• 제목/요약/키워드: Harmonic

검색결과 5,155건 처리시간 0.035초

고조파 공진 억제를 위한 완충부하 투입량 분석에 관한 연구 (A Study on the Analysis of Damping Loads to Prevent Harmonic Resonance)

  • 임찬호;이경섭;유원근;이흥재
    • 전기학회논문지
    • /
    • 제59권2호
    • /
    • pp.262-266
    • /
    • 2010
  • During the restoration process of primary restorative transmission system, the over voltage may happen due to nonlinear interaction between the unloaded transformer and the transmission system. This over voltage is caused by harmonic resonance and can be prevented by damping loads that are connected before restoration process of primary restorative transmission system. But it is very difficult to predict the occurrence possibility of the harmonic resonance previously. This paper analyzes the relationship between the harmonic resonance and the amount of damping loads to prevent the harmonic resonance. This paper calculates the minimum amount of damping loads to prevent harmonic resonance while changing the length of primary restorative transmission line. And this paper confirmed that the amount of damping loads is not proportional to length of transmission line. The result of this paper will be used as important experiment data to predict the occurrence possibility of harmonic resonance previously.

인버터 연계형 분산전원을 이용한 배전계통 고조파 전류 보상원리 (Harmonic Current Compensation Method Using Inverter-Interfaced Distributed Generators)

  • 정일엽;강현구
    • 전기학회논문지
    • /
    • 제60권2호
    • /
    • pp.279-284
    • /
    • 2011
  • Harmonic distortions in current waveform may cause significant problems in electric power system facility and operation. This paper presents an adaptive parameter estimation method to detect harmonic current components caused by nonlinear loads. In addition, a coordination strategy for multiple inverter-interfaced distributed generators to compensate the harmonic currents is discussed. The coordination strategy is realized by distributing the harmonic compensation participation index to individual distributed generators. The harmonic compensation participation index can be determined by the amount of remaining power generation capacity of each distributed generator. Simulation results based on switching-level inverter models show that the proposed harmonic detection method has good performance and the coordination strategy can improve harmonic problems efficiently.

Novel Third Harmonic Current Injection Technique for Harmonic Reduction of Controlled Converters

  • Eltamaly, Ali M.
    • Journal of Power Electronics
    • /
    • 제12권6호
    • /
    • pp.925-934
    • /
    • 2012
  • Three-phase controlled converters have many applications in the utility interfacing of renewable energy sources and adjustable speed drives as a rectifier or inverter. The utility line currents of these converters have a high harmonic distortion, which is more than the harmonic standards. This paper introduces a new technique for circulating the third harmonic currents from the dc-link to the line currents to reduce their harmonic contents. The proposed system uses a single-phase PWM converter to control the angle and amplitude of the injection current for each of the firing angle of a three-phase converter. A detailed analysis is introduced to achieve a relationship between the firing angle of the three-phase controlled converter and the power angle of the PWM converter. In addition, a detailed design for the other injection path components is introduced. A simulation and experimental work is introduced to prove the mathematical derivations. Analysis, simulation and experimental results prove the superiority of the proposed technique.

고조파 전원발생장치의 제어기 설계 및 개발 (Design and Development of Harmonic Power Source Control Module)

  • 이상익;유재근;전정채;전현재;허혜성;최규하
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2007년도 하계학술대회 논문집
    • /
    • pp.40-42
    • /
    • 2007
  • Recently the harmonic generation has deteriorated the quality of electricity and affected the performance on the electrical installation including personal computer, fax, community devices and so on. Some studies of harmonic affects in diagnosis and the cause of accident has not done by the experimental data of harmonic source but merely by presumption according to qualitative analysis. So, in order to research the harmonic affect on the electrical installation according to quantitative analysis and gather reliable data over and over again, it is necessary to develop an Harmonic power source which is capable of generating some harmonics. In this paper, we described about realization of Harmonic power source control module which can produce and added harmonics for the analysis due to harmonic effects.

  • PDF

고성능 콤팩트형 AC모터드라이브 고조파 필터 제안 (A Proposal of Compact Passive Harmonic Filter for ac Motor Drive)

  • 박병주;윤동철;오정철;배병열;황안일;유항규;최석근
    • 전기학회논문지P
    • /
    • 제67권4호
    • /
    • pp.191-199
    • /
    • 2018
  • The harmonic reduction method of ac motor drive, ACL and DCL were commonly used, but the current distortion ratio was only 35%, thus the several different types of filters as BBHF(broad band harmonic filter), HHF(hybrid harmonic filter), NHHF(new hybrid harmonic filter) have been developed to satisfy the IEEE Std. 519 harmonic limitation. However, these filters had been limited marketability due to cost and size problems. This study suggests the methods to reduce cost and size of the harmonic filter including topologies, besides we discussed simulation results of the power system with regard to the implementation and performance of the filters.

액시얼 마그네틱 하모닉 기어의 특성 해석 (Characteristic Analysis of Axial Magnetic Harmonic Gear)

  • 원훈희;정광석
    • 융복합기술연구소 논문집
    • /
    • 제10권1호
    • /
    • pp.25-29
    • /
    • 2020
  • Magnetic gears of non-contact power type have great advantages in terms of maintenance and repair than mechanical gears, and are used in various ways. Harmonic gears can derive a higher gear ratio than conventional gears through power transmission through a unique rotation mechanism. Magnetic harmonic gears, in which the gear teeth of the harmonic gears are replaced with magnets, have the advantages of both gears, but are difficult to implement and practical, so many studies are being conducted. In this study, we check whether the results of various types of magnetic gears can be applied to harmonic gears. By applying the axial type magnetic gear to the harmonic gear, the characteristic analysis is conducted to see if the result comparable to the existing radial type magnetic harmonic gear is obtained.

Sub-Harmonic 혼합기를 이용한 점대점 시스템용 하향 변환기에 관한 연구 (A Study on the downconverter Using Sub-Harmonic Mixer for Point to Point System Applications)

  • 민준기;김현진;김용환;유형수;윤호석;이근태;홍의석
    • 한국통신학회논문지
    • /
    • 제30권10A호
    • /
    • pp.958-964
    • /
    • 2005
  • 본 논문은 Sub-harmonic 혼합기 구조에서 국부발진기(Local Oscillator) 포트에 넓은 대역에 걸쳐서 변환손실을 최적화 하는 정합회로를 적용하였다. 이러한 Sub-harmonic 혼합기를 이용하여 점대점 시스템용 하향 변환기를 설계 및 제작하였다. 제안된 구조의 Sub-harmonic 혼합기는 국부발진기입력전력이 12 dBm일 때 최적으로 11.8 dB의 변환손실을 얻었으며, 격리특성은 40dB이하의 특성을 나타내었다. 전체 하향 변환기의 특성으로 IF 출력 평탄도는 2dB이하의 특성을 나타내었으며, 전체 잡음지수로는 5.9dB이하의 특성을 얻었다.

철도급전시스템의 고조파 평가를 위한 확률론적 방법 (Probabilistic Method for The Harmonic Analysis of Railroad Feeding System)

  • 이승혁;송학선;이준경;김진오
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제55권9호
    • /
    • pp.384-391
    • /
    • 2006
  • The harmonic currents generated along with the operating speed of electrical railroad traction are very difficult to analyze because of its nonlinear characteristics. This paper therefore presents probabilistic approach for the evaluation of harmonic currents about the operating speed of the arbitrary single traction. To use probabilistic method for railroad system, PDF(Probability Density Function) using measuring data based on the realistic h 따 monic currents per operating speed is calculated. Measuring data of harmonic current per operating speed is obtained using the result data of PSCAD/EMTDC dynamic simulation based on an IAT(Intra Airport Transit) in Incheon International Airport. The means(expected values) and variances of harmonic currents of single traction also are obtained by the PDF of the operating traction speed and harmonic currents. The uncertainty of harmonic currents can be calculated through the mean and variance of PDF. The probability of harmonic currents generated with the operating of arbitrary many tractions is calculated by the convolution of functions. The harmonics of different number of tractions are systematically investigated to assess the TDD(Total Demand Distortion) for the railroad system. The calculation of TDD was carried out using Monte-Carlo Simulations(MSCs) and the results of TDD evaluation of the power quality in the IAT power feeding system.

Research on Fourth Harmonic Mixer at W Band in the Imaging System

  • Xiang, Bo;Dou, Wenbin;He, Minmin;Wang, Zongxin
    • Journal of electromagnetic engineering and science
    • /
    • 제10권4호
    • /
    • pp.316-321
    • /
    • 2010
  • This paper presents a novel fourth harmonic mixer with new structure. The traditional 3-ports fourth harmonic mixer and the novel fourth harmonic mixer are designed by ADS, HFSS and CST simulator. The mixers have been fabricated and tested. The size of the traditional 3-ports fourth harmonic mixer is $12{\times}15$ mm, and the best conversion loss is 18.7 dB according to the measurement. Since the traditional 3-port mixer size is too large to be ranked, we design a novel fourth harmonic mixer for imaging system. The width of the mixing module in the novel fourth harmonic mixer is only 3.65 mm, and this size is fully capable to meet the mixer unit space which is not greater than 5 mm. The simulation result shows that the mixer has good performance, and the experiment result shows that the best conversion loss of the novel fourth harmonic mixer is 16.3 dB at RF signal of 91.3 GHz.

비선형 전송선로를 이용한 고조파 발생기 성능 비교 (The Performance Comparison of The Harmonic Generators using Nonlinear Transmission Lines)

  • 박순우;김홍준;유형석
    • 전기학회논문지
    • /
    • 제64권8호
    • /
    • pp.1212-1216
    • /
    • 2015
  • In this paper, we compared the performance of the Right Handed Nonlinear Transmission Line (RH-NLTL) and Left Handed Nonlinear Transmission Line (LH-NLTL) as a harmonic generator. For a performance comparison, we fabricated both a RH-NLTL and a LH-NLTL harmonic generator whose operational bandwidth is from 0.5 GHz to 1.5 GHz. Under the each condition for the RH-NLTL and the LH-NLTL to maximize second harmonic, the output power of the second harmonic was 9.33 dB lower than the input power for the RH-NLTL and 12.67 dB lower than the input power for the LH-NLTL. Under the each condition for the RH-NLTL and the LH-NLTL to maximize third harmonic, the output power of the third harmonic was 13.33 dB lower than the input power for the RH-NLTL and 14.83dB lower than the input power for the LH-NLTL. Also, we have observed that, generatlly, a RH-NLTL is useful in generating various multiple harmonics and a LH-NLTL is useful in generating a specific order of harmonic by adjusting a proper DC vias, input frequency and input power. These tendencies could be a good guideline to use NLTLs as a frequency multiplier.