• 제목/요약/키워드: Hand-arm vibration syndrome

검색결과 12건 처리시간 0.032초

The Health Effect of Hand Arm Transmitted Vibration

  • Koo, Jung-Wan
    • 대한인간공학회지
    • /
    • 제32권4호
    • /
    • pp.303-308
    • /
    • 2013
  • Objective: The aim of this study is to understand health effect of hand-arm transmitted vibration. Background: Electronic vibration tools have been used in many industries. These tools evoke hand-arm transmitted vibration that cause hand-arm vibration syndrome. Method: Various papers on the hand-arm transmitted vibration and its health effects have been reviewed to know what health effect caused. Results: Hand-arm transmitted vibration causes circulatory, neural, musculoskeletal and other disturbance. Conclusion: The previous studies focused on the epidemiology and physiology for hand-arm transmitted vibration. So, now we should focus on a prevention and guideline of hand-arm transmitted vibration. Application: These results can be used to know health effect of hand-arm transmitted vibration.

Segmental Sensory Nerve Conduction Study in Vibration Exposed Subjects

  • Kim Mi-Jung;Yoon Cheol-In;Choi Hyun-Ju
    • 대한의생명과학회지
    • /
    • 제11권2호
    • /
    • pp.193-199
    • /
    • 2005
  • The present study was performed to assess peripheral neural involvement by exposure to hand-arm vibration. Segmental sensory nerve conduction in the median and ulnar nerves were measured in shipyard workers exposed to vibration. The subjects were 47 male adults exposed to hand-arm vibration and 7 healthy male controls. The subjects underwent an extensive bilateral neurophysiological examination. Sensory compound nerve action potential (SNAP) of the median and ulnar nerves in palm-finger and wrist-palm segments were measured by antidromic method. And SNAP of the median and ulnar nerves in wrist-proximal finger and wrist-distal finger segments were measured by orthodromic method. Result of sensory nerve conduction study was abnormal in 31 patients $(66\%)$ and normal in 16 patients $(34\%)$ of subjects. The pathological pattern in the hand-arm vibration exposed group was 13 patients $(28\%)$ of carpal tunnel syndrome, 18 patients $(38\%)$ of distal sensory neuropathy, 7 patients $(15\%)$ of multifocal and 1 patient $(2\%)$ of Guyon syndrome. The present study indicates that vibration-induced nerve impairments exist both in the finger-palm and palm-wrist segment of median and ulnar sensory nerves. The results suggest that segmental sensory nerve conduction study would be useful as objective indication of peripheral nerve impairment induced by the hand-arm vibration.

  • PDF

스웨징 작업에서의 국소진동 노출평가 (Evaluation of Hand-Arm Vibration in Swaging Process)

  • 박인선;박원형;박상규;김규상
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 추계학술대회논문집 I
    • /
    • pp.433-438
    • /
    • 2001
  • This study is performed to evaluate hand-arm vibration syndrome(HA VS) of the workers in swaging process. Vibration measurement and assessment of human exposure are based on the international standard(ISO 5349). Triaxial acceleration of each operation and exposure time are measured to predict the periods before finger blanching, As results, it is found that acceleration is concerned with the diameter of pipes in swaging process, and also found that combined work is more harmful than a single operation.

  • PDF

Experiences of the Specified Symptoms from the Selected Work-Related Musculoskeletal Syndrome and Posture and Action of the Dental Hygienists When Work-Related Musculoskeletal Diseases of Dental Hygienists Patient Care Procedure

  • Lee, Ka Yeon;Chun, Jong Ae
    • International Journal of Clinical Preventive Dentistry
    • /
    • 제14권4호
    • /
    • pp.235-240
    • /
    • 2018
  • Objective: The purpose of this study is to examine about dental hygienists' myofascial pain syndrome, lower back pain, carpal tunnel syndrome (CTS), medial and lateral epicondylitis, hand-arm vibration syndrom and work-related musculoskeletal syndrome (WMSD) experience and hygienists' posture, motion. Methods: The self-administered questionnaire was surveyed from June 1 to September 30 of 2018 targeting 280 dental hygienists in Gyeongnam province and 266 dental hygienists' answers were analyzed. Results: The average daily working hours of a dental hygienist was more than eight hours 59.0%, with an average of 33 patients per day. The average number of patients who receive treatment for more than 30 minutes is 15. The angle of motion of the subjective evaluation was above 60%. Medical position and form of movement were more than 50% above the standard level. Symptoms of posture and motion that cause WMSD were hand-arm vibration syndrome 68.1%, myofascial pain syndrome 58.6%, lower back pain 51.1%, CTS 50.4% in order. Experience WMSD related symptoms which dental hygienists experience were myofascial pain syndrome 92.9%, CTS 57.9%, lower back pain 56.4%, medial and lateral epicondylitis 37.2%, hand-arm vibration syndrome 24.4%. Conclusion: The above results showed the posture and motion of dental hygienists and were found that the experience rate which dental hygienists experience WMSD of myofascial pain syndrome, Lower back pain, and CTS was significantly more than 56%.

수지진동증후군 증상 호소율 조사 (An Investigation of the Symptom Prevalence of Hand-Arm Vibration syndrome among the Workers Using Powered Hand Tools)

  • 박희석;임상혁
    • 대한인간공학회지
    • /
    • 제19권3호
    • /
    • pp.93-107
    • /
    • 2000
  • The excessive exposure to powered hand tools can cause damage to nerves, impair blood circulation, and musculoskeletal damage. The symptoms associated with hand-arm vibration syndrome (HAVS) include numbness, tingling, pain and subsequent reduced dexterity of the hands. This study was performed to report the prevalence of the HAVS and evaluate its related factors among the workers using powered hand tools. Total 282 workers in 11 plants of Kyungki and Inchon areas were examined. A standard symptom questionnaire was developed and administered to collect information on personal characteristics, work history, operating conditions, tool characteristics, and subjective symptoms of HAVS. Mean values (standard deviations) of the age, the duration of powered hand tools used, and the daily hours using powered hand tools were 38.3(8.9) years, 79.3(62.2) months and 6.0(2.6) hours, respectively. 132 workers(46.8%) showed vibration-induced white finger symptoms according to the Taylor-Pelmear classification, and 30 workers(10.6%) were interfered with the work. The results of a multiple logistic regression analysis controlling for age and daily working hours showed that smoking, work duration, weight of tools, and continuous work over 2 hours were significantly associated with the symptom of HAVS.

  • PDF

선박건조업에서 사용되는 그라인더의 진동평가와 수지진동증후군 예측 모델 개발 (Assessment of Vibration Produced by the Grinder Used in the Shipbuilding Industry and Development of Prospective Prevalence Model of Hand-arm Vibration Syndrome)

  • 임상혁;이윤근;박희석
    • 한국산업보건학회지
    • /
    • 제16권4호
    • /
    • pp.398-412
    • /
    • 2006
  • The purpose of this study is to investigate the relationship between the acceleration of vibration by the powered hand tools used in the shipbuilding industry, and to develop the prospective prevalence model for the hand-arm vibration syndrome among the shipbuilding workers.The acceleration levels and frequencies of six types of grinder were measured using the ISO5349 method along with the time of exposure to the vibration from the powered hand tools. Medical examination for 114 workers were performed using the cold provocation test. Comparisons were made between the estimated prevalence of hand-arm vibration syndrome from ISO5349 and the observed values from the medical examinations. By multiple regression, we developed the prospective prevalence model of hand-arm vibration syndrome produced by the hand tools used in the shipbuilding industry. 4 hour-energy-equivalent frequency-weighted accelerations were $6.23m/s^2$ in the grinding job done after welding, and $13.39m/s^2$ in the grinding job done before painting. The mean exposure time while holding powered hand tools was 4.64 hours. Prevalence rates of Raynaud's Phenomenon were 12.04% in the grinding after soldering, and 42.9% in the grinding before painting measured using the ISO5349 method. After exposure to vibration for 10.79 years, about a half of the workers in the grinding after welding could developed Raynaud's Phenomenon. For the workers in the grinding before painting, the latency was 5.02 years. The ISO equation for dose response relationship was not significantly correlated with observed recovery rates of finger skin temperatures, blood flows and amplitudes of nerve conduction velocities. A multiple regression model for dose-response relationship was proposed from the results. Recovery rate of the skin temperatures = -0.668+ 0.337 ${\times}$ 4 hour energy equivalent frequency-weighted accelerations + 0.767 ${\times}$ duration of vibration exposure(years) The validity was proved by multiple regression analysis after correlation transformation and regression results based on model-building data and validation data.

Hand arm vibration measurement using micro-accelerometer in different brick structures

  • Gomathi, K.;Senthilkumar, A.;Shankar, S.;Thangavel, S.;Priya, R. Mohana
    • Smart Structures and Systems
    • /
    • 제13권6호
    • /
    • pp.959-974
    • /
    • 2014
  • Hand-Arm Vibration Syndrome (HAVS) is a group of diseases caused by exposure of the hands to vibration while operating the hand held power tools such as road breaker, drilling machine, demolition hammer in construction works. In this paper, area-changed capacitive micro-accelerometer is designed to measure the vibration exposure on worker's hand when operating a drilling machine on various blocks such as clay block, paver block and solid cement block. The design process includes mathematical modelling of micro-accelerometer and simulations are done using INTELLISUITE 8.6. Experimental results are taken for various blocks surfaces using conventional and micro-accelerometer. Comparisons show that usage of area-changed micro-accelerometer for Hand-arm vibration monitoring provides better sensitivity, which in turn reduces the risk of HAVS in workers.

그라인딩 작업시 손목자세별 국소진동 전달특성 분석 (An Analysis of Transmitted-Vibration Characteristics by Different Wrist Posture during Grinding Tasks)

  • 황성환;이동춘
    • 대한인간공학회지
    • /
    • 제26권1호
    • /
    • pp.29-37
    • /
    • 2007
  • This study was performed to evaluate the characteristics of transmitted vibration to hand-arm system under different work posture while operating a light-weighted powered hand grinder. For the experiment, 8 different types of wrist posture (natural, unlar-flexion, radual-flexion, flexion, extension, complex posture, and etc.) and 3 types of feed force (20[N], 50[N], 70[N]) were considered. 10 male subjects were employed to polish metal plate with a hand grinder. All of them were normal and healthy with no history and symptom of the work related musculoskeletal disorders in the dominant hand. Vibration acceleration data were recorded with sampling rate, 2048[Hz]. In addition, unweighted overall R.M.S. acceleration at the tool and wrist, and transmissibility between them were used to evaluate factors from the recorded tri-axial vibration acceleration. The results indicate that transmissibility of natural wrist posture was significantly higher than others. In addition, as the feed force becomes larger, the vibration was transmitted in large quantities to hand-arm system through radius.

국소진동 보호구의 적합성 평가와 진동공구에 적합한 가진 스펙트럼에 관한 연구 (A Study on the Compatibility Evaluation of Hand-arm Adequate Vibration and an Oscillating Spectrum for Vibrating Tools)

  • 윤희경;김태구;윤유성
    • 한국안전학회지
    • /
    • 제24권1호
    • /
    • pp.60-68
    • /
    • 2009
  • The aim of this paper is to evaluate the compatibility of anti-vibration gloves, to predict the attenuation of vibration with different types of anti-vibration gloves, to estimate the spectra of the ISO 10819 standard, and to present an oscillating spectrum adequate for vibrating tools. This paper use two ISO standards for the measurement and evaluation of hand-arm vibration. Some anti-vibration gloves can attenuate vibration, but all the anti-vibration gloves in this study do not satisfy the ISO 10819 requirements. In case of equal vibration types, the outside materials are effective in order of leather, fabrics and rubber-coating. Anti-vibration gloves manufactured in the United State satisfy ISO 10819 criteria using United State subjects, but do not satisfy ISO 10819 using Japanese subjects. M-spectrum acceleration exists below 10Hz and H-spectrum exists above 500Hz. Generally vibrating tools have the peak of Z-axis, but generation of vibration differ from each vibrating tools.