• 제목/요약/키워드: Harmonic Generation

검색결과 438건 처리시간 0.029초

고조파 장해의 진상에 관한 연구 (A Study on the Real Features of Harmonic Obstacle)

  • 이해기
    • 한국안전학회지
    • /
    • 제13권4호
    • /
    • pp.162-171
    • /
    • 1998
  • This paper presents the harmonics obstacle analysis and countermeasure of electrical consumption a place. Harmonics that can be cosidered as a environmental pollution of the power systems become the cause of the accidents and damages. The responsibility of eliminating the harmonics firstly lies on the generating side. But the original characteristics of the system sush as the harmonic transfer characteristics and the impedance of the system affect each other in the process of the generation and transmission of the harmonic. Therefore it is very difficult to specify clearly the harmonic controlling responsibility, because electric machinery generating harmonics are various in the industrial fields. The output of a inverter has a high harmonic content. There are several ways of minimizing the output harmonic content. One way is to use pulse width modulation techniques within inverter. An alternative method is to combine a number of square-wave inverters. In this research, we measure the harmonic of the countermeasure of electrical consumption a place. The paper present the problem of new harmonic elimination method of PWM inverter fed induction motor system using W-FT series. In the future, the proposed PWM pattern by W-FT series is effective not only to the induction motor but also to the electromagnetic machine such as voltage reglator, UPS.

  • PDF

A Novel Multi-Function PV Micro-Inverter with an Optimized Harmonic Compensation Strategy

  • Zhu, Guofeng;Mu, Longhua;Yan, Junhua
    • Journal of Power Electronics
    • /
    • 제16권6호
    • /
    • pp.2284-2293
    • /
    • 2016
  • With the rapid development of clean energy, photovoltaic (PV) generation has been utilized in the harmonic compensation of power systems. This paper presents a novel multi-function PV micro-inverter with three stages (pseudo-two-stage). It can inject active power and compensate harmonic currents in the power grid at the same time. In order to keep the micro-inverter working under the maximum allowable output power, an optimized capacity limitation strategy is presented. Moreover, the harmonic compensation can be adjusted according to the customized requirements of power quality. Additionally, a phase shedding strategy in the DC/DC stage is introduced to improve the efficiency of parallel Boost converters in a wide range. Compared with existing capacity limitation methods, the proposed strategy shows better performance and energy efficiency. Simulations and experiments verify the feasibility of the micro-inverter and the effectiveness of the strategy.

New Control Strategy for Conventional VSI in Islanded Microgrid to Enhance Voltage Quality under Nonlinear Loads

  • Dam, Duy-Hung;Lee, Hong-Hee
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2015년도 전력전자학술대회 논문집
    • /
    • pp.351-352
    • /
    • 2015
  • This paper proposed a new control strategy for voltage source inverter (VSI) of effective fifth and seventh harmonic reduction in the point of common coupling (PCC) in islanded microgrid under nonlinear load without any additional hardware devices. The non-linear load regularly causes such harmonic distortion, which harmfully affect the performance of other loads or other distributed generation (DG) sources connect to the PCC. In order to improve the quality of delivered output voltage, these harmonic must be rejected. The proposed control strategy is developed based on the current controller formed by resonant controller parallel with a proportional integral controller, which perform on the fundamental reference frame. The reference current is estimated based on the voltage harmonic and the injecting power. The simulation and experimental results are shown to verify the effectiveness of proposed control method.

  • PDF

분산전원 환경에서의 인근 수용가의 특정 수용가에 대한 고조파 영향 분석 (Analysis on the effect of harmonic loads on other loads in a distributed generation environment)

  • 송종석;변길성;황성철;장길수;한운기;박찬엄;고원식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.398-399
    • /
    • 2011
  • In this paper, an analysis is being performed on the effect of harmonics on loads in a distributed generation environment which includes renewable energy sources such as wind farms. The paper will assess the limits of the harmonic content that is allowed to be present in the adjacent loads while conforming to the distributed generation connection standards. The analysis is being performed in PSCAD/EMTDC where field measurements of wind data is being employed for the study.

  • PDF

Advanced Repetitive Controller to Improve the Voltage Characteristics of Distributed Generation with Nonlinear Loads

  • Trinh, Quoc-Nam;Lee, Hong-Hee
    • Journal of Power Electronics
    • /
    • 제13권3호
    • /
    • pp.409-418
    • /
    • 2013
  • This paper presents an enhanced control strategy which consists of a proportional-integral controller and a repetitive controller (RC) for improving the voltage performance of distributed generation (DG) under nonlinear load conditions. The proposed voltage controller is able to maintain a sinusoidal voltage at the point of common coupling (PCC) of the DG regardless of the harmonic voltage drop in the system impedance due to nonlinear load currents. In addition, by employing the delay time of the RC at one-sixth of the fundamental period, the proposed RC can overcome the slow response drawback of the traditional PI-RC. The proposed control strategy is analyzed and the design of the RC is presented in detail. The feasibility of the proposed control strategy is verified through simulation and experimental results.

디지털 록인 앰프를 이용한 비정현 계통 전압 하에서 강인한 단상계통 연계 인 버터용 고조파 보상법 (A Robust Harmonic Compensation Technique using Digital Lock-in Amplifier under the Non-Sinusoidal Grid Voltage Conditions for the Single Phase Grid Connected Inverters)

  • 칸 아마드 레이안;아쉬라프 모하마드 노만;최우진
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2018년도 추계학술대회
    • /
    • pp.95-97
    • /
    • 2018
  • The power quality of Single Phase Grid-Connected Inverters (GCIs) has received much attention with the increasing number of Distributed Generation (DG) systems. However, the performance of single phase GCIs get degraded due to several factors such as the grid voltage harmonics, the dead time effect, and the turn ON/OFF of the switches, which causes the harmonics at the output of GCIs. Therefore, it is not easy to satisfy the harmonic standards such as IEEE 519 and P1547 without the help of harmonic compensator. To meet the harmonic standards a certain kind of harmonic controller needs to be added to the current control loop to effectively mitigate the low order harmonics. In this paper, the harmonic compensation is performed using a novel robust harmonic compensation method based on Digital Lock-in Amplifier (DLA). In the proposed technique, DLAs are used to extract the amplitude and phase information of the harmonics from the output current and compensate it by using a simple PI controller in the feedforward manner. In order to show the superior performance of the proposed harmonic compensation technique, it is compared with those of conventional harmonic compensation methods in terms of the effectiveness of harmonic elimination, complexity, and implementation. The validity of the proposed harmonic compensation techniques for the single phase GCIs is verified through the experimental results with a 5kW single phase GCI. Index Terms -Single Phase Grid Connected Inverter (SPGCI), Harmonic Compensation Method, Total Harmonic Distortion (THD) and Harmonic Standard.

  • PDF

Single-Phase Multilevel PWM Inverter Based on H-bridge and its Harmonics Analysis

  • Choi, Woo-Seok;Nam, Hae-Kon;Park, Sung-Jun
    • Journal of Power Electronics
    • /
    • 제15권5호
    • /
    • pp.1227-1234
    • /
    • 2015
  • The efficient electric power demand management in electric power supply industry is currently being changed by distributed generation. Meanwhile, small-scale distributed generation systems using renewable energy are being constructed worldwide. Several small-scale renewable distributed generation systems, which can supply electricity to the grid at peak load of the grid as per policy such as demand response programs, could help in the stability of the electric power demand management. In this case, the power quality of the small-scale renewable distributed generation system is more significant. Low prices of power semiconductors and multilevel inverters with high power quality have been recently investigated. However, the conventional multilevel inverter topology is unsuitable for the small-scale renewable distributed generation system, because the number of devices of such topology increases with increasing output voltage level. In this paper, a single-phase multilevel inverter based on H-bridge, with DC_Link divided by bi-directional switches, is proposed. The proposed topology has almost half the number of devices of the conventional multilevel inverter topology when these inverters have the same output voltage level. Double Fourier series solution is mainly used when comparing PWM output harmonic components of various inverter topologies. Harmonic components of the proposed multilevel inverter, which have been analyzed by double Fourier series, are compared with those of the conventional multilevel inverter. An inverter prototype is then developed to verify the validity of the theoretical analysis.

대용량 연료전지시스템의 계통외란 방지알고리즘에 관한 연구 (A Study on the Countermeasure Algorithm for Power System Disturbances in Large Scale Fuel Cell Generation System)

  • 최성식;김병기;박재범;노대석
    • 전기학회논문지
    • /
    • 제65권5호
    • /
    • pp.711-717
    • /
    • 2016
  • Recently, fuel cell generation system with high energy efficiency and low CO2 emission is energetically interconnected with distribution power system. Especially, MCFC(molten carbonate fuel cell) operating at high temperature conditions is commercialized and installed as a form of large scale power generation system. However, it is reported that power system disturbances such as harmonic distortion, surge phenomenon, unbalance current, EMI(Electromagnetic Interference), EMC (Electromagnetic Compatibility) and so on, have caused several problems including malfunction of protection device and damage of control devices in the large scale FCGS(Fuel Cell Generation System). Under these circumstances, this paper proposes countermeasure algorithms to prevent power system disturbances based on the modelling of PSCAD/EMTDC and P-SIM software. From the simulation results, it is confirmed that proposed algorithms are useful method for the stable operation of a large scale FCGS.

선형 및 비선형 초음파를 이용한 1Cr-1Mo-0.25V의 열화평가에 관한 연구 (A Study on the Evaluation of Material Degradation for 1Cr-1Mo-0.25V Steel using Linear and Nonlinear Ultrasonics)

  • 김정표;석창성;송성진;김영환
    • 비파괴검사학회지
    • /
    • 제21권5호
    • /
    • pp.549-555
    • /
    • 2001
  • 초음파법은 산업설비의 열화 정도나 결함을 평가하기 용이한 비파괴적 방법이다. 본 연구에서는 1Cr-1Mo-0.25V을 $630^{\circ}C$에서 등온열화처리하여 4개의 시편을 준비하였다. 이를 사용하여 초음파의 속도, 감쇠계수를 측정하여 재료의 열화를 평가하였으며, 배진동의 발생효률을 나타내는 비선형파라미터를 이용하여 재료의 열화정도를 평가하였다. 감쇠계수와 비선형파라미터는 열화가 진행될 수록 증가하였으며, 특히 1,820 시간 열화시편의 배진동 진폭은 원시시편의 배진동 진폭과 비교 시 20dB이상 증가하였나. 그러나 열화정도에 따른 속도의 변화는 거의 없는 것으로 나타났다. 본 연구결과에서 감쇠계수와 비선형파라미터는 재질 열화에 민감하게 반응하는 파라미터였으며, 재질 열화도를 평가하기에 적절한 파라미터인 것으로 사료된다.

  • PDF

조화상수를 이용한 조위 발생확률분포 분석 (Analysis on the Occurrence Probability Distribution of Tidal Levels using Harmonic Constants)

  • 정신택;조홍연;김정대;조범준
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2005년도 학술발표회 논문집
    • /
    • pp.1053-1057
    • /
    • 2005
  • The occurrence probability (OP) distributions of tide levels using harmonic constants of six tidal gauging stations in Korean coastal zone were estimated and analysed in detail. OP analysis using harmonic constants data of Incheon(Youldo), Mokpo, Yeosu, Pusan, Pohang and Sokcho was carried out and compared with the OP using hourly tidal elevation data which were served through the Internet Homepage by the National Ocean Research Institute. The tidal elevation data were divided by the AHHW (ALLW) value referenced to MSL in order to compare the OP patterns in a relative scale. The OP of the tidal elevation calculated using 38 harmonic tidal constituents relatively well agreed with those of hourly observed tidal elevation data. However, the OP results using four harmonic tidal constituents overestimate the occurrence probability at the peak points and underestimate at the tail-regions of the OP. Especially, the OP patterns of the Sokcho and Pohang tidal gauging stations on the East Sea show totally different patterns and the estimation method using four harmonic constants should be modified and application should be strictly limited on the East Sea areas. The OP patterns are considerably well generated in case of the OP generation using the additional two or three dominant tidal constituents,

  • PDF