband Lithium Niobate ($LiNbO_3$) transducers are employed together with a calibration technique for making absolute amplitude measurements with fluid-coupled receiving transducers. Cracked interfaces are shown to generate high acoustic nonlinearities which are manifested as harmonies in the power spectrum of the received signal. The first subharmonic (f/2) and the second harmonic (2f) waves are found to be dominant nonlinear components for an incident toneburst signal of frequency f. To explain the observed nonlinear behavior a partially closed crack is modeled by planar half interfaces that can account for crack parameters such as crack opening displacement and crack surface conditions. The simulation results show reasonable agreements with the experimental results.

확률론적 방법을 이용한 교류 고속철도 시스템의 고조파 해석 (Harmonics Analysis of AC High Speed Railroad(HSR) System using Probabilistic Approach)

  • 송학선;이준경;김진오;김형철
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2005년도 춘계학술대회 논문집
    • /
    • pp.782-787
    • /
    • 2005
  • Magnitude of generated harmonic currents along with the operation of AC traction has nonlinear characteristics, and generated harmonic currents for high speed traction are more and more in high speed railroad(HSR) systems, especially. This paper presents probabilistic approximation method for the harmonic currents analysis about the operating speed of AC traction. To use probabilistic method for HSR system, probability density function(PDF) for collected operating speed based measure data is calculated. Mean and variance of harmonic currents of single traction are obtained based on the operating speed PDF and electrical traction model. The results of Monte Carlo Simulation(MCS) are in well accordance with the experimental and analytic methods. The harmonics of different number of trainloads are systematically investigated. It is assessed by the total demand distortion(TDD) for the HSR system.

  • PDF

9개의 하모닉을 억제하는 월킨슨 전력 분배기 (Modified Wilkinson Power Divider for Harmonic 제거)

  • 강인호;김정훈
    • 한국전자파학회:학술대회논문집
    • /
    • 한국전자파학회 2003년도 종합학술발표회 논문집 Vol.13 No.1
    • /
    • pp.273-277
    • /
    • 2003
  • This paper presents a structure of the Wilkinson power divider that can suppress the 9ea harmonic output. The power divider consists of ${\lambda}/4n$ open stubs, which are located at the $3{\lambda}/4$ branches and parallel connection of resistor which shunts the output ports. Experimental results show that this power divider suppresses from 1st to 9th harmonic components to less than -37dB, while maintaining the characteristics of a conventional Wilkinson power divider; featuring an equal power split, a simultaneous impedance matching at all ports and a good isolation between output ports. these results agree quite well with the simulation results.

  • PDF

초고층빌딩에 대한 고조파 시뮬레이션 및 실측데이터 분석 (Harmonic Simulation and Measurement Analysis for a Skyscraper)

  • 조수환;이한상;정재안;장길수;이경호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.265-266
    • /
    • 2008
  • The interest on harmonics which is one of the matters related with power quality problem is not limited in only the system where the large scale industrial load is connected. The harmonics phenomenon not only causes the malfunction of devices, but also lowers the energy efficiency of power system. This paper focuses on the harmonic analysis process to establish the harmonic mitigation method, considering the harmonics distortion as a major cause to reduce the energy efficiency of a skyscraper. A system diagram of building is modelled with PSCAD simulator. Based on the harmonic analysis results of it, the electrical locations with the high priority to install the mitigating devices are selected. Finally, the result of PSCAD simulations and the site-measured data are compared, verifying that they reach a common conclusion.

  • PDF

연료전지 전원을 갖는 Z-소스 능동전력필터에 의한 장거리 배전선로의 전압 THD 저감 (Voltage THD Mitigation of Power Distribution System using Z-Source Active Power Filter with a Fuel Cells Source)

  • 정영국
    • 전기학회논문지
    • /
    • 제57권12호
    • /
    • pp.2161-2166
    • /
    • 2008
  • This paper deals with a Z-source active power filter(Z-AFU) for mitigation voltage THD(total harmonic distortion) due to voltage harmonic propagation(amplification) in 6.6kv power distribution system. Bus voltage harmonic signal is detected by 60Hz butterworth BPF(band pass filter). As an ESS(energy storage system) of the proposed system, PEM fuel cells(Ballard NEXA, 1.2kw) is employed. Test results based on PSIM(power electronics simulation tool) validate the proposed approach.

Grid-friendly Control Strategy with Dual Primary-Side Series-Connected Winding Transformers

  • Shang, Jing;Nian, Xiaohong;Chen, Tao;Ma, Zhenyu
    • Journal of Power Electronics
    • /
    • 제16권3호
    • /
    • pp.960-969
    • /
    • 2016
  • High-power three-level voltage-source converters are widely utilized in high-performance AC drive systems. In several ultra-power instances, the harmonics on the grid side should be reduced through multiple rectifications. A combined harmonic elimination method that includes a dual primary-side series-connected winding transformer and selective harmonic elimination pulse-width modulation is proposed to eliminate low-order current harmonics on the primary and secondary sides of transformers. Through an analysis of the harmonic influence caused by dead time and DC magnetic bias, a synthetic compensation control strategy is presented to minimize the grid-side harmonics in the dual primary side series-connected winding transformer application. Both simulation and experimental results demonstrate that the proposed control strategy can significantly reduce the converter input current harmonics and eliminates the DC magnetic bias in the transformer.

An Enhanced PCC Harmonic Voltage Mitigation and Reactive Power Sharing in Islanded Microgrid

  • Pham, Minh-Duc;Lee, Hong-Hee
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2018년도 전력전자학술대회
    • /
    • pp.138-140
    • /
    • 2018
  • Parallel distributed generators (DGs) in the islanded microgrid are generally operated autonomously by means of the droop control scheme. However, the traditional droop control methods which use the P-${\omega}$ and Q-E curve to share power between DGs are still concerned to improve the accuracy of reactive power sharing. Moreover, the uncontrolled harmonic power reduces the point of common coupling (PCC) voltage quality and microgrid stability. In order to solve these problems, this paper proposes an enhanced PCC harmonic control strategy and an improved reactive power sharing control scheme. Based on the low bandwidth communications, a secondary control is implemented with both central controller and local controller. The effectiveness of the proposed control scheme is analyzed through the simulation.

  • PDF

3차 고조파 주입과 PR 제어기를 이용한 단상 PWM 컨버터의 커패시터 용량 저감 기법 (Capacitance reduction method for single-phase PWM converters using the 3rd harmonic injection and PR controller.)

  • 김규동;양현석;이동명
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2013년도 전력전자학술대회 논문집
    • /
    • pp.1-2
    • /
    • 2013
  • In this paper, we inject input currents having $3^{rd}$ harmonic to reduce the capacitance of DC link capacitors in single-phase converters. If the input current with third harmonic is injected, the required capacitance can be reduced by minimizing the difference between the input and output power. To control the input current, instead of PI control done in rotating frame, PR controller is used with the proposed separate current control method for fundamental and $3^{rd}$ harmonic components. The validity of the proposed method has been demonstrated by simulation results.

  • PDF