• Title/Summary/Keyword: Hanger Rope

Search Result 7, Processing Time 0.027 seconds

An Experimental Study on Isolation System of Aerial Gas Pipeline for Vehicle Vibration (차량진동에 대한 노출가스관의 방진 시스템 개발을 위한 실험적 연구)

  • 박연수;강성후;박선주
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.11 no.5
    • /
    • pp.131-139
    • /
    • 2001
  • In this paper, aerials gas pipeline vibrations due to the passing of vehicles have been measured, and peak values and characteristics of vibration were analyzed. In order to develop isolation system for gas pipeline, six cases with various support condition and hanging method were tested. The hanger used instead of wore rope isolated almost all vibrations transmitted from main beam. In the results of test, we could decrease response of vibration velocity from 49 % to 56 % and response of vertical vibration acceleration from 49 % to 60 %, because hanger instead of wire rope was used and rubber pads instead of wooden shield plates at support positions for Proofing horizontal vibration were used.

  • PDF

Monitoring and control of wind-induced vibrations of hanger ropes of a suspension bridge

  • Hua, Xu G.;Chen, Zheng Q.;Lei, Xu;Wen, Qin;Niu, Hua W.
    • Smart Structures and Systems
    • /
    • v.23 no.6
    • /
    • pp.683-693
    • /
    • 2019
  • In August 2012, during the passage of the typhoon Haikui (1211), large amplitude vibrations were observed on long hangers of the Xihoumen suspension Bridge, which destroyed a few viscoelastic dampers originally installed to connect a pair of hanger ropes transversely. The purpose of this study is to identify the cause of vibration and to develop countermeasures against vibration. Field measurements have been conducted in order to correlate the wind and vibration characteristics of hangers. Furthermore, a replica aeroelastic model of prototype hangers consisting of four parallel ropes was used to study the aeroelastic behavior of hanger ropes and to examine the effect of the rigid spacers on vibration mitigation. It is shown that the downstream hanger rope experiences the most violent elliptical vibration for certain wind direction, and the vibration is mainly attributed to wake interference of parallel hanger ropes. Based on wind tunnel tests and field validation, it is confirmed that four rigid spacers placed vertically at equal intervals are sufficient to suppress the wake-induced vibrations. Since the deployment of spacers on hangers, server hanger vibrations and clash of hanger ropes are never observed.

Aerodynamic Stability Assessment of PWS and CFRC Hanger Ropes for Suspension Bridge by Experiments (현수교 PWS 및 CFRC 행어로프의 내풍안정성 실험 평가)

  • Park, Hyung-Ghee;Kang, Seon-Jin
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.8 no.6
    • /
    • pp.21-30
    • /
    • 2008
  • In this study, to evaluate the aerodynamic stability of suspension bridge hanger ropes, the wind tunnel tests are carried out. It is found that the vortex induced vibration is detected only in single PE-coated PWS cable case. And the wake galloping is occurred in twin cables spaced $3\sim6$ cable diameters of cable center to center when the incidence angle of wind is only zero degree. In case of other incidence angles of wind except zero degree, the wake galloping or the wake flutter are showed in twin cables even outside range of the bounds of $3\sim6$ cable diameters. CFRC cable shows very stable for the twin cables regardless of the distance between two cables, and also for various incidence angles of wind. Thus the characteristic of CFRC rope overwhelms one of PWS cable in aerodynamic stability.

Effect of Support Rotational Stiffness on Tension Estimation of Short Hanger Ropes in Suspension Bridges (현수교 짧은 행어로프의 장력추정시 지점부 회전강성의 영향)

  • Lee, Jungwhee;Ro, Sang-Kon;Lee, Young-Dai;Kang, Byung-Chan
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.23 no.10
    • /
    • pp.869-877
    • /
    • 2013
  • Tension force of hanger ropes has been recognized and utilized as an important parameter for health monitoring of suspension bridges. Conventional vibration method based on string theory has been utilized to estimate tension forces of relatively long hanger ropes without any problem, however it is convinced that the vibration method is not applicable for shorter hanger ropes in which the influence of flexural stiffness is not ignorable. Therefore, as an alternative of vibration method, a number of feasibility studies of system identification(SI) technique considering flexural stiffness of the hanger ropes are recently performed. In this study, the influence of support condition of the finite element model utilized for the SI method is investigated with numerical examples. The numerical examples are prepared with the specification of the Kwang-Ahn bridge hanger ropes, and it is revealed that the estimation result of the tension force can be varied from -21.6 % to +35.3 % of the exact value according to the consideration of the support condition of FE model. Therefore, it is concluded that the rotational stiffness of the support spring should be included to the list of the identification parameters of the FE model to improve the result of tension estimation.

An Analysis of the Long-term Behavior of the Cable System in the Suspension Bridge (현수교 케이블 시스템의 장기거동 분석)

  • Ryu, Duck-Yong;Kim, See-Dong;Jung, Hie-Young
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.13 no.3 s.55
    • /
    • pp.135-144
    • /
    • 2009
  • The cable system of suspension bridges is a very important non-elastic element which caries an external load by a tension force of the cable, such that creates the integrity of a structure. It is not easy to find if cable system have been changed by the maintenance activities such as repairs or reinforcement. Sometimes the maintenance can cause structural deformations and changes of the tension force in cables. In most cases, the cable stayed bridges are managed by health monitering system, however, the main cable of suspension bridges need to develop more accurate and efficient monitoring system. The Namhee Bridge was constructed 35 years ago and it has been continually repaired and reinforced after then. This study describes the behavior of the cable system by analysing many of inspective reports and by using the results of hanger rope test and for the shape of main cables surveys.

The Study on Countermeasures of Electromagnetic Force by Three Phase Short-Circuit Test of Underground Transmission Cable (송전케이블 삼상단락 실증시험을 통한 전자력 대책방안 연구)

  • Kang, Ji-Won;Park, Hung-Sok;Yoon, Jong-Keon;Kim, Yang-Sang;Hong, Dong-Suk;Chang, Woo-Seog
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.12
    • /
    • pp.2342-2348
    • /
    • 2009
  • Even though underground transmission cable is an essential transmission method to supply stable power for downtown and population center, the interaction of electromagnetic force by fault current is very large comparing to overhead transmission line due to restricted installation space such as tunnel, and close consideration is required for it. This paper presents countermeasures to reduce and release the effect of electromagnetic force with rope binding and installation of spacer and describes its efficacy through three phase short-circuit test, which will be utilized as basic materials for improvement and development of cleat, hanger, etc. to reduce and release effect of electromagnetic force in the future.

The Study on Countermeasures of Electromagnetic Force by Three Phase Short-Circuit Test of Cable (케이블 삼상단락 실증시험을 통한 전자력 대책방안 검토)

  • Hong, Dong-Suk;Kim, Hae-Jun;Park, Sung-Min;Chang, Woo-Suk;Park, Heong-Suk;Jang, Tae-In;Kang, Ji-Won
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.363_364
    • /
    • 2009
  • Even though underground transmission cable is an essential transmission method to supply stable power for downtown and population center, interaction of electromagnetic force from fault current is very large comparing to overhead transmission line due to restricted installation space such as tunnel, etc. and close consideration is required for it. This paper presents countermeasures to reduce and release the effect of electromagnetic force with rope binding and installation of spacer and describes its efficacy through three phase short-circuit test, which will be utilized as basic materials for improvement and development of cleat, hanger, etc. to reduce and release effect of electromagnetic force in the future.

  • PDF