• 제목/요약/키워드: Hand grip force

검색결과 52건 처리시간 0.03초

수지진동에서의 진동강도, 손잡이온도, 소음 및 미는 힘의 복합효과에 따른 악력 및 지단피부온의 변화 (Combined Effect of Vibration Intensity, Grip Temperature, Noise and Pushing Power on Grip Forces and Skin Temperatures of Fingers)

  • 고경심
    • Journal of Preventive Medicine and Public Health
    • /
    • 제27권4호
    • /
    • pp.763-776
    • /
    • 1994
  • Recent studies reveal that grip forces during the hand-arm vibration are most significant for the genesis of vibration-induced white linger syndrome. Therefore, exerted grip forces and skin temperatures of fingers were regarded as dependent variables in experiments and the effects of grip temperature, noise, pushing force, vibration and the combined effect of vibration and pushing force were studied. The objectives of the present study were, first, to varify and compare the changes of grip force affected by grip temperature, noise, pushing force, vibration and the combined effect of vibration and pushing force and, second, to observe the reaction of finger skin temperature affected by above factors. Forty-six healthy male students ($25.07{\pm}2.85$) participated in five systematically permuted trials, which endured 4 minutes each other. Experiments were executed in a special chamber with an air temperature of 21C. In each experiments, the subjects were exposed to five experiment types: (1) grip force of 25N only, (2) pushing force of 50N, (3) acceleration of vibration $7.1m/sec^2(z-direction)$, (4) pink noise of 95 dB (A) and (5) combination of pushing force 50N and acceleration of vibration $7.1m/sec^2$. A repeated-measures analysis of variance (ANOVA) was performed on the grip force to test whether it was affected by noise, pushing force, vibration and pushing force. The present results show that vibration was significantly related to the increase of grip force, but the other factors, such as pushing force, noise and grip temperature had no signigicant influence on the increase of grip force, and that the reaction of finger skin temperature were significantly affected by the skin temperature at start of experiment and grip temperature, not grip force and other experimental conditions. Therefore, we suggest that the management for decreasing the grip force is meaningful to prevent the occurrence of Hand-arm vibration syndrome (HAVS).

  • PDF

Kinematic characteristics of grip force in patients with cervical spondylosis

  • Lee, Bumsuk;Noguchi, Naoto;Kakiage, Daiki;Yamazaki, Tsuneo
    • Physical Therapy Rehabilitation Science
    • /
    • 제4권2호
    • /
    • pp.61-65
    • /
    • 2015
  • Objective: The aim of this study was to objectively evaluate sensory disturbance in cervical spondylosis using grip force and investigate the relationship between the grip force and upper extremity function. Design: Cross-sectional study. Methods: Eleven cervical spondylosis patients with paresthesia conducted grip and lift tasks using a precision grip with the tips of the thumb and index finger on either side. The sum of the grip force used during the first four seconds was calculated and defined as the total grip force. The cutaneous pressure threshold of the fingers, the pinch power, the grip power and three subtests of the Simple Test for Evaluating Hand Function (STEF) were also assessed. Correlations between the total grip force and cutaneous pressure threshold, pinch power, grip power, and STEF subtest times were evaluated. Results: We found that the total grip force correlated with the cutaneous pressure threshold (p<0.05). Moreover, the total grip force of the dominant thumb correlated with the results of the three STEF subtests (p<0.05). There were no significant correlations between the total grip force and pinch/grip powers. Conclusions: We found that the total grip force correlated with cutaneous pressure threshold and upper extremity function. The results suggest that the total grip force could serve as an objective index for evaluating paresthesia in cervical spondylosis patients, and that the impaired ability of the upper extremity function is related to grip force coordination.

수전달 진동평가량의 랜덤오차 저감을 위한 공구 핸들에서의 진동과 작용력의 동시 측정 (Simultaneous Measurement of Vibration and Applied Forces at a Power Tool Handle for the Reduction of Random Error When valuating Hand-transmitted Vibration)

  • 최석현;장한기;박태원
    • 한국소음진동공학회논문집
    • /
    • 제15권4호
    • /
    • pp.404-411
    • /
    • 2005
  • To increase accurateness and reliability of the evaluation of power tool vibration transmitted to an operator, it is necessary to measure the grip and feed forces during the measurement of hand-transmitted vibration. In the study a system was invented to measure the vibration and the grip and/or feed force, which consists of a measurement handle and a PC with a data acquisition system and the corresponding software. Strain gauges and an accelerometer were mounted on the handle surface for the simultaneous measurement of the forces and the vibration. The program in the system makes it possible to monitor the grip and feed force during the tool operation so that the operator keeps the applying forces within the pre-determined range. Investigating the vibration total values, frequency-weighted root-mean-square accelerations at the handle, obtained in repetition for each power tool with control of the grip and feed force showed more consistency than those measured without force control. By using the system the experimenter can reduce random error of the measured vibration.

수전달 진동 평가를 위한 공구 핸들에서의 진동과 작용력의 동시 측정 (The Simultaneous Measurement of Vibration and Applied forces at a Power tool handle for the Evaluation of Hand-transmitted Vibration)

  • 최석현;장한기;박태원
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 추계학술대회논문집
    • /
    • pp.689-694
    • /
    • 2004
  • To increase accurateness and reliability of the evaluation of power tool vibration transmitted to an operator, it is necessary to measure grip and feed forces during the measurement of hand-transmitted vibration. In the study a system was invented to measure the vibration and the grip and/or feed force, which consists of a measurement handle and a PC with data acquisition system and the software. Strain gauges and an accelerometer were mounted on the handle for the simultaneous measurement of the forces and the vibration. The program in the system makes it possible to monitor the grip and feed force during the tool operation so that the operator keeps the applying forces within the pre-determined range. Investigating the vibration total values, frequency-weighted root mean square accelerations at the handle, obtained at various conditions with control of the grip and feed force showed more consistency than those measured without force control. By using the system the experimenter can reduce uncertainty of the measured vibration.

  • PDF

Evaluation of the Contributions of Individual Finger Forces in Various Submaximal Grip Force Exertion Levels

  • Kong, Yong-Ku;Lee, Inseok;Lee, Juhee;Lee, Kyungsuk;Choi, Kyeong-Hee
    • 대한인간공학회지
    • /
    • 제35권5호
    • /
    • pp.361-370
    • /
    • 2016
  • Objective:The aim of this study is to evaluate contributions of individual finger forces associated with various levels of submaximal voluntary contraction tasks. Background: Although many researches for individual finger force have been conducted, most of the studies mainly focus on the maximal voluntary contraction. However, Information concerning individual finger forces during submaximal voluntary contraction is also very important for developing biomechanical models and for designing hand tools, work equipment, hand prostheses and robotic hands. Due to these reasons, studies on the contribution of individual finger force in submaximal grip force exertions should be fully considered. Method: A total of 60 healthy adults without any musculoskeletal disorders in the upper arms participated in this study. The young group (mean: 23.7 yrs) consisted of 30 healthy adults (15 males and 15 females), and the elderly group (mean: 75.2 yrs) was also composed of 30 participants (15 males and 15 females). A multi-Finger Force Measurement (MFFM) System developed by Kim and Kong (2008) was applied in order to measure total grip strength and individual finger forces. The participants were asked to exert a grip force attempting to minimize the difference between the target force and their exerted force for eight different target forces (5, 15, 25, 35, 45, 55, 65, and 75% MVCs). These target forces based on the maximum voluntary contraction, which were obtained from each participant, were randomly assigned in this study. Results: The contributions of middle and ring fingers to the total grip force represented an increasing trend as the target force level increased. On the other hand, the contributions of index and little fingers showed a decreasing trend as the target force level increased. In particular, Index finger exerted the largest contribution to the total grip force, followed by middle, ring and little fingers in the case of the smallest target force level (5% MVC), whereas middle finger showed the largest contribution, followed by ring, index and little fingers at the largest target force levels (65 and 75% MVCs). Conclusion: Each individual finger showed a different contribution pattern to the grip force exertion. As the target force level increase from 5 to 75% MVC, the contributions of middle and ring fingers showed an increasing trend, whereas the contributions of index and little fingers represented a decreasing trend in this study. Application: The results of this study can be useful information when designing robotic hands, hand tools and work equipment. Such information would be also useful when abnormal hand functions are evaluated.

수공구 손잡이 형태에 따른 청.노년층의 악력과 손가락 힘 및 편안함 분석 (Grip Force, Finger Force, and Comfort analyses of Young and Old People by Hand Tool Handle Shapes)

  • 공용구;손성태;김대민;정명철
    • 대한인간공학회지
    • /
    • 제28권2호
    • /
    • pp.27-34
    • /
    • 2009
  • The purpose of this study was to evaluate aging (young and old), gender (male and female), and handle shape effects on grip force, finger force, and subjective comfort. Four handle shapes of A, D, I, and V were implemented by a multi-finger force measurement (MFFM) system which was developed to measure every finger force with different grip spans. Forty young (20 males and 20 females) and forty old (20 males and 20 females) subjects participated in twelve gripping tasks and rated their comfort for all handles using a 5-point scale. Grip forces were calculating by summation of all four forces of the index, middle, ring and little fingers. Results showed that young males (283.2N) had larger gripping force than old males (235.6N), while young females (151.4N) had lower force than old females (153.6N). Young subjects exerted the largest gripping force with D-shape due to large contribution of the index and middle fingers and the smallest with A-shape; however, old subjects exerted the largest with I-shape and the smallest with V-shape due to small contribution of the ring and little fingers. As expected, the middle finger had the largest finger force and the little finger had the smallest. The fraction of contribution of index and ring fingers to grip force differed among age groups. Interestingly, young subjects provided larger index finger force than ring finger force, whereas old subjects showed that larger ring finger forces than index finger force in the griping tasks. In the relationship between performance and subjective comfort, I-shape exerting the largest grip force had less comfort than D-shape producing the second largest grip force. The findings of this study can provide guidelines on designing hand tool handle to obtain better performance as well as users' comfort.

데이터 글로브와 진동모터를 이용한 촉각전달 및 제시 방법 (Tactile Transfer and Display Method using Data Glove and Vibration Motors Module)

  • 강형구;최영진
    • 제어로봇시스템학회논문지
    • /
    • 제19권12호
    • /
    • pp.1138-1144
    • /
    • 2013
  • This paper proposes a tactile transfer and display method between a data glove and vibration motors module. The data glove is developed to capture the hand postures and to measure the grip forces. The measured data are simplified with the proposed 5-bit transfer and display algorithm, and the vibration motors module is developed to display the measured hand posture and grip force to the operator. The proposed 5-bit algorithm contains both an 8-step hand posture and 4-step grip force level information for tactile transfer to the vibration motors module. Also, the effectiveness of the proposed method is shown through several experiments.

근전의수의 제어시스템에 관한 연구 (A Study on the Control System of Myoelectric Hand Prosthesis)

  • 최기원;추준욱;최규하
    • 전기학회논문지
    • /
    • 제56권1호
    • /
    • pp.214-221
    • /
    • 2007
  • This paper presents a myoelectric hand prosthesis(MHP) with two degree of freedom(2-DOF), which consists of a mechanical hand, a surface myoelectric sensor(SMES) for measuring myoelectric signal, a control system and a charging battery. The actuation for the 2-DOF hand functions such as grasping and wrist rotation was performed by two DC-motors, and controlled by myoelectric signal measured from the residual forearm muscle. The grip force of the MHP was automatically changed by a mechanical automatic speed reducer mounted on the hand. The skin interface of SMES was composed of the electrodes using the SUS440 metal in order to endure a wet condition due to the sweat. The sensor was embedded with a amplifier and a filter circuit for rejecting the offset voltage caused by power line noises. The control system was composed of the grip force sensor, the slip sensor, and the two controllers. The two controllers were made of a RISC-type microprocessor, and its software was executed on a real-time kernel. The control system used Force Sensing Resistors, FSR, as slip pick-ups at the fingertip of a thumb and the grip force information was obtained from a strain-gauge on the lever of the MHP. The experimental results were showed that the proposed control system is feasible for the MHP.

The Effect of Paraffin Treatment with Exercise on Muscle Strength and Fatigue of the Hand According to the Use of Smartphone

  • Kim, Su-Hyon
    • The Journal of Korean Physical Therapy
    • /
    • 제32권4호
    • /
    • pp.198-202
    • /
    • 2020
  • Purpose: This study examined the effects of a paraffin treatment with exercise on the muscle strength and fatigue of the hand according to the use of smartphones. Methods: The measurement subjects were 30 healthy males in their 20s who were divided randomly into the control and paraffin treatment groups. A typing exercise using a smartphone was performed. The pinch grip force was measured to evaluate the muscle strength of the thumb, and muscle fatigue analysis using electromyography was performed to analyze muscle fatigue. Results: The functional changes to the arm and the fatigue of the hand through the use of a smartphone were examined to determine the effects of the paraffin treatment. The dominant hand-pinch grip force test did not show a significant difference, but the non-dominant hand-pinch grip force test showed a significant difference between the groups (p=0.030). In the dominant hand fatigue test, there was a significant difference between the groups (p=0.037). In the non-dominant hand, there was a significant difference between time (p=0.012) and the groups (p<0.001). Conclusion: The effects of paraffin intervention on the hand muscle strength and fatigue due to repeated use of the smartphone were confirmed. These results can be used as a basis for clinical use and can be a guide for the correct use of smartphones, which are essential in modern life.