• 제목/요약/키워드: Hardness Distribution

검색결과 502건 처리시간 0.029초

1000MPa급 DP강의 Nd:YAG 레이저 용접부의 기계적 성질과 성형성에 미치는 용접 속도의 영향 (Effect of Welding Speed on Mechanical Properties and Formability in Nd:YAG Laser Welds of 1000MPa Grade DP Steel)

  • 장진영;최우남;정병훈;강정윤
    • Journal of Welding and Joining
    • /
    • 제27권2호
    • /
    • pp.69-75
    • /
    • 2009
  • The effects of welding speed were investigated on penetration characteristics, defects and mechanical properties including formability test in Nd:YAG laser welded 1000MPa grade DP steels. A shielding gas was not used and bead-on-plate welding was performed with various welding speeds at 3.5kW laser power. Defects of surface and inner beads were not observed in all welding speeds. As the welding speed increased, the weld cross-section varied from the trapezoid having wider bottom bead, through X type, finally to V type in partial penetration range of welding speeds. The characteristic of hardness distribution was also investigated. The center of HAZ had maximum hardness, followed by a slight decrease of hardness as approaching to FZ. Significant softening occurred at the HAZ near BM. Regardless of the welding speed, the weld showed approximately the same hardness distribution. In the perpendicular tensile test with respect to the weld direction, all specimens were fractured at the softening zone. In the parallel tensile test to the weld direction, the first crack occurred at weld center and then propagated into the weld. Good formability over 80% was taken for all welding conditions.

Al6061 열간단조시 계면열전달계수에 관한 연구 (A study on interface heat transfer coefficient in hot forging of Al6061 by experiments and FE analysis)

  • 권진욱;이영선;권용남;이정환
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2005년도 춘계학술대회 논문집
    • /
    • pp.219-222
    • /
    • 2005
  • The temperature difference between die and workpiece has frequently caused various surface defects. The non-homogeneous temperature distribution of forged part should be analyzed to prevent the generation of various defects related with the temperature. The surface temperatures were mainly affected by the coefficient of thermal contact conductance. The precise coefficient is necessary to predict accurately the temperature changes of die and workpiece. The experiment is preformed to measure the temperature distribution of die and workpiece in closed die upsetting. And then, the coefficient is classified into function of pressure and confirmed by the comparison between experiments and FE analyses using the other model. The FE analysis to predict the temperature distribution is performed by commercial software $DEFORM-3D^{TM}$. However, it might be impossible to measure directly the temperature distribution of forged part. Therefore, the comparisons between measured temperature and predicted values are performed with the hardness of Al6061-forged part.

  • PDF

인발 봉재의 반경방향 불균일 변형률 평가 (Evaluation of Radial Direction Non-uniform Strain in Drawn Bar)

  • 이성민;이인규;이성윤;정명식;문영훈;이상곤
    • 소성∙가공
    • /
    • 제29권6호
    • /
    • pp.356-361
    • /
    • 2020
  • In general, the drawing process is performed in a multi-pass to meet the required shape and cross section. In the drawn material, the surface strain is relatively higher than the center due to the direct contact with the die. Therefore, a non-uniform strain distribution appears in the surface of the material where the strain is concentrated and the center having a relatively low strain, thus it is difficult to predict the strain in the drawn material. In this study, the non-uniform strain distribution was evaluated using a finite element analysis and the non-uniform strain distribution model based on the upper bound method. In addition, the relationship between the hardness and the strain was established through a simple compression test to evaluate the distribution of the strain in the experimentally multi-pass drawn bar.

토션바재의 마찰용접에 관한 연구(II) -용접 후열처리가 마찰용접 품질에 미치는 영향- (Study on Friction Welding of Torsion Bar Material(II) - Effect of PWHT on Friction Weld Quality-)

  • 오세규;이종두
    • 한국해양공학회지
    • /
    • 제4권2호
    • /
    • pp.94-99
    • /
    • 1990
  • This paper deals with investigating experimentally the effects of PWHT on the weld quality such as strength, toughness, hardness and micro-structure of the welded joints in friction welding of torsion bar material SUP9A bar to bar. The results obtained are summarized as follows; 1) It was certified that the condition of the post-weld heat treatment(PWHT) for the friction welded joints was very satisfactory because both strength and toughness of the joints were improved as almost same as those of the base metal or better by the PWHT. 2) The peak of hardness distribution of the friction welded joints can be eliminated by PWHT, resulting in being almost equalized at the weld interface, the HAZ(heat affected zone) and the base metal. 3) The micro-structure of the base meta., HAZ and weld interface(WI) of friction welded joints welded at the optimum welding condition consists of the same sorbite structure obtained by PWHT and fined sorbite at WI, resulting in increasing toughness as well as strength, and no micro structural defect has been found at the friction welded zone.

  • PDF

토션바재의 마찰용접에 관한 연구(II) -용접 후열처리가 마찰용접 품질에 미치는 영향- (Study on Friction Welding of Torsion Bar Material(II) - Effect of PWHT on Friction Weld Quality-)

  • 오세규;이종두
    • 한국해양공학회지
    • /
    • 제4권2호
    • /
    • pp.244-244
    • /
    • 1990
  • This paper deals with investigating experimentally the effects of PWHT on the weld quality such as strength, toughness, hardness and micro-structure of the welded joints in friction welding of torsion bar material SUP9A bar to bar. The results obtained are summarized as follows; 1) It was certified that the condition of the post-weld heat treatment(PWHT) for the friction welded joints was very satisfactory because both strength and toughness of the joints were improved as almost same as those of the base metal or better by the PWHT. 2) The peak of hardness distribution of the friction welded joints can be eliminated by PWHT, resulting in being almost equalized at the weld interface, the HAZ(heat affected zone) and the base metal. 3) The micro-structure of the base meta., HAZ and weld interface(WI) of friction welded joints welded at the optimum welding condition consists of the same sorbite structure obtained by PWHT and fined sorbite at WI, resulting in increasing toughness as well as strength, and no micro structural defect has been found at the friction welded zone.

AIP-TiN 코팅에서 증착시간이 SKH51과 SKD11 강의 표면특성에 미치는 영향에 관한 비교 연구 (Comparative Study on Effect of the Surface Characteristics of the SKH51 and SKD11 Steels with Deposition Times by AIP-TiN Coating)

  • 김해지;김남경
    • 한국기계가공학회지
    • /
    • 제7권1호
    • /
    • pp.67-74
    • /
    • 2008
  • In this paper, the surface characteristics of the AIP-TiN coated of the SKH51 and SKD11 steels under various deposition times are presented with emphasis on the comparison of the two materials. The micro-particle, the surface roughness, the micro-hardness, the coated layer thickness, the atomic distribution of Ti, N and Fe elements and the adhesion are measured for various deposition times. It has been shown that the micro-particle, the surface roughness, the coated layer thickness and the atomic distribution of Ti, N and Fe elements are similar for the two cases regardless of the test deposition time from 10 to 180 minutes. However, it has been shown that the micro-hardness and the adhesion of the SKH51 steel are higher than the SKD11 steel, indicating that they are much affected by the hardness of the material to be coated.

  • PDF

SM45C강의 연속파 Nd:YAG레이저표면경화와 고주파표면경화특성 비교 (Comparison of Characteristics on Induction and Continuous Nd:YAG Laser Surface hardening of SM45C Steel)

  • 신호준;유영태;안동규;신병헌
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 추계학술대회 논문집
    • /
    • pp.176-183
    • /
    • 2005
  • Laser heat treatment technology is used for improving the feature of fatigue resistance and wear resistance in mobile parts. The purpose of this study is to compare the characteristics of laser heat treatment and high frequency heat treatment, which is commonly used in industrial place. For the preemptive experiment, the distribution, depth and size of hardening and its micro-structural features were compared between surface heat treatment case by defocusing and variables of each process for heat treatment by exclusively manufactured heat treatment optical system. As a result, high frequency heat treatment has wide distribution of hardening depth and width about 3 times larger than laser heat treatment, however, its average hardness showed 621.4Hv which is smaller than the average hardness of laser heat treatment with 691Hv.

  • PDF

3.2t 보론강 판재 직수냉각 핫스탬핑시 냉각수 유량에 따른 미세조직 및 기계적 특성 (Microstructure and Mechanical Properties of Hot-Stamped 3.2t Boron Steels according to Water Flow Rate in Direct Water Quenching Process)

  • 박현태;권의표;임익태
    • 한국재료학회지
    • /
    • 제30권12호
    • /
    • pp.693-700
    • /
    • 2020
  • Direct water quenching technique can be used in hot stamping process to obtain higher cooling rate compared to that of the normal die cooling method. In the direct water quenching process, setting proper water flow rate in consideration of material thickness and the size of the area directly cooled in the component is important to ensure uniform microstructure and mechanical properties. In this study, to derive proper water flow rate conditions that can achieve uniform microstructure and mechanical properties, microstructure and hardness distribution in various water flow rate conditions are measured for 3.2 mm thick boron steel sheet. Hardness distribution is uniform under the flow condition of 1.5 L/min or higher. However, due to the lower cooling rate in that area, the lower flow conditions result in a drastic decrease in hardness in some areas in the hot-stamped part, resulting in low martensite fraction. From these results, it is found that the selection of proper water flow rate is an important factor in hot stamping with direct water quenching process to ensure uniform mechanical properties.

성형실험을 통한 냉간단조 공정의 단축 유한요소 시뮬레이션 (Reduced Finite Element Simulation of Cold Forging Processes Based on the Forming Experiment)

  • 이충호
    • 소성∙가공
    • /
    • 제6권5호
    • /
    • pp.395-399
    • /
    • 1997
  • There exists a certain functional relation between Vickers hardness and flow stress in the strain-hardened material. Using this relation, the Vickers hardness values in the strain-hardened material can be converted into the flow stress values in good approximation. Therefore, the information about the flow stress distribution in the material can be easily acquired through a forming experiment. That makes it possible to simulate the process state for a critical moment of cold forging under the given boundary conditions very quickly without calculating the foregoing history of the actual deformation from the beginning.

  • PDF

PTA법에 의한 스텔라이트 12 합금 육성층의 특성에 미치는 전류의 영향 (The Effect of Current on Characteristics of Stellite 12 Alloy Overlayer by PTA Process)

  • 정병호;김무길;안용식;김민영;이성열
    • 동력기계공학회지
    • /
    • 제5권3호
    • /
    • pp.88-94
    • /
    • 2001
  • Stellite 12 alloy-powders were overlaid on 410 stainless steel valve seat using plasma transferred arc(PTA) process. Variation of the microstructure, hardness, wear and corrosion of overlaid deposit with current change was investigated. The deposit showed hypoeutectic microstructure, which was consisted of primary cobalt dendrite and networked $M_7C_3$ type eutectic carbides. As current increased, the amount of eutectic carbide decreased and its dendritic secondary arm spacing increased. Hardness of the deposit was decreased with increase of current. Stress relief heat treatment at $600^{\circ}C$ for two hours resulted in slight increase of hardness in the deposit and showed uniform hardness distribution in base metal without any hardened layer in HAZ. Specific wear decreased with increase of sliding distance. The deposit of high hardness with a lot of eutectic carbide showed relatively low specific wear. Initial corrosion current density of the deposit in 0.1N sulfuric acid was lower than those of 410 stainless steel, and showed a little variation with PTA current.

  • PDF