• 제목/요약/키워드: Hand Strength

검색결과 1,505건 처리시간 0.034초

A study on DC breakdown strength due to variation of specimen shape of epoxy/SiO$_{2}$ compound material treated with silane coupling agent

  • 김명호;김재환;김경환;박찬옥;손인환;박재준
    • E2M - 전기 전자와 첨단 소재
    • /
    • 제5권4호
    • /
    • pp.393-399
    • /
    • 1992
  • In order to increase the coupling strength between bisphenol-A type epoxy resin and filler SiO$_{2}$ it was treated to filler with silane coupling agent[KBM-603]. To observe how silane coupling agent effects on dielectric breakdown strength of Epoxy/SiO$_{2}$ compound material, specimens of eight type were made like following. (A-1, A-2), (B-1, B-2), (C-1, C-2), (D-1, D-2) (see 2-2. Specimen) Specimen treated with silane coupling agent had always bigger dielectric breakdown strength than non-treated specimen. Under the influence of silane coupling agent, increment ratio of dielectric breakdown strength at specimen manufactured by hand drill was very bigger than that of specimen inserted spherical electrode. Therefore, as the specimen shape was varied, it was studied on effect that silane coupling agent affects on dielectric breakdown strength of Epoxy/SiO$_{2}$ compound material.

  • PDF

A study of electromyographic signals during isometric hand pushing and pulling in a free posture

  • Chung, Min-Keun;Lee, Kwan-Suk
    • 대한인간공학회지
    • /
    • 제8권2호
    • /
    • pp.3-18
    • /
    • 1989
  • Two sets of isometric pushing and pulling experiments were performed by two male and two female susbjects. One set of experiments involoved isometric hand pushing and pulling in a standing erect posture, in which the thigh and pelvic regions of the subjects were braced to achieve the greatest strength. Another set of experiments involved isometric hand pushing and pulling in a free posture, in which the subjects elected their preferred postures to attain the largest strength at each of thred handle heights (low-66cm ; mid-109cm ; and high-152cm). It was shown from isometric pushing and pulling experiments in a standing erect poture that the rectus abdominis and the erector spinae muscles were acting as an antagonistic pair with respect to the L5/S1 intervertebral joint, and that the integrated EMG and the muscle force were linearly related. However, the relationships between the integrated EMG and the muscle force during isometric pushing and pulling in a free posture were not well-correlated. It is proposed that the integrated EMG results should be carefully interpreted for tasks of pushing and pulling at various handle heights.

  • PDF

백-밸브-마스크 환기 시 마스크 밀착방법에 따른 환기효과 비교 (Comparison of ventilation effects by mask-sealing methods during bag-valve-mask ventilation)

  • 이남종;백미례
    • 한국응급구조학회지
    • /
    • 제22권1호
    • /
    • pp.73-82
    • /
    • 2018
  • Purpose: The purpose of this study was to compare the tidal volumes and airway pressures of 3 mask-sealing methods (one hand C-E, two hands C-E, and one hand O-E) for ventilation treatment. Methods: The study subjects were 45 paramedic students. Tidal volume was measured for the three sealing methods by setting a ventilator, connecting it to the masks for 2 minutes, and using Respi-trainer software. Results: Regarding general characteristics, the group of men, in upper grades, and with practical training experience and experience and experience in the implementation of bag-valve-mask ventilation provided higher tidal volumes. Regarding physical characteristics, larger hands and greater grip strength correlated with higher tidal volume. Two hands C-E generated the highest tidal volume of $483.78{\pm}34.14mL$, one hand O-E generated $449.59{\pm}51.09mL$ and one hand C-E generated $394.31{\pm}68.95mL$. Conclusion: Means of tidal volumes were statistically significantly different based on mask sealing methods (p<.001). Two hand C-E was performed by the two-persons task and was suggested as the most effective method. For the one-person task, one hand O-E was the more effective method compared to the previous one hand C-E.

Influence of Angle Ply Orientation on the Flexural Strength of Basalt and Carbon Fiber Reinforced Hybrid Composites

  • Mengal, Ali Nawaz;Karuppanan, Saravanan
    • Composites Research
    • /
    • 제28권1호
    • /
    • pp.1-5
    • /
    • 2015
  • In this paper the influence of fiber orientation of basalt and carbon inter-ply fabrics on the flexural properties of hybrid composite laminates was experimentally investigated. Four types of basalt/carbon/epoxy inter-ply hybrid composite laminates with varying angle ply orientation of reinforced basalt fiber and fixed orientation of carbon fiber were fabricated using hand lay-up technique. Three point bending test was performed according to ASTM 7264. The fracture surface analysis was carried out by scanning electron microscope (SEM). The results obtained from the four laminates were compared. Lay-up pattern of $[0B/+30B/-30B/0C]_S$ exhibits the best properties in terms of flexural strength and flexural modulus. Scanning electron microscopy results on the fracture surface showed that the interfacial de-bonding between the fibers and epoxy resin is a dominant fracture mode for all fiber lay-up schemes.

Tire 및 Tube의 품질(品質) 보강(補强)에 관(關)한 연구(硏究)(제2보(第2報)) 천연(天然) 및 합성(合成)고무의 변량혼합(變量混合)에 따른 이화학적(理化學的) 성능(性能) (Studies on the Quality Reinforcement for Pneumatic Tire and Tube. Part 2. Physical Properties of NR-Syn. R blends.)

  • 김준수;이명환;염홍찬;이진범;박창호;홍종명;임동호;이종근
    • Elastomers and Composites
    • /
    • 제3권1호
    • /
    • pp.32-38
    • /
    • 1968
  • The physical properties of NR-SBR and NR-BR blends were studied. 1. In blending, tensile strength decreased with increase in synthetic rubber contents. It was most effective when the ratio of NR/Syn. R is 75/25. 2. Tensile strength decreased with order of NR, SBR and BR and modulus after aging is proportional of synthetic rubber contents. 3. Elongation is less influenced by synthetic rubber ratio that on the other hand, the decrease of elongation is proportional to synthetic rubber contents after aging. 4. Hardness decreased with increase in the synthetic rubber contents and on the other hand, the hardness increased after aging.

  • PDF

비스코스 레이온 직물의 방축가공 (Shrinkproof Finish of Viscose Rayon Fabric)

  • 김성동;이인열;이종렬;김민정
    • 한국염색가공학회지
    • /
    • 제10권6호
    • /
    • pp.20-26
    • /
    • 1998
  • 100% viscose rayon fabric was treated with 1,2,3,4-butanetetracarboxylic acid (BTCA) by pad-dry-cure process in the presence of various catalysts. The dimensional stability, mechanical properties and hand values of fabric treated with BTCA were investigated. The ester-crosslinking reaction was influenced by the concentration of BTCA and type of catalyst. The fabric treated with BTCA was comparable or superior to that treated with conventional crosslinking agents such as dimethyloldihydroxyethyleneurea and 4,5-dihydroxy-1,3-dimethyl-2-imidazolidinone in respect of wrinkle recovery, shrinkproof property, retention of strength, and hand values. But in yellowing of fabric, the fabric treated with BTCA was inferior to that treated with conventional crosslinking agents. The fabric treated with BTCA/sodium formate was inferior to that treated with BTCA/sodium hypophosphite in respect of WRA, but had better strength retention and whiteness.

  • PDF

Comparisons of Test-Retest Reliability of Strength Measurement of Gluteus Medius Strength between Break and Make Test in Subjects with Pelvic Drop

  • Jeon, In-Cheol
    • The Journal of Korean Physical Therapy
    • /
    • 제31권3호
    • /
    • pp.147-150
    • /
    • 2019
  • Purpose: The purpose of this study was to compare the reliability of unilateral hip abductor strength assessment in side-lying with break and make test in subjects with pelvic drop. Hip abduction muscles are very important in the hip joint structures. Therefore, it is essential to evaluate their strength in a reliable way. Methods: Twenty-five subjects participated in this study. Unilateral isometric hip abductor muscle strength was measured in side-lying, with use of a specialized tensiometer using smart KEMA system for make test, of a hand held dynamometer for break test. Coefficients of variation, and intra class correlation coefficients were calculated to determine test-retest reliability of hip abductor strength. Results: In make test, maximal hip abductor strength in the side-lying position was significantly higher compared with break test (p<0.05). Additionally, Test-retest reliability of hip abductor strength measurements in terms of coefficients of variation (3.7% for make test, 16.1% for break test) was better in the side-lying position with make test. All intraclass correlation coefficients with break test were lower than make test (0.90 for make test, 0.73 for break test). Conclusion: The side-lying body position with make test offers more reliable assessment of unilateral hip abductor strength than the same position with break test. Make test in side-lying can be recommended for reliable measurement of hip abductor strength in subjects with pelvic drop.

장애인을 위한 재활간호프로그램이 근력, 유연성, 자기 효능감과 건강관련 삶의 질에 미치는 효과 (Effects of a Rehabilitation Nursing Program on Muscle Strength, Flexibility, Self efficacy and Health Related Quality of Life in Disabilities)

  • 이혜영
    • 대한간호학회지
    • /
    • 제36권3호
    • /
    • pp.484-492
    • /
    • 2006
  • Purpose: The purpose of this study was to investigate the effects of a rehabilitation nursing program(RNP) for persons with disabilities. Method: a quasi-experimental pretest and post test study was used to examine the changes of patient's muscle strength, flexibility, self efficacy and health related quality of life at the completion of an 8-week education and physical exercise with a Thera-Band and Exercise Ball course. The subjects consisted of 40 adults who were disabled. Twenty-two experimental and 18 control subjects completed pre and post-test measures. Outcome variables were flexibility, hand grip, elbow flexor and extensor, knee flexor and extensor, self efficacy and quality of life. Independent t-test and ANCOVA were used to examine group differences by using SPSS 12.0 Result: Mean comparisons of the change scores revealed that the experimental group increased significantly in knee extremity flexor(p=0.035), extensor(p=0.039), flexibility(p=0.008), self efficacy(p=0.000), and quality of life(p=0.000). No significant group differences were found in each patient's hand grip, elbow flexor and extensor. Conclusion: RNP can improve lower extremity flexibility, muscle strength, self efficacy and health related quality of life in people with disabilities. The intervention to tailor exercise and education to the unique needs of the disability was suggested for further study.

렌치 작업에서의 청년층의 상지근력 및 근피로도에 관한 연구 (Upper Limbs Related Muscle Strength and Fatigue During the Wrench Job for Korean Young Aged)

  • 윤훈용;김은식
    • 산업경영시스템학회지
    • /
    • 제35권2호
    • /
    • pp.88-97
    • /
    • 2012
  • The muscle strengths in various postures are still used in the workplace, although mechanization and automation have been continuously accomplished. The aim of this study is to measure the maximum muscle strength and analyze the muscle fatigue during the various wrench jobs which are one of the upper limbs related works. Four hundreds and eighty five college students (243 males and 242 females) participated in this study. Twelve muscle strengths which are using for pulling, pushing, lifting and lowering the wrench with various postures are measured. For every moment, the muscle strengths for both hands were measured. In each measurement, five seconds averaged value and peak value were collected. The averaged value of preferred hand and non-preferred hand was compared. Also, the averaged value of opposite movement was compared through t-test. The fatigue of agonist for each movement was analyzed using EMG analysis. The result of this study can provide some basic information not only in designing the tools in work but also in selection, training and management of workers.

사회기반시설에 적용되는 수작업형 폴리우레아 방수·방식재료의 열화조건에 따른 부착성능평가 및 분석에 관한 연구 (Manually applied to the social infrastructure polyurea waterproofing materials, methods based on the deterioration of conditions attached Performance Evaluation and Analysis)

  • 최은규;김윤호;이혜령;김수연;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2012년도 춘계 학술논문 발표대회
    • /
    • pp.41-42
    • /
    • 2012
  • High temperature / high pressure spray equipment using a conventional method, unlike spray polyurea adjustable pot life and yellowing caused by UV light and chemicals do not occur, or discoloration of Self-Leveling Type of rugged hand-polyurea resin for technology development is underway. This new concept of polyurea resin roller, brush, airless spray, and they installed easily using the unfamiliar labor, and curing time of approximately four hours to gain control of the glass because it is Pot. Construction, but does not like the spray polyurea resin, compared to the existing degradation of the adhesion strength is concerned. In this study, Self-Leveling Type Manual of polyurea resin adhesion strength of target deterioration Let's minimize problems by reviewing existing domestic and infrastructure long-term durability for long life of the facility is to obtain.

  • PDF