• Title/Summary/Keyword: Hardness measurement

Search Result 548, Processing Time 0.027 seconds

PLASMA-SULFNITRIDING USING HOLLOW CATHODE DISCHARGE

  • Urao, Ryoichi;Hong, Sung-pill
    • Journal of the Korean institute of surface engineering
    • /
    • v.29 no.5
    • /
    • pp.443-448
    • /
    • 1996
  • In order to plasma-sulfnitride by combining ion-nitriding of a steel and sputtering of MoS$_2$, chromium-molybdenum steel was plasma-sulfritrided using hollow cathode discharge with parallel electrodes which are a main of the steel and a subsidiary cathode of $MoS_2$. The treatment was carried out at 823K for 10.8ks under 665Pa in a 30% $N_2$-70% $H_2$ gas atmosphere. Plasma-sulfnitriding layers formed of the steel were characterized with EDX, XRD, micrographic structure observation and hardness measurement. A compound layer of 8-15$\mu\textrm{m}$ and nitrogen diffusion layer of about 400$\mu\textrm{m}$ were formed on the surface of plasma-sulfnitrided steel. The compound layer consisted of FeS containing Mo and iron nitrides. The nitrides of $\varepsilon$-$Fe_2_3N$ and $\gamma$'-$Fe_4N$ formed under the FeS. The thickness of compound layer and surface hardness were different with the gaps between main and subsidiary cathodes even in the same sulfnitriding temperature. The surface hardnesses after plasma-sulfnitriding were distributed from 640 to 830Hv. The surface hardness was higher in the plasma-sulfnitriding than the usual sulfnitriding in molten salt. This may be due to Mo in sulfnitriding layer.

  • PDF

Plasma-Sprayed $Al_{2}O_{3}-SiO_{2}$ Multi-Oxide Films on Stainless Steel Substrate

  • Korobova, N.;Soh, Deawha
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.116-119
    • /
    • 2000
  • The advantage of plasma-sprayed coating is their good resistance against thermal shock due to the porous state of the coated layer with a consequently low Youngs modules. However, the existence of many pores with a bimodal distribution and a laminar structure in the coating reduces coating strength and oxidation protection of the base metals. In order to counteract these problems, there have been many efforts to obtain dense coatings by spraying under low pressure or vacuum and by controlling particle size and morphology of the spraying materials. The aim of the present study is to survey the effects of the HIP treatment between 1100 and 130$0^{\circ}C$ on plasma-sprayed oxide coating of A1$_2$O$_3$, A1$_2$O$_3$-SiO$_2$ on the metal substrate (type C18N10T stainless steel). These effects were characterized by phase identification, Vickers hardness measurement, and tensile test before and after HIPing, These results show that high-pressure treatment has an advantage for improving adhesive strength and Vickers hardness of plasma- sprayed coatings.

  • PDF

A Study on the Mechanical Properties and Corrosion Resistance of GCD40 by Plasma Nitriding (플라즈마 질화처리한 GCD40의 기계적성질 및 내식성에 관한 연구)

  • Kim, M.K.;Jung, B.H.;Kim, S.S.
    • Journal of Power System Engineering
    • /
    • v.6 no.1
    • /
    • pp.74-81
    • /
    • 2002
  • The characteristics of corrosion resistance for the surface of ductile cast iron(GCD40) by plasma nitriding process have been studied in terms of electrochemical polarization behaviors including corrosion potential($E_{corr}$), anodic polarization trends, polarization resistance($R_p$), and also have been studied microstructures, hardness and specific wear of nitrided layer Nitrided layer showed an enhanced hardness values in all the plasma nitriding condition investigated. In the result of wear test, specific wear of nitrided specimens were much decreased than that of non-treated specimens. In the results of XRD, ${\gamma}'phase\;and\;{\varepsilon}$ phase were detected in nitrided surface. And it was found that ${\varepsilon}$ phase was decreased and ${\gamma}'phase$ was increased respectively, as the nitriding time became longer. In the test of corrosion resistance, natural potentials in all the nitrided specimens were towards noble directions than in the case of non-treated specimens. The measurement of electrode potentials revealed that corrosion resistivity of plasma nitrided specimens were higher than in the case of the non-treated specimens.

  • PDF

Characteristics of Surface Hardening by Laser Power Control in Real Time of Spheroidal Graphite Cast Iron (실시간 출력 제어를 통한 구상흑연 주철의 레이저 표면경화 특성)

  • Kim, Jongdo;Song, Mookeun
    • Laser Solutions
    • /
    • v.18 no.2
    • /
    • pp.1-4
    • /
    • 2015
  • This study is related to the surface hardening treatment to spheroidal graphite cast iron for die by using high power diode laser. Laser device used in this experiment is capable of real-time laser power control. This is because the infrared temperature sensor (two color pyrometer) attached to the optical system measures the surface temperature of specimen and adjusts the laser power in real time. The surface treatment was carried out with the change of heat treatment temperature at the beam travel speed 3 mm/sec. Hardened width and depth was measured and hardened zone was analyzed by micro vickers hardness test in order to research the optimum condition of heat treatment. The changes in microstructure of the hardened zone also was examined. As a result of hardness measurement and observations on microstructure of hardened zone, hardness increased over three times as compared with base metal because the martensite was formed on the matrix structure.

A Study on the Effect of Addition of Dietary Fibers on Quality of Julpyun (식이섬유 첨가가 절편의 특성에 미치는 영향에 관한 연구)

  • Lee, Ji-Young;Koo, Sung-Ja
    • Korean journal of food and cookery science
    • /
    • v.10 no.3
    • /
    • pp.267-276
    • /
    • 1994
  • Recent epidemological observations suggested beneficial effects of dietary fiber on man's health. With the increased emphasis placed on the requirement for dietary fiber in the diet, there has been greater interest in successfully incorporating dietary fiber into food products. Hence, in this study, several dietary fibers such as cellulose, pectin, rice bran, barley bran and job's tears bran were incorporated into julpyun to determine their effects on some physical properties and sensory characteristics. Difference of water binding capacity(WBC) was found among dietary fiber sources. The WBC of pectin was highest and that of job's tears bran was lowest. The moisture contents of julpyun were increased as WBC of added dietary fiber sources was higher. In the rheometer measurement for julpyun added with dietary fiber, hardness of julpyuns added with cellulose and pectin was low. But, hardness of julpyun added cellulose was increased rapidly during storage at 4$^{\circ}C$. Springiness and gumminess wereshowed similar aspects to hardness. In the retrogradation speed by Avrami equation, the rate constant of julpyun added barley bran was low ao retrogradation occurred slowly. The results of sensory evaluation, julpyun added no dietary fiber showed good overall preference. Overall preference in sensory evaluation showed positive correlation with the after-swallowing and color.

  • PDF

Assessing Commercial CLEANBOLUS Based on Silicone for Clinical Use

  • Son, Jaeman;Jung, Seongmoon;Park, Jong Min;Choi, Chang Heon;Kim, Jung-in
    • Progress in Medical Physics
    • /
    • v.32 no.4
    • /
    • pp.159-164
    • /
    • 2021
  • Purpose: We investigated the properties of CLEANBOLUS based on silicone with suitable characteristics for clinical use. Methods: We evaluated the characteristics of CLEANBOLUS and compared the results with the commercial product (Super-Flex bolus). Also, we conducted physical evaluations, including shore hardness, element composition, and elongation break. Transparency was investigated through the measured absorbance within the visible region (400-700 nm). Also, dosimetric characteristics were investigated with surface dose and beam quality. Finally, the volume of unwanted air gap was investigated based on computed tomography images for breast, chin, and nose using Super-Flex bolus and CELANBOLUS. Results: CLEANBOLUS showed excellent physical properties for a low shore hardness (000-35) and elongation break (>1,000%). Additionally, it was shown that CLEANBOLUS is more transparent than Super-Flex bolus. Dosimetric results obtained through measurement and calculation have an electron density similar to water in CLEANBOLUS. Finally, CLEANBOLUS showed that the volume of unwanted air gap between the phantom and each bolus is smaller than Super-Flex bolus for breast, chin, and nose. Conclusions: The physical properties of CLEANBOLUS, including excellent adhesive strength and lower shore hardness, reduce unwanted air gaps and ensure accurate dose distribution. Therefore, it would be an alternative to other boluses, thus improving clinical use efficiency.

Research on soil composition measurement sensor configuration and UI implementation (토양 성분 측정 센서 구성 및 UI 구현에 관한 연구)

  • Ye Eun Park;Jin Hyoung Jeong;Jae Hyun Jo;Young Yoon Chang;Sang Sik Lee
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.17 no.1
    • /
    • pp.76-81
    • /
    • 2024
  • Recently, agricultural methods are changing from experience-based agriculture to data-based agriculture. Changes in agricultural production due to the 4th Industrial Revolution are largely occurring in three areas: smart sensing and monitoring, smart analysis and planning, and smart control. In order to realize open-field smart agriculture, information on the physical and chemical properties of soil is essential. Conventional physicochemical measurements are conducted in a laboratory after collecting samples, which consumes a lot of cost, labor, and time, so they are quickly measured in the field. Measurement technology that can do this is urgently needed. In addition, a soil analysis system that can be carried and moved by the measurer and used in Korea's rice fields, fields, and facility houses is needed. To solve this problem, our goal is to develop and commercialize software that can collect soil samples and analyze the information. In this study, basic soil composition measurement was conducted using soil composition measurement sensors consisting of hardness measurement and electrode sensors. Through future research, we plan to develop a system that applies soil sampling using a CCD camera, ultrasonic sensor, and sampler. Therefore, we implemented a sensor and soil analysis UI that can measure and analyze the soil condition in real time, such as hardness measurement display using a load cell and moisture, PH, and EC measurement display using conductivity.

Advanced Metallic Coating for the Improvement of Corrosion and Erosion Resistance of Iron Base Materials Used in Buildings and Special Works

  • Jayaraj, J.;Seok, H.K.;Byun, K.H.;Fleury, E.;Hong, K.T.
    • Corrosion Science and Technology
    • /
    • v.4 no.2
    • /
    • pp.64-68
    • /
    • 2005
  • Various metallic materials are coated on Fe base materials via thermal spraying or welding process to improve both corrosion resistance as well as erosion resistance of the Fe base materials used in buildings and special works. The mechanical properties and corrosion resistance of the coat are estimated by means of hardness measurement and anodic polarization test. In additions, the effect of alloying elements and microstructure of the coatings on the mechanical and chemical properties of the coat is investigated using X- ray diffraction, Optical microscope, Transmission electron microscopy and Auger analysis. The coating deposited by tungsten inert gas (TIG) welding exhibit a good combination of hardness and corrosion properties.

Tribological Performance of Supper-A Dental Material (치과용 재료 Supper-A의 트라이볼로지적 고찰)

  • Choi, Won-Sik;Kim, Won-Ku;Kwon, Soon-Hong;Chung, Sung-Won;Kwon, Soon-Gu;Park, Jong-Min
    • Tribology and Lubricants
    • /
    • v.23 no.6
    • /
    • pp.318-322
    • /
    • 2007
  • The wear characteristics in supre-A dental material have been investigated. The wear tests were performed by using pin-on-disk wear tester at room temperature. Vickers hardness and fracture toughness measurement of dental materials were preformed. Microscopic observations on worn surfaces of specimens were conducted by SEM. The friction coefficient of supper-A material was investigated according to weight and slinging velocity. The hardness of supper-A material was a half of the enamel of natural teeth.

Effect of Cereals on the Physicochemical and Sensory Characteristics of Noti - lV. Study on the Physicochemical and Sensory Characteristics of Glutinous Indian millet Noti - (노티의 재료에 따른 이화학적, 관능적 및 기계적 특성 연구 -제 4 보: 차수수 노티의 이화학적, 관능적 및 기계적 특성 연구-)

  • 임희정;염초애
    • Korean journal of food and cookery science
    • /
    • v.12 no.4
    • /
    • pp.511-521
    • /
    • 1996
  • This study was undertaken to investigate the effect of cereals on the physicochemical and sensory charac teristics of Noti. Noti is one of Korean traditional pan-fried glutinous cereal cakes. In this case, Noti was made from the steamed glutinous Indian millet flour. Acid value was not increased abruptly, TBA value was main tained, and reducing sugar content was increased as compared with the first day that glutinous Indian millet Noti was made during 90 day storage. Through sensory evaluation, color, flavor, moistness, and consistency (the inner part) were unfavorable according to the storage. The texture tended to increase depending upon the storage period. The hardness of glutinous Indian millet Noti by Instron measurement was slowly increased. Cohesiveness and elasticity were increased during storage.

  • PDF