• Title/Summary/Keyword: Harmonic

Search Result 5,140, Processing Time 0.042 seconds

A Study on the Analysis of Damping Loads to Prevent Harmonic Resonance (고조파 공진 억제를 위한 완충부하 투입량 분석에 관한 연구)

  • Lim, Chan-Ho;Lee, Kyeong-Seob;Yu, Won-Kun;Lee, Heung-Jae
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.2
    • /
    • pp.262-266
    • /
    • 2010
  • During the restoration process of primary restorative transmission system, the over voltage may happen due to nonlinear interaction between the unloaded transformer and the transmission system. This over voltage is caused by harmonic resonance and can be prevented by damping loads that are connected before restoration process of primary restorative transmission system. But it is very difficult to predict the occurrence possibility of the harmonic resonance previously. This paper analyzes the relationship between the harmonic resonance and the amount of damping loads to prevent the harmonic resonance. This paper calculates the minimum amount of damping loads to prevent harmonic resonance while changing the length of primary restorative transmission line. And this paper confirmed that the amount of damping loads is not proportional to length of transmission line. The result of this paper will be used as important experiment data to predict the occurrence possibility of harmonic resonance previously.

Harmonic Current Compensation Method Using Inverter-Interfaced Distributed Generators (인버터 연계형 분산전원을 이용한 배전계통 고조파 전류 보상원리)

  • Chung, Il-Yop;Kang, Hyun-Koo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.2
    • /
    • pp.279-284
    • /
    • 2011
  • Harmonic distortions in current waveform may cause significant problems in electric power system facility and operation. This paper presents an adaptive parameter estimation method to detect harmonic current components caused by nonlinear loads. In addition, a coordination strategy for multiple inverter-interfaced distributed generators to compensate the harmonic currents is discussed. The coordination strategy is realized by distributing the harmonic compensation participation index to individual distributed generators. The harmonic compensation participation index can be determined by the amount of remaining power generation capacity of each distributed generator. Simulation results based on switching-level inverter models show that the proposed harmonic detection method has good performance and the coordination strategy can improve harmonic problems efficiently.

Novel Third Harmonic Current Injection Technique for Harmonic Reduction of Controlled Converters

  • Eltamaly, Ali M.
    • Journal of Power Electronics
    • /
    • v.12 no.6
    • /
    • pp.925-934
    • /
    • 2012
  • Three-phase controlled converters have many applications in the utility interfacing of renewable energy sources and adjustable speed drives as a rectifier or inverter. The utility line currents of these converters have a high harmonic distortion, which is more than the harmonic standards. This paper introduces a new technique for circulating the third harmonic currents from the dc-link to the line currents to reduce their harmonic contents. The proposed system uses a single-phase PWM converter to control the angle and amplitude of the injection current for each of the firing angle of a three-phase converter. A detailed analysis is introduced to achieve a relationship between the firing angle of the three-phase controlled converter and the power angle of the PWM converter. In addition, a detailed design for the other injection path components is introduced. A simulation and experimental work is introduced to prove the mathematical derivations. Analysis, simulation and experimental results prove the superiority of the proposed technique.

Design and Development of Harmonic Power Source Control Module (고조파 전원발생장치의 제어기 설계 및 개발)

  • Lee, S.I.;Yoo, J.G.;Jeon, J.C.;Jeon, H.J.;Heo, H.S.;Choe, G.H.
    • Proceedings of the KIPE Conference
    • /
    • 2007.07a
    • /
    • pp.40-42
    • /
    • 2007
  • Recently the harmonic generation has deteriorated the quality of electricity and affected the performance on the electrical installation including personal computer, fax, community devices and so on. Some studies of harmonic affects in diagnosis and the cause of accident has not done by the experimental data of harmonic source but merely by presumption according to qualitative analysis. So, in order to research the harmonic affect on the electrical installation according to quantitative analysis and gather reliable data over and over again, it is necessary to develop an Harmonic power source which is capable of generating some harmonics. In this paper, we described about realization of Harmonic power source control module which can produce and added harmonics for the analysis due to harmonic effects.

  • PDF

A Proposal of Compact Passive Harmonic Filter for ac Motor Drive (고성능 콤팩트형 AC모터드라이브 고조파 필터 제안)

  • Park, Byung-Ju;Yoon, Dong-Chul;Oh, Jeong-Cheol;Bae, Byung-Yeol;Hwang, An-Il;Yoo, Hang-Kyu;Choi, Seok-Keun
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.67 no.4
    • /
    • pp.191-199
    • /
    • 2018
  • The harmonic reduction method of ac motor drive, ACL and DCL were commonly used, but the current distortion ratio was only 35%, thus the several different types of filters as BBHF(broad band harmonic filter), HHF(hybrid harmonic filter), NHHF(new hybrid harmonic filter) have been developed to satisfy the IEEE Std. 519 harmonic limitation. However, these filters had been limited marketability due to cost and size problems. This study suggests the methods to reduce cost and size of the harmonic filter including topologies, besides we discussed simulation results of the power system with regard to the implementation and performance of the filters.

Characteristic Analysis of Axial Magnetic Harmonic Gear (액시얼 마그네틱 하모닉 기어의 특성 해석)

  • Won, Hunhee;Jung, Kwangsuk
    • Journal of Institute of Convergence Technology
    • /
    • v.10 no.1
    • /
    • pp.25-29
    • /
    • 2020
  • Magnetic gears of non-contact power type have great advantages in terms of maintenance and repair than mechanical gears, and are used in various ways. Harmonic gears can derive a higher gear ratio than conventional gears through power transmission through a unique rotation mechanism. Magnetic harmonic gears, in which the gear teeth of the harmonic gears are replaced with magnets, have the advantages of both gears, but are difficult to implement and practical, so many studies are being conducted. In this study, we check whether the results of various types of magnetic gears can be applied to harmonic gears. By applying the axial type magnetic gear to the harmonic gear, the characteristic analysis is conducted to see if the result comparable to the existing radial type magnetic harmonic gear is obtained.

A Study on the downconverter Using Sub-Harmonic Mixer for Point to Point System Applications (Sub-Harmonic 혼합기를 이용한 점대점 시스템용 하향 변환기에 관한 연구)

  • Min Jun-Ki;Kim Hyun-Jin;Kim Yong-Hwan;Yoo Hyung-Soo;Yun Ho-Seok;Lee Keun-Tae;Hong Ui-Seok
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.30 no.10A
    • /
    • pp.958-964
    • /
    • 2005
  • In this thesis, the matching network at the local oscillator port of the sub-harmonic mixer is optimized for reducing the conversion loss. A downconverter for point to point system applications is designed and fabricated using the such sub-harmonic mixer. The sub-harmonic mixer achieved the conversion loss of 11.8 dB at the 12 dBm input power of the local oscillator and the isolation of less than -40 dB. The downconverter achieved the IF output power flatness of 2 dB and the total noise figure of 5.9 dB.

Probabilistic Method for The Harmonic Analysis of Railroad Feeding System (철도급전시스템의 고조파 평가를 위한 확률론적 방법)

  • Lee, Seung-Hyuk;Song, Hak-Seon;Lee, Jun-Kyong;Kim, Jin-O
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.55 no.9
    • /
    • pp.384-391
    • /
    • 2006
  • The harmonic currents generated along with the operating speed of electrical railroad traction are very difficult to analyze because of its nonlinear characteristics. This paper therefore presents probabilistic approach for the evaluation of harmonic currents about the operating speed of the arbitrary single traction. To use probabilistic method for railroad system, PDF(Probability Density Function) using measuring data based on the realistic h 따 monic currents per operating speed is calculated. Measuring data of harmonic current per operating speed is obtained using the result data of PSCAD/EMTDC dynamic simulation based on an IAT(Intra Airport Transit) in Incheon International Airport. The means(expected values) and variances of harmonic currents of single traction also are obtained by the PDF of the operating traction speed and harmonic currents. The uncertainty of harmonic currents can be calculated through the mean and variance of PDF. The probability of harmonic currents generated with the operating of arbitrary many tractions is calculated by the convolution of functions. The harmonics of different number of tractions are systematically investigated to assess the TDD(Total Demand Distortion) for the railroad system. The calculation of TDD was carried out using Monte-Carlo Simulations(MSCs) and the results of TDD evaluation of the power quality in the IAT power feeding system.

Research on Fourth Harmonic Mixer at W Band in the Imaging System

  • Xiang, Bo;Dou, Wenbin;He, Minmin;Wang, Zongxin
    • Journal of electromagnetic engineering and science
    • /
    • v.10 no.4
    • /
    • pp.316-321
    • /
    • 2010
  • This paper presents a novel fourth harmonic mixer with new structure. The traditional 3-ports fourth harmonic mixer and the novel fourth harmonic mixer are designed by ADS, HFSS and CST simulator. The mixers have been fabricated and tested. The size of the traditional 3-ports fourth harmonic mixer is $12{\times}15$ mm, and the best conversion loss is 18.7 dB according to the measurement. Since the traditional 3-port mixer size is too large to be ranked, we design a novel fourth harmonic mixer for imaging system. The width of the mixing module in the novel fourth harmonic mixer is only 3.65 mm, and this size is fully capable to meet the mixer unit space which is not greater than 5 mm. The simulation result shows that the mixer has good performance, and the experiment result shows that the best conversion loss of the novel fourth harmonic mixer is 16.3 dB at RF signal of 91.3 GHz.

The Performance Comparison of The Harmonic Generators using Nonlinear Transmission Lines (비선형 전송선로를 이용한 고조파 발생기 성능 비교)

  • Park, Soonwoo;Kim, Hongjoon;Yoo, Hyoungsuk
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.8
    • /
    • pp.1212-1216
    • /
    • 2015
  • In this paper, we compared the performance of the Right Handed Nonlinear Transmission Line (RH-NLTL) and Left Handed Nonlinear Transmission Line (LH-NLTL) as a harmonic generator. For a performance comparison, we fabricated both a RH-NLTL and a LH-NLTL harmonic generator whose operational bandwidth is from 0.5 GHz to 1.5 GHz. Under the each condition for the RH-NLTL and the LH-NLTL to maximize second harmonic, the output power of the second harmonic was 9.33 dB lower than the input power for the RH-NLTL and 12.67 dB lower than the input power for the LH-NLTL. Under the each condition for the RH-NLTL and the LH-NLTL to maximize third harmonic, the output power of the third harmonic was 13.33 dB lower than the input power for the RH-NLTL and 14.83dB lower than the input power for the LH-NLTL. Also, we have observed that, generatlly, a RH-NLTL is useful in generating various multiple harmonics and a LH-NLTL is useful in generating a specific order of harmonic by adjusting a proper DC vias, input frequency and input power. These tendencies could be a good guideline to use NLTLs as a frequency multiplier.