• 제목/요약/키워드: Harmful air

검색결과 419건 처리시간 0.025초

팽창률이 일정한 노즐을 사용한 AIR-KNIFE 유동에 관한 연구 (A STUDY ON THE FLOW CHARACTERISTICS OF AIR-KNIFE USING A CONSTANT EXPANSION RATE NOZZLE)

  • 이동원;강남철;김근영;권영두;권순범
    • 한국전산유체공학회지
    • /
    • 제13권4호
    • /
    • pp.1-7
    • /
    • 2008
  • In the process of continuous hot-dip galvanizing, it is well known that the gas wiping through an air knife system is most effective because of its uniformity in coating thickness, possibility of thin coating, workability in high speed, and simplicity of control. However, gas wiping used in the galvanizing process brings about a problem of splashing at the strip edge above a certain high speed of process. It is also known that the problem of edge splashing is more harmful than that at the mid strip surface. For a given liquid(of a certain viscosity and surface tension), the onset of splashing mainly depends upon the strip velocity, the gas-jet pressure, and the nozzle's stand-off distance. In these connections in the present study, we proposed three kinds of air knife system having nozzles of constant expansion rate, and compared the jet structures issuing from newly proposed nozzle systems with the result by a conventional one. In numerical analysis, the governing equations are consisted of two-dimensional time dependent Navier-Stokes equations, and the standard k-${\varepsilon}$ turbulence model is employed to solve turbulence stress and so on. As the result, it is found that we had better use the constant expansion-rate nozzle which can be interpreted from the point view of the energy saving for the same coating thickness. Also, we better reduce the size of separation bubble and enhance the cutting ability at the strip surface, by using an air-knife having constant expansion-rate nozzle.

치과기공사들의 건강관리 실태 및 인식수준에 관한 조사 연구 (A Study on the Health Management of Dental Technicians and Their Awareness of the Same)

  • 최운재
    • 대한치과기공학회지
    • /
    • 제22권1호
    • /
    • pp.113-128
    • /
    • 2000
  • The purpose of this study was to serve as a basis for the development of dental technology and for creating a condition that dental technicians could work with pride and right values, by examining what problems there were in their health care, what they thought about them, and how the problems could be solved, The findings of this study were as below: 1. The most serious and harmful element in dental technology workshop was a dust(57.5%) and a noise(33.3%). 2. Approximately 99.0% of the dental technicians investigated made a complain of air pollution caused by noise. Their opinion on a possible measure to remove noise air pollution was that the noise-generating machine should be replaced(64.1%) or that it should be isolated(28.8%). 3. 76.0% complained air pollution cause by dust deteriorates their working efficiency. As a way to eliminate it, they suggested a dust chamber(35.3%) or an air cleaner(27.5%) should be installde. 4. About 80% made a complain of gas air pollution. The most common related symptom was a headache(56.9%). They thought that gas-generating machine should be isolated(39.9%) or that an air purifier should be prepared(33.3%). 5. The largest impact of heat and light on their body was weakening their eyesight(56.9%). 47.1% got burn once though four times, and 34.3% did five times or more. The way to prevent them was to install an automatic casting machine(66.0%) or use protective glasses(28.1%). 6. Approximately 47.7% were considering a change of occupation, and the most common reason was heavy work(23.5%), followed by poor prospect(21.6%) and working environment(19.0%) in the order named. 7. 88.9% responded they were likely to have an occupational disease. Their idea about the proper frequency of regular health examination was once a year(53.6%), or once per every six months(41.8%). 8. The field they were most interested in was health care(39.2%), followed by academic research activities(31.4%). This fact indicated it's most urgently required to improve their working environment.

  • PDF

PI와 피드포워드 제어를 이용한 공작기계용 오일쿨러의 핫가스 바이패스 방식 정밀 온도 제어 (Precise Temperature Control of Oil Coolers with Hot-gas Bypass Manner for Machine Tools Based on PI and Feedforward Control)

  • 정석권;변종영;김상호;윤정인
    • 설비공학논문집
    • /
    • 제23권2호
    • /
    • pp.111-119
    • /
    • 2011
  • Recently, the performances of speed and accuracy are enhanced in machine tools. The high speed of the machine tools usually causes harmful thermal displacements on the objects. To reduce the thermal displacements, machine tools generally adopt oil coolers with precise temperature control function. This study aims at precise control of oil outlet temperature in the oil coolers with hot-gas bypass manner based on PI control logic. The control system was designed for obtaining steady state error within ${\pm}0.1^{\circ}C$ and maximum overshoot with 0.8% even though abrupt disturbances are added to the system. We showed that the PI gains could be easily decided by numerical simulations using practical transfer function which got experiments. Also, transient characteristics could be improved significantly by reflecting the inlet temperature of an evaporator to the output of a controller feedforwardly considering periodic abrupt disturbances. Through some experiments, excellent control performances were established by the suggested control.

가스상 대기오염물질에 의한 종이 기록물의 가속열화 특성 연구 (Studies on the Accelerated Aging Characteristics of Paper Records by Gaseous Air Pollutants)

  • 정소윤;전수연;백소라;정현석;이진희;김형진
    • 펄프종이기술
    • /
    • 제47권4호
    • /
    • pp.151-159
    • /
    • 2015
  • Paper records were generally degraded by some factors from atmospheric environments, like temperature, relative humidity or air pollutants. In this study, the degradation behavior of paper records by single or mixed gases of $NO_2$, $SO_2$, HCHO and TVOC was evaluated. The mechanical, optical and chemical properties of 4 kinds of paper (acid and neutral-based printing paper, traditional Hanji, and filter paper) were directly and indirectly affected by gaseous harmful materials. The brightness and $L^*$ value in all papers were slightly increased by accelerated aging under gaseous HCHO and TVOCs, but highly decreased by conditions under gases $NO_2$ and $SO_2$. The optical properties of paper records were most vulnerable in acid-based paper and high stable in filter paper and traditional Hanji by air pollutant degradation. The aging treatments under mixed gas pollutants including $NO_2$ resulted in decrease of physical, mechanical and optical properties of paper, so it was supposed that the concentration of $NO_2$ gas would be strictly controlled for optimum indoor air quality management in domestic storage centers for paper records.

핫가스 바이패스 및 압축기 가변속 제어에 의한 공작기계용 수냉각기의 성능 비교 (Comparison of System Performances of Hot-gas Bypass and Compressor Variable Speed Control of Water Coolers for Machine Tools)

  • 정석권;이단비;윤정인
    • 설비공학논문집
    • /
    • 제24권1호
    • /
    • pp.1-8
    • /
    • 2012
  • Recently, the needs of system performances such as working speed and processing accuracy in machine tools have been increased. Especially, the speed increment generates harmful heat at both moving part of the machine tools and handicrafts. The heat is a main drawback to progress accuracy of the processing. Hence, a cooler system to control temperature is inevitable for the machine tools. In general, two representative control schemes, hot-gas bypass and variable speed control of a compressor, have been adopted in the water cooler system. In this paper, comparisons of system performances according to the control schemes in a cooler for machine tools were conducted in detail. Each proportional-integral feedback controller for the two different control systems is designed. The system performances, especially the temperature control accuracy and coefficient of performance which is a criterion of energy saving, were mainly analyzed through various experiments using 1RT water cooler system with different two types of control scheme. These evaluations will provide useful information to choose suitable water cooler system for the engineers who design controllers of the cooler system for machine tools.

WA 숫돌을 이용한 원통 연삭 시 압축냉각공기와 연삭유의 냉각효과에 관한 연구 (A Comparison of the Cooling Effects for the Compressed Cold Air and Coolant on the Cylindrical Grinding with WA Wheel)

  • 이석우;최헌종;정해도
    • 한국정밀공학회지
    • /
    • 제17권10호
    • /
    • pp.155-161
    • /
    • 2000
  • Recently, environmental pollution has become a big problem in industry and many researches have been done in order to preserve the environment. In the grinding process, the coolant has great influence on environment. It contains several chemicals(sulfur, phosphorus and chlorine) to improve the grinding efficiency. If these additives go into the workplace atmosphere, it is harmful for workers. It can also cause the environment pollution. Because of these reasons many studies have been done to minimize the amount of coolant. However the small amount of coolant can cause the thermal defect on the ground surface layer. This study forced the effects of the compressed cold air when the spindle shaft materials(SCM4 & SCM21) were cylindrical ground with WA wheel. The compressed cold air was used as the coolant and grinding performance was compared with that of the conventional grinding fluids(emulsion). Many experiments were carried out with these two cooling materials. The surface roughness, residual stress, and roundness were measured for the cylindrical grinding. The test results showed that the compressed cold air was very useful as the cooling materials for grinding process. It was also efficient to minimize the thermal defects of workpiece and could also play a role in solving environmental pollution.

  • PDF

호흡성분진중의 중금속 오염도에 관한 조사연구 (A Study of Heavy Metal Pollutants in the Respirable Dust in Seoul Area)

  • 임영욱;정용
    • 한국대기환경학회지
    • /
    • 제5권1호
    • /
    • pp.68-78
    • /
    • 1989
  • The heavy metal of suspended particulates with human health has long been studied in environmental interest concerned. This study was intended to identify harmful heavy metals of the ambient air borne dusts which were related with the respirable sizes in the aerodynamics. Two sampling sites were selected comparatively; one was in the Shinchon area, which is the commercial district with heavy traffic and the other site was in the Bulgwang area which is residential area. The supended particulates were sampled by high volume air sample with 6 cascade impactor stages. The heavy metals in terms of As, Cd, Cr, Cu, Fe, Hg, Mn, Ni, Pb, Se, V and Zn were determined by stomic absorption spectrometry or inductively coupled plasma emission spectrometry. The samples weretaken bimothly for seven consecutive days from May 1987 to March 1988. The annual average concentration of the respirable suspended dust of which diameter is less than 10$\mum$ was 152.59 $\mug/m^3$ of the Shinchon air samples; the respirable dust was equivalent to approximately 85% of the total suspended particulates. The annual average concentration of the respirable suspended dust of the Bulgwang air samples was 112.56 $\mug/m^3$; that was approximately 86% of the total suspended particulates. The concentration of heavy metals was investigated in relation to the particle size. The concentration of Cr, Fe, Mn and V were tended to be much more in the coarse particles than in the fine particles. Cd and Pb in the fine particles were more than in the coarse particles. In the partial correlation coefficients; in the Shinchon area, high correlations among Fe, Se and Mn were determined; it is assumed that those sources would be originated from coal, gasolineand diesel. In Bulgwang area, would be high correlation among Fe, Se, Hg and Mn considered to be originated from coal, Bunker-C and heavy oil as well. From the above results, the hazardous heavy merals in air should be measured and controlled in originally their sources.

  • PDF

The Analysis of Correlation between BVOCs and Ozone at Taehwa Research Forest

  • Kim, Dan-Bi;Lee, Sang-Deok;Lee, Seung-Ha;Kim, Rhok-Ho;Lee, Yeong-Jae;Chae, Hee-Mun
    • Journal of Forest and Environmental Science
    • /
    • 제34권2호
    • /
    • pp.153-161
    • /
    • 2018
  • Ozone absorbs ultraviolet light which is harmful to life. However, the recent increase of ambient ozone level due to climate change is becoming the cause of stimulating human eyes, affecting respiratory system, and damaging crops. In this paper, a study was conducted at the Taehwa Research Forest (TRF) of Seoul National University with the purpose of analyzing the characteristics of forest air chemistry based on the measurement of BVOCs emitted from forests and investigating the correlation of BVOCs with ozone generation. The results showed that levels of isoprene and MVK (Methyl Vinyl Keton)+MACR (Methacrolein) were high in summer, but level of monoterpene was high in spring. Ozone level was high from the middle of May to the middle of June, which was before the rainy season. Comparison of the correlation between ozone and isoprene during the measurement period at the TRF showing limited NOx showed that the $R^2$ was correlated with a low value of about 0.4. However, when the isoprene was actively produced from 6:00 AM to 6:00 PM, correlation analysis showed that $R^2$ was about 0.9, while monoterpene started to increase in the afternoon, and decreased level of ozone at night. Correlation analysis showed negative correlation. Forests have two characteristics: not only the formation of ozone but also the decomposition of ozone.

이동 측정방법을 사용한 부산지역 주요 도로의 대기오염도 조사 (An Investigation into Air Quality of Main Roads in Busan using Mobile Platform Measurement)

  • 도우곤;정우식;유은철;곽진
    • 한국환경과학회지
    • /
    • 제22권9호
    • /
    • pp.1199-1211
    • /
    • 2013
  • Mobile sources produce a significant fraction of total anthropogenic emissions in Korea and have harmful effects on air quality. Mobile emissions are intrinsically difficult to estimate due to complicated road networks and variations of traffic volume with location and time. To measure traffic pollutants with high temporal and spatial resolution under real conditions a mobile laboratory was designed. The mobile laboratory provide concentrations of $SO_2$, CO, NO, $NO_2$ and location coordinate value. This approach allowed for pollutant level measurements on many roads within short periods of time. In this study, on-road concentrations of $SO_2$, CO, NO and $NO_2$ were measured using mobile platform measurement along the 25 main roads in Busan to estimate the average air pollution level in short time difference. The measurements were conducted on favorable meteorological days from 2010 to 2012 and the overall concentrations of $SO_2$, CO, NO and $NO_2$ were 0.006, 0.8, 0.182 and 0.055 ppm respectively. The result showed that the concentration of CO, NO and $NO_2$ on road were twice, 18 times and 2.5 times higher than regional air quality monitoring sites mean in same period.

충남지역 대형사업장의 대기오염물질 확산 특성 파악 (Characterization of Atmospheric Dispersion Pattern from Large Sources in Chungnam, Korea)

  • 최우영;박민하;정창훈;김용표;이지이
    • 한국입자에어로졸학회지
    • /
    • 제17권3호
    • /
    • pp.55-69
    • /
    • 2021
  • Chungnam region accounts for the largest SOX (22.8%) emission with the second-largest NOX (10.8%) emission in Korea due to the integration of many large industrial sources including a steel mill, coal-fired power plants, and petrochemical complex. Air pollutants emitted by large industrial sources can cause harmful problems to humans and the environment. Thus, it is necessary to understand dispersion patterns of air pollutants from large industrial sources in Chungnam to characterize atmospheric contamination in Chungnam and the surrounding area. In this study, seasonal atmospheric dispersion characteristics for SOX, NOX, and PM2.5 from ten major point sources in Chungnam were evaluated using HYSPLIT 4 model, and their contributions to SO2, NO2 concentrations in the regions near the source areas were estimated. The predictions of the HYSPLIT 4 model show a seasonal different dispersion pattern, in which air pollutants were dispersed toward the southeast in winter while, northeast in summer. In summer, due to weaker wind speed, air pollutants concentrations were higher than in winter, and they were dispersed to the metropolitan area. The local emissions of air pollutants in Taean area had a greater influence on the ambient SO2 and NO2 concentrations at Taean, whereas SOX and NOX emissions from large sources located at Seosan showed relatevely little effect on the ambient ambient SO2 and NO2 concentrations at Seosan.