• Title/Summary/Keyword: Hand exposure

Search Result 498, Processing Time 0.023 seconds

Temperature Field Measurements of Hele-Shaw Convection Cell Using a Holographic Interferometry (홀로그래픽 간섭계를 이용한 Hele-Shaw Convection Cell 내부 온도장 측정)

  • Kim, Seok;Lee, Sang-Joon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.11
    • /
    • pp.1624-1631
    • /
    • 2001
  • Variations of temperature field in a Hele-Shaw convection cell (HSC) were measured using a holographic interferometry with varying Rayleigh number. Experimental results show a steady flow pattern at low Rayleigh numbers and a time-dependent periodic flow at high Rayleigh numbers. Especially, the period of oscillation at Ra = 6.35 $\times$ 10$^{6}$ was 62 seconds. Two different measurement methods of holographic interferometry, double-exposure method and real-time method, were employed to measure the temperature field variations of HSC convective flow. In the double-exposure method, unwanted waves can be eliminated and reconstruction images are clear, but transient flow structure cannot be observed clearly. On the other hand, transient flow can be observed and reconstructed well using the real-time method. However, the fringe patterns reconstructed by the real-time method contain more noise, compared with the double-exposure method. The two holographic interferometer techniques employed complementary in this study were proved to be useful fur analyzing the temperature field variations of unsteady thermal fluid flows.

Influence of DBD Plasma Exposure on Normal and Cancer Cells Activity

  • Panngom, Kamonporn;Baik, Ku-Youn;Ryu, Young-Huo;Choi, Eun-Ha
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.172-172
    • /
    • 2012
  • Non-thermal plasma has attracted medical researchers, since they showed higher apoptosis rate in cancer cells than normal cells. However, it is hard to conclude general cancer cell specific effect because comparison between normal and cancer cell activities after plasma treatment have not been reported yet. This research proposes a comparison of Dielectric Barrier Discharge (DBD) plasma effect on three normal cells lines and three cancer cells lines. We measured cell number, mitochondria activity (MTS assay) and amount of hydrogen peroxide (H2O2) for three days. The results show that the number of cancer cells decreased more than normal cells following of exposure time. On the other hand, mitochondria activities and amounts of H2O2 increased following of exposure time. In addition, we found that DBD plasma exposure on cell suspension in media and media only illustrated no difference in mitochondria activity, H2O2 quantity, and cell number. Thus, we can confirm higher apoptosis rate in cancer cells which is related to the reactive oxygen species (ROS) generated by DBD plasma. The related molecular mechanisms were investigated further.

  • PDF

Changes of Thyroid Hormone Levels in Plasma of Rats during Cold Exposure (저온환경 적응에 있어서의 갑상선 Hormone의 변동)

  • Lee, H.W.;Kim, W.J.;Hong, S.S.;Kim, H.S.;Hong, S.U.
    • The Korean Journal of Pharmacology
    • /
    • v.17 no.2
    • /
    • pp.37-45
    • /
    • 1981
  • The importance of thyroid hormones for the survival of rats in the cold is along-established fact. Hypothyroid animals are unable to survive in a cold environment. It was also reported that acute exposure of rats, guinea pigs and rabbits to cold produced an increased secretion of TSH and thereby thyroid hormone secretion within 10 to 30 min, but this increase of thyroid activity disappeared quite rapidly during warming. However, in human study no significant difference was found in the concentration of $T_4$, TSH and cortisol between summer and winter. But plasma $T_3$ concentration was increased significantly in winter in 56 adult men. On the other hand, it has been also known that catecholamines are important in the maintenance of body temperature of rat exposured to cold. Abundant evidences suggest that the sympathetic nervous system is involved in the activation of nonshivering thermogenesis and that thyroid hormone metabolism and secretion are influenced by catecholamines and consequently by the activity of the sympatheticadrenal system. Many of the metabolic effects of catecholamines are associated with an increase in the level of cAMP mediated through activation of adenylate cyclase which converts ATP to cAMP. Other studies have shown that thyroid hormones affect the amount of adenylate cyclase present in the adipose tissue. On the other hand. it was also reported that a particulate cAMP phosphodiesterase activity in fat cells was modulated by the action of thyroid hormones. The objective of the present study was to determine the interaction between thyroid activity and cyclic nucleotides during acute exposure to cold. Albino rats weighing around 200 g were used as the experimental animal. The room temperature group was kept at $25^{\circ}C$ and the cold-exposured group was kept at $4^{\circ}C$ for 1 week or 2 weeks. Each group was subdivided into three subgroups; control, KI, and MTU group. At the end of experiment the animals were etherized and blood was taken from abdominal aorta for $T_4,\;T_3$ and cyclic nucleotides. The determinations of $T_3,\;T_4$ and cyclic nucleotides were carried out with a radioimmunoassay(RIA) method. The results were summerized as followings. 1) A significant increase of thyroid weight was observed in rats exposured to cold for 2 weeks. Furthermore, in rats administered MTU while to exposure to cold the thyroid weight was also increased significantly. 2) After 2 weeks $T_3$ concentration in the plasma of cold-exposured rats was significantly increased in KI group and MTU group as well as in control group. On the contrary, after 2 weeks of cold exposure $T_4$ level was decreased in control group. 3) In the case of cyclic nucleotides, plasma cAMP was increased in the control group after 1 or 2 weeks of cold exposure. However, cAMP level in plasma was rather significantly decreased in KI group and MTU group as well as in control group.

  • PDF

Association of Bone Lead with Neurobehavioral Test Scores in Lead Workers (연작업자들에서 골중 연량이 신경행동학적 검사성적에 미치는 영향)

  • Lee, Sung-Soo;Kim, Nam-Soo;Kim, Hwa-Sung;Ahn, Kyu-Dong;Lee, Byung-Kook
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.15 no.2
    • /
    • pp.144-152
    • /
    • 2005
  • To evaluate the effect of lead biomarkers including bone lead on neurobehavioral test in lead workers, 652 lead workers without any occupational exposure to organic solvent, mercury and arsenic were agreed to participate this study. For the control subjects 102 non-occupationally lead exposed blue collar workers in general manufacturing industries were also joined this study. All study subjects joined this study with written informed consent. The study variables of lead exposure were blood and patella lead. For the general characteristics of study subjects, standardized questionnaire regarding age, sex, past disease history, job duration, body mass index (BMI), drinking and smoking habit were provided. For the past history of neurotoxicity related diseases, all study subjects were interviewed by qualified occupational health physician. The results obtained were as follows: 1. Compared with controls without occupational lead exposure, lead exposed subjects had worse performance on all tests(p<0.05). 2. After adjustment for covariates (age, sex, job duration, education level, BMI, smoking and drinking status), the signs of the regression coefficients for blood lead were negative for 13 of the 14 tests. Blood lead was a significant predictor of poorer scores on 8 tests (simple reaction time(ms & root MSD), Trail-Making Test B, Digit Symbol Substitution, Purdue Pegboard assembly, Digit Span Test, Benton Visual Retention, and Purdue pegboard both hand). 3. After adjustment for covariates (age, sex, job duration, education level, BMI, smoking and drinking status), the signs of the regression coefficients for patella lead were negative for 12 of the 14 tests. Patella lead was a significant predictor of poorer scores on 8 tests (simple reaction time(ms). Purdue Pegboard assembly, Digit Span Test, Benton Visual Retention. Pursuit Aiming rest (no. of correct & no. of incorrect), Purdue pegboard non-dominant hand and both hand). With above results, blood lead and patella lead were associated with poorer performance of neurobehavioral tests. In addition, patella lead was confirmed to be better predictor of manual dexterity test in neurobehavioral test battery in lead workers

A Study on the commercial strategies through armature analysis in shopping center - Reference with shopping centers the Jerde Partnership planned - (쇼핑센터에서 Armature 분석을 통한 상업적 전략에 관한 연구 - 저드파트너십의 쇼핑센터를 중심으로 -)

  • Kim, Hyeong-Jung
    • Korean Institute of Interior Design Journal
    • /
    • v.21 no.1
    • /
    • pp.186-194
    • /
    • 2012
  • One hand shopping center provides a public space for people, the other hand it is a place for commercial purpose. Although it gives an entertainment, eating and shopping places to people nowaday, owners and tenants aim to make profit from it. According to this demand designers should plan a shopping center for a comfortable place for eating, shopping and playing and they make shops and retails to increase sales by exposing those to more people at the same time. For successful shopping center architects are requested an approach with commercial strategy that shopping center raises exposure of retails and makes stay costumers longer and visit more frequently. Recently space is regarded as a mean of marketing, so-called "place marketing", because it can influence on brand image and improves the image of product. Therefore, it need to be approached with commercial consideration. Analyzing the armature this study will take a look at spatial strategies in shopping centers which especially the Jerde Partnership, one of influential firms on commercial space, designed. And it will examine how spatial strategies can be applied to commercial strategies in relation to customer information process(exposure-attention-interest-comprehension-memory) which marketers are using in advertisement for marketing and what kind of role spatial strategies can be. This study is to be basic considerations when a shopping center project will be planned.

  • PDF

Epidemiological survey on the relationship between Agent Orange / Dioxin exposure and reproductive anomalies and congenital deformities of inhabitants living in A Luoi valley, Thua thien hue province

  • Hung, Tran-Manh
    • Proceedings of the Korean Environmental Health Society Conference
    • /
    • 2003.06a
    • /
    • pp.26-26
    • /
    • 2003
  • During the Viet Nam war, A Luoi located in Thua Thien Hue Province was heavily sprayed herbicides by the Ranch Hand Operation of U.S.A force (549.274 gallons). After 30 years of knocking the operation off, Dioxin has still contaminated on environment and human body in A Luoi valley. The results of the study show that there is an epidemiological relationship between AO/Dioxin exposure and increasing rate of reproductive anomalies and birth defects (the rate of reproductive anomalies including congenital deformities after the war during 10-year and 25-year is higher than that before the war from 1.5 to 4 times). The study found that the highest rate of reproductive anomalies is spontaneous abortion. The average is premature death and congenital deformities, and the lowest rate is dead foetus and hydratidiform mole. The results of the primary assessment suggested that Dioxin transport from environment to human body through the food chain exposed by Dioxin such as fish, chicken, duck. A mitigation plan for residual dioxin contamination from Agent Orange Hervicides is requeste indispensable to inhabitants in Aluoi District.

  • PDF

Exposure and Risk Assessment for Operator Exposure to Insecticide Acetamiprid during Water Melon Cultivation in Greenhouse using Whole Body Dosimetry (수박 시설재배에서 살충제 Acetamiprid 사용 시 전신노출법에 의한 농작업자의 노출 및 위해성평가)

  • Kim, Eunhye;Lee, Jiho;Sung, Jeonghee;Lee, Jonghwa;Shin, Yongho;Kim, Jeong-Han
    • The Korean Journal of Pesticide Science
    • /
    • v.18 no.4
    • /
    • pp.247-257
    • /
    • 2014
  • Assessment for operator's dermal and inhalation exposure to acetamiprid during cultivation of water melon in greenhouse was carried out. For dermal exposure measurement, whole body dosimetry (WBD) was performed as the first trial in Korea. WBD consists of cotton/polyester outer clothes and cotton inner clothes. Hand exposure was measured by washing of nitrile gloves and hands while head exposure was monitored by face/neck wipe technique. Inhalation exposure was monitored with personal air sampling pumps and IOM sampler (glass fiber filter). Analytical limit of quantitation was 2.5 ng/mL. Good reproducibility (C.V < 8.7%), linearity ($R^2$ > 0.99) and recovery (70~119%) were obtained. Field recovery of acetamiprid was 77~95%. During mixing/loading, hand exposure of acetamiprid was about 10 times ($229.7{\mu}g$) more than that of application case ($20.9{\mu}g$). During application, total dermal exposure was $1207.4{\mu}g$. Exposure of lower legs was $1132.1{\mu}g$, which is 93.8% of the total dermal exposure. Inhalation exposure during mixing/loading and application was not detected. Margin of safety (MOS) was calculated for risk assessment using male Korean average body weight (70 kg) and acceptable operator exposure level ($124{\mu}g/kg/day$) to give 140, suggesting that health risk of operator during treatment of acetamiprid for water melon in greenhouse could be safe.

Individual Exposure Characteristics according to the Humidifier Disinfectant Exposure Assessment Cycle - Focusing on Cycles I-to-V Applicants - (가습기살균제 피해구제 신청자들의 신청 차수별 노출 특성 변화 - 1차에서 5차 신청자를 중심으로 -)

  • Seula Lee;Eun-Kyung Jo;Habyeong Kang;Wonho Yang;Yoon-Hyeong Choi
    • Journal of Environmental Health Sciences
    • /
    • v.49 no.3
    • /
    • pp.159-168
    • /
    • 2023
  • Background: An ongoing environmental exposure assessment of humidifier disinfectants (HDs) has been conducted since November 2011 among individuals who experienced HD exposure-related adverse health effects. It is being performed in order to determine and quantify exposure to humidifier disinfectants in victims and their families. To date, the assessment has encompassed Cycles I-to-V. There is no report summarizing the characteristics of the subjects from the overall cycles. Objectives: We intended to examine the individual characteristics related to demographics, HD usage, and HD exposure using integrated data from Cycles I-to-V of the environmental exposure assessment of HDs and the changes with the cycles. Methods: We included 7,543 individuals who participated in Cycles I-to-V of the environmental exposure assessment of HDs. We summarized the participants' characteristics regarding their demographics (e.g., sex, education level, and age), HD usage history (e.g., product name, ingredient, and frequency of HD use), and HD exposure (e.g., daily time of HD use, cumulative time of HD use, and exposure intensity). In addition, their characteristics were compared across the cycles of the exposure assessment. Results: Among the 7,543 participants from Cycles I-to-V, there were more male participants than females (51.05% overall), except for Cycles I and III. Across all cycles, a higher proportion of survivors was observed than deceased individuals. While PHMG was the most prevalent ingredient in HDs throughout all the cycles, its proportion gradually decreased over the course of the examination cycles. Participants in Cycle I reported longer daily times of HD use compared to those in the subsequent cycles. On the other hand, cumulative time of HD use was shorter in the earlier cycles than in the later cycles. Conclusions: Using the integrated data from the full cycles of the environmental exposure assessment, this study identified changes in demographic characteristics as well as the HD exposure characteristics between the participants across different cycles.

Effect of the amount of battery charge on tube voltage in different hand-held dental x-ray systems

  • Kim, Eun-Kyung
    • Imaging Science in Dentistry
    • /
    • v.42 no.1
    • /
    • pp.1-4
    • /
    • 2012
  • Purpose : Hand-held dental x-ray system is a self contained x-ray machine designed to perform intraoral radiography with one or two hands. The issue about its usage as general dental radiography is still in dispute. The aim of the present study was to assess the relationship between the amount of battery charge and the tube voltage in different handheld dental x-ray systems. Materials and Methods : Seven hand-held dental x-ray units were used for the study. Tube voltage was measured with Unfors ThinX RAD (Unfors Instruments AB, Billdal, Sweden) for 3 consecutive exposures at the different amount of battery charge of each unit. The average and the deviation percentage of measured kV from indicated kV of each unit were calculated. Results : Tube voltage of only 1 unit was 70 kV (indicated by manufacturer) and those of the others were 60 kV. Tube voltage deviation percentage from the indicated kV at the fully charged battery was from 2.5% to -5.5% and from -0.8% to -10.0% at the lowest charged battery. Conclusion : Tube voltages of all units decreased as the residual amount of the battery charge decreased. It is suggested that the performance test for hand-held x-ray system should be performed for the minimum residual charged battery as well as the full charged one. Persistent battery charging is suggested to maintain the proper tube voltage of the hand-held portable x-ray system.

Assessment of Anti-vibration Gloves for Reduction of Hand-transmitted Vibration Exposure (수전달 진동 피폭 저감을 위한 방진 장갑의 성능 평가)

  • Choi, Seok Hyun;Hong, Seok In;Jang, Han Kee
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.18 no.1
    • /
    • pp.1-10
    • /
    • 2008
  • In order to evaluate performance of anti-vibration gloves, it is necessary to measure the transmitted vibration to the hand and the applied forces at the same time while gripping the vibrating handle. In the study a system was developed to measure both the vibration and the forces. The system consists of a measurement handle with eight strain gauges and two accelerometers and a PC-based system with a software for signal processing, evaluation of the hand-transmitted vibration and for control of applied forces in the pre-determined range. The handle was installed on the vibration shaker which is strong enough so as not to be affected by dynamic coupling with the hand-arm. Whole procedure of ISO 10819:1996 to determine the vibration transmissibility of anti-vibration gloves was programmed into the system. As an example of the application, three subjects joined the test to get vibration transmissibilities of 9 anti-vibration gloves where each glove was tested twice a subject. Average and standard deviation of the corrected vibration transmissibility were also calculated. All tested gloves fulfilled criterion for M-spectrum($\overline{TR_M}$<1.0), but one glove fulfilled criterion for H-spectrum($\overline{TR_H}$<6.0),